Download as pdf
Download as pdf
You are on page 1of 8
2 (-JUL-H812 18:48 From: HOISTSPLANT e458000791 Te:02084416449 Pesert-8 Hoist & Plant Hire Co Ltd 20-22 Factory Lane, Croydon, Surrey, CRO3RL Telephone 0845 880 0790 Fax 0845 880 0791 Te: Adam / JDC Scafolding From: Daniel Evans Faxc 02084416449 Pages: 8 incheader Phonet Date: 177.12 Re: Regent Steet / Mortimer Street ce: Gument OForReview Please Comment Ci Please Reply HiAdam ‘We sti have no intemet here, so have attached the drawings you need Regards Danie! 1T-JUL-2012 16:49 From:HOISTSPLANT eeasse0e7s1 To:aezBa416449 Paoete/8 Wickham GP 1200 Passenger/Goods Hoist Maximum rated load —_1200kg or 15 Persons Power 41Sv Ba Maximum tie interval 9m Average lifting speed 28m/min LT-JUL-2B12 18:49 From: HOISTRPLANT 8458800791 Torgen84416443 Paver 38 seaeR-08 120 oomoaste spy Heat Passenger & Material Hoists Single Motor Drive Carriage FEATURES = ‘Sepevaie drhw cartage ats a wide combination of citer orasenger oF malereie cages ta bo used ages sinpiy bolt sracty onto ha diva cariage win 4 Dons, cnly it sustenes need tobe conngeted ta eariaue eaerieal pane! | Base sviround cage s moduler and ean be changed {o nate cfferanl aia cages, and up ts three ‘enteence getes par age. sae unit ean teted inte pesto ‘8a eompiets unt or dariandéd ine emeter locos wher reyuited Uy alia hati raaetione Tain | S00 TBE] POOR TER [ SORT TROD | GOT TEA fe "800 "600 1099) 209) Ne ° 2 2 6 mine | 28 B Py 2 m o ¢ ° A ” ° ° ° 2 n 5 8 9 a = * 4 4 . n 180 180 2 180 a 08 sain 1208 1208 a Oo oe 2 6 we | mo 08s 20 005, ee | axes fet at taat . wa] ie te 6 seo reo 190 Wieeciast Yn ney 41-42 Bemers $1. ‘Some! Co\potutton Sdn Bhd a iaies — Eeeeial Sse ‘Tet (603) 4256 9703 Te (603) 4257 2670 17-JUL-2812 18:49 From: HOISTEPLANT wesse800791 To: 02084416449 = dob JOC MORTIMER ST i ® Date 21812 - Oe Cage typa (1-11 see let belaw) 4 om Zone (AB.C.D or E) Ca TLH Factor (1-4 see tet below) 2 Dimension ‘8’ mm 2400 Dymension ‘0° mm #200 Dimension .! mm 7000 Top ite space m 90 Mast above top te m 45 Notes. Zones are as per BS EN12158 Annex A) At min 20 deg. Max 45 deg, Rent aye erat fa Pann Pan Hoist in Service. wind direction 28 Rx Case 6 a 82 83 a7 a2 Host in Service, wind direction cpposite to Rx Case2 5 ry 6 32 a7 Hoist in Service. wind direction as Ry Case 3 4 on ot “4 or Hoist in Service, wind direction opposite to Ry Case 4 n 3a on “8 os a8 Hoist n Service, wind diagonal for max F4 Cese 5 so 1 23 22 4s az Horst n Service, wind diagonal for max P2 Case 6 ee s 22 83 a3 80 Hoist out of Service, wind direction as Rie Case 7 3 ve a? 2? 18 18 Hoist out of Service, wind direction opposite to Rec Case8 es 20 a7 ar 48 16 Hosst cut of Service, wind direction as Ry Cased oy > 46 46 2 2a Hoist out of Service, wind direction opposite to Ry Case 10 ee $ “8 45 an 28 Hoist cut of Service, wind diagonal for max P4 Case 11 47 oe 62a 18 7 10 Hoist out of Servies, wind diagonal for max P2 Case 12 . s 18 82 08 37 Hoist Type Table Value TLHm Input value LP-JUL-2012 10:49 From: HOISTEPLANT es458800791 Toraene416449 RACK AND PINION mod. MB 500/120-S ELEVATOR mod. MB 500/120-SP se =| Wb pote. dea agp, my fe wey ee ee x need eight iis on wide For ochre tone ee lating aera (cacy fg sto wh mm, 1300 ww cm Bx B Tower ‘Three phose vetage 500-50 Ha leg pond mfnin, 5 chai centr emergency bce Timareca ABS Suprise tte. AT-JUL-2012 10:50 From: HOTSTAPLANT eeaseece731 To:zens44i6449 MABER BASE LOADINGS we500/120 SP. MB500/120 S Hast loadmes aS es was a a a ea al Ta it oman pares [300 rene 45, — 379° [=30—|— js ts! 30> pms O18 48 ey} ee} ey a [got “se | — 200 8 rT a —ier 39] er ota fossa foe = 1282 : coi to 8 200 185. 1 i 80 128 195 se — 300 Tae 219—|— 355 | aa “a sas | 15 240 |e —| ap) se 355 | —Hiea a0 2a ie} — 0 71 | 3004520" 35 | | son 1 33.0 [3798 300 | 898 37a 1a 60 Wie, 08 a 178 a0 | tee} — ao Tat a | gags} gp — [ago 3s] — ao Ta 5 tS rt [450° 1810 [390 Tf 7310, i Am] tae ae 165—| 1801 a | a8 — aa —]— “ts a a 7 Ei 0-3 {= a a 0 is 7 25 _j480s | soo. ce ee Ce 0 3s} m0 eat a i 0 st 201 a on 2 28 aaa ——2et7 i oe Eo ‘at = a 200 wr 0 |r 300 | 28a" 500. 2728 300. t “er 300 | sar —t ——} o_o = ee Ls} 7 5 {a apse | 90 arnt [Tf [0 TT 68 —-——} ate ae 30) —sa02 | 500 ‘3241 a —_—o soo | — sa 0 — | — sr son —| "sess —| “so aes ts —| “Se 3053 300 T3353 100.5 35S. 50g | 3a v if w o J 3 z A rc 2, Ub, AT-JUL-2812 10:50 From:HOISTEPLANT gease90a791 To:82084416449 Pase:7/8 15. STANDARD WALL MOUNTING The wall mounting, that must be secured every 6 m., is used to vertically support the whole frame and is this a very important element of the machine. Therefore, very firmly tighten all screws and clamps and frequently check they are tightened properly. wena y Warning!!! Not to interfere with the bolts, fasten the release lever (a) of the tuming plate parallel to the deck wall. 29 A(-JUL-eMe LUIS. Prom MLAS 1PLHNT Maber Tie Forces: eee lorBeMUHHIbAaS 1daN = 10N therofore to convert daN to KN we divide by 100 N mt Tt] + 350daN | + 300daN | + 300daN MB500/120 - U Tie + 3.5 KN = TKN = 3 RN MBSO0/1 20 + 350daN | + 300daN | + 300 daN Straight Ties = 3.5 KN = 3 KN = 3 KN | MBSOOTS0ES =1200daN | _=700daN | 2700daN | + 12KN = 7KN _7KN. MB1500/150 + 1700daN | + 650daN | = Gd0daN Type ‘A’ Tie = 17KN = 65KN = 6.5KN MBTS00/150 d “= 650daN Type ‘B' Tie + 17KN = 6.5KN + 6.5KN

You might also like