Professional Documents
Culture Documents
lu3IC: DC 2-Wire Type
lu3IC: DC 2-Wire Type
Autonics INDUCTIVE PROXIMITY SENSOR 00 Specifications 00 Mutual-interference & Influence by Surrounding Metals
PRT12-2□O PRT12-4□O PRT18-5□O PRT18-8□O PRT30-10□O PRT30-15□O ◎Mutual-interference
DC 2-WIRE TYPE PRT08-1.5DO
PRT08-1.5DC
PRWT08-1.5DO
PRT08-2DO
PRT08-2DC
PRWT08-2DO
PRT12-2□C
PRWT12-2□O
PRWT12-2□C
PRT12-4□C
PRWT12-4□O
PRWT12-4□C
PRT18-5□C
PRWT18-5□O
PRWT18-5□C
PRT18-8□C
PRWT18-8□O
PRWT18-8□C
PRT30-10□C
PRWT30-10□O
PRWT30-10□C
PRT30-15□C
PRWT30-15□O
PRWT30-15□C PSNT17-5DO
When plural proximity sensors are mounted in a close row, malfunction of sensor may be caused due to mutual interference.
Therefore, be sure to provide a minimum distance between the two sensors, as below table.
~ ~ ~
Standard 18×18×1mm 25×25×1mm 30×30×1mm 45×45×1mm 18×18×1mm
sensing target
Setting distance
8×8×1mm(Iron)
0 to 1.05mm I0 to 1.4mm
I
12×12×1mm(Iron)
I(Iron) (Iron) I (Iron) (Iron)I (Iron) I I Ød
m
Warning l m
Envron IAmbient temp. -25 to 70℃ Storage: -30 to 80℃ B 36 A
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic -ment IAmbient humi. 35 to 95%RH, Storage: 35 to 95%RH ~-, ~
C 5 ℓ
loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety Protect on circuit Surge protection d 15
equipment, crime/disaster prevention devices, etc.) ISurge protection circuit, overload & short circuit protection m
Protection IP67( EC Standard) ℓ 24 C d
Failure to follow this instruction may result in fire, personal injury, or economic loss.
2. Do not disassemble or modify the unit. Ø3 5mm, 3-wire, 2m Ø4mm, m 18
(AWG24, Core diameter: I
Ø4mm, 2-wire, 2m
I
Ø5mm, 2-wire, 2m
I
2-wire, 2m
Cable※3
Failure to follow this instruction may result in fire.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire.
PRT
0.08mm, Number of cores: 40,
Insulator diameter: Ø1mm) I
(AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1 25mm) 00 Connections
PRWT Ø4, 2-wire, 300mm, M12 connector Connector connection for standard Connector connection for
4. Check 'Connections' before wiring. IØ5, 2-wire, 300mm, M12 connector I- DC 2-wire standard
type model IEC standards model
Failure to follow this instruction may result in fire. Case/Nut : Nikel plated Brass, Washer : Nikel plated Iron, Sensing surface : PBT,
Materials Brown
~ ~
Standard cable(Black) : Polyvinyl chloride(PVC), Oil resistant cable(Gray) : Oil resistant Polyvinyl chloride(PVC)
Caution I Brown 2 1 2 1 Load +V
Approval CE Brown
~
1. Use the unit within the rated specifications. Load +V +V
PRT: Approx. 84g(Approx. 72g) PRT:Approx. 122g(Approx. 110g) PRT:Approx. 207g(Approx. 170g) PSNT: 3 4 3 4
Failure to follow this instruction may result in fire or product damage. PRT: Approx. 64g(Approx. 52g) Blue
Weight※ PRWT: Approx. 54g(Approx. 42g) PRWT:Approx. 70g(Approx. 58g) PRWT:Approx. 134g(Approx. 122g) Approx. 92g 0V
2. Use dry cloth to clean the unit, and do not use water or organic solvent. Blue
Failure to follow this instruction may result in fire.
PRWT: Approx. 44g(Approx. 32g)
I I I
PRCMT:Approx. 38g(Approx. 26g) PRCMT:Approx. 60g(Approx. 48g) PRCMT:Approx. 154g(Approx.142g) (Approx. 71g) I Blue
0V Load 0V (a)N.O.(Normally Open) Type
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, ※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard Brown
~ '®
Brown 2 1 Load +V
==
impact, or salinity may be present. sensing target, 1/2 of the sensing distance for the distance. +V 2 1
~
Failure to follow this instruction may result in fire or explosion. ※2: Before using non-polarity type, check the condition of connected device because residual voltage is 5V. Brown 3 4
4. Do not supply power without load. 3 4 Load +V Blue
※3: Do not pull the Ø3.5mm cable with a tensile strength of 25N, the Ø4mm cable with a tensile strength of 30N or over and the Ø5mm 0V
Failure to follow this instruction may result in fire or product damage. cable with a tensile strength of 50N or over. Blue (b)N.C.(Normally Closed) Type
Load 0V Blue
0V ※②,③ of N.O. type and ③,④ of N.C. type
Ordering Information It may result in fire due to the broken wire. When extending wire, use AWG22 cable or over within 200m.
※4: The weight with packaging and the weight in parentheses is only unit weight. ※①,② are not used terminals. are not used terminals.
※Environment resistance is rated at no freezing or condenstion. ※Load can be wired to any direction. ※No need to consider polarity for non-polarity type of power supply.
P R CMT 12 2 D O U IV No mark Standard cable
Cable type I Standard cable( EC standards model)
V Oil resistant cable 00 Dimensions (Unit: mm)
Installation and Tightening Torque [Table 1]
IV Oil resistant cable( EC standards model)
When tightening the nut, use the provided washer as [Figure 1].
Cable type Cable connector type Connector type Cable type Strength Front Rear
Sensing side No mark Standard type Type When installing the product, the tightening torque of the nut varies
PRT(M8, M12, M18, M30) PRWT(M8, M12, M18, M30) PRCMT(M12, M18, M30) PSNT17 Model Size Torque Torque
according to the distance from the fore-end.
U Upper sensing type B B J PRT08 Flush 7mm
B 30.8 2-Ø3.2 The front part of the product is from the fore-end to the dimension on 3 92N m 8.82N m
~ ~ lL ~
C J C the below table, and the rear part is from the tip of the nut to the end Series Non-flush 5mm
Control output O Normally Open(N.O.) C
Power supply
C
X
Normally Closed(N.O.)
12-24VDC(Non-polarity type)
Flush
A
F
r;:;1 ~ I ~
D
A
F M12×1
A
M12×1
18
LED
11
of the product. [Figure 2]
In case the nut is placed in the front part of the product, apply
tightening torque for front part.
[Table 1] the allowable tightening torque table is for inserting the
PRT12 Flush
Series Non-flush
PRT18 Flush
13mm
7mm
-
6 37N m
14.7N m
11.76N m
D 12-24VDC
lLD D
washer as [Figure 3].
Series Non-flush -
B B J B
Sensing distance PRT30 Flush 26mm
I ~ rn~-
49N m 78.4N m
~ ~~ L "------ I. .I. .I
Number Standard sensing distance(Unit: mm) E C J C E C Ø4 Series Non-flush 12mm
Dimension Number
Number
Diameter of head(Unit: mm)
One side length(Unit: mm)
Non-
flush bl A
F E A
F
M12×1 A
M12×1
18
35.6 2,000
[Figure 1] [Figure 2]
Fore-end
Nut tip [Figure 3]
!TI®
D
T DC 2-wire, cable type lLD D
[[@ 1JJt
Connection
WT DC 2-wire, cable connector type Nut
&
G
G
H
Washer Washer Mounting
Front Rear bracket
Shape R Cylindrical type
SN Square new design type Type A B C D E F G H J
tem
P Inductive proximity sensor
PRT M8×1 30 30 4 - 35 13 15 2,000 Cautions during Use
M8
PRWT M8×1 30 30 4 - 4 13 15 300 1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
PRT M12×1 46 31.5 4 - 4 17 21 2,000 2. 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
00 Control Output Diagram & Load Operation M12 PRWT M12×1 46 31.5 4 - 4 17 21 300
3. Use the product, after 0.8 sec of supplying power.
4. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
Normally Open Normally Closed PRCMT M12×1 55.8 31.5 4 - - 17 21 - Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.).
Load +V
lu3IC
Brown Sensing Presence Presence Flush PRT M18×1 47.5 29.5 4 - 5 24 29 2,000 In case installing the product near the equipment which generates strong surge (motor, welding machine, etc.), use diode or varistor
_O__ _O__
Main circuit
target Nothing Nothing M18 PRWT M18×1 47.5 29.5 4 - 5 24 29 300 to remove surge.
PRCMT M18×1 54.3 29.5 4 - - 24 29 - 5. Do not connect capacity load to the output terminal directly.
Operation Operation
Load _O__ 6. This unit may be used in the following environments.
Return Return PRT M30×1.5 58 38 5 - 5 35 42 2,000
① Indoors (in the environment condition rated in 'Specifications') ② Altitude max. 2,000m
Blue Operation indicator ON ON M30 PRWT M30×1.5 58 38 5 - 5 35 42 300
0V ③ Pollution degree 2 ④ Installation category II
(Red RED) OFF _O__ OFF PRCMT M30×1.5 63.8 38 5 - - 35 42 -
PRT M8×1 30 26 4 4 35 13 15 2,000
M8
00 Setting Distance PRWT
PRT
M8×1
M12×1
30
46
26
24.5
4
4
4
7
4
4
13
17
15
21
300
2,000
00 Major Products
Target Target ● Detecting distance can be changed by the shape, size or material of the target. ■ Photoelectric Sensors ■ Temperature Controllers ■ Graphic/Logic Panels
M12 PRWT M12×1 46 24.5 4 7 4 17 21 300 ■ Fiber Optic Sensors ■ Temperature/Humidity Transducers ■ Field Network Devices
Therefore please check the detect ng distance like (a), then pass the target within range
Moving
direction
F=€1 Moving
direction Sa Sn
●
of setting distance(Sa).
Setting distance(Sa)
= Sensing distance(Sn)× 70%
Non-flush
M18
PRCMT
PRT
PRWT
M12×1
M18×1
M18×1
55.8
47
47
24.5
19
19
4
4
4
7
10
10
-
5
5
17
24
24
21
29
29
-
2,000
300
■ Door Sensors
■ Area Sensors
■ Proximity Sensors
■ SSRs/Power Controllers
■ Door Side Sensors ■ Counters
■ Timers
■ Panel Meters
■ Laser Marking System(Fiber, CO₂, Nd:YAG)
■ Laser Welding/Cutting System
' '
E g.)PRCMT12-2DC PRCMT M18×1 53.8 19 4 10 - 24 29 - ■ Pressure Sensors ■ Tachometers/Pulse(Rate) Meters
Sn: Sensing distance
{ Sa: Setting distance Setting distance(Sa) = 2mm × 0.7 = 1.4mm PRT M30×1.5 58 28 5 10 5 35 42 2,000 ■ Rotary Encoders ■ Display Units
■ Connectors/Sockets ■ Sensor Controllers
(70% of Sn) M30 PRWT M30×1 5 58 28 5 10 5 35 42 300 ■ Switching Mode Power Supplies
(a) (b) Control Switches/Lamps/Buzzers
PRCMT M30×1 5 63.8 28 5 10 - 35 42 - ■ DRW171496AA
※The above specifications are subject to change and some models may be discontinued without notice. ■ I/O Terminal Blocks & Cables
※Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage). ■ Stepper Motors/Drivers/Motion Controllers