GENERAL NOTES:

N
1. THIS DESIGN IS FOR MOBILE CRANE AND CRAWLER CRANE PADS AT
THE ST MARY'S STATION SITE ON THE WESTERN SYDNEY AIRPORT
SPOIL STOCKPILE STATION BOXES AND TUNNELING PROJECT.

DESIGN NOTES:
1. THE MINIMUM ALLOWABLE BEARING CAPACITY IS ASSUMED TO BE
150kPa. THE BEARING CAPACITY IS TO BE VERIFIED BY A
LOADING BAY
GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF THE BLINDING
WHEEL WASH
LAYER.
2. B2 EXPOSURE CLASSIFICATION IS ASSUMED, IN NON AGGRESSIVE
(3x3) SOILS. BG&E TO BE NOTIFIED IF GROUND CONDITIONS ARE
SECURITY
DIFFERENT THAN ANTICIPATED.
(6x3) 3. PILE TOE RL HAS BEEN PROVIDED AS PER ADVICE RECEIVED BY
FIRST AID CRANE PAD 1 & ABLUTIONS (3x12)
OFFICES, CRIB, WTP
ARCADIS VIA EMAIL ON 25/5/22.
STORES WORKSHOPS
28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

CRANE PAD 2
30 29

CHANGE ROOM (33x12)


OFFICES, BATH HOUSE, &
DESIGN LOAD NOTES:
THE FOLLOWING LOADS HAVE BEEN CONSIDERED IN THIS DESIGN:
1. 125t MAX OUTRIGGER LOAD CAPACITY DIRECTLY OVER PILE (REFER
TO LOAD CASE 1 ON DRAWING SMWSASBT-CPG-STM-SN100-TW-
R F F R DRG-032903).
2. 60t OUTRIGGER LOAD EQUALLY SPACED BETWEEN PILES (REFER TO
LOAD CASE 2 ON DRAWING SMWSASBT-CPG-STM-SN100-TW-
DRG-032903).
3. 100t CRAWLER CRANE WITH MAXIMUM TRACK PRESSURE OF 200kPa
(3x3)
SECURITY
E E AT ANY LOCATION ALONG BEAM B1 AND B2 (REFER TO LOAD CASE 3
ON DRAWING SMWSASBT-CPG-STM-SN100-TW-DRG-032903).
4. 30t POINT LOAD AT ANY LOCATION ALONG BEAM B1.
5. 20 kPa UNIFORMLY DISTRIBUTED LOAD.
6. A 50mm TOLERANCE HAS BEEN ALLOWED IN THE DESIGN FOR THE
SETOUT OF THE OUTRIGGERS AND CRAWLER CRANE LOADS.

SITE PLAN
SCALE 1 : 1000

CRAWLER TRACK TO BE ON
C PADS DURING LIFT. TRACKS TO
BE PARALLEL TO WALL CRAWLER TRACK TO BE ON
8400

File Path: Autodesk Docs://CPB_SM-WSA-SBT Delivery/SMWSASBT-CPG-STM-SN100-TW-M3D-030701.rvt


PADS DURING LIFT. TRACKS TO
EQ EQ C BE PARALLEL TO WALL
8400
1800

C
EQ EQ

B2 N 6261879.151 m
N 6261877.629 m

1800
E 294336.299 m C
4150

E 294344.865 m 10700
EQ EQ N 6261933.468 m N 6261934.990 m
E 294031.196 m B2 E 294022.630 m
100mm AT FULL SIZE Plot Date & Time 3/04/2023 11:45:03 AM

.
DIA 10700

4150
750
1800

C
EQ EQ
P1

P1

2000

2750 B1 .
2800

DIA

P1

P1
FROM PILE CL 1000 8700 1000

1800
750 C
R
F R
F

2000
1000 8700 B1 1000 3875
2700
R
F FROM EDGE R
F
TYP. CENTRE OF CRANE BEAM
B1 TO ALIGN WITH THE
CENTRE OF SHORING
WALL PILE 2700 TYP.
1 2 CENTRE OF CRANE BEAM
032902
032902 B1 TO ALIGN WITH THE
CENTRE OF SHORING WALL
PILE

CRANE PAD 1 SETOUT PLAN CRANE PAD 2 SETOUT PLAN


SCALE 1 : 100 SCALE 1 : 100

OFFICIAL APPROVED FOR CONSTRUCTION


SCALES: 1:1000, 1:100 CLIENT The information shown on this drawing is for the purposes of the Sydney Metro Project only. No warranty is given or implied as to its suitability for any
other purpose. The Service Providers accept no liability arising from the use of this drawing and the information shown thereon for any purpose other
than the Sydney Metro Project.
SYDNEY METRO - WESTERN SYDNEY AIRPORT – STATION BOXES AND TUNNELLING WORKS
SN100 - ST MARYS METRO STATION
DRAWN ANOJ KHADKA 03.04.2023 TEMPORARY WORKS
1 0 1 2 3 4
DESIGNED KERROD POTTER 03.04.2023
1:100 @ A1 m SETOUT PLAN
00 APPROVED FOR CONSTRUCTION KP LA CL 03.04.23 DRG CHECK ROCCO CALARCO 03.04.2023
10 0 10 20 30 40 FILE No: SMWSASBT-CPG-STM-SN100-TU-M3D-011505.rvt SHEET: 1 OF 4 C
REV. AMENDED DESCRIPTION Design Verified Approved Date
1:1000 @ A1 m BGE DESIGN CHECK LEONARD AMBROGI 03.04.2023 STATUS: ISSUED FOR CONSTRUCTION EDMS No:
by by by
REV VER
A1 Original Co-ordinate System: GDA2020/MGAZone56 Height Datum: A.H.D This sheet may be prepared using colour and may be incomplete if copied NOTE: Do not scale from this drawing. SYDNEY METRO
STRUCTURAL APPROVED CHRIS LAWTON 03.04.2023 DRG No.SMWSASBT-CPG-STM-SN100-TW-DRG-032901 00
PROVIDE 8m EXCLUSION ZONE
BOGMATS MAY BE DURING CRAWLER CRANE USE
OMITTED. PILE
CONTRACTOR TO MARK
PILE LOCATION ON SITE. 1800 WIDE x 500 DEEP
CRANE TO BE CENTRED CRANE BEAM B1
ON PILES
CRANE OUTRIGGER
CRANE OUTRIGGER CRANE OUTRIGGER
CRANE OUTRIGGER

B1 B2 400t & 100t MOBILE CRANE OUTRIGGERS TO BE


B1 B2
2800 4150 AxB PROVIDED ON BOGMAT WITH MAX 200kPa
TO SUIT CRAWLER DIMENSION B IS LENGTH INTO PAGE BEARING PRESSURE UNDER BOGMAT. BOGMAT
200mm THICK TYPE 3 RIGID TO BE INSTALLED ON 200 THICK RIGID PAVEMENT
C 400t & 100t MOBILE CRANE OUTRIGGERS TO BE PAVEMENT. PROVIDE MOVEMENT OR CRANE BEAM. IF CRANE PAD IS INSTALLED ON
200mm THICK TYPE 3 RIGID JOINT AT CRAME BEAMS
PROVIDED ON BOGMAT WITH MAX 200kPa SITE FILL BEARING PRESSURE TO BE LIMITED TO
PAVEMENT. PROVIDE MOVEMENT 2780 4170
BEARING PRESSURE UNDER BOGMAT. BOGMAT 150kPa UNDER BOGMAT.
1800 WIDE x 500 DEEP JOINT AT CRAME BEAMS TO SUIT CRAWLER
TO BE INSTALLED ON 200 THICK RIGID PAVEMENT BEARING PRESSURE CAPACITY OF FILL MUST BE
CRANE BEAM B1
OR CRANE BEAM. IF CRANE PAD IS INSTALLED ON BOGMATS MAY BE OMITTED. PILE CONFIRMED BY A SUITABLY QUALIFIED
SITE FILL BEARING PRESSURE TO BE LIMITED TO CONTRACTOR TO MARK PILE GEOTECHNICAL ENGINEER.
150kPa UNDER BOGMAT. LOCATION ON SITE. CRANE TO BE
BEARING PRESSURE CAPACITY OF FILL MUST BE CENTRED ON PILES
750 DIA PILE, 10N28 CONFIRMED BY A SUITABLY QUALIFIED
REINFORCEMENT WITH N12-300 GEOTECHNICAL ENGINEER.
SOIL PROFILE LEGEND
SPIRALS, REFER TYPICAL TOP OF S1 - FILL
DETAILS TOP OF S2 - ALLUVIUM
TOP OF S3 - RESIDUAL SOIL
C
TOP OF R1 - BRINGELLY SHALE CLASS IV/V
TOP OF R2 - BRINGELLY SHALE CLASS III

RETENTION WALL PILE BY OTHERS


RETENTION WALL PILE BY OTHERS

TOP OF R3 - BRINGELLY SHALE CLASS II OR BETTER


CLASS V LOCALISED
R1 LOCALISED
R3 LOCALISED
P1

P1
750 DIA PILE, 10N28
REINFORCEMENT WITH N12-300
SPIRALS, REFER TYPICAL
DETAILS

File Path: Autodesk Docs://CPB_SM-WSA-SBT Delivery/SMWSASBT-CPG-STM-SN100-TW-M3D-030701.rvt


100mm AT FULL SIZE Plot Date & Time 3/04/2023 11:45:18 AM

MIN 2500 BELOW EXCAVATION LEVEL


MIN 2500 BELOW EXCAVATION LEVEL

NOMINATED BY ARCADIS
BASE OF EXCAVATION
NOMINATED BY ARCADIS

BASE OF EXCAVATION

INDICATIVE PILE TOE


RL 15.722

INDICATIVE PILE TOE


RL 16.048 CRANE PAD 1 TYPICAL SECTION CRANE PAD 2 TYPICAL SECTION
SCALE 1 : 50 OFFICIAL SCALE 1 : 50 APPROVED FOR CONSTRUCTION
SCALES: 1:50 CLIENT The information shown on this drawing is for the purposes of the Sydney Metro Project only. No warranty is given or implied as to its suitability for any
other purpose. The Service Providers accept no liability arising from the use of this drawing and the information shown thereon for any purpose other
than the Sydney Metro Project.
SYDNEY METRO - WESTERN SYDNEY AIRPORT – STATION BOXES AND TUNNELLING WORKS
SN100 - ST MARYS METRO STATION
DRAWN ANOJ KHADKA 03.04.2023 TEMPORARY WORKS
DESIGNED KERROD POTTER 03.04.2023
CRANE PAD 1 AND 2 TYPICAL SECTIONS
00 APPROVED FOR CONSTRUCTION KP LA CL 03.04.23 DRG CHECK ROCCO CALARCO 03.04.2023
500 0 500 1000 1500 2000 FILE No: SMWSASBT-CPG-STM-SN100-TU-M3D-011505.rvt SHEET: 2 OF 4 C
REV. AMENDED DESCRIPTION Design Verified Approved Date
1:50 @ A1 mm BGE DESIGN CHECK LEONARD AMBROGI 03.04.2023 STATUS: ISSUED FOR CONSTRUCTION EDMS No:
by by by
REV VER
A1 Original Co-ordinate System: GDA2020/MGAZone56 Height Datum: A.H.D This sheet may be prepared using colour and may be incomplete if copied NOTE: Do not scale from this drawing. SYDNEY METRO
STRUCTURAL APPROVED CHRIS LAWTON 03.04.2023 DRG No.SMWSASBT-CPG-STM-SN100-TW-DRG-032902 00
BOGMATS MAY BE OMITTED.
PILE CONTRACTOR TO MARK BOGMATS MAY BE OMITTED. PILE
PILE LOCATION ON SITE. CONTRACTOR TO MARK PILE
CRANE TO BE CENTRED ON LOCATION ON SITE. CRANE TO BE
PILES CENTRED ON PILES

CRANE OUTRIGGER

B1 B2
AxB LONG
B1 B2 DIMENSION B IS LENGTH INTO PAGE
AxB LONG
DIMENSION B IS LENGTH INTO PAGE

2800 7700 2800 6200

10500 9000
RETENTION WALL PILE BY OTHERS

RETENTION WALL PILE BY OTHERS


200 THICK TYPE 3 RIGID

P1
PAVEMENT. PROVIDE MOVEMENT
JOINT AT CRANE BEAMS

C
C
P1

LOAD CASE 2
SCALE 1 : 50
LOAD CASE 1 60t MAX OUTRIGGER LOADING
SCALE 1 : 50
125t MAX OUTRIGGER LOADING PROVIDE 8m EXCLUSIVE ZONE
DURING CRAWLER CRANE USE
CRANE OUTRIGGER LOADING SURCHARGE ON RETENTION SYSTEM
CRANE LENGTH (mm) POINT LOAD A (mm) B (mm) PRESSURE (kPa)

GMK6400 10500 125t 2200 3000 190

File Path: Autodesk Docs://CPB_SM-WSA-SBT Delivery/SMWSASBT-CPG-STM-SN100-TW-M3D-030701.rvt


LTM1100-4.2 9000 60t 1500 2000 200

B1 B2
100mm AT FULL SIZE Plot Date & Time 3/04/2023 11:45:30 AM

B2 FOOTING REQUIRED
2800 4150 FOR CRAWLER CRANE
ONLY

6950
RETENTION WALL PILE BY OTHERS

P1

LOAD CASE 3
SCALE 1 : 50
100t MAX OUTRIGGER LOADING
C

OFFICIAL APPROVED FOR CONSTRUCTION


SCALES: 1:50 CLIENT The information shown on this drawing is for the purposes of the Sydney Metro Project only. No warranty is given or implied as to its suitability for any
other purpose. The Service Providers accept no liability arising from the use of this drawing and the information shown thereon for any purpose other
than the Sydney Metro Project.
SYDNEY METRO - WESTERN SYDNEY AIRPORT – STATION BOXES AND TUNNELLING WORKS
SN100 - ST MARYS METRO STATION
DRAWN ANOJ KHADKA 03.04.2023 TEMPORARY WORKS
DESIGNED KERROD POTTER 03.04.2023
LOAD CASES
00 APPROVED FOR CONSTRUCTION KP LA CL 03.04.23 DRG CHECK ROCCO CALARCO 03.04.2023
500 0 500 1000 1500 2000 FILE No: SMWSASBT-CPG-STM-SN100-TU-M3D-011505.rvt SHEET: 3 OF 4 C
REV. AMENDED DESCRIPTION Design Verified Approved Date
1:50 @ A1 mm BGE DESIGN CHECK LEONARD AMBROGI 03.04.2023 STATUS: ISSUED FOR CONSTRUCTION EDMS No:
by by by
REV VER
A1 Original Co-ordinate System: GDA2020/MGAZone56 Height Datum: A.H.D This sheet may be prepared using colour and may be incomplete if copied NOTE: Do not scale from this drawing. SYDNEY METRO
STRUCTURAL APPROVED CHRIS LAWTON 03.04.2023 DRG No.SMWSASBT-CPG-STM-SN100-TW-DRG-032903 00
N16-250 U-BARS TOP C PILE / BEAM
1800
12 N20 TOP

350
N16-250 U-BARS TOP C PILE / BEAM
1800
6 N20 TOP

500
N16-250 TIES

500
N16-250 TIES

EMBEDMENT
50 BLINDING LAYER N36-1000 SPACER BARS
50
2 ROWS OF 12 N36 BUNDLED BARS BTM
(24 TOTAL)
50 BLINDING LAYER 12N28 BTM
DOUBLE TURN OF HELIX
TOP AND BTM

TYPICAL B2 BEAM DETAIL


SCALE 1 : 10
N12-300 HELIX TIES

10N28

File Path: Autodesk Docs://CPB_SM-WSA-SBT Delivery/SMWSASBT-CPG-STM-SN100-TW-M3D-030701.rvt


750 DIA.

135 HOOK BEND OF


WELDED SPLICE TO
AS1554.3
100mm AT FULL SIZE Plot Date & Time 3/04/2023 11:45:42 AM

.
DIA
0 C PILE
75

10N28

C PILE

TYPICAL B1 BEAM DETAIL TYPICAL PILE SECTION


SCALE 1 : 10 SCALE 1 : 10

OFFICIAL APPROVED FOR CONSTRUCTION


SCALES: 1:10 CLIENT The information shown on this drawing is for the purposes of the Sydney Metro Project only. No warranty is given or implied as to its suitability for any
other purpose. The Service Providers accept no liability arising from the use of this drawing and the information shown thereon for any purpose other
than the Sydney Metro Project.
SYDNEY METRO - WESTERN SYDNEY AIRPORT – STATION BOXES AND TUNNELLING WORKS
SN100 - ST MARYS METRO STATION
DRAWN ANOJ KHADKA 03.04.2023 TEMPORARY WORKS
DESIGNED KERROD POTTER 03.04.2023
DETAILS
00 APPROVED FOR CONSTRUCTION KP LA CL 03.04.23 DRG CHECK ROCCO CALARCO 03.04.2023
100 0 100 200 300 400 FILE No: SMWSASBT-CPG-STM-SN100-TU-M3D-011505.rvt SHEET: 4 OF 4 C
REV. AMENDED DESCRIPTION Design Verified Approved Date
1:10 @ A1 mm BGE DESIGN CHECK LEONARD AMBROGI 03.04.2023 STATUS: ISSUED FOR CONSTRUCTION EDMS No:
by by by
REV VER
A1 Original Co-ordinate System: GDA2020/MGAZone56 Height Datum: A.H.D This sheet may be prepared using colour and may be incomplete if copied NOTE: Do not scale from this drawing. SYDNEY METRO
STRUCTURAL APPROVED CHRIS LAWTON 03.04.2023 DRG No.SMWSASBT-CPG-STM-SN100-TW-DRG-032904 00