The Photometer 5010 V5+ is a semi-automated photometric system with an LED light source and flexible cuvette concept. It has effective temperature regulation, minimal sample volume requirements, and can be upgraded via its future-proof operating system. Methods are programmable via the touchscreen and it stores up to 1000 results with graphics display and integrated thermal printer.
The Photometer 5010 V5+ is a semi-automated photometric system with an LED light source and flexible cuvette concept. It has effective temperature regulation, minimal sample volume requirements, and can be upgraded via its future-proof operating system. Methods are programmable via the touchscreen and it stores up to 1000 results with graphics display and integrated thermal printer.
The Photometer 5010 V5+ is a semi-automated photometric system with an LED light source and flexible cuvette concept. It has effective temperature regulation, minimal sample volume requirements, and can be upgraded via its future-proof operating system. Methods are programmable via the touchscreen and it stores up to 1000 results with graphics display and integrated thermal printer.
The Photometer 5010 V5+ is a semi-automated photometric system with an LED light source and flexible cuvette concept. It has effective temperature regulation, minimal sample volume requirements, and can be upgraded via its future-proof operating system. Methods are programmable via the touchscreen and it stores up to 1000 results with graphics display and integrated thermal printer.
· Effective temperature regulation system · Flexible cuvette concept, interchangeable flow-through or standard cuvette · Teach-in capability for reagent applications via touchscreen · Minimal sipping volume 250 µl · Double-secured liquid control with infrared bubble detector · Future-proof operating system can easily be upgraded ROBERT RIELE GmbH & Co KG Kurfuerstenstrasse 75-79 13467 Berlin Germany Tel: +49 (0)30 404 40 87
Photometer 5010 V5+ Fax: +49 (0)30 404 05 29
e-mail: info@riele.de www.riele.de
Type Sipping Volume Measurement Procedures
Semi-automatic, single-beam filter photometer • Minimum 250 µl, typically 500 µl up to 2000 • Absorbance • Separate setting of aspirate volume and • End point with factor, standard or multiple Light Source wash volume standards, with or without reagent blank LED with long lifetime and/or sample blank Operator Interface • Bichromatic end point Wavelength Touchscreen for direct functions and alpha- • Kinetics with factor, standard or multiple 340 nm and 390 nm - 730 nm numerical inputs standards,with or without blank • Fixed time with factor, standard or multiple Wavelength Selection Data Presentation standards, with or without reagent blank Automatic via 9-position filter wheel : 6 standard Graphic display: White characters or sym- •Turbidimetry with optional timer function interference filters: 340 nm, 405 nm, 492 nm, bols, blue background, lighted, resolution • Single, double and triple determinations 546 nm, 578 nm, and 623 nm; 3 positions for 240 x 128 dots • Curve fitting for nonlinear standard curves optional filters of choice • Free hemoglobin in combination with Integrated Printer optional interference filters Photometric Range Thermal printer, 24 characters per line 0 - 2.5 A Quality Control Languages Up to 50 methods can be controlled with two Cuvette System English and French/ German/ Indonesian/ control serums, Levey Jennings plot Micro flow cell: 32 μl, 10 mm light path inter- Russian/ Spanish changeable with normal standard cuvettes Measuring Time (macro or semi-micro, disposable or special Memory • Kinetic: variable from 3 – 19 deltas, optical glass) • General operating software can be updated time per delta 3 - 255 s by PC • Fixed time: variable from 0 - 1800 s Temperature Control • Reagent-open system with capacity for up • Internal Peltier element, temperature variable, to 231 programmable methods Delay Time pre-adjusted to 25 °C, 30 °C and 37 °C • Data import by touchscreen or PC Programmable from 0 - 1800 s • Equilibration time for aspirated reaction • Up to 50 nonlinear calibration curves with mixture to reach 37 °C from ambient max. 20 sets of points can be stored Mains Supply temperature: 15 s Range: 100 VAC up to 240 VAC at 50/60 Hz Signal Port Aspiration System Serial port for connection to an external Dimensions Built-in peristaltic pump driven by stepper motor, printer and/or PC Length 33 cm x width 34 cm x height 18 cm programmable aspiration volume controlled by infrared light barrier Data Logging Weight Up to 1000 results can be saved in the 5.0 kg memory automatically Marking