CH1-5 ( Status )
CH1-5 ( Feedback ) – EOS Out - Green if the actuator connected is a position End Of
Stroke, Out (= positioned at maximum stroke length)
Analog - No indication when operation is OK.
NOTE: Only operational with use of LA27 Analog encoded ( ‘A’ ) Run Out - Actuator is running out
Is red if measured voltage is illegal, i.e. Voltage < 25mV or voltage
> 3275mV. Illegal voltage area will result in fatal error if detected Run IN - Actuator is running in
on a running channel.
EOS IN - Green if the actuator connected is a position End Of
Hall - No indication when operation is OK. Stroke, In (= positioned at minimum stroke length)
Is red if a balance failure is detected. Balance failure are detected
in case the difference between amount of counted pulses from
the Hall A and the Hall B sensor.
Diagnosis, Page 2: Illustrates LINAK standard covers and which
buttons are active on OPENBUSTM
EXAMPLES: