Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

Nanjing Clover Medical Technology Co., Ltd.

Medical Waste Incinerator


Capacity: Average 100-150 kgs per hour

(0.8-1.2Ton/Day, as 8h/d)

Nanjing Clover Medical Technology Co., Ltd.

Nov, 9th, 2021

1
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Recommendation Product & Model

As the request of customer’s documents/email, we proposal

average capacity of average 100-150 kgs per hour for medical

waste incineration. The model is YD-100. The fuel is diesel oil or

gas.

Incinerator Model YD-100, Overview

This model is small-scale waste incineration equipment for large

waste output. Construction is dual/double combustion chamber

with 02 units oil burner, batch load incineration equipment. Waste

feed chamber is 1200Liters (1.2m3, YD-100). Primary & Secondary

combustion chambers and included mix-combustion chamber,

smoke filter chamber and Refractory Concrete chamber. Batch

load on the bottom of chamber. Incinerator panel control suit for

local operation.

7
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Incinerator Progress Principle

YD-100
Incinerator Process Priniciple

8
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Incinerator Structure

Model YD-100
Incinerator Structure

Mix&Secondary
Smoke Filter Chamber Incinerator Control Case Italy Oil/Gas Burner
Combustion Chamber

9
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Technology Respond(FAQ)

Q: what is kind of waste can use in this equipment?


A: This equipment for medical waste, pet animal, Municipal waste, live waste.
Prohibit any explosive and radiation material, liquid waste and gas waste.

Q: Incinerator Smoke Standard


A: China Government Standard: No.GB18484-2001.

Q: Treatment capacity
A: Average Capacity calculated by medical waste(lower calorific power
(L.C.P): 3.0TH Kcal/Kg per hour), not mean any waste material. The
animal/pet combustion rate around 2/3 of average capacity.

Clover incinerator use time per day up to 24 hours. Between each


feed/combustion time, there are about 0.5-1 hours cooling time and time for
feeding waste. Actual combustion time per day is around 16 hours. The
lifetime of incinerator between 5-10 year according to use.

Generally, we proposal small laboratory, small clinic use capacity under 20


kgs per hour. When incinerator use in hospital, please calculate the waste
output capacity around 2kgs per people per day. If there are 200 sickbed in
the hospital, that's mean you need one incinerator capacity around 400kgs
per day, change to capacity per hour is around 30-40 kgs per hour. According
the operation time per day, waste material, budget, development, etc, you
can use capacity from 30-50 kgs per hour incinerator.
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.

Q: Assembly and Testing


A: We supply all documents and incinerators easy to installation and
operation. Customer can send people come to our factory to learn
installation and operation. Generally, We do not send engineer to local site if
not request. The dispatch cost is extra according to order.

Q: Combustion Temperature
A: The first combustion chamber: 800-1000 centi degree.
The second combustion chamber: 1000-1200 centi degree.

Q: Incinerator Control Mode


10
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

A: Default Control mode is common control case. PLC mode according to


model and order.

Q: Operation and maintenance costs


A: Operation cost according to fuel consumption rate and power/staff, etc.

Annual around $500-$1000usd per year maintenance according model, use


situation.

One person can service 02 unit incinerators. The staff should have basic
electrician knowledge to operate/inspect/maintaince
incinerator/burner/blower according to operation user guider, and know risk
of medical waste to protect worker self with necessary protection element.

Q: The Residency time in secondary combustion chamber


A: 02 sec.

11
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Photo of Incinerator

Model TS10(PLC) Model YD-50 Model YD-300

Model YD-30 Model YD-20C Model YD-30C

Model YD-300 Model YD-300 Model YD-100

12
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Product Description & Technology

Clover incinerator exert the advantages and discard the disadvantages of the
same kind of equipment at domestic and abroad. It is an unique and
international advanced medical waste incineration equipment. The
equipment is small size, high efficiency, reasonable process, leading
technologies and a high harmless degree, ideal garbage treatment equipment
for hospital, laboratory, hotel, station, etc.

Main Characteristics:
1, Using fever of gasifying unites burning technology. It applied to burn
various kinds of medical waste, such as syringes, infusion set, disposable
dressing, and also small animal, some city waste, like paper, tree leaves.
2, Closed vacuum-wide operation, applicable to treat infectious medical
waste and to prevent secondary pollution.
3, Whole design, easy to transfer to different place.
4, Combustion burner from China or Italy.

14
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Product Specification Technology

HICLOVER YD100(PLC)

Incinerator Items/Model

Burn Rate (Average) 100-150 kg/hour

Feed Capacity(Average) 240kg/feeding

Control Mode PLC Automatic

Primary Combustion Chamber 1200L(1.2M3)

Internal Dimensions 130x100x90cm

Secondary Chamber 500L

Smoke Filter Chamber Yes

Feed Mode Manual

Voltage 220V 2P

Power 0.9Kw

Burner Type Italy Brand

Oil Consumption (kg/hour) 16

N.Gas Consumption (m3n/hour) ***

Temperature Monitor Yes

Temperature Thermometer Corundum Probe Tube, 1400℃Rate.

15
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Temperature Protection Yes

Automatic Cooling Yes

Automatic False Alarm Yes

System Testing Model Yes

Time Setting Yes

Progress Display Bar LCD Display

Oil Tank 200L

Oil Tank Stand 190cm Height

Liquid level Display Yes

Feeding Door 60x70cm

Chimney 10Meter

Chimney Type Stainless Steel 304

1st. Chamber Temperature 800℃--1000℃

2nd. Chamber Temperature 1000℃-1300℃

Residency Time 2.0 Sec.

Gross Weight 6000kg

External Dimensions 220 x 180 x 360cm

Thickness: ≥115 mm

1st. Chamber Composition Hot Face 55% of Al203

1750°C Grade

16
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com
Nanjing Clover Medical Technology Co., Ltd. Quotation Document

Thickness: ≥200 mm

2nd. Chamber Composition Hot Face 75% of Al203

1790°C Grade

Chamber Cold Face Material High Rate Refractory Ceramic Fiber

Other Parts Hot Face Refractory Heavy Duty with steel fiber

Burner operation Automatic On/Off

Dry Scrubber Including

Wet Scrubber Optional

Top Loading Door Optional

Paint for outside face 250°C Grade

Sealing Material Refractory Ceramic Fiber

Upgrade Containerized Mobile Type none

CE Certificate CE(2006/42/EC,2014/30/EU

ISO Certificate ISO9001:2015

High-tech Enterprise Certificate Yes

17
Nanjing Clover Medical Technology Co., Ltd.

Tel: +86-25-84610201 Fax: +86-25-84610406


Website: www.clover-incinerator.com Email: sales@clover-incinerator.com

You might also like