Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

LIT50-48S

48V 50Ah/2400Wh
Lithium Series

132±3
44
1.5
±3

443±3

32 kg
Approx

Technical Dimensions (mm)

132±3

441.5±3

472±3

443±3

483.5±3

Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk LIT-V1-REV3 06/21
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
LIT50-48S (Without Display) LIT50-48S (With Display)

*Optional LCD Display Screen Available.

Technical Specification
Output Nominal Voltage 48V
Nominal Capacity (5HR) 50Ah
Energy 2400Wh
Container Material Container Material Black baked Lacquer Steel Case (rack / cabinet is optional)
Flame Retardant Option (FR) UL94:VO
IP Class IP30
Standard Charge Charge Voltage 54V
Max. Charge Current 50A
Standard Discharge Max. Discharge Current 50A
Discharge Cut-off Voltage 40.5V

Discharge Characteristics Operating Temperature Charging: 0 ~ 45°C


Discharging: -20 ~ 60°C
Storage: -20 ~ 60°C
LIT50-48S
48V 50Ah/2400Wh
Lithium Series

Connections Parallel connection is optional. (up to 16P)


RS232, RS485

Containing Cell 3.2V 50Ah

Cycle Life More than 3500 cycles at 100% DOD.

Battery Management System Complete with BMS unit measuring current, voltage, single cell surface temperature and the ambient
temperature of the battery. It offers four remote functions which can communicate with a far-end central control
center by computer management.

Self Discharge
Ultracell® LIT batteries may be stored for up to 2 years at 25°C and then a refresh charge is required. For higher
temperatures the time intervals will be shorter.

Transportation
Ultracell® LIT Batteries will be at 30% State of Charge when shipped in accordance to the applicable international and
national government regulations. To prevent damage during transit, ensure packaging is safe and secure. Keep
battery dry and away from direct sunlight. Suitable for all transportation vehicles.
EMC 1188-C

Constant Current Discharge / Constant Power Discharge At 25°C (Amperes & Watts/Cell)
A = Amperes W = Watts
IEC 60896
IEC 62321 End of Discharge 60 2 3 4 5 10
Voltage 40.5V min hours hours hours hours hours

A 47.5 24.0 16.6 12.5 10 5

W 2400 1205 805 605 484 243

Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk LIT-V1-REV3 06/21
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
DOD in Relation to Cycle Life (25°C) 100% DOD Cycle Curves at Different Temperatures

20000 100
Standard Type 1C/1C at 80% DOD @ 25°C
98 1C/1C at 100% DOD @ 25°C
C Type
1C/1C at 80% DOD @ 45°C
16000 96 1C/1C at 100% DOD @ 45°C

94

Number of Cycles

Rated Capacity
12000 92

90

8000 88

86

4000 84

82
Charge/discharge current: 1.0C(A)

0 80
0% 20% 40% 60% 80% 100% 0 500 1000 1500 2000 2500 3000 3500

Depth of Discharge (DOD) Number of Cycles

Temperature Effect in Relation to Battery Capacity Discharge Time in Relation to Discharge Rate (25°C)

120 55
100%DOD and Charge/Discharge Current: 0.2C(A)
110
53

100

51
Capacity (%)

Voltage (V)
90

49
80

70 47

60

1C 0.5C 0.33C 0.2C 0.1C


LIT50-48S
48V 50Ah/2400Wh
Lithium Series

50
-30 -20 -10 0 10 20 30 40 50 60 70 0 120 240 360 480 600 720

Temperature (°C) Discharge Time (min)

Discharge Capacity in Relation to Discharge Rate

55
0.33C
0.5C
50 1C

45
Voltage (V)

40

35

30

25
0 20 40 60 80 100 120
EMC 1188-C

Capacity (Ah)

IEC 60896
IEC 62321

Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk LIT-V1-REV3 06/21
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

You might also like