Sikafloor®-3240
2-PART PUR TOUGH-ELASTIC, LOW-VOC, SELF SMOOTHING FLOOR
PRODUCT INFORMATION
1/4
Composition Polyurethane (PUR)
Packaging Part A 20.25 kg containers
Part B 4.75 kg containers
Part A+B 25.0 kg ready to mix units
Solid content
Solid content by weight ~100 %
Solid content by volume ~100 %
TECHNICAL INFORMATION
Shore D Hardness ~ 60 (7 days/23 °C/50 % r.h.) (DIN 53505)
Tensile Strength ~ 14 N/mm2 (14 days/23 °C/50 % r.h.) (DIN EN ISO 527-2)
Chemical Resistance Resistant to many chemicals. Contact Sika technical service for specific in-
formation.
SYSTEMS
Systems Please refer to the System Data Sheet of:
Sikafloor® MultiFlex PS-32 Smooth unicolour tough elastic poly-
urethane floor covering
Sikafloor® MultiFlex PS-32 UV Smooth unicolour tough elastic poly-
urethane floor covering with UV
sealer
Sikafloor® MultiFlex PB-32 Broadcast unicolour tough elastic
polyurethane floor covering
Sikafloor® MultiFlex PB-32 UV Broadcast unicolour tough elastic
polyurethane floor covering with UV
sealer
APPLICATION INFORMATION
Mixing Ratio Part A : Part B = 81 : 19 (by weight)
Consumption Please refer to the System Data Sheets
Ambient Air Temperature +10 °C min. / +30 °C max.
2/4
Relative Air Humidity ~ 75 - 80 %
Dew Point Beware of condensation!
The substrate and uncured floor must be at least 3 °C above dew point to
reduce the risk of condensation or blooming on the floor finish.
Substrate Temperature +10 °C min. / +30 °C max.
Substrate Moisture Content < 4 % pbw moisture content.
Test method: Sika®-Tramex meter, CM - measurement or Oven-dry-meth-
od. No rising moisture according to ASTM (Polyethylene-sheet).
Pot Life Temperatures Time
+10 °C ~ 40 minutes
+20 °C ~ 30 minutes
+30 °C ~ 20 minutes
Applied Product Ready for Use Temperature Foot traffic Light traffic Full Cure
+10 °C 1 day 3 days 9 days
+20 °C 12 hours 2 days 5 days
+30 °C 8 hours 1 day 3 days
Note: Times are approximate and will be affected by changing ambient conditions
3/4
IMPORTANT CONSIDERATIONS ECOLOGY, HEALTH AND SAFETY
▪ Colour variations are un-avoidable due to raw mater- For information and advice on the safe handling, stor-
ials. It can occur with quartz sand in bright shades age and disposal of chemical products, users shall
such as yellow or orange where colour variations refer to the most recent Material Safety Data Sheet
through the backfill may be visible. With these col- containing physical, ecological, toxicological and other
ours, the opacity is limited if the product is used as a safety-related data.
top coat. Applying a reference area is strongly re-
commended. DIRECTIVE 2004/42/CE LIMITATION OF EMISSIONS OF
▪ Under UV and weathering changes in colour are pos- VOC
sible. For colour matching, ensure Sikafloor®-3240
components A and B are applied from the same con- According to the EU-Directive 2004/42, the maximum
trol batch numbers. allowed content of VOC (Product category IIA / j type
▪ Do not apply Sikafloor®-3240 on substrates with sb) is 500 g/l (Limits 2010) for the ready to use
rising moisture. product.
▪ Do not apply on substrate surfaces with a slope > 1 The maximum content of Sikafloor®-3240 is < 500 g/l
%. VOC for the ready to use product.
▪ Freshly applied Sikafloor®-3240 must be protected
from damp, condensation and water for at least 24 LEGAL NOTES
hours. Uncured material reacts in contact with water
(foaming). During application care must be taken The information, and, in particular, the recommenda-
that no ‘sweat’ drops into fresh Sikafloor®-3240 tions relating to the application and end-use of Sika
(wear head and wrist bands). products, are given in good faith based on Sika’s cur-
▪ The incorrect assessment and treatment of cracks rent knowledge and experience of the products when
may lead to a reduced service life and reflective properly stored, handled and applied under normal
cracking. conditions in accordance with Sika’s recommenda-
▪ In smooth applications with sun light exposure use tions. In practice, the differences in materials, sub-
Sikafloor®-357 N or Sikafloor®- 305W as seal coat. strates and actual site conditions are such that no war-
▪ Under certain conditions, under floor heating or high ranty in respect of merchantability or of fitness for a
ambient temperatures combined with high point particular purpose, nor any liability arising out of any
loading, may lead to imprints in the resin. legal relationship whatsoever, can be inferred either
▪ If during application temporary heating is required from this information, or from any written recom-
do not use gas, oil, paraffin or other fossil fuel heat- mendations, or from any other advice offered. The
ers, these produce large quantities of both CO2 and H user of the product must test the product’s suitability
2O water vapour, which may adversely affect the fin- for the intended application and purpose. Sika re-
ish. For heating use only electric powered warm air serves the right to change the properties of its
blower systems. products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
BASIS OF PRODUCT DATA current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product
All technical data stated in this Product Data Sheet are Data Sheet for the product concerned, copies of which
based on laboratory tests. Actual measured data may will be supplied on request.
vary due to circumstances beyond our control.
LOCAL RESTRICTIONS
Please note that as a result of specific local regulations
the performance of this product may vary from coun-
try to country. Please consult the local Product Data
Sheet for the exact description of the application
fields.
Sikafloor-3240-en-TH-(01-2020)-2-2.pdf
4/4