Vendor’s name : Southern Renewable Energy Co., Ltd.

Owner’s Name : Vietnam Nisshin Technomic

Purchaser : JGC Vietnam Co., Ltd.

Plant Location : Bien Hoa City, Dong Nai Province, Vietnam

Project Name : Vietnam Nisshin Technomic Phase 2

P / Order No. : P-2155-114-A

Equipment/Material Name: Waste Heat Recovery Heat Exchanger

Item Number : HX399

Document Title : Inspection and test plan (ITP)

Vietnam Nisshin Technomic Phase 2 Project


(JOB No.: 0-8850-20)
DOCUMENT CLASS: 2

ISSUE PURPOSE: FC

RESULT CODE: A, B, R B

NEXT STATUS: FA, FI, FC, AB FC

RESUBMISSION DATE:

NEXTSUBMISSION DATE: 19-Sep-2022

RESPONSIBLE DEPT./PERSON: MEC\M.V.Binh

Review Date: 12-Sep-2022

A: Approvedwithout Comment; B: Approvedwith Minor Comment

R: Not Approvedwith Comments


Approval or review hereunder shall not be construedto relieve Supplier / Subcontractor of his

responsibilities andliability under the Contract.

Purchaser ORIG. PURCHASE ORDER NO. SERIAL REV.

DOC. No. V- 2155 - 114 - A - 601 2


WASTE HEAT RECOVERY EXCHANGER

INSPECTION AND TEST PLAN

Inspection point
No. Name of parts Supervision Content Inspection point

Vendor JGC Owner

1. Raw material guarantee and reinspection report V R R


See note

2. Main weld appearance inspection See note V R R

3. Size and appearance inspection See note V W R

4. NDT report on welds See note V R R


Waste Heat
1 Recovery
Exchanger
5. Coating inspection See note V R R

6. Leak Test inspection See note V H R

7. Final inspection (Pakaging) See note V R R

packaging

8. Open box inspection See note R H W R

V: Vendor shall perform the test or inspection itself

H: Vendor shall notify purchaser of inspection date and time. Vendor is not allowed to proceed with the tests or

inspection unless a written release is issued by the Purchaser's inspector

R: Purchaser reviews the Vendor inspection records and Certificates

W: Vendor shall invite Purchser to witness that inspection work

Note: the inspection point are specified in the Inspection/Test Procedure V-2155-114-A-600

purchaser