Fit Statistics

Std. Dev. 0.9432 R² 0.9986


Mean 88.67 Adjusted 0.9927

A negative Predicted R² implies that the
C.V. % 1.06 Predicted -29.5911
R² overall mean may be a better predictor of
Adeq 36.7805 your response than the current model. In
Precision
some cases, a higher order model may also
predict better.

Adeq Precision measures the signal to noise ratio. A ratio greater than 4 is desirable. Your ratio
of 36.780 indicates an adequate signal. This model can be used to navigate the design space.

ANOVA for Cubic model (Aliased)

Response 1: % Removal

Source Sum of Squares df Mean Square F-value p-value


Model 3768.46 25 150.74 169.44 < significant
0.0001
A-Time 0.7080 1 0.7080 0.7959 0.4067
B- 144.16 1 144.16 162.05 <
Temperature 0.0001
C-pH 0.1458 1 0.1458 0.1639 0.6996
D-Adsorbate 53.77 1 53.77 60.44 0.0002
E-Adsorbent 0.4324 1 0.4324 0.4861 0.5118
AB 44.72 1 44.72 50.27 0.0004
AC 1.22 1 1.22 1.37 0.2868
AD 54.87 1 54.87 61.68 0.0002
AE 13.63 1 13.63 15.33 0.0078
BC 49.04 1 49.04 55.12 0.0003
BD 94.14 1 94.14 105.82 <
0.0001
BE 490.29 1 490.29 551.13 <
0.0001
CD 30.28 1 30.28 34.03 0.0011
CE 95.01 1 95.01 106.80 <
0.0001
DE 11.41 1 11.41 12.82 0.0116
A² 12.95 1 12.95 14.55 0.0088
B² 445.91 1 445.91 501.24 <
0.0001
C² 19.27 1 19.27 21.67 0.0035
D² 147.28 1 147.28 165.55 <
0.0001
E² 17.99 1 17.99 20.22 0.0041
ABC 0.0000 0
ABD 0.0000 0
ABE 0.0000 0
ACD 0.0000 0
ACE 0.0000 0
ADE 0.0000 0
BCD 0.0000 0
BCE 0.0000 0
BDE 0.0000 0
CDE 0.0000 0
A²B 418.65 1 418.65 470.60 <
0.0001
A²C 14.35 1 14.35 16.13 0.0070
A²D 76.96 1 76.96 86.51 <
0.0001
A²E 16.14 1 16.14 18.14 0.0053
AB² 0.7154 1 0.7154 0.8042 0.4044
AC² 0.0000 0
AD² 0.0000 0
AE² 0.0000 0
B²C 0.0000 0
B²D 0.0000 0
B²E 0.0000 0
BC² 0.0000 0
BD² 0.0000 0
BE² 0.0000 0
C²D 0.0000 0
C²E 0.0000 0
CD² 0.0000 0
CE² 0.0000 0
D²E 0.0000 0
DE² 0.0000 0
A³ 0.0000 0
B³ 0.0000 0
C³ 0.0000 0
D³ 0.0000 0
E³ 0.0000 0
Residual 5.34 6 0.8896
Lack of Fit 5.34 1 5.34
Pure Error 0.0000 5 0.0000
Cor Total 3773.80 31

Factor coding is Coded.


Sum of squares is Type III - Partial

The Model F-value of 169.44 implies the model is significant. There is only a 0.01% chance that
an F-value this large could occur due to noise.
P-values less than 0.0500 indicate model terms are significant. In this case B, D, AB, AD, AE,
BC, BD, BE, CD, CE, DE, A², B², C², D², E², A²B, A²C, A²D, A²E are significant model terms.
Values greater than 0.1000 indicate the model terms are not significant. If there are many
insignificant model terms (not counting those required to support hierarchy), model reduction
may improve your model.