Download as pdf or txt
Download as pdf or txt
You are on page 1of 44

2

YEARS
of GUARANTEE

201
L I N E A

ACCESS CONTROL SYSTEM

C ATA L O G U E
NOVEMBER 2005
A U D I O A N D V I D E O D

201
L I N E A
D O O R E N T R Y S Y S T E M S

CONTENTS
•Preparing a quotation 4
•Audio door entry Kits 6
•Video door entry Kits 8
•Audio door entry systemns 10
•4+N call system and electronic call 10
•4+N call system electronic call and buzzer call 11
•Audio door entry systems, 4+N microprocessor-based
call system, electronic or buzzer call and multiple access points 12
•Audio door entry systems, 4+N microprocessor-based
call system, electronic call, privacy of conversation and simple
and multiple access points 13
•4+N Microprocessor-based call system, electronic call, and
internal communication system 14
•Digial audio door entry system 16
•Digital audio door Entry System, with electronic call, privacy of
conversation and multiple access points 16
•Video door entry system 19
•Video Door Entry System, Microprocessor-based 6+N and coaxial call system,
electronic call, privacy of conversation, simple and multiple access points 19
•Video Door Entry System, Microprocessor-based 6+N and Twisted Pair System,
Electronic call, Privacy of conversation, simple and multiple access points 21
•Digital video door entry system 24
•Digital Video Door Entry System, Microprocessor-based,
electronic call, privacy of conversation, simple and multiple access points 24
•Digital video door entry system, microprocessor-based, twisted pair system,
electronic call, privacy of conversation, simple and multiple access points 27
•TV door entry system 30
•Video door PC 31
•Accessories 32
•Entrance panel modules with push-buttons 32
•Accessories for entrance panels 34
•Accesories 38
•Universal electronic products 39
•Cables for electronic door entry system 39
•Measures 40
•General terms 43
P R E P A R I N G A

This catalogue is designed to help you prepare a quotation for an installation in a sim-
ple manner for the following types of systems:
Electronic door entry system:
•4+N call system with electronic call
•4+N call system with buzzer call
•4+N call system with electronic call and privacy of conversation
•4+N microprocessor-based call system (multiple access) with electronic call
•4+N microprocessor-based call system (multiple access) with electronic call
and privacy of conversation
•Digital system with electronic call and privacy of conversation
•Digital system (multiple access) with electronic call and privacy of conversation
Video door entry system:
•6+N microprocessor-based coaxial system, with electronic call and privacy
of conversation
•6+N microprocessor-based coaxial system, (multiple access) with electronic call
and privacy of conversation
•Digital system with electronic call and privacy of conversation
•Digital system (multiple access) with electronic call and privacy of conversation
It is important to note that our entrance panels always consist of two modules: an
entrance panel module with the audio unit, video unit, card holder or blank, and a
push-button entrance module.

To prepare a quotation you should bear in mind:

•The catalogue is divided as follows:

•Kits

•Door entry systems

•Video door entry systems

ALCAD - 4
A Q U O T A T I O N

•Accessories

•In the chapters concerning door and video door entry systems, you will find all
items required for different types of installations, besides sample quotations and
example wiring diagram.
5 5

TYPE
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6
TEL-001 TEL-001
(9600001) (9600001)
TEL-001 3 6 8 10 12 12 15 18 16 20 24
MAN-010 1 1 1 1 1 1 1 1 1 1 1 5 5
MLN-000 1 1 1 1 1 1
MPS-003 1
MPS-004 1
MPS-005 1
MPS-006 1 4+N
MPD-003 1 TEL-001
(9600001)
TEL-001
(9600001)
MPD-004 1 1 2 ALA-040
(9620001)
MPD-005 1 1 2
MPD-006 1 1 2 2
ALA-040 1 1 1 1 1 1 1 1 1 1 1 MAN-010
(9670001)
CEM-001 1 1 1 1 1 1 230 V V

CMO-004 1 1 1 2 2 MPD-003
(9660050)
CMO-006 1 1 2 2 2 2 2

ABR-001 1 1 1 1 1 1 1 1 1 1 1

ABR-001
(9730000)

•In the chapter of "accessories" you will find all commun items to the different
types of installations. You will also find in this chapter, Universal electronic pro-
ducts, for the maintenance of installations.

•For the door entry systems, 4+N call system and electronic call in buildings
of 6 or more floors and the video door entry systems for one or two access
points, you can prepare your quotation using the KITS, were all required items
to enable the installation described in the noted paragraph are included.
•To see the dimensions of all the products go to the section DIMENSIONS
(page 40).

ALCAD - 5
K I T S

AUDIO DOOR ENTRY KITS, 4+N CALL SYSTEM, WITH ELECTRONIC CALL
•Containing all the necessary products (except for cable) for the installation
•High quality audio processing
•Compact entrance panel with audio unit and push-buttons
•Confirmation of call on entrance panel
•All the products of the kit are fully compatible with all other products in our catalogue

KITS WITH SINGLE PUSH-BUTTON

5
2 2 5

CODE TYPE DESCRIPTION PACK CODE TYPE DESCRIPTION PACK

9700018 KAS-01201 Kit for 1 single push- 9700000 KAS-01001 Kit for single push-button,
button, with 4+N call 11 with 4+ N call system 12
system without electric lock

5
5 9
7 2
2

2
2

CODE TYPE DESCRIPTION PACK CODE TYPE DESCRIPTION PACK

9700001 KAS-01003 Kit for 3 single push- 9700002 KAS-01005 Kit for 5 single push-
buttons, with 4+N 6 buttons, with 4+N 4
call system call system

KITS WITH DOUBLE PUSH-BUTTONS

5 5
5 5
2 6 6
2

CODE TYPE DESCRIPTION PACK CODE TYPE DESCRIPTION PACK

9700021 KAD-01201 Kit for 1 double push 9700003 KAD-01001 Kit for 1 double push-
button, 4+N call system 6 button, with 4+N 6
without electric lock call system

ALCAD - 6
K I T S

AUDIO DOOR ENTRY KITS, 4+N CALL SYSTEM, WITH ELECTRONIC CALL
KITS WITH DOUBLE PUSH-BUTTONS

5 5
10
8
2 2

2 2

CODE TYPE DESCRIPTION PACK CODE TYPE DESCRIPTION PACK

9700004 KAD-01002 Kit for 2 double push- 9700005 KAD-01003 Kit for 3 double push-
buttons, with 4+N call 6 buttons, with 4+N 4
system call system

KITS WITHOUT ELECTRIC LOCK - 127 Vac


CODE TYPE DESCRIPTION PACK
5

12 9700009 KAS-01101 Kit for 1 single push-button


and 4+N c.s, 127 Vac 12
2
9700010 KAS-01103 Kit for 3 single push-but-
tons and 4+N c.s, 127 Vac 6
2
9700011 KAS-01105 Kit for 5 single push-but-
tons and 4+N c.s, 127 Vac 4
CODE TYPE DESCRIPTION PACK
9700012 KAD-01101 Kit for 1 double push-
9700006 KAD-01004 Kit for 4 double push-
buttons, 127 Vac 6
buttons, with 4+N 2
call system 9700013 KAD-01102 Kit for 2 double push-
buttons, 127 Vac 6
9700014 KAD-01103 Kit for 3 double push-
buttons, 127 Vac 4
9700015 KAD-01104 Kit for 4 double push-
14
5 buttons, 127 Vac 2
2 9700016 KAD-01105 Kit for 5 double push-
buttons, 127 Vac 2
9700017 KAD-01106 Kit for 6 double push-
2
buttons, 127 Vac 2

CODE TYPE DESCRIPTION PACK

9700007 KAD-01005 Kit for 5 double push-


buttons, with 4+N 2 POWER SUPPLY UNITS - 110/127 Vac
call system CODE TYPE DESCRIPTION PACK

9620003 ALA-140 Power supply, electronic


door entry system,
110/127 Vac 15
9620004 ALA-120 Power supply for kit, elec-
5 tronic door entry system,
16
110/127 Vac 15
2
9620013 ALM-080 Power supply to release elec-
tric locks with high power
consumption, 110/127 Vac 9
2

CODE TYPE DESCRIPTION PACK

9700008 KAD-01006 Kit for 6 double push-


buttons, with 4+N 2
call system ALCAD - 7
K I T S

•Containing all the necessary products (except for cable) for the installation
•High quality audio and video processing (through the coaxial cable)
•Compact entrance panel with video unit, audio unit and push-buttons
•Confirmation of the call on the panel
•All the products of the kit are fully compatible with all other products in our catalogue

VIDEO DOOR ENTRY KITS, MICROPROCESSOR-BASED 6+N AND COAXIAL


SYSTEM, WITH ELECTRONIC CALL AND PRIVACY OF CONVERSATION

5 7+COAX
5 8+COAX

2 2

CODE TYPE DESCRIPTION PACK CODE TYPE DESCRIPTION PACK

9720000 KVS-08101 Kit with 1 single push-but- 9720002 KVD-08101 Kit with 1 double push-but-
ton, with 6+N call and coax 6 ton, with 6+N call and coax 4
system with B/W monitor system with B/W monitor

VIDEO DOOR ENTRY KITS, MICROPROCESSOR-BASED 6+N AND TWISTED


PAIR SYSTEM, WITH ELECTRONIC CALL AND PRIVACY OF CONVERSATION

5 7+ PAR TRENZADO
5 8+ PAR TRENZADO

2 2

CODE TYPE DESCRIPTION PACK CODE TYPE DESCRIPTION PACK

9720012 KVS-08401 Kit with 1 single push-but- 9720013 KVD-08401 Kit with 1 double push-but-
ton, with 6+N and twisted 6 ton, with 6+N call and twis- 4
pair system with B/W moni- ted pair system with B/W
tor monitor

ALCAD - 8
K I T S

DIGITAL VIDEO DOOR ENTRY KITS

5 4+COAX 5 4+COAX
5 4+COAX

2 2 2

CODE TYPE DESCRIPTION CODE TYPE DESCRIPTION CODE TYPE DESCRIPTION

9720004 KVS-09101 Kit with 1 single 9720005 KVD-09101 Kit with 1 double push- 9720009 KVS-09201 Digital video door entry
PACK push-button, 4 wires PACK button, 4 wires BUS and PACK Kit with 1 single push-but-
BUS and coaxial, coaxial, with B/W moni- ton, 4 wires BUS and coa-
with B/W monitor.
6 4 tor. 6 xial, with colour monitor

DIGITAL VIDEO DOOR ENTRY KITS AND TWISTED PAIR SYSTEM

5 4+PAR TRENZADO
5 4+PAR TRENZADO

2 2

CODE TYPE DESCRIPTION PACK CODE TYPE DESCRIPTION PACK

9720014 KVS-09401 Kit with 1 single push- 9720015 KVD-09401 Kit with 1 single push-
button, 4 wires BUS and 6 button, 4 wires BUS and 4
twisted pair, with B/W twisted pair, with B/W
monitor monitor

ALCAD - 9
A U D I O D O O R E

AUDIO DOOR ENTRY SYSTEM, 4+N CALL SYSTEM, ELECTRONIC CALL

TELEPHONES
CODE TYPE DESCRIPTION PACK
9600001 TEL-001 Telephone with electronic call 10/60
9600001
9600018 TEL-101 Customised telephone with electronic call 1/60
9600009 TEL-002 Telephone with electronic call, 2 push-buttons 10/60
9600009
ENTRANCE PANEL MODULES WITH AUDIO UNIT,
CARD HOLDER OR BLANK
CODE TYPE DESCRIPTION PACK

9670001 MAN-010 Entrance panel with 4+N audio unit and with electro-
nic call 12
9670001 9670022 9670022 MMN-010 Entrance panel with 4+N audio unit, with electronic
call and with card holder 9

9670018 MTN-000 Entrance panel with card holder 12


9670021 9670018 9670021 MLN-000 Blank entrance panel 12

POWER SUPPLY UNITS


CODE TYPE DESCRIPTION PACK
9620001 ALA-040 25 VA power supply, electronic door entry system 15
16 VA power supply unit for kit,
9620002 ALA-020 electronic door entry system 15
9620001

Entrance panel modules with push-buttons, accessories, cables, etc. see accessories page 32

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM


(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED BOX)

TYPE
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6 5 5

TEL-001 3 6 8 10 12 12 15 18 16 20 24 30 36 TEL-001 TEL-001


(9600001) (9600001)
MAN-010 1 1 1 1 1 1 1 1 1 1 1 1 1
MLN-000 1 1 1 1 1 1 2 2
MPS-003 1
MPS-004 1
5 5
MPS-005 1
MPS-006 1
MPD-003 1 TEL-001
(9600001)
TEL-001
(9600001)
MPD-004 1 1 2
MPD-005 1 1 2 3 4+N
MPD-006 1 1 2 3
ALA-040
ALA-040 1 1 1 1 1 1 1 1 1 1 1 1 1 (9620001)
CEM-001 1 1 1 1 1 1 2 2 SECTION TABLE
CMO-004 1 1 1 2 2 230 V V MAN-010
Up to 100 m
CMO-006 1 1 2 2 2 2 3 3 (9670001)
2
ABR-001 1 1 1 1 1 1 1 1 1 1 1 1 1 0,25 mm2 0,6 mm
2
1 mm2 1,1 mm
MPD-003
(9660050) Up to 25 m
0,5 mm2 0,8 mm
* installation for 2 dwellings per floor and 6 floors ABR-001
(9730000)

ALCAD - 10
E N T R Y S Y S T E M S

AUDIO DOOR ENTRY SYSTEMS, 4+N CALL SYSTEM AND BUZZER CALL

TELEPHONES
CODE TYPE DESCRIPTION PACK

9600002 TUN-001 Telephone with electronic or buzzer


call (Universal) 10/60
9600013 TUN-101 Customised Universal Telephone 1 push button 10/60
9600011 TUN-002 Universal Telephone with electronic or
9600002 9600011 buzzer call, 2 push buttons 10/60

ENTRANCE PANEL MODULES WITH AUDIO UNIT, CARD HOLDER OR BLANK


CODE TYPE DESCRIPTION PACK

9670008 MAN-051 Entrance panel with 4+N universal audio unit, with
electronic and buzzer call 12
9670024 9670018 9670024 MMN-051 Entrance panel with 4+N universal audio unit, with
electronic and buzzer call. With card-holder. 9
9670018 MTN-000 Entrance panel with card holder 12

9670021 MLN-000 Black entrance panel 12


9670021 9670008

POWER SUPPLY UNITS


CODE TYPE DESCRIPTION PACK
9620001 ALA-040 25 VA power supply, electronic door entry system 15

9620001 Entrance panel modules with push-buttons, accessories, cables, etc. See accessories page 32

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM


SINGLE ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED BOX)

*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6
TYPE 5 5 SECTION TABLE
TES-001 3 6 8 10 12 12 15 18 16 20 24 30 36 Up to 100 m

MAN-041 1 1 1 1 1 1 1 1 1 1 1 1 1 TUN-001
(9600002)
TUN-001
(9600002) 0,25 mm2 0,6 mm
MLN-000 1 1 1 1 1 1 2 2
1 mm2 1,1 mm
MPS-003 1 Up to 25 m
MPS-004 1 0,5 mm2 0,8 mm
5 5
MPS-005 1
MPS-006 1 TUN-001 TUN-001
MPD-003 1 (9600002) (9600002)

MPD-004 1 1 2 4+N
MPD-005 1 1 2 3 ALA-040
MPD-006 1 1 2 3 (9620001)

ALA-040 1 1 1 1 1 1 1 1 1 1 1 1 1
MAN-051
CEM-001 1 1 1 1 1 1 2 2
230 V V

(9670002)
2
CMO-004 1 1 1 2 2
2
CMO-006 1 1 2 2 2 2 3 3 MPD-003
(9660050)
ABR-001 1 1 1 1 1 1 1 1 1 1 1 1 1

ABR-001
(9730000)

* installation for 2 dwellings per floor and 6 floors

ALCAD - 11
A U D I O D O O R E

AUDIO DOOR ENTRY SYSTEMS, 4+N MICROPROCESSOR-BASED CALL SYSTEM, ELECTRONIC


OR BUZZER CALL AND MULTIPLE ACCESS POINTS
TELEPHONES
CODE TYPE DESCRIPTION PACK
9600001 TEL-001 Telephone with electronic call 10/60
9600018 TEL-101 Customised telephone with electronic call 1/60
9600009 TEL-002 Telephone with electronic call, 2 push-buttons 10/60
9600002 TUN-001 Telephone with electronic or buzzer call (universal) 10/60
9600001 9600009
9600013 TUN-101 Customised Universal Telephone 1 push button 10/60
9600011 TUN-002 Telephone with electronic or buzzer call, 2 push buttons 10/60
ENTRANCE PANEL MODULES WITH AUDIO UNIT, CARD HOLDER OR BLANK
CODE TYPE DESCRIPTION PACK
9670004 MAN-030 Entrance panel with microprocessor-based 4+N audio unit
with electronic call and miltiple access points 12
9670025 MMN-030 Entrance panel with microprocessor-based 4+N audio
unit with electronic call and miltiple access points. With
9680001 9680004 card-holder 9
9670018 MTN-000 Entrance panel with card holder 12
9670021 MLN-000 Blank entrance panel 12
9730005 AAL-001 Electronic to buzzer call adaptor 18
POWER SUPLY UNITS PACK
9670004 9670025 CODE TYPE DESCRIPTION
9670006 9620001 ALA-040 25 VA power supply, electronic door entry system 15

CONCIERGE
CODE TYPE DESCRIPTION PACK
9680001 COA-010 Telephone for concierge or reception for 9 or 10 rows 5
9670018 9670021
9680002 COA-012 Telephone for concierge or reception for 11 or 12 rows 5
9680003 COA-014 Telephone for concierge or reception for 13 or 14 rows 6
9680004 COA-016 Telephone for concierge or reception for 15 or 16 rows 6
9670006 MAN-060 Entrance panel with 4+N audio unit and with electro- 12
nic call for concierge
9620001
Entrance panel modules with push-buttons, accessories, cables, etc. See accesories page 32.
SAMPLE QUOATION EXAMPLE WIRING DIAGRAM
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED BOX

TYPE
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6
5 5
SECTION TABLE
Up to 100 m
TEL-001 3 6 8 10 12 12 15 18 16 20 24 30 36
TEL-001 TEL-001
MAN-030 2 2 2 2 2 2 2 2 2 2 2 2 2 (9600001) (9600001)
0,25 mm2 0,6 mm
MLN-000 2 2 2 2 2 2 4 4
1 mm2 1,1 mm
MPS-003 2
Up to 25 m
MPS-004 2
5 5 0,5 mm2 0,8 mm
MPS-005 2
MPS-006 2
TEL-001 TEL-001
MPD-003 2 (9600001) (9600001)

MPD-004 2 2 4
4+N
MPD-005 2 2 4 6
MPD-006 2 2 4 6 ALA-040
(9620001)
ALA-040
(9620001)
ALA-040 2 2 2 2 2 2 2 2 2 2 2 2 2 MAN-030
(9670004)
CEM-001 2 2 2 2 2 2 4 4 230 V V MAN-030 230 V V

CMO-004 2 2 2 4 4 (9670004)
2
2
CMO-006 2 2 4 4 4 4 6 6 6+N
2 2
ABR-001 2 2 2 2 2 2 2 2 2 2 2 2 2 MPD-004
(9660051)
MPD-004
(9660051)

ABR-001 ABR-001

* installation for 2 dwelling per floor and 6 floors (9730000) (9730000)

ALCAD - 12
E N T R Y S Y S T E M

AUDIO DOOR ENTRY SYSTEM, 4+N MICROPROCESSOR-BASED CALL SYSTEM, ELECTRONIC


CALL, PRIVACY OF CONVERSATION AND SIMPLE AND MULTIPLE ACCESS POINTS
TELEPHONES
CODE TYPE DECRIPTION PACK

9600003 TES-001 Telephone with electronic call and privacy of


conversation 10/60
9600012 TES-002 Telephone with electronic call and privacy of con-
versation. 2 Push-buttons 10/60
9600003 9600012

ENTRANCE PANEL MODULES WITH AUDIO UNIT, CARD HOLDER OR BLANK


CODE TYPE DESCRIPTION PACK

9670007 MAN-041 Entrance panel with microprocessor-based 4+N audio


unit with electronic call, privacy of coversation and mul-
tiple accesss points 12
9670007 9670097
9670097 MMN-041 Entrance panel with microprocessor-based 4+N audio
unit with electronic call, privacy of coversation and mul-
tiple accesss points with card-holder 9
9670018 MTN-000 Entrance panel with card-holder 12
9670018 9670021
9670021 MLN-000 Blank entrance panel 12

POWER SUPPLY UNITS


CODE TYPE DESCRIPTION PACK

9620001 ALA-040 25 VA power supply, electronic door entry system 15

Entrance panel modules with push-buttons, accessories, cables, etc. see accessories page 32

9620001

SAMPLE QUOATION EXAMPLE WIRING DIAGRAM


(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH
MOUNTED BOXES)

TYPE
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6
5 5
SECTION TABLE
Up to 100 m
TES-001 3 6 8 10 12 12 15 18 16 20 24 30 36
TES-001 TES-001
MAN-041 1 1 1 1 1 1 1 1 1 1 1 1 1 (9600003) (9600003) 0,25 mm2 0,6 mm
MLN-000 1 1 1 1 1 1 2 2 1 mm2 1,1 mm
MPS-003 1 Up to 25 m
MPS-004 1 0,5 mm2 0,8 mm
MPS-005 1 5 5

MPS-006 1
MPD-003 1 TES-001
(9600003)
TES-001
(9600003)
MPD-004 1 1 2
4+N
MPD-005 1 1 2 3
MPD-006 1 1 2 3 ALA-040
(9620001)
ALA-040 1 1 1 1 1 1 1 1 1 1 1 1 1
CEM-001 1 1 1 1 1 1 2 2
MAN-041
CMO-004 1 1 1 2 2 230 V V

(9670007)
CMO-006 1 1 2 2 2 2 3 3 2

ABR-001 1 1 1 1 1 1 1 1 1 1 1 1 1 2
MPD-003
(9660050)

* installation for 2 dwelling per floor and 6 floors


ABR-001
(9730000)

ALCAD - 13
A U D I O D O O R E

AUDIO DOOR ENTRY SYSTEM, 4+N CALL SYSTEM, ELECTRONIC CALL


AND INTERNAL COMMUNICATION SYSTEM

TELEPHONES
CODE TYPE DESCRIPTION PACK

9600001 TEL-001 Telephone with electronic call 10/60


9600001
9600009 TEL-002 Telephone with electronic call, 2 push-buttons 10/60
9600018 TEL-101 Customised telephone with electronic call 1/60
9600009

9600014

ENTRANCE PANELS WITH AUDIO UNIT, CARD HOLDER OR BLANK


CODE TYPE DESCRIPTION PACK
9670001 MAN-010 Entrance panel with microprocessor-based 4+N audio
9670001 9670022 unit with electronic call and multiple access points 12
9670025 MMN-010 Entrance panel with microprocessor-based 4+N audio unit,
with electronic call and multiple access points. With card-
holder 9

9670018 MTN-000 Entrance panel with card holder 12


9670021 9670018
9670021 MLN-000 Blank entrance panel 12

INTERNAL COMMUNICATION SYSTEM MODULE


CODE TYPE DESCRIPTION PACK
9650001 9
9650001 GCI-001 Control module for internal communication system

POWER SUPLY UNITS


CODE TYPE DESCRIPTION PACK

9620001 ALA-040 25VA power supply, electronic door entry system 15

Entrance panel modules with push-buttons, accesories, cables, eyc. see accessories page 32
9620001

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM

Nº OF DWELLINGS 2 5 10 16 TIN-001 TIN-001 TIN-001


(9600014) (9600014) (9600014)
TYPE
TIN-001 2 5 10 16
GCI-001 1 1 1 1 1
4
2
5
3
6
1 1
4
2
5
3
6
1 1
4
2
5
3
6
7 8 9 7 8 9 7 8 9
C 0 C 0 C 0

2 2

GCI-001
(9650001)
SECTIO TABLE
Up to 100 m
230 V I2 I1

0,25 mm2 0,6 mm


1 mm2 1,1 mm
ALCAD - 14
N T R Y S Y S T E M S

SAMPLE QUOTATION
EXAMPLE WIRING DIAGRAM
SIGLE ACCESS
TIN-001 TIN-001 TIN-001 TIN-001 SECTION TABLE
(9600014) (9600014) (9600014) (9600014)
1 1 1 To 100 m

5 5 5 5
0,25 mm2 0,6 mm
1 2 3 1 2 3 1 2 3 1 2 3
4 5 6 4 5 6 4 5 6 4 5 6
7 8 9 7 8 9 7 8 9 7 8 9
C 0 C 0 C 0 C 0

2 2 2 2 1 mm2 1,1 mm
To 25 m
Nº OF DWELLINGS 2 5 10 16
TYPE 0,5 mm2 0,8 mm
TIN-001 2 5 10 16 ALA-040 GCI-001
(9620001) (9650001)
MAN-010 1 1 1 1 2
MPS-001 1 1 1 1
ALA-040 MAN-010
1 1 1 1 230 V V

(9670001)
230 V I2 I1

GCI-001 2
1 1 1 1
CMO-002 1 1 1 1 2 MPS-001
(9660014)
ABR-001 1 1 1 1

ABR-001
(9730000)

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM

TYPE
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 4x4
1
TIN-001 3 6 8 10 12 12 15 16 SECTION TABLE
2
GCI-001 1 1 1 1 1 1 1 1
1
4
7
2
5
8
3
6
9
Up to 100 m
C 0

TIN-001 5 5 TEL-001
MAN-010 1 1 1 1 1 1 1 1 (9600014) (9600001)
MLN-000 1 1 1 0,25 mm2 0,6 mm
MPS-003 1 1 mm2 1,1 mm
MPS-004 1 Up to 25 m
MPS-005 1 1 1 0,5 mm2 0,8 mm
MPD-003 1 1 2 3
2 2
MPD-004 1 1 2
1 2 3
4 5 6 4 5 6
7 8 9 7 8 9
C 0

5 5
C 0

TIN-001 TIN-001
MPD-005 1 1 (9600014) (9600014)
MPD-006 1 1
ALA-040 1 1 1 1 1 1 1 1 4+N
CEM-001 1 1 2 ALA-040 GCI-001
(9620001) (9650001)
CMO-004 1 1 1 2
2
CMO-006 1 1 2 1
ABR-001 1 1 1 1 1 1 1 230 V V MAN-010 230 V I2 I1

(9670001)
2
2
MPD-003

* Installation for 2 dwellings per floor and 6 floors (9660050)

ABR-001
(9730000)

ALCAD - 15
D I G I T A L A U D I O D O O

DIGITAL AUDIO DOOR ENTRY SYSTEM, WITH ELECTRONIC CALL, PRIVACY OF CONVERSATION SIM-
PLE AND MULTIPLE ACCESS POINTS

TELEPHONES
CODE TYPE DESCRIPTION PACK
9600007 TED-001 Digital phone with electronic call & privacy of
convesation 10/60
ENTRANCE PANEL MODULES WITH AUDIO UNIT, CARD HOLDER OR BLANK
CODE TYPE DESCRIPTION PACK
9600007
9670042 MAN-080 Entrance panel with digital audio unit 12
9670085 MMN-080 Entrance panel with digital audio unit. With card-holder 9
9670018 MTN-000 Entrance panel with card holder 12
9670021 MLN-000 Blank entrance panel 12
9670042 9670085 9730030 COL-000 Concentrator for 16 calls, for digital electronic door 18
entry systems
ENTRANCE PANEL
CODE TYPE DESCRIPTION PACK
9800000 PAK-01000 Entrance panel with digital audio unit, numerical display
9670018 9670021 and numerical keypad for calling the houses or flats 10
9800002 PTN-00000 Entrance panel with call code-house indicador
directory 10
9730014 AIB-000 Estate indentifying accessory 1
9730030 9730014
POWER SUPPLY UNITS
CODE TYPE DESCRIPTION PACK
9620001 ALA-040 25 VA power supply, electronic door entry system 15
9620014 ALC-070 DC power supply, digital audio & video door entry 9
system with keypad
CONCIERGE
CODE TYPE DESCRIPTION PACK
9680008 9680008 TCD-001 Digital telephone for concierge’s office with
electronic call and confidentiality feeature 10/60
9800000 9800012 PAK-03020 Entrance panel for concierge’s office with digital
audio unit, numeric display and numeruc keypad 7
9800012
9800016 9800016 PAK-02000 Panel with digital audio unit, numeric display and
9800017 numeric keypad for installations with concierge’s office 7
9620001 9800017 PAK-04000 Panel with digital audio unit, numeric display and numeric
keypad for external point of entry of concierge’s office 7
SAMPLE QUOTATION Entrance panel modules with push-buttons, accessories, cables, etc. see accessories page 32
SINGLE ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED BOX)
EXAMPLE WIRING DIAGRAM
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6
TYPE
TED-001 3 6 8 10 12 12 15 18 16 20 24 30 36 2 2 SECTION TABLE
MAN-080 1 1 1 1 1 1 1 1 1 1 1 1 1 Up to 100 m
MLN-000 1 1 1 1 1 1 2 2 TED-001 TED-001
MPS-003 1 (9600007) (9600007)
1 mm2 1,1 mm
MPS-004 1 Up to 50 m
MPS-005 1 1 mm 2
1,1 mm
MPS-006 1 2 2
Up to 25 m
MPD-003 1 0,5 mm2 0,8 mm
MPD-004 1 1 2 TED001 TED-001
MPD-005 1 1 2 3 (9600007) (9600007)

MPD-006 1 1 2 3 2
ALA-040 1 1 1 1 1 1 1 1 1 1 1 1 1
ALA-040
COL-000 1 1 1 1 1 1 1 2 1 2 2 2 3 (9620001)
CEM-001 1 1 1 1 1 1 2 2
CMO-004 1 1 1 2 2 230 V V MAN-080
CMO-006 1 1 2 2 2 2 3 3 2
(9670042)
MPD-003
ABR-001 1 1 1 1 1 1 1 1 1 1 1 1 1 2 (9660050)
+
COL-000
(9730030)

* Installation for 2 dwellings per floor and 6 floor


ALCAD - 16
ABR-001
(9730000)
O O R E N T R Y S Y S T E M

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM


2 ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED SECTION TABLE

*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6
TYPE
Up to 100 m

1 mm2 1,1 mm
TED-001 3 6 8 10 12 12 15 18 16 20 24 30 36 Up to 50 m
MAN-080 2 2 2 2 2 2 2 2 2 2 2 2 2 1 mm2 1,1 mm
MLN-000 2 2 2 2 2 2 4 4 Up to 25 m

MPS-003 2 0,5 mm2 0,8 mm


MPS-004 2
MPS-005 2
MPS-006 2 2 2

MPD-003 2
TED-001 TED-001
MPD-004 2 2 4 (9600007) (9600007)
MPD-005 2 2 4 6
MPD-006 2 2 4 6
ALA-040 2 2 2 2 2 2 2 2 2 2 2 2 2
COL-000 2 2 2 2 2 2 2 4 2 4 4 4 6 2 2

CEM-001 2 2 2 2 2 2 4 4
CMO-004 2 2 2 4 4 TED-001
(9600007)
TED-001
(9600007)
CMO-006 2 2 4 4 4 4 6 6
2
ABR-001 2 2 2 2 2 2 2 2 2 2 2 2 2
ALA-040 ALA-040
(9620001) (9620001)
MAN-080
(9670042)
MAN-080

* Installations for 2 dwellings per floor and 6 floors


230 V V 230 V V

(9670042)
2 2
2
2 2
MPD-004
(9660051)
+
COL-000 MPD-004
(9730030) (9660051)
+
ABR-001 COL-000 ABR-001
(9730000) (9730030) (9730000)

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM


1 ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED
Nº OF DWELLINGS 4x10 6x10 6x15 8x15 10x15 SECTION TABLE
2 2
TYPE Up to 100 m
TED-001 40 60 90 120 150
TED-001 TED-001
PAK-01000 1 1 1 1 1 (9600007) (9600007) 1 mm2 1,1 mm
PTN-00000 1 1 1 2 2 Up to 50 m

ALA-040 1 1 1 1 1 1 mm2 1,1 mm


Up to 25 m
ALC-070 1 1 1 1 1
2 2 0,5 mm2 0,8 mm
CEM-001 1 1 1 2 2
CMO-008 2 2 2 3 3
TED001 TED-001
ABR-001 1 1 1 1 1 (9600007) (9600007)

2
ALA-040 ALC-070
(9620001) (9620014)

230 V V 230V~ ++

2
2

2
1 2 3

4 5 6

7 8 9

C 0

PAK-01000 PTN-00000
ABR-001 (9800000) (9800002)
(9730000)

ALCAD - 17
D I G I TA L A U D I O D O O R E N T R Y S Y S T E M

SAMPLE QUOTATION

2 2 2 2 2 2

TED-001 TED-001 TED-001 TED-001 TED-001 TED-001


(9600007) (9600007) (9600007) (9600007) (9600007) (9600007)

2 2 2 2 2 2

TED001 TED-001 TED001 TED-001 TED001 TED-001


(9600007) (9600007) (9600007) (9600007) (9600007) (9600007)

2 2 2

ALA-040 ALA-040 ALA-040


(9620001) (9620001) (9620001)

230 V V MAN-080 230 V V MAN-080 230 V V MAN-080


(9670042) (9670042) (9670042)
2 2 2
MPD-003 MPD-003 MPD-003
(9660050) (9660050) (9660050)
2 + 2 + 2 +
COL-000 COL-000 COL-000
(9730030) (9730030) (9730030)
+ + +
AIB-000 AIB-000 AIB-000
(9730014) (9730014) (9730014)

ABR-001 ABR-001 2 ABR-001


(9730000) (9730000) (9730000)

2 2

ALA-040 ALC-070 ALC-070 ALA-040


(9620001) (9620014) (9620014) (9620001)

SECTION TABLE
230 V V 230V~ ++ 230V~ ++ 230 V V

Up to 100 m
2 2
1 mm2 1,1 mm 2 2
Up to 50 m 2
2
1 mm2 1,1 mm 1 2 3 1 2 3

Up to 25 m
4 5 6 4 5 6

7 8 9 7 8 9

C 0 C 0

2
0,5 mm 0,8 mm
PAK-04000 PTN-00000 PAK-03020
ABR-001 (9800017) (9800002) (9800012)
(9730000)

TCD-001
(9680008)

ALCAD - 18
VIDEO DOOR ENTRY SYSTEM

VIDEO DOOR ENTRY SYSTEM, MICROPROCESSOR-BASED 6+N AND COAXIAL CALL SYSTEM,
WITH ELECTRIC CALL, PRIVACY OF CONVERSATION, SIMPLE AND MULTIPLE ACCESS POINTS

MONITORS
CODE TYPE DESCRIPTION PACK

9630000 MVB-001 Analogue B/W video door entry monitor 10


9600003
9630002 SCM-010 Connection bracket for analogue monitor with connections 11

9630000 TELEPHONES
CODE TYPE DESCRIPTION PACK

9600003 TES-001 Telephone with electronic call and privacy of con-


9600012
versation 10/60
9670007 9600012 TES-002 Telephone with electronic call and privacy of con-
versation. 2 push-button 10/60

ENTRANCE PANEL MODULES WITH AUDIO UNIT, VIDEO UNIT, CARD


9630002
HOLDER OR BLANK
9670097 CODE TYPE DESCRIPTION PACK

9670007 MAN-041 Entrance panel with audio unit for video door entry system 12
9670098 MCN-041 Entrance panel with audio unit for video door entry system.
9670098 9670027 With blankmodule 9
9670097 MMN-041 Entrance panel with audio unit for video door entry system.
With card-holder 9
9670027 MVN-001 Entrance panel with B/W video unit 12
9670033 MVN-900 Compact panel with B/W video unit, coaxial 9
9670033 9670043
9670043 MDN-041 Entrance panel with MAN-041 and B/W video unit 9
9670071 MDT-041 Entrance panel with MAN-041 and B/W video unit. With card
holder 9
9670018 9670031 MVN-101 Entrance panel with B/W video unit, for main perime-
ter entrance 12
9670071 9670047 MDN-141 Entrance panel with MAN-041 and B/W video unit, for
main perimeter entrance 9
9640006 TCB-130 Video unit replacement accessory for main premiere entrance 18

9670086 9670018 MTN-000 Entrance panel with card holder 12


9670021 9670021 MLN-000 Blank entrance panel 12
9670086 MLT-000 Entrance panel with card holder and blank module 9

SPLITERS AND TAP-OFFS


9730031 9730032 CODE TYPE DESCRIPTION PACK

9730031 DIV-024 Video Tap-off for coaxial cable with screw terminal.
4 tap outputs and DC path 5/75
9730032 DIV-124 Amplified video splitter for coaxial cable with screw
terminal, 4 tap outputs 5/75
9670047 9640006

POWER SUPPLY UNITS


CODE TYPE DESCRIPTION PACK
9670031 9620001 ALA-040 25 VA power supply, electronic door entry system 15
9620011 ALM-040 25 VA power supply, electronic door entry system 15

Entrance panel modules with push-button, accessories, cables, etc. See accessories page 32
9620011 9620001 ALCAD - 19
VIDEO DOOR ENTRY SYSTEM

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM


SINGLE ACCESS
5 5
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED
DIV-024

*
(9730031)
SCM-010 COAX COAX SCM-010
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6 (9630002) (9630002)
+ +
TYPE MVB-001 2 2
MVB-001
(9630000) (9630000)
MVB-001 3 6 8 10 12 12 15 18 16 20 24 30 36
SCM-010 3 6 8 10 12 12 15 18 16 20 24 30 36
MDN-041 1 1 1 1 1
MVN-001 1 1 1 1 1 1 1 1 5 5
MAN-041 1 1 1 1 1 1 1 1 DIV-024
(9730031)
MLN-000 1 1 SCM-010 COAX COAX SCM-010
(9630002) (9630002)
MPS-003 1 +
2 2 +
MVB-001 MVB-001
MPS-004 1 (9630000) (9630000)
MPS-005 1
MPS-006 1
MPD-003 1
MPD-004 1 1 2
MPD-005 1 1 2 3 ALM-040 2 4+N COAX SECTION TABLE
(9620011)
MPD-006 1 1 2 3 Up to 100 m
ALM-040 1 1 1 1 1 1 1 1 1 1 1 1 1
ALA-040 1 1 1 1 1 1 1 1 1 1 1 1 1 230 V V
0,25 mm2 0,6 mm
DIV-024 3 3 4 5 6 4 5 6 4 5 6 10 12 2 1 mm2 1,1 mm
CEM-001 1 1 1 1 1 1 2 2 MDN-041 COAXIAL 75 Ω
(9670043)
CMO-004 2 2 1 Up to 50 m
CMO-006 1 1 1 2 2 2 2 3 3 1 mm2 1,1 mm
ALA-040 Up to 25 m
CMO-008 1 1 (9620001)
ABR-001 1 1 1 1 1 1 1 1 1 1 1 1 1 2 0,5 mm2 0,8 mm

230 V V

* Installation for 2 dwellings per floor and 6 floors


2
MPD-004
(9660051)
ABR-001
(9730000)

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM


2 ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED BOX)
5 5

TYPE
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6 SCM-010
(9630002)
+
COAX
DIV-024
(9730031)
COAX SCM-010
(9630002)
SECTION TABLE
Up to 100 m
2 2 +
MVB-001 MVB-001
MVB-001 3 6 8 10 12 12 15 18 16 20 24 30 36 (9630000) (9630000) 0,25 mm2 0,6 mm
1 mm2 1,1 mm
SCM-010 3 6 8 10 12 12 15 18 16 20 24 30 36
COAXIAL 75 Ω
MDN-041 2 2 2 2 2 Up to 50 m

MVN-001 2 2 2 2 2 2 2 2 5 5 1 mm2 1,1 mm


DIV-024 Up to 25 m
MAN-041 2 2 2 2 2 2 2 2 SCM-010 COAX (9730031)
COAX SCM-010
(9630002) 0,5 mm2 0,8 mm
MLN-000 2 2 +
MVB-001 2 2
(9630002)
+
MVB-001
MPS-003 2 (9630000) (9630000)

MPS-004 2
MPS-005 2
MPS-006 2
2
MPD-003 2 ALM-040
(9620011)
4+N COAX

MPD-004 2 2 4
MPD-005 2 2 4 6 230 V V

MPD-006 2 2 4 6 2 MDN-041
(9670043)
MDN-041
ALM-040 1 1 1 1 1 1 1 1 1 1 1 1 1 1
COAX
(9670043)

ALA-040 2 2 2 2 2 2 2 2 2 2 2 2 2 6+N

DIV-024 3 3 4 5 6 4 5 6 4 5 6 10 12
ALA-040 2 ALA-040 2
CEM-001 2 2 2 2 2 2 4 4 (9620001) (9620001)

CMO-004 4 4
CMO-006 2 2 2 4 4 4 4 6 6 230 V V MPD-004 230 V V MPD-004
(9660051) (9660051)
CMO-008 2 2 2 ABR-001 2 ABR-001
(9730000) (9730000)
ABR-001 2 2 2 2 2 2 2 2 2 2 2 2 2

* Installation for 2 dwellings per floor and 6 floors

ALCAD - 20
VIDEO DOOR ENTRY SYSTEM

EXAMPLE WIRING DIAGRAM DIV-024 DIV-024 DIV-024 SECTION TABLE


5 (9730031) 5 (9730031) 5 (9730031)
SCM-010 SCM-010 SCM-010 Up to 100 m
(9630002) (9630002) (9630002)
+ + +
MVB-001 2 MVB-001 2 MVB-001 2
(9630000) (9630000) (9630000) 0,25 mm2 0,6 mm
1 mm2 1,1 mm
COAXIAL 75 Ω
5 DIV-024 5 DIV-024 5 DIV-024 Up to 50 m
(9730031) SCM-010 (9730031) (9730031)
SCM-010
(9630002)
SCM-010 1 mm2 1,1 mm
(9630002) (9630002)
+ + + Up to 25 m
MVB-001 2 MVB-001 2 MVB-001 2
(9630000) (9630000)
(9630000) 0,5 mm2 0,8 mm

2 2 2
ALM-040
5 ALM-040
5 ALM-040
5
(9620011) (9620011) (9620011)
COAX COAX COAX

230 V V 230 V V 230 V V

1 MDN-041 1 MDN-041 1 MDN-041


(9670043) (9670043) (9670043)
ALA-040 ALA-040 ALA-040
(9620001) (9620001) (9620001)
2 2 2

230 V V 230 V V 230 V V

MPD-004 MPD-004 MPD-004


2 (9660051) 2 (9660051) 2 (9660051)

ABR-001 ABR-001 ABR-001


(9730000) (9730000) (9730000)
5
COAX
5 5
COAX COAX

ALA-040 MDN-141
(9620001) (9670047) MCN-041 x 2 + TCB-130 x 2
(9670098) (9640006)

230 V V
2

2 MPD-004 x 3
(9660051)

ABR-001
(9730000)

VIDEO DOOR ENTRY SYSTEM, MICROPROCESSOR-BASED 6+N AND TWISTED PAIR SYSTEM,
ELECTRONIC CALL, PRIVACY OF CONVERSATION, SIMPLE AND MULTIPLE ACCESS POINTS

MONITORS
CODE TYPE DESCRIPTION PACK

9630000 MVB-001 Analogue B/W video door entry monitor 10


9630000 9630003 SCM-020 Connection bracket for analogue monitor with
connections for twisted pair 11
TELEPHONES
CODE TYPE DESCRIPTION PACK

9600003 TES-001 Telephone with electronic call and privacy of


conversation 10/60
9600003 9600012 9600012 TES-002 Telephone with electronic call and privacy of
conversation 2 push-buttons 10/60
ENTRANCE PANEL MODULES WITH AUDIO UNIT, VIDEO UNIT, CARD
HOLDER OR BLANK
CODE TYPE DESCRIPTION PACK
9630003 9670007 9670007 MAN-041 Entrance panel with audio unit for video door entry
system 12
9670098 MCN-041 Entrance panel with audio unit for video door entry
system Blank module 9
9670097 MMN-041 Entrance panel with audio unit for video door entry
9670098 9670097 system. With card-holder 9
9670012 MVN-004 Entrance panel with B/W video unit for twisted
pair 12

9670012 ALCAD - 21
VIDEO DOOR ENTRY SYSTEM

9670013 MVN-901 Compact panel with B/W video unit for twisted pair
9
9670014 MDN-044 Entrance panel with MAN-041 and B/W video unit for
twisted pair 9
9670015 MDT-044 Entrance panel with MAN-041 and B/W video unit for
9670013 9670014
twisted pair. With card-holder 9
9670031 MVN-101 Entrance panel with B/W video unit, for main perime-
ter entrance 12
9670018 9670047 MDN-141 Entrance panel with MAN-041 and B7W video unit, for
main perimeter entrance 9
9670015 9640006 TCB-130 Accessory for main perimenter entrance 18
9730024 AAV-001 Accessory to adapt the video signal 18
9670018 MTN-000 Entrance panel with card holder 12
9670086
9670021 9670021 MLN-000 Blank entrance panel 12
9670086 MLT-000 Entrance panel with card holder and blank module 9

SPLITTERS AND TAP-OFFS


CODE TYPE DESCRIPTION PACK
9730015 9730016
9730015 DIV-034 Video Tap-Off for twisted pair, 4 tap output and
Dc path 18
9730016 DIV-134 Amplified video splitter for twisted pair, 4 outputs 18

9670047 9640006
POWER SUPPLY UNITS
CODE TYPE DESCRIPTION PACK
9620001 ALA-040 25 VA power supply, electronic door entry system 15
9670031 9730024 9620011 ALM-040 25 VA power supply unit, video door entry system 15
9620006 ALM-041 25 VA power supply unit for kit, video door entry system 15
Entrance panel modules with push-buttons, accessories, cables, etc. see accessories 32

9620011 9620001
SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM
SINGLE ACCESS
5 5
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED
PAR DIV-034 PAR
TRENZADO (9730015) TRENZADO

*
DIV-034

SCM-020 cod.9730015

SCM-020
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6 (9630003)
+
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1 (9630003)
+
2 2
TYPE MVB-001
(9630000)
MVB-001
(9630000)
MVB-001 3 6 8 10 12 12 15 18 16 20 24 30 36
SCM-020 3 6 8 10 12 12 15 18 16 20 24 30 36
MDN-044 1 1 1 1 1
5 5
MVN-004 1 1 1 1 1 1 1 1
PAR DIV-034 PAR
MAN-041 1 1 1 1 1 1 1 1 TRENZADO DIV-034
(9730015) TRENZADO
SCM-020 cod.9730015

SCM-020
MLN-000 1 1 (9630003)
+
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1 (9630003)
2 2 +
MPS-003 1 MVB-001
(9630000)
MVB-001
(9630000)
MPS-004 1
MPS-005 1
MPS-006 1
MPD-003 1
MPD-004 1 1 2 2 PAR SECTION TABLE
ALM-040 4+N
(9620011) TRENZADO To 100 m
MPD-005 1 1 2 3
MPD-006 1 1 2 3 0,25 mm2 0,6 mm
ALM-040 1 1 1 1 1 1 1 1 1 1 1 1 1 230 V V
1 mm2 1,1 mm
ALA-040 1 1 1 1 1 1 1 1 1 1 1 1 1 2 0,25 mm 2 0,6 mm
DIV-034 3 3 4 5 6 4 5 6 4 5 6 10 12 MDN-044
(9670014)
To 25 m
1
CEM-001 1 1 1 1 1 1 2 2 1 mm2 1,1 mm
CMO-004 2 2 ALA-040
0,5 mm2 0,8 mm
(9620001)
CMO-006 1 1 1 2 2 2 2 3 3 2
CMO-008 1 1
ABR-001 1 1 1 1 1 1 1 1 1 1 1 1 1 230 V V

MPD-004
2 (9660051)

* Installation for 2 dwellings per floor and 6 floors


ALCAD - 22
ABR-001
(9730000)
VIDEO DOOR ENTRY SYSTEM

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM


2 ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED BOX
5 5

TYPE
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6 SCM-020
(9630003)
+
PAR
TRENZADO DIV-034
cod.9730015

T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1


DIV-034 PAR
(9730015) TRENZADO
SCM-020
(9630003)
SECTION TABLE
Up to 100 m

2 2 +
MVB-001
MVB-001 3 6 8 10 12 12 15 18 16 20 24 30 36 (9630000)
MVB-001
(9630000)
0,25 mm2 0,6 mm
1 mm2 1,1 mm
SCM-020 3 6 8 10 12 12 15 18 16 20 24 30 36 0,25 mm 2 0,6 mm
MDN-044 2 2 2 2 2 Up to 25 m

MVN-004 2 2 2 2 2 2 2 2 5 5 1 mm2 1,1 mm


PAR DIV-034 PAR 0,5 mm2 0,8 mm
MAN-041 2 2 2 2 2 2 2 2 SCM-020 TRENZADO DIV-034
cod.9730015
(9730015) TRENZADO
SCM-020
(9630003)
MLN-000 2 2 +
2
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

2
(9630003)
+
MVB-001 MVB-001
MPS-003 2 (9630000) (9630000)

MPS-004 2
MPS-005 2
MPS-006 2
2
MPD-003 2 ALM-040
(9620011)
4+N PAR
TRENZADO
MPD-004 2 2 4
MPD-005 2 2 4 6 230 V V

MPD-006 2 1 4 6 2 MDN-044
(9670014)
PAR
MDN-044
TRENZADO
ALM-040 2 2 2 2 2 2 2 2 2 2 2 2 2 1
(9670014)

ALA-040 2 2 2 2 2 2 2 2 2 2 2 2 2 6+N
ALA-040
DIV-034 3 3 4 5 6 4 5 6 4 5 6 10 12 (9620001)
ALA-040 2
2 (9620001)
CEM-001 2 2 2 2 2 2 4 4
CMO-004 4 4 230 V V

CMO-006 2 2 2 4 4 4 4 6 6 2
MPD-004
230 V V MPD-004
(9660051)
(9660051)
CMO-008 2 2 ABR-001
2 ABR-001
(9730000)
(9730000)
ABR-001 2 2 2 2 2 2 2 2 2 2 2 2 2

* Installation for 2 dwellings per floor and 6 floors


EXAMPLE WIRING DIAGRAM

5 DIV-034 5 DIV-034 5 DIV-034


SCM-020 (9730015) SCM-020 (9730015) SCM-020 (9730015)
(9630003)
DIV-034
cod.9730015
(9630003)
DIV-034
cod.9730015
(9630003)
DIV-034
cod.9730015 SECTION TABLE
+ + +
Up to 100 m
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

MVB-001 2 MVB-001 2 MVB-001 2


(9630000) (9630000) (9630000)

1 mm2 1,1 mm
COAXIAL 75 Ω
5 DIV-034 5 DIV-034 5 DIV-034
(9730015) (9730015) (9730015) Up to 25 m
SCM-020 SCM-020 SCM-020
1 mm2 1,1 mm
DIV-034 DIV-034 DIV-034
cod.9730015 cod.9730015 cod.9730015

(9630003) (9630003) (9630003)


+ + +
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

MVB-001 2 MVB-001 2 MVB-001 2 0,5 mm2 0,8 mm


(9630000) (9630000) (9630000)

2 4 2 4 2 4
ALM-040 + ALM-040 + ALM-040 +
(9620011) N (9620011) N (9620011) N
PAR PAR PAR
TRENZADO TRENZADO TRENZADO
230 V V 230 V V 230 V V

MDN-044 MDN-044 MDN-044


1 (9670014) 1 (9670014) 1 (9670014)
ALA-040 ALA-040 ALA-040
(9620001) 2 (9620001) 2 (9620001) 2

230 V V
MPD-004 230 V V
MPD-004 230 V V
MPD-004
(9660051) (9660051) (9660051)
2 2 2

ABR-001 ABR-001 ABR-001


PAR (9730000) PAR (9730000) PAR (9730000)
TRENZADO 6+N TRENZADO TRENZADO
6+N 6+N

MDN-141
(9670047)
+ TCB-130 x 2
ALA-040 (9640006)
(9620001) AAV-001 MCN-041 x 2 +
(9730024) (9670098) +
AAV-001 x 2
(9730024)
230 V V
2

2 MPD-004 x 3
(9670051)

ABR-001
(9730000)

ALCAD - 23
D I G I T A L V I D E O D O O

DIGITAL VIDEO DOOR ENTRY SYSTEM, MICROPROCESSOR-BASED, ELECTRONIC CALL, PRIVACY


OF CONVESATION, SIMPLE AND MULTIPLE ACCESS POINTS
MONITORS
CODE TYPE DESCRIPTION PACK
9630006 MVB-002 Analogue B/W video monitor 10
9630004 SCM-030 Connection bracket for digital monitor with connections 11
9600007 9630006
TELEPHONES
CODE TYPE DESCRIPTION PACK
9600007 TED-001 Digital phone with electronic call & privacy of conversation 10/60

ENTRANCE PANEL MODULES WITH AUDIO UNIT, VIDEO UNIT, CARD


9670042
HOLDER OR BLANK
CODE TYPE DESCRIPTION PACK
9630004 9670042 MAN-080 Entrance panel with digital audio unit 12
9670099 MCN-080 Entrance panel with digital audio unit. With Blank module 9
9670027
9670031 9670085 MMN-080 Entrance panel with digital audio unit. With card-holder 9
9670027 MVN-001 Entrance panel with B/W video unit 12
9670085 9670033 MVN-900 Entrance panel, individual, with B/W video unit 9
9670057 MDN-081 Entrance panel with MAN-080 and B/W video unit 9
9670029 MDT-081 Entrance panel with MAN-080 and B/W video unit. with card holder 9
9670099 9670031 MVN-101 Entrance panel with B/W video unit, for main perimeter entrance 12
9670061 MDN-181 Entrance panel with MAN-080 and B/W video unit, for main perimeter entrance 9
9670057
9670061 9640006 TCB-130 Video unit replacement accessory for main perimeter entrance 18
9670018 MTN-000 Entrance panel with card holder 12
9670021 MLN-000 Blank entrance panel 12
9670033 9670086 MLT-000 Entrance panel with card holder and blank module 9
9730030 COL-000 Concentrator for 16 calls, for digital electronic door system 18

9670029 ENTRANCE PANEL MODULES WITH AUDIO UNIT


CODE TYPE DESCRIPTION PACK
9670021
9800001 PDK-01100 Entrance panel with digital audio unit, B/W video unit, numerical
display and numerical keypad for calling the houses and flats 10
9670018 9800002 PTN-00000 Entrance panle with call code-house indicador
directory 10
9640006 9730014 AIB-000 Estate indentifying accessory 1

SPLITTERS AND TAP-OFF


CODE TYPE DESCRIPTION PACK
9730030 9670086 9730031 DIV-024 Video Tap-off for coaxial cable with screw terminal.
4 tap outputs and DC path 5/75
9730032 DIV-124 Amplified video splitter for coaxial cable with screw
terminal. 4 tap outputs 5/75
POWER SUPPLY UNITS
CODE TYPE DESCRIPTION PACK
9730031 9730032
9620001 ALA-040 25 VA power supply, electronic door entry system 15
9620011 ALM-040 25 VA power supply unit, video door entry system 15
9620001 9620006 ALM-041 25 VA power supply unit for Kit, video door entry system 9
9620011
CONCIERGE
CODE TYPE DESCRIPTION PACK
9680008 TCD-001 Digital telephone for concierge’s office with electro-
nic call and confidentiality feature 10/60
9800012 PAK-03020 Entrance panel for concierge’s office with digital
audio unit, numeric display and numeric keypad 7
9800016 PAK-02000 Panel with digital audio unit, numeric display and nume-
ric keypad for installations with concierge’s office 7
9800012 9800001 9800002 9800017 PAK-04000 Desktop support for monitor (Does not include the connection
9800016 bracket for monitor)
9800017 7
ALCAD - 24 Entrance panel modules with push-buttons, accessories, cables, etc. see accessories page 32
O O R E N T R Y S Y S T E M

SAMPLE QUOTATION EXAMPLE WIRING DIAGRAM


SINGLE ACCESS
2 2
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED
DIV-024

*
(9730031)
SCM-030 COAX COAX SCM-030
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6 (9630004) (9630004)
+ +
TYPE MVB-002 2 2
MVB-002
(9630006) (9630006)
MVB-002 3 6 8 10 12 12 15 18 16 20 24 30 36
SCM-030 3 6 8 10 12 12 15 18 16 20 24 30 36
MDN-081 1 1 1 1 1
MVN-001 1 1 1 1 1 1 1 1 2 2
MAN-080 1 1 1 1 1 1 1 1 DIV-024
(9730031)
MLN-000 1 1 SCM-030 COAX COAX SCM-030
(9630004) (9630004)
MPS-003 1 1 1 +
2 2 +
MVB-002 MVB-002
MPS-004 1 (9630006) (9630006)
MPS-005 1
MPS-006 1
MPD-003 1
MPD-004 1 1 2
MPD-005 1 1 2 3 2 SECTION TABLE
ALM-040 2 COAX
(9620011) Up to 100 m
MPD-006 1 1 2 3
ALM-040 1 1 1 1 1 1 1 1 1 1 1 1 1
1 mm2 1,1 mm
ALA-040 1 1 1 1 1 1 1 1 1 1 1 1 1
COAXIAL 75 Ω
230 V V

COL-000 1 1 1 1 1 1 1 2 2 2 2 2 3 2 Up to 25 m
DIV-024 3 3 4 5 6 4 5 6 4 5 6 10 12 MDN-081
(9670057) 1 mm2 1,1 mm
CEM-001 1 1 1 1 1 1 2 2 1
0,5 mm2 0,8 mm
CMO-004 2 2
ALA-040
CMO-006 1 1 1 2 2 2 2 3 3 (9620001)
CMO-008 1 1 2

ABR-001 1 1 1 1 1 1 1 1 1 1 1 1 1
230 V V

MPD-004
2 (9660051)
+

* Installation for 2 dwellings per floor and 6 floors COL-000


(9730030)
ABR-001
(9730000)

2 ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED
2 2
DIV-024
Nº OF DWELLINGS 4x10 6x10 6x15 8x15 10x15 SCM-030 COAX (9730031)
COAX SCM-030
(9630004) (9630004)
TYPE +
2 2
+
MVB-002 MVB-002
MVB-002 40 60 90 120 150 (9630006) (9630006)
SCM-030 40 60 90 120 150
PDK-01100 1 1 1 1 1
PTN-00000 1 1 1 2 2
ALA-040 2 2
1 1 1 1 1
ALC-070 1 1 1 1 1 DIV-024
(9730031)
SCM-030 COAX COAX SCM-030
DIV-024 10 20 30 30 45 (9630004) (9630004)
+ +
CEM-001 1 1 1 2 2 MVB-002 2 2 MVB-002
(9630006) (9630006)
CMO-008 2 2 2 3 3
ABR-001 1 1 1 1 1

SECTION TABLE
2 2 COAX
ALA-040 ALC-070 Up to 100 m
(9620001) (9620014)

1 mm2 1,1 mm
COAXIAL 75 Ω
230 V V 230V~ ++
Up to 25 m
1 mm2 1,1 mm
2 0,5 mm2 0,8 mm
2

2 1

4
2

5
3

7 8 9

C 0

PDK-01100 PTN-00000
ABR-001 (9800001) (9800002)
(9730000)
ALCAD - 25
D I G I T A L V I D E O D O

EXAMPLE WIRING DIAGRAM

DIV-024 DIV-024 DIV-024


2 (9730031) 2 (9730031) 2 (9730031)
SCM-030 SCM-030 SCM-030
(9630004) (9630004) (9630004)
+ + +
MVB-002 2 MVB-002 2 MVB-002 2
(9630006) (9630006) (9630006)

2 DIV-024 2 DIV-024 2 DIV-024


(9730031) SCM-030 (9730031) (9730031)
SCM-030 SCM-030
(9630004) (9630004) (9630004)
+ + +
MVB-002 2 MVB-002 2 MVB-002 2
(9630006) (9630006) (9630006)

2 2 2
ALM-040
2 ALM-040
2 ALM-040
2
(9620011) (9620011) (9620011)
COAX COAX COAX

230 V V 230 V V 230 V V

1 MDN-081 1 MDN-081 1 MDN-081


(9670057) (9670057) (9670057)
ALA-040 ALA-040 ALA-040
(9620001) (9620001) (9620001)
2 2 2
MPD-004 MPD-004 MPD-004
230 V V (9660051) 230 V V (9660051) 230 V V (9660051)
+ + +
2 COL-000 2 COL-000 2 COL-000
(9730030) (9730030) (9730030)
+ + +
2 AIB-000 2 AIB-000 2 AIB-000
(9730014) ABR-001 (9730014) ABR-001 (9730014) ABR-001
(9730000) (9730000) (9730000)

ALA-040 ALC-070 ALC-070 ALA-040


(9620001) (9620014) (9620014) (9620001)

SECTION TABLE 2
230 V V 230V~ ++ 230V~ ++ 230 V V

Up to 100 m
2 2
1 mm2 1,1 mm 2 2
COAXIAL 75 Ω 2
2
Up to 25 m
1 2 3 1 2 3

1 mm2 1,1 mm 4

7
5

8
6

9
4

7
5

8
6

C 0 C 0

0,5 mm2 0,8 mm


PAK-04000 PTN-00000 PAK-03020
ABR-001 (9800017) (9800002) (9800012)
(9730000)

TCD-001
(9680008)

ALCAD - 26
O O R E N T R Y S Y S T E M

DIGITAL VIDEO DOOR ENTRY SYSTEM, MICROPROCESSOR-BASED, TWISTED PAIR SYSTEM,


ELECTRONIC CALL, PRIVACY OF CONVERSATION, SIMPLE AND MULTIPLE ACCESS POINTS
MONITORS
CODE TYPE DESCRIPTION PACK
9630006 MVB-002 Digital B/W video monitor 10
9630005 SCM-040 Connection bracket for digital monitor with connections
11
for twisted pair
9630004
TELEPHONES
CODE TYPE DESCRIPTION PACK
9630006
9600007 TED-001 Digital phone with electric call & privacy of con-
versation 10/60

ENTRANCE PANEL MODULES WITH AUDIO UNIT, VIDEO UNIT, CARD


9600007 HOLDER OR BLANK
9670042
CODE TYPE DESCRIPTION PACK
9670042 MAN-080 Entrance panel with digital audio unit 12
9670099 MCN-080 Entrance panel with digital audio unit. With Blank
module 9
9670012 9670085
9670031 9670085 MMN-080 Entrance panel with digital audio unit. With card-holder
9
9670012 MVN-004 Entrance panel with B/W video unit for twisted pair
12
9670013 MVN-901 Compact panel with B/W video unit for twisted pair
9
9670099 9670017 9670016 MDN-084 Entrance panel with MAN-080 and B/W video unit for
twisted pair 9
9670017 MDT-084 Entrance panel with MAN-080 and B/W video unit for
twisted pair, with card holder 9
9670031 MVN-101 Entrance panel with B/W camera, for main perimeter entrance 12
9640006 9670061 MDN-181 Panel A/V GRF-008 B/W main entrance coax 9
9670016
9670061 9640006 TCB-130 Camera replacement accessory for main perimeter entrance 18
9730024 AAV-001 Accessory to adapt the video signal 18
9670021 9670018 MTN-000 Entrance panel with card holder 12
9670021 MLN-000 Blank entrance panel 12
9670018 9670086 MLT-000 Enrance panel with card holder and blank module 9
9730030 COL-000 Concentrator for 16 calls, for digital electronic door entry system 18
9730030
SPLITTERS AND TAP-OFFS
CODE TYPE DESCRIPTION PACK
9730015 DIV-034 Video Tap-off for twisted pair, 4 tap outputs and
9670086 DC path 18
9730016 DIV-134 Amplified video splitter for twisted pair, 4
outputs 18

ENTRANCE PANEL MODULES


CODE TYPE DESCRIPTION PACK

9800011 PDK-01400 Entrance panel with digital audio unit, B/W video unit for twisted
9800011 9800002 9670013 pair, numerical display and keypad for calling the houses or flats 10
9800002 PTN-00000 Entrance panel with call code-house indicator
directory 10
9730014 AIB-000 Estate indentifying accessory 1
9730014
POWER SUPPLY UNITS
CODE TYPE DESCRIPTION PACK

9620001 ALA-040 25 VA power supply units, electronic door entry system 15


9730031 9730032 9620011 ALM-040 25 VA power supply unit, video door entry system 15
9620014 ALC-070 DC power supply, digital audio & video door entry 9
system with keypad
9620006 ALM-041 25 VA power supply unit for kit, video door entry system 15
9620014 9620001 Entrance panel modules with push-buttons, accessories, cables, etc. See accessories page 32
9620011
ALCAD - 27
D I G I T A L V I D E O D O

SAMPLE QUTATION EXAMPLE WIRING DIAGRAM


SINGLE ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED BOX)

TYPE
*
Nº OF DWELLINGS 1x3 2x3 2x4 2x5 2x6 3x4 3x5 3x6 4x4 4x5 4x6 6x5 6x6
2
PAR DIV-034
2
PAR
TRENZADO DIV-034 (9730015) TRENZADO
SCM-040 cod.9730015

SCM-040
MVB-002 3 6 8 10 12 12 15 18 16 20 24 30 36 (9630005) T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1 (9630005)
+ +
SCM-040 3 6 8 10 12 12 15 18 16 20 24 30 36 MVB-002 2 2 MVB-002
(9630006) (9630006)
MDN-084 1 1 1 1 1
MVN-004 1 1 1 1 1 1 1 1
MAN-080 1 1 1 1 1 1 1 1
MLN-000 1 1 2 2
MPS-003 1 PAR DIV-034 PAR
MPS-004 1 SCM-040 TRENZADO DIV-034
cod.9730015 (9730015) TRENZADO
SCM-040
(9630005) (9630005)
MPS-005 1 +
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

+
MVB-002 2 2 MVB-002
MPS-006 1 (9630006) (9630006)
MPD-003 1
MPD-004 1 1 2
MPD-005 1 1 2 3
MPD-006 1 1 2 3
ALM-040 1 1 1 1 1 1 1 1 1 1 1 1 1 2 PAR SECTION TABLE
ALM-040 2
(9620011) TRENZADO Up to 100 m
ALA-040 1 1 1 1 1 1 1 1 1 1 1 1 1
COL-000 1 1 1 1 1 1 1 2 1 2 2 2 3
1 mm2 1,1 mm
DIV-034 3 3 4 5 6 4 5 6 4 5 6 10 12
230 V V
0,25 mm 0,6 mm
CEM-001 1 1 1 1 1 1 2 2 2 Up to 25 m
CMO-004 2 2 MDN-084 1 mm2 1,1 mm
CMO-006 1 1 1 2 2 2 2 3 3 1 (9670016)
0,5 mm2 0,8 mm
CMO-008 1 1
ALA-040
ABR-001 1 1 1 1 1 1 1 1 1 1 1 1 1 (9620001)
2

230 V V

* Installation for 2 dwellings per floor and 6 floors 2 MPD-004


(9660051)
+
COL-000 ABR-001
(9730030) (9730000)

2 ACCESS
(IT INCLUDES STANDARD ELECTRIC LOCK AND FLUSH MOUNTED
2 2
DIV-034
Nº OF DWELLINGS 4x10 6x10 6x15 8x15 10x15 SCM-040
TRENZADO DIV-034
cod.9730015
(9730015)
TRENZADO SCM-040
TYPE (9630005)
+
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1
(9630005)
+
MVB-002 2 2 MVB-002
MVB-002 40 60 90 120 150 (9630006) (9630006)
SCM-040 40 60 90 120 150
PDK-01400 1 1 1 1 1
PTN-00000 1 1 1 2 2
2 2
ALA-040 1 1 1 1 1
DIV-034
ALC-070 1 1 1 1 1 TRENZADO DIV-034
cod.9730015
(9730015)
TRENZADO
SCM-040 SCM-040
DIV-034 10 20 30 30 45 (9630005)
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

(9630005)
+ 2 2 +
CEM-001 1 1 1 2 2 MVB-002 MVB-002
(9630006) (9630006)
CMO-008 2 2 2 3 3
ABR-001 1 1 1 1 1

2 2 TRENZADO SECTION TABLE


ALA-040 ALC-070
(9620001) (9620014) Up to 100 m

1 mm2 1,1 mm
230 V V 230V~ ++
0,25 mm 0,6 mm
Up to 25 m

2 1 mm2 1,1 mm
0,5 mm2 0,8 mm
2

2 1

4
2

5
3

7 8 9

C 0

PDK-01400 PTN-00000
ABR-001 (9800011) (9800002)
(9730000)

ALCAD - 28
O O R E N T R Y S Y S T E M

EXAMPLE WIRING DIAGRAM

2 DIV-034 2 DIV-034 2 DIV-034


(9730015) (9730015) (9730015)
SCM-040 DIV-034
SCM-040 DIV-034
SCM-040 DIV-034

(9630005) (9630005) (9630005)


cod.9730015 cod.9730015 cod.9730015

+ T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

+ T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

+ T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

MVB-002 2 MVB-002 2 MVB-002 2


(9630006) (9630006) (9630006)

2 DIV-034 2 DIV-034 2 DIV-034


(9730015) (9730015) (9730015)
SCM-040 DIV-034
cod.9730015 SCM-040 DIV-034
cod.9730015 SCM-040 DIV-034
cod.9730015

(9630005) T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1


(9630005) T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1
(9630005) T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

+ + +
MVB-002 2 MVB-002 2 MVB-002 2
(9630006) (9630006) (9630006)

2 2 2 2 2 2
ALM-040 ALM-040 ALM-040
(9620011) (9620011) (9620011)
PAR PAR PAR
TRENZADO TRENZADO TRENZADO
230 V V 230 V V 230 V V

MDN-084 MDN-084 MDN-084


1 (9670016) 1 (9670016) 1 (9670016)
ALA-040 ALA-040 ALA-040
(9620001) 2 (9620001) 2 (9620001) 2

MPD-004 MPD-004 MPD-004


(9660051) (9660051) (9660051)
+ + +
230 V V 230 V V 230 V V

COL-000 COL-000 COL-000


2 (9730030) 2 (9730030) 2 (9730030)
+ + +
AIB-000 AIB-000 AIB-000
(9730014) ABR-001 (9730014) ABR-001 (9730014) ABR-001
(9730000) (9730000) (9730000)
2 2 2
PAR PAR PAR
TRENZADO TRENZADO TRENZADO

DIV-134
cod.9730016

ALA-040 ALC-070 12 V

V
15 V
+ T1+ T1 T1+ T1 T1+ T1 T1+ T1 T1+ T1

(9620001) (9620014)
DIV-134
(9730016)
PAR
230 V V 230V~ ++ TRENZADO SECTION TABLE
2 2 Up to 100 m
2
1 mm2 1,1 mm
2
0,25 mm 0,6 mm
Up to 25 m

2 1 2 3
1 mm2 1,1 mm
0,5 mm2 0,8 mm
4 5 6

7 8 9

C 0

PDK-01400 PTN-00000
ABR-001 (9800011) (9800002)
(9730000)

ALCAD - 29
T V D O O R E N T R Y S Y S T E M

This is a system designed to complement existing electronic door entry systems in buildings and flats.
The TV Door Entry System, tapping into the distribution of the collective signal of the building and
using the video cameras installed at the different points of entry, allows you to visualise the person
who is calling clearly and distinctly by simply changing your television channel. Without having to
move from your television set, you will know who is at your door and whether or not the call is worth
getting up to answer.

MODULATORS
CODE TYPE DESCRIPTION PACK
9650007 MDA-300 Multistandard BIII modulator with DC output to
supply a video unit with external power supply 12
9650009 MDA-400 Multistandard UHF modulator with DC output
9650007 supply a video unit with external power supply 12
9650009

ENTRANCE PANLE MODULES WITH AUDIO UNIT, VIDEO UNIT, CARD


HOLDER OR BLANK
CODE TYPE DESCRIPTION PACK

9670100 MVN-902 Compact panel with B/W video unit for coaxial
cable. External power supply 9
9670101 MVN-201 Entrance panel with B/W video unit for coaxial
cable. External power supply 12
9670102 MDN-241 Entrance panel with MAN-041 and B/W video
9670100 9670101 unit for coaxial cable. External power supply 9
9670103 MDT-241 Entrance panel with MAN-41 and B/W video unit for
coaxial cable. External power supply. With card holder 9
9670104 MDN-281 Entrance panel with MAN-080 and B/W video unit for
coaxil cable. Exetrnal power supply 9
9670105 MDT-281 Entrance panel with MAN-080 and B/W video unit for
coaxil cable. Exetrnal power supply. With card holder 9
9670102 9670103
9670104 9670105 EXAMPLE WIRING DIAGRAM

SECTION TABLE
Up to 100 m

0,25 mm2 0,6 mm


CABECERA TV
1 mm2 1,1 mm
COAXIAL 75 Ω
Up to 50 m
1 mm2 1,1 mm
5 5
Up to 25 m

0,5 mm2 0,8 mm


TES-001 TES-001
(9600003) TV TV (9600003)

5 5

TES-001 TES-001
(9600003) TV TV (9600003)

4+N

COAX

MDN-241 COAX
(9670102)

2 MDA-300 MDA-400
ALA-040 9650007 9650009
(9620001)
2

230 V V

MPD-004
2 (9660051)
ABR-001
ALCAD - 30 (9730000)
M V I D E O D O O R P C

ALCAD announces the launch of a new system of entry control. The


system, based on an interface between entrance panel and computer,
makes it possible for users to receive and manage calls made from the
entrance panel via their computer, enabling them to see the caller on
their computer screen without having to have a video door entry
monitor.
The system allows users to answer calls from their computer, open the
door manually or automatically, and record the last 500 call received,
memorizing the caller’s image as well as the time of the call and
whether it was answered or not.
Highly recommended for businesses, hotel receptions, etc. where it is
often essential to keep a record of people entering the area.

INTERFACE PC
CODE TIPE DESCRIPTION PACK
9730017 ACO-000 Accessory allowing to drive the analogue video door entry,
6+N and coaxial system, from a PC 10
9720030 KOS-08201 Kit to drive the analogue video door entry from a PC. 1
single push-button, 6+N and coaxial call system 10

EXAMPLE WIRING DIAGRAM


ACO-000
(9730017)

9730017 VIDEO
OUT
MIC
IN
MIC
OUT
AUDIO
OUT
USB
SECTION TABLE
To 100 m
ACO-000
cod. 9730017 Made in Spain

0,25 mm2 0,6 mm


A
SW1

1 mm2 1,1 mm
A
SW2

B 15V P1 P2
M V1 1 2 3 4 5 24 25 26 27

COAXIAL 75 Ω
PC To 50 m
4+N COAX 1 mm2 1,1 mm
To 25 m

0,5 mm2 0,8 mm


230 V V

ABR-001
(9730000)

A C C E S S C O N T R O L S Y S T E M

ACCESS CONTROL SYSTEMS


9660016 MKD-900 Configurable push-button entrance panel 1-4
storeys and keypad for access control 9

9800006 PNK-00000 Entrance panel with keypad for access control 7

9800006

ALCAD - 31
A C C E S S

ENTRANCE PANEL MODULES WITH PUSH-BUTTONS


•Attractively designed push-button entrance panels, compatible with all the entrance
panel modules that have an audio unit, with card-holder or blank.
•Made with extruded aluminium profiles.
•The module tilts for easy connection.
9660014 •Several entrance panels can be combined side by side.

9660015 ENTRANCE PANEL MODULES WITH SINGLE PUSH-BUTTONS


CODE TYPE DESCRIPTION PACK
9660014 MPS-001 Entrance panel with 1 single
9660000
push-button 12
9660001
9660015 MPS-002 Entrance panel with 2 single
push-button 12

9660002 9660000 MPS-003 Entrance panel with 3 single


push-button 9
9660003

9660001 MPS-004 Entrance panel with 4 single


push-button 9

9660004 9660002 MPS-005 Entrance panel with 5 single


push-button 9
9660005

9660003 MPS-006 Entrance panel with 6 single


push-button 9

9660004 MPS-007 Entrance panel with 7 single


9660006 push-button 9

9660007
9660005 MPS-008 Entrance panel with 8 single
push-button 9

9660006 MPS-009 Entrance panel with 9 single


push-button 13

9660008
9660007 MPS-010 Entrance panel with 10 single
push-button 13
9660009

9660008 MPS-011 Entrance panel with 11 single


push-button 13

9660009 MPS-012 Entrance panel with 12 single


push-button 13

9660010 MPS-013 Entrance panel with 13 single


9660010 push-button 13
9660011

9660011 MPS-014 Entrance panel with 14 single


push-button 13

9660012 MPS-015 Entrance panel with 15 single


push-button 10

9660013 MPS-016 Entrance panel with 16 single


9660012 10
push-button
9660013
ALCAD - 32
S O R I E S

ENTRANCE PANELS WITH DOUBLE PUSH-BUTTONS


CODE TYPE DESCRIPTION PACK
9660048 MPD-001 Entrance panel with 1 double
9660048 push-button 12
9660049
9660049 MPD-002 Entrance panel with 2 double
push-button 12

9660050 9660050 MPD-003 Entrance panel with 3 double


9660051 push-button 9

9660051 MPD-004 Entrance panel with 4 double


push-button 9
9660052
9660053 9660052 MPD-005 Entrance panel with 5 double
push-button 9

9660053 MPD-006 Entrance panel with 6 double


push-button 9
9660054

9660055 9660054 MPD-007 Entrance panel with 7 double


push-button 9

9660055 MPD-008 Entrance panel with 8 double


push-button 9

9660056
9660056 MPD-009 Entrance panel with 9 double
push-button 13
9660057

9660057 MPD-010 Entrance panel with 10 double


push-button 13

9660058 MPD-011 Entrance panel with 11 double


push-button 13

9660058 9660059 MPD-012 Entrance panel with 12 double


9660059
push-button 13

9660060 MPD-013 Entrance panel with 13 double


push-button 13

9660061 MPD-014 Entrance panel with 14 double


push-button 13

9660062 MPD-015 Entrance panel with 15 double


9660060
9660061 push-button 10

9660063 MPD-016 Entrance panel with 16 double


push-button 10

9660064 MPD-900 Configurable push-button entrance


panel 1-8 rows 9

9660065 MPD-901 Configurable push-button entrance


9660062 panel 9-16 rows 10
9660063
ALCAD - 33
A C C E S S

ACCESSORIES FOR ENTRANCE PANELS


FLUSH-MOUNTED BOXES
•The appropriate box should be selected acording to the number of rows of the push-button antrance
and of the entrace panel module with audio unit, card-holder or blank.

275 Módulos placa de calle


Configuración de Caja de empotrar Caja de superficie Visera
placa de calle necesaria necesaria necesaria
Superior Inferior
131
ARRIBA
UP
HAUT

9740008
9740005
Módulo Simple Modelo MPS-004 CMO-004
CSU-012 VIS-012
ARRIBA
UP
HAUT

179
371 Módulo Doble Modelo MPS-004
CMO-006 CSU-013 VIS-013
ARRIBA

9740006
UP
HAUT

9740010 Módulo Triple Modelo MPS-004


CMO-008 CSU-014 VIS-014
227 ARRIBA
UP
HAUT

Modelo MVN-900 CMO-002 CSU-011 VIS-011


9740007

CODE TYPE DESCRIPTION PACK


467
9740005 CMO-002 Flush-mounted box for 1 or 2
rows 16
323
9740006 CMO-004 Flush-mounted box for 3 or 4
rows 12
9740012
9740009
9740007 CMO-006 Flush-mounted box for 5 or 6
rows 16

9740008 CMO-008 Flush-mounted box for 7 or 8


rows 15

419 9740009 CMO-010 Flush-mounted box for 9 or 10


515
rows 12

9740010 CMO-012 Flush-mounted box for 11 or 12


rows 12
9740011
9740011 CMO-014 Flush-mounted box for 13 or 14
9740015 rows 12

9740012 CMO-016 Flush-mounted box for 15 or 16


rows 12
9740004

9740015 CMO-018 Flush-mounted box for 17 or 18


rows 20

9740004 CEM-001 Set of separators for


flush-mounted box (2 items) 50
ALCAD - 34
S O R I E S

SINGLE SURFACE BOXES


•The appropiate box should be selected according to the number of rows of the push-button entrance
panel module and of the entrance panel module with audio unit, video unit, card-holder or blank.

CODE TYPE DESCRIPTION PACK

9740048 CSU-011 Single surface box for 1 or 2 rows 16

9740049 CSU-012 Single surface box for 2 or 4 rows 12


9740049
9740050 CSU-013 Single surface box for 5 or 6 rows 6

9740051 CSU-014 Single surface box for 7 or 8 rows 6

9740052 CSU-015 Single surface box for 9 or 10 rows 6

9740053 CSU-016 Single surface box for 11 or 12 rows 6

9740054 CSU-017 Single surface box for 13 or 14 rows 6

9740055 CSU-018 Single surface box for 15 or 16 rows 12

9740051 9740056 CSU-019 Single surface box for 15 or 16 rows plus


doubLe upper module 12

DOUBLE SURFACE BOXES


•The appropriate box should be selected according to the number of rows of the push-button
entrance panel and entrance panel module with audio unit, video unit, card holder or blank.

CODE TYPE DESCRIPTION PACK

9740057 CSU-021 Double surface box for 1 or 2 rows 16

9740058 CSU-022 Double surface box for 3 or 4 rows 6

9740059 CSU-023 Double surface box for 5 or 6 rows 3


9740060

9740060 CSU-024 Double surface box for 7 or 8 rows 3

9740061 CSU-025 Double surface box for 9 or 10 rows 3

9740062 CSU-026 Double surface box for 11 or 12 rows 3

9740063 CSU-027 Double surface box for 13 or 14 rows 3

9740064 CSU-028 Double surface box for 15 or 16 rows 4

9740064 9740065 CSU-029 Double surface box for 15 or 16


rowsplus double upper module 4

ALCAD - 35
A C C E S S

TRIPLE SURFACE BOXES


•The appropriate box should be selected according to the number of rows of the push-button
entrance panel and entrance panel module with audio unit, video unit, card holder or blank.

CODE TYPE DESCRIPTION PACK


9740068 9740066 CSU-031 Triple surface box for 1 or 2 rows 3

9740067 CSU-032 Triple surface box for 3 or 4 rows 3

9740068 CSU-033 Triple surface box for 5 or 6 rows 3

9740069 CSU-034 Triple surface box for 7 or 8 rows 3

9740070 CSU-035 Triple surface box for 9 or 10 rows 4

9740071 CSU-036 Triple surface box for 11 or 12 rows 4

9740072 CSU-037 Triple surface box for 13 or 14 rows 4


9740072
9740073 CSU-038 Triple surface box for 15 or 16 rows 4

9740074 CSU-039 Triple surface box for 15 or 16 rows plus


double upper module 4

9740020

ANGULAR SINGLE SURFACE BOXES


•The appropriate box should be selected according to the number of rows of the push-button
entrance panel and entrance panel module with audio unit, video unit, card holder or blank.

CODE TYPE DESCRIPTION PACK

9740020 CSU-111 Angular single surface box 1 or 2 rows 10

9740023 9740021 CSU-112 Angular single surface box 3 or 4 rows 12

9740022 CSU-113 Angular single surface box 5 or 6 rows 18

9740023 CSU-114 Angular single surface box 7 or 8 rows 6

9740024 CSU-115 Angular single surface box 9 or 10 rows


6

9740025 CSU-116 Angular single surface box 11 or 12 rows 12

9740026 CSU-117 Angular single surface box 13 or 14 rows 5

9740027 CSU-118 Angular single surface box 15 or 16 rows 12

9740028 CSU-119 Angular single surface box 15 or 16 rows plus


double upper module 12

9740028

ALCAD - 36
S O R I E S

SINGLE RAIN-SHIELDS
•The appropriate box should be selected according to the number of rows of the push-button
entrance panel and entrance panel module with audio unit, video unit, card holder or blank.

CODE TYPE DESCRIPTION PACK

9740075 VIS-011 Rain-shield for 1-2 rows 20


9740075
9740076 VIS-012 Rain-shield for 3-4 rows 20
9740077 VIS-013 Rain-shield for 5-6 rows 12
9740078 VIS-014 Rain-shield for 7-8 rows 10
9740079 VIS-015 Rain-shield for 9-10 rows 10
9740080 VIS-016 Rain-shield for 11-12 rows 10
9740081 VIS-017 Rain-shield for 13-14 rows 10
9740082 VIS-018 Rain-shield for 15-16 rows 18
9740083 VIS-019 Rain-shield for 15-16 rows
plus double upper module 18
9740077

DOUBLE RAIN-SHIELD
•The appropriate box should be selected according to the number of rows of the push-button
entrance panel and entrance panel module with audio unit, video unit, card holder or blank.

CODE TYPE DESCRIPTION PACK

9740084 VIS-021 Rain-shield for 1-2 rows 10


9740086
9740085 VIS-022 Rain-shield for 3-4 rows 10
9740086 VIS-023 Rain-shield for 5-6 rows 5
9740087 VIS-024 Rain-shield for 7-8 rows 5
9740088 VIS-025 Rain-shield for 9-10 rows 5
9740089 VIS-026 Rain-shield for 11-12 rows 5
9740090 VIS-027 Rain-shield for 13-14 rows 5
9740091 VIS-028 Rain-shield for 15-16 rows 5
9740092 VIS-029 Rain-shield for 15-16 rows
plus double upper module 5
9740090

TRIPLE RAIN-SHIELD
•The appropriate box should be selected according to the number of rows of the push-button
entrance panel and entrance panel module with audio unit, video unit, card holder or blank.

CODE TYPE DESCRIPTION PACK

9740093 VIS-031 Rain-shield for 1-2 rows 5


9740095
9740094 VIS-032 Rain-shield for 3-4 rows 5
9740095 VIS-033 Rain-shield for 5-6 rows 6
9740096 VIS-034 Rain-shield for 7-8 rows 5
9740097 VIS-035 Rain-shield for 9-10 rows 8
9740098 VIS-036 Rain-shield for 11-12 rows 5
9740099 VIS-037 Rain-shield for 13-14 rows 5
9740018 VIS-038 Rain-shield for 15-16 rows 5
9740019 VIS-039 Rain-shield for 15-16 rows
plus double upper module 5

9740018
ALCAD - 37
A C C E S S

DECORATIVE FITTING FOR ENTRANCE PANELS


CODE TYPE DESCRIPTION PACK

9740014 TOP-001 Decorative fitting: 2 grey, 2 blue, 2 deep red 100


9740014
9740001 TOP-100 Customised Decorative Fittings 100

9740029 TOP-002 Decorative fittings in blue colour 75

9740001 9740030 TOP-003 Decorative fittings in deep red colour 75

DECORATIVE FRAMES FOR ENTRANCE PANELS


•Made from anodised aluminium.
•Made to measure, MAR-901 (010,250,390): Decorative frame fror double panel, for CMO-010 flush-
mounted box, external width 250 mm. and external height 390 mm.

CODE TYPE DESCRIPTION PACK

9740047
* MAR-900 Generic cover frame with single enttrance panel 1
9740016* MAR-901 Generic cover frame with double enttrance panel 1
9740017* MAR-902 Generic cover frame with triple enttrance panel 1
9740047

ACCESSORIES
ELECTRIC LOCKS
CODE TYPE DESCRIPTION PACK

9620013 ALM-080 Electric locks with high power consumption 9


9730005 AAL-001 Accessory that allows to use entrance panel modules
9620013 9730018 with 4+N audio unit and electronic call in installations
with buzzer call telephones 18
9730006 APC-001 Accessory that allows to activate a single electric lock from
several entrance panels with independent power supply 18
Accessory required for the use of the electronic call
9730018 AAL-120 extension or any other device which can be activated 18
9730005 9730006
by means of abn electronic call in installations with
digital telephones
9730019 AAL-200 Electronic call extension. To be used with telephones 18
and monitors in both conventional and digital systems.
9730023 9730024 With digital telephones, the use of an accessory
(namely AAL-120) is required.

9730023 ASC-001 Swich selector accessory activated by means of exter-


nal control signal. Applications ¡: seeing images from
a second camera, activating a second electric lock by
means of an auxiliary button, etc. 18
9730019 9730021 9730024 AAV-001 Accessory to adapt the video signal 18
Switch selector accessory activated by means of elec-
9730021 ASC-050 tronic call, buzzer call or external signal. Application: 18
activation by the call, auxiliary pushbutton, etc. of
devices connected to the mains (lights, sirens, etc.)
ALCAD - 38
S O R I E S

ELECTRIC LOCKS
9730000 ABR-001 Standard electric lock 50
9730001 ABR-002 Standard electric lock with manual release 50
9730002 ABR-003 Automatic electric lock 50
9730003 ABR-004 Automatic electric lock with manual release 50
9730004 CNP-001 Door contact 50
9730000
9730033 ESC-010 Large Shield electric locks 10

DECORATIVE FRAMES FOR MONITORS


CODE TYPE DESCRIPTION PACK

9730049 SSM-001 Desktop support for monitor (Does not include the
connection bracket for monitor) 8
9730035 MAE-001 Decorative frame monitor, 250 x 275 mm
(external width) 10
9730036 MAE-002 Decorative frame monitor, 250 x 325 mm
(external width) 10
•Made to measure, MAE-900 (210, 260): decorative frame for monitor, with external width of 210
9730004 mm. and height of 260 mm.
9730034 MAE-900 Decorative frame monitor, made to measure
upon request 1

UNIVERSAL ELECTRONIC PRODUCTS


TELEPHONES
CODE TYPE DESCRIPTION PACK
9600002 TUN-001 Telephone with electronic or buzzer call
9730034 (Universal) 10/60
9600013 TUN-101 Customised Universal Telephone 1 push button
10/60
9600011 TUN-002 Telephone with electronic or buzzer call
(Universal) 2 push button 10/60

ENTRANCE PANEL WITH AUDIO UNIT


9670008 9670024
CODE TYPE DESCRIPTION PACK
9670008 MAN-051 Entrance panel with Universal 4+N Audio unit with
electronic and buzzer call 12
9670024 MMN-051 Entrance panel with Universal 4+N Audio unit,
electronic and buzzer call. With card-holder. 9

CABLES FOR ELECTRONIC DOOR ENTRY SYSTEM


CODE TYPE DESCRIPTION PACK
9600002 9600013
9750000 CAB-032 Sleeved cable 6 x 0,25 mm2 100
9750001 CAB-052 Sleeved cable 10 x 0,25 mm2 100
9750002 CAB-004 Sleeved cable 2 x 0,5 mm2 100
9750003 CAB-034 Sleeved cable 6 x 0,5 mm2 100
9750004 CAB-054 Sleeved cable 10 x 0,5 mm2 100
9750005 CAB-007 Sleeved cable 2 x 1 mm2 100
9750006 CAB-117 Sleeved cable 4 x 1 mm2 y coaxial 100
9750007 CAT-001 UTP category 5E twisted pair cable 100

ALCAD - 39
M E A S
TELEPHONE TRIPLE UPPER MODULE CODE
84 mm 50.6 mm 9600001 9600012
9600002 9600013
128 mm 12 mm 9670071
9600003 9600014 9670015
9670017
224 mm

9600007 9600018

174,5 mm
9600009 9670029
9600011 9670103
9670105

COMPACT PANEL CODE


128 mm 12 mm
9670033
POWER SUPPLY 9670013
9670100

147 mm
175 mm 60 mm
9620001
9620002 9800006
9620006
90 mm

9620011
230V~ ++
9620014
TELEPHONE FOR MAIN PERIMETER ENTRANCE CODE HEIGH
128 mm 62,6 mm
B
9680001 339
MONITOR CODE 9680002 387
197 mm 64.3 mm 9680003 435
9630000 9680004 483
B mm
9630006
9630008
224 mm

AUDIO KIT CODE

128 mm 12 mm 114 mm 45 mm
9700000
CONNECTION BRAKET FOR MONITOR CODE ARRIBA
UP
HAUT
9700003
131 mm
147 mm

166 mm
9700004
9700018
9630002
9700021
9630003
9630004
193 mm

12 mm
PROG

128 mm
ON OFF

114 mm 45 mm
9630005
9700001
9700005
ARRIBA
UP
HAUT

9700006
195 mm

179 mm

LOWER MODULE CODE HEIGHT


128 mm 12 mm
B B B
9660014 68,5 9660010 356,5 9660056 260,5 128 mm 12 mm 114 mm 45 mm
9660015 68,5 9660011 356,5 9660057 260,5
B mm (función del modelo)

9660000 116,5 9660012 404,5 9660058 308,5 9700002


9700007
ARRIBA
UP
HAUT

9660001 116,5 9660013 404,5 9660059 308,5


9660002 164,5 9660048 68,5 9660060 356,5 9700008
227 mm
243 mm

9660003 164,5 9660049 68,5 9660061 356,5


9660004 212,5 9660050 116,5 9660062 404,5
9660005 212,5 9660051 116,5 9660063 404,5
9660006 260,5 9660052 164,5
9660007 260,5 9660053 164,5
9660008 308,5 9660054 212,5
9660009 308,5 9660055 212,5 VIDEO KIT CODE
128 mm 12 mm 9720000
114 mm 45 mm
9720002
SIMPLE UPPER MODULE CODE ARRIBA
UP
HAUT
9720004
9670001 9670007 9720005
179 mm
195 mm

128 mm 12 mm 9670004 9670027 9720009


9670006 9670031 9720012
78.5 mm

9670042 9670018 9720013


9670012 9670021 9720014
9670101 9670008 9720015

DOUBLE UPPER MODULE CODE TAP-OFFS / SPLITTERS CODE


88 mm 24 mm
128 mm 12 mm 9670022 9670097 88 mm 21 mm
9670025 9670057 9730031
DIV-034
A
40 mm

9670085 9670061 9730032


57 mm

cod.9730015
126,5 mm

9670099 9670043
T1+ T1 T1 T1+ T1+ T1 T1+ T1 T1+ T1 T1+ T1

9670098 9670047 9730015


B
9670016 9670086 9730016
A B
ALCAD - 40 9670102 9670014
9670104 9670024
U R E S

FRAME FOR REPLACEMENT DOUBLE RAIN-SHIELD CODE HEIGHT


3mm 300 mm 3mm 280 mm 42 mm
250 mm B B
9740084 170 9740089 410

B mm (función del modelo)


9740085 218 9740090 458
9740086 266 9740091 506
ARRIBA ARRIBA
UP UP
HAUT HAUT
275 mm

325 mm
9740087 314 9740092 554
9740088 362

9730035 TRIPLE RAIN-SHIELD CODE HEIGHT


9730036
408 mm 42 mm
FLUSH MOUNTED BOX CODE HEIGHT B B
9740093 170 9740098 410

B mm (función del modelo)


114 mm 45 mm
B B 9740094 218 9740099 458
B mm (función del modelo)

ARRIBA
UP
HAUT
9740005 131 9740010 371 9740095 266 9740018 506
9740006 179 9740011 419 9740096 314 9740019 554
9740007 227 9740012 467 9740097 362
9740008 275 9740015 515
9740009 323
KEYBORD MODULES CODE
128 mm 12 mm
SEPARATOR FOR FLUSH MOUNTED BOX CÓDIGO 9800000
243 mm
9740004 9800001
15 mm 9800002
114 mm 114 mm 9800011
291 mm
15 mm
ARRIBA ARRIBA
UP UP
HAUT HAUT

1 2 3

4 5 6

7 8 9

C 0

Incremento por cada INTERNAL COMMUNICATION MODULE CODE


juego de separadores Ensamblaje 2 cajas de empotrar 175 mm 60 mm
9650001
SINGLE SURFACE BOX CODE HEIGHT
152 mm
90 mm

50 mm
B B
B mm (función del modelo)

9740048 170 9740053 410 230V~ I2 I1

9740049 218 9740054 458


9740050 266 9740055 506
9740051 314 9740056 554 ELECTRIC LOCK CODE
9740052 362 31 mm 25 mm
9730000 ELECTRICK LOCK SHIELD
25 mm
9730001 9730033
DOUBLE SINGLE SURFACE BOX CODE HEIGHT 9730002
280 mm 50 mm
9730003
B B
160 mm
100 mm

9740057 170 9740062 410


B mm (función del modelo)

9740058 218 9740063 458


9740059 266 9740064 506
250 mm
30 mm

9740060 314 9740065 554


9740061 362 3 mm

DOOR CONTACT
TRIPLE SURFACE BOX CODE HEIGHT 13,5 mm 22 mm 13,5 mm 8,6 mm

408 mm 50 mm B B 3 mm
9740066 170 9740071 410
57,7 mm
57,7 mm
B mm (función del modelo)

9740067 218 9740072 458


9740068 266 9740073 506
9740069 314 9740074 554
9740070 362 9730004
5 mm 5 mm
Contacto de puertas - Macho Contacto de puertas - Hembra

ANGULAR SINGLE SURFASE BOX HEIGHT ACCESSORIES CODE


152 mm
B B 21 mm
88 mm
9740020 170 9740025 410 9730005
B mm (función del modelo)

9740021 218 9740026 458 9730006


40 mm

ASC-050
cod. 9730021

Vista superior 9740022 266 9740027 506 2


S
5
S
6
5A / 250V~

9730023
9730024
Ctrl1 Ctrl2 C NO NC

9740023 314 9740028 554


90 mm

90
o
9740024 362
50 mm 30 mm

SINGLE RAIN-SHIELD CODE HEIGHT


9730019
152 mm 42 mm
B B
75 mm

9740075 170 9740080 410


B mm (función del modelo)

9740076 218 9740081 458


9740077 266 9740082 506
9740078 314 9740083 554
9740079 362
ALCAD - 41
R E S U M E O F C O D E

CODE TYPE CODE TYPE CODE TYPE CODE TYPE EURO


LINE 960 LINE 967 SERIE 973 9740065 CSU-029
9600001 TEL-001 9670001 MAN-010 9730000 ABR-001 9740066 CSU-031
9600002 TUN-001 9670004 MAN-030 9730001 ABR-002 9740067 CSU-032
9600003 TES-001 9670006 MAN-060 9730002 ABR-003 9740068 CSU-033
9600007 TED-001 9670007 MAN-041 9730003 ABR-004 9740069 CSU-034
9600009 TEL-002 9670008 MAN-051 9730004 CNP-001 9740070 CSU-035
9600011 TUN-002 9670012 MVN-004 9730005 AAL-001 9740071 CSU-036
9600012 TES-002 9670013 MVN-901 9730006 APC-001 9740072 CSU-037
9600013 TUN-101 9670014 MDN-044 9730014 AIB-000 9740073 CSU-038
9600014 TIN-001 9670015 MDT-044 9730015 DIV-034 9740074 CSU-039
9600018 TEL-101 9670016 MDN-084 9730016 DIV-134 9740075 VIS-011
9670017 MDT-084 9730017 ACO-000 9740076 VIS-012
LINE 962 9670018 MTN-000 9730018 AAL-120 9740077 VIS-013
9620001 ALA-040 9670021 MLN-000 9730019 AAL-200 9740078 VIS-014
9620002 ALA-020 9670022 MMN-010 9730021 ASC-050 9740079 VIS-015
9620011 ALM-040 9670024 MMN-051 9730023 ASC-001 9740080 VIS-016
9620013 ALM-080 9670025 MMN-030 9730024 AAV-001 9740081 VIS-017
9620014 ALC-070 9670027 MVN-001 9730030 COL-000 9740082 VIS-018
9670029 MDT-081 9730031 DIV-024 9740083 VIS-019
LINE 963 9670031 MVN-101 9730032 DIV-124 9740084 VIS-021
9630000 MVB-001 9670033 MVN-900 9730033 ESC-010 9740085 VIS-022
9630002 SCM-010 9670042 MAN-080 9730034 MAE-900 9740086 VIS-023
9630003 SCM-020 9670043 MDN-041 9730035 MAE-001 9740087 VIS-024
9630004 SCM-030 9670047 MDN-141 9730036 MAE-002 9740088 VIS-025
9630005 SCM-040 9670057 MDN-081 9730049 SSM-001 9740089 VIS-026
9630006 MVB-002 9670061 MDN-181 9740090 VIS-027
9640006 TCB-130 9670071 MDT-041 LINE 974 9740091 VIS-028
9670085 MMN-080 9740001 TOP-100 9740092 VIS-029
LINE 965 9670086 MLT-000 9740004 CEM-001 9740093 VIS-031
9650001 GCI-001 9670097 MMN-041 9740005 CMO-002 9740094 VIS-032
9650007 MDA-300 9670098 MCN-041 9740006 CMO-004 9740095 VIS-033
9650009 MDA-400 9670099 MCN-080 9740007 CMO-006 9740096 VIS-034
9670100 MVN-902 9740008 CMO-008 9740097 VIS-035
LINE 966 9670101 MVN-201 9740009 CMO-010 9740098 VIS-036
9660000 MPS-003 9670102 MDN-241 9740010 CMO-012 9740099 VIS-037
9660001 MPS-004 9670103 MDT-241 9740011 CMO-014
9660002 MPS-005 9670104 MDN-281 9740012 CMO-016 LINE 975
9660003 MPS-006 9670105 MDT-281 9740014 TOP-001 9750000 CAB-032
9660004 MPS-007 9740015 CMO-018 9750001 CAB-052
9660005 MPS-008 LINE 968 9740016 MAR-901 9750002 CAB-004
9660006 MPS-009 9680001 COA-010 9740017 MAR-902 9750003 CAB-034
9660007 MPS-010 9680002 COA-012 9740018 VIS-038 9750004 CAB-054
9660008 MPS-011 9680003 COA-014 9740019 VIS-039 9750005 CAB-007
9660009 MPS-012 9680004 COA-016 9740020 CSU-111 9750006 CAB-117
9660010 MPS-013 9680008 TCD-001 9740021 CSU-112 9750007 CAT-001
9660011 MPS-014 9740022 CSU-113
9660012 MPS-015 LINE 970 9740023 CSU-114 LINE 980
9660013 MPS-016 9700000 KAS-01001 9740024 CSU-115 9800000 PAK-01000
9660014 MPS-001 9700001 KAS-01003 9740025 CSU-116 9800001 PDK-01100
9660015 MPS-002 9700002 KAS-01005 9740026 CSU-117 9800002 PTN-00000
9660016 MKD-900 9700003 KAD-01001 9740027 CSU-118 9800006 PNK-00000
9660048 MPD-001 9700004 KAD-01002 9740028 CSU-119 9800011 PDK-01400
9660049 MPD-002 9700005 KAD-01003 9740029 TOP-002 9800012 PAK-03000
9660050 MPD-003 9700006 KAD-01004 9740030 TOP-003 9800016 PAK-02000
9660051 MPD-004 9700007 KAD-01005 9740047 MAR-900 9800017 PAK-04000
9660052 MPD-005 9700008 KAD-01006 9740048 CSU-011
9660053 MPD-006 9700018 KAS-01201 9740049 CSU-012
9660054 MPD-007 9700021 KAD-01201 9740050 CSU-013
9660055 MPD-008 9740051 CSU-014
9660056 MPD-009 LINE 972 9740052 CSU-015
9660057 MPD-010 9720000 KVS-08101 9740053 CSU-016
9660058 MPD-011 9720002 KVD-08101 9740054 CSU-017
9660059 MPD-012 9720004 KVS-09101 9740055 CSU-018
9660060 MPD-013 9720005 KVD-09101 9740056 CSU-019
9660061 MPD-014 9720009 KVS-09201 9740057 CSU-021
9660062 MPD-015 9720012 KVS-08401 9740058 CSU-022
9660063 MPD-016 9720013 KVD-08401 9740059 CSU-023
9660064 MPD-900 9720014 KVS-09401 9740060 CSU-024
9660065 MPD-901 9720015 KVD-09401 9740061 CSU-025
9720030 KOS-08201 9740062 CSU-026
9740063 CSU-027
9740064 CSU-028

ALCAD - 42
G E N E R A L T E R M S

The acceptance of orders by ALCAD S.A. implies the acceptance of the following general terms of trade.
These terms take priority over the conditions of purchase that may figure on client order forms or other docu-
ments.

1. PRICES
Our unit prices are ex-works. The price that will be applied is the current price in the country of sale at the date
of receipt of order. Orders accepted by our agents are only formalised following our confirmation.

2. TRANSPORT
Transportation costs will be paid for by the client.
The risks of transport and problems that could occur during transportation will be at the expense of the client,
even when the goods are shipped free delivered. The client will adopt the necessary measures with the transport
company the moment the goods are received and will have to confirm by registered letter the event of any loss
or damage caused to the goods, and send a copy of the same letter to the shipping agent.

3. DELIVERY TIMES, DELIVERIES, RETURNS AND COMPLAINTS


ALCAD S.A. will only accept orders that are confirmed in writing. Delivery times are only indicative and the
delays that may occur cannot be held as a reason to refuse the acceptance of the material or as a cause for com-
pensation.
ALCAD S.A. reserves the right to organise the delivery of the goods in one or several shipments, and to invoice
the goods in accordance with the agreed terms.
No return of material will be allowed without the express prior authorisation of ALCAD S.A. In the event that the
return of the material is accepted, the goods must be in perfect working condition and in their original packing
and sent to us carriage-paid with a photocopy of the authorisation of the return and the initial invoice.
Any complaint regarding the delivered material must be made within the 8 days that follow the reception of the
goods.

4. GUARANTEE
The material is guaranteed for one year following the date of the invoice for the ALCAD products to the end client
and will be validated by the presentation of the purchase document of the product in question.
The guarantee is strictly limited to the replacement of the materials supplied by ALCAD, and does not cover any
damage or breakdowns due to misuse, incorrect installation, or prohibited manipulation or handling of the mate-
rials, carried out by the client before returning the goods to ALCAD.
This guarantee does not imply any liability on part of ALCAD for compensation or damages whatsoever.

5. TERMS AND CONDITIONS OF PAYMENT


Each of the agreed terms and conditions of payment will be negotiated with the client and confirmed in writing.
Any delay in the agreed date of payment could be cause for an additional invoice to cover the costs of delay and
damages.

6. RESERVE OF OWNERSHIP CLAUSE


ALCAD S.A. reserves the rights to full ownership of the goods until the purchaser has totally satisfied the full pay-
ment of the agreed price. The purchaser is obliged to make every effort to preserve and maintain the goods in
perfect order and to cover the goods with a fully comprehensive insurance policy. Should the purchaser fail to
satisfy any of their obligations, ALCAD S.A. may exercise its rights of ownership and withdraw the goods or
demand the fulfilment of the obligation of payment.

7. COMPETENT JURISDICTION
For any question relating to the fulfilment or interpretation of the contract or its incidence, the parties, with the
express renunciation of any other body or authority that may correspond to them, agree to submit any dispute to
the competence of the courts and tribunals in the jurisdiction of our registered head office.

ALCAD - 43
2000-11-05 Specifications subject to modifications without prior notice

You might also like