Proposed Firetank
Proposed Firetank
CINA
ARA
BID
JL .
ATA
R DIN
ANDA
Ladder
A1 B1
ISK
OTTO
JL. MT
JL .
Hatch moved to top of Firetank slab NOTES:
Slab 120mm thick slab. (Design) +3350mm 1. ALL DIMENSIONS ARE IN "mm" & LEVELS ARE IN
"m", UNLESS OTHERWISE SPECIFIED.
2. THE INSTALLATION AND DESIGN SHALL COMPLY
WITH THEHEALTH AND SAFETY AT WORK ACT, AND
ALL REGULATIONS.
3. THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH ALL ASSOCIATED EQUIPMENT SCHEDULES
Gantry 1 AND MECHANICAL,ELECTRICAL, STRUCTURAL AND
ARCHITECTURAL DRAWINGS.
LEVEL 1M
1650
24.450
950
3650
LEVEL 1
20.250
CLIENT
Section Firetank
2 1 : 150
Project Managers|QS Consultants
FIRE TANK #1
RED: M&E Consultant
3 ANSON ROAD #17-03 SPRINGLEAF
effective storage height: 3.5m
1
TOWER SINGAPORE 079909
recommended constructed tank height: 4.65m t: +65 6226 3106 | www.red-eng.com
0 1.5 3 4.5 6 7.5 pls verify the tank dimension and ensure the water capacity of
240m3 is achievable
SINGAPORE 069542
Tel: + 65 63376777, Fax:+ 6563396956
www.awparchitects.com
B1 Proj. email:
m To demonstrate the details of incoming pipe din, overflow line, C&S CONSULTANT:
warning line, water line, warning pipe Dw, low water line etc.
Ladder inside firetank GRAHA CHANTIA L3, JL BANGKA RAYA NO. 6 JAKARTA SELATAN 12720
TEL: +6221 719 0011 | ttw.com.au | ttw@ttwindonesia.com
2225
The water tank is used for PT. Berca Mandiri Perkasa
both water sprinkler demand JOINT OPERATION
and fire hydrant. Jl. RC. Veteran No. 4 Bintaro,Jakarta
12330, Indonesia.
Tel. 021-7361979, Fax. 021-7362003
water demand for sprinkler
(SNI 03-3989-2000 table 5.3.2): 1350 GC's DC CONSULTANT:
220 m3 HEWLETT-PACKARD
ENTERPRISE
water demand for hydrant for
Data Center Technology Service
combined system (SNI
03-1745-2000 clause 7.9.1.3):
A1
227.1 m3
FOR INFORMATION
FIRE TANK #2
the 227.1 m3 shall be taken as
worse case, and round up to Skema Fire tank
3
240 m3 as the design effective
capacity of the tank..
8
Pls redesign the dimension of SCALE 1: SIGNATURE DATE
4
CHECKED
m APPROVED
DRAWING NO. REV.NO.
1 : 150
N
CINA
ARA
BID
JL .
ATA
R DIN
ANDA
ISK
OTTO
JL. MT
. HA
RYON
O
JL .
NOTES:
1. ALL DIMENSIONS ARE IN "mm" & LEVELS ARE IN
"m", UNLESS OTHERWISE SPECIFIED.
2. THE INSTALLATION AND DESIGN SHALL COMPLY
WITH THEHEALTH AND SAFETY AT WORK ACT, AND
ALL REGULATIONS.
3. THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH ALL ASSOCIATED EQUIPMENT SCHEDULES
AND MECHANICAL,ELECTRICAL, STRUCTURAL AND
ARCHITECTURAL DRAWINGS.
C1
CLIENT
B
10700
B1 2206 Project Managers|QS Consultants
1480
PT. TURNER & TOWNSEND
International Financial Centre, 26F Jl. Jend. Sudirman Kav 22-23, Jakarta
Selatan 12920 Tel: +62 21 252 3895 www.turnerandtownsend.com
M&E Consultant
3 ANSON ROAD #17-03 SPRINGLEAF
TOWER SINGAPORE 079909
t: +65 6226 3106 | www.red-eng.com
5799
240 m3
7604
Architect
AWP PTE LTD
143 CECIL STREET, #12-00 GB BUILDING
SINGAPORE 069542
Tel: + 65 63376777, Fax:+ 6563396956
www.awparchitects.com
Proj. email:
awp220603c@awparchitects.com
C&S CONSULTANT:
A
GENERAL CONTRACTOR:
PT. Berca Buana Sakti
PT. Berca Mandiri Perkasa
JOINT OPERATION
Jl. RC. Veteran No. 4 Bintaro,Jakarta
12330, Indonesia.
Tel. 021-7361979, Fax. 021-7362003
GC's DC CONSULTANT:
HEWLETT-PACKARD
ENTERPRISE
Data Center Technology Service
FOR INFORMATION
GANTRY
CHECKED
CHECKED
5 6 7 8 9 10 APPROVED
DRAWING NO. REV.NO.