TDRS 003

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

DOC Ref

Test Data Report for


Title Switch Filter Bank-Low Date 18/06/2023
Bank
Page 1 OF 6

Test Data Report


For
Switch Filter Bank –Low Band

Prepared by Checked by Approved by

ISSUE C ONTROL & STATUTORY WARNING


This document is the property of The RFMW Innovations Lab private Limited, Bangalore. Unauthorized usage of this
document is prohibited. No part of the document shall be copied or reproduced by anyone without prior written
permission from the management. Any changes required to be incorporated shall be as per the procedure detailed. This
is a Dynamic document which is subject to periodic review and amendments for continual improvement of the system.

RESTRICTED
DOC Ref
Test Data Report for
Title Switch Filter Bank-Low Date 18/06/2023
Bank
Page 2 OF 6

TDRS 1. Power Consumption Measurement

DUT: SFB-LB Date: 22/06/23


SL.No: 003

Applied Measured
Power (W)
Voltage (V) Current (A)

+8.5V 1.09 9.3

RESTRICTED
DOC Ref
Test Data Report for
Title Switch Filter Bank-Low Date 18/06/2023
Bank
Page 3 OF 6

TDRS 2. Gain and Rejection Measurement Test

DUT: SFB-LB Date: 22/06/23


SL.No: 003 I/P Power:-30 dBm

Band 1:400-630MHz

Freq (MHz) 400 630 352 706


CH1(dB) 21.2 20.1 -50.7 -39.7
CH2(dB) 20.9 21.1 -63.7 -40.5
CH3(dB) 21.3 20.2 -51 -38.3

Band 2:630-1150MHz

Freq(MHz) 630 1150 554 1288


CH1(dB) 21.2 19.9 -40 -42.5
CH2(dB) 21.3 20.5 -37 -39
CH3(dB) 21.5 20.5 -38 -41.9

Band 3:1150-1380MHz

Freq(MHz) 1150 1380 1012 1546


CH1(dB) 22 20.5 -42 -41
CH2(dB) 22.2 21.0 -38.9 -44.5
CH3(dB) 22.2 21.3 -41.8 -41.3

Band 4:1380-1780MHz

Freq(MHz) 1380 1780 1214 1993


CH1(dB) 21.42 20.7 -39 -50
CH2(dB) 21.8 21.1 -45 -41.3
CH3(dB) 21.1 20.9 -42 -43.2

Band 5:1780-2200MHz

Freq(MHz) 1780 2200 1566 2464


CH1(dB) 20.7 19.9 -46.5 -46.8
CH2(dB) 20.1 20.1 -48.9 -41.1
CH3(dB) 21.1 21.0 -52.5 -64.5

RESTRICTED
DOC Ref
Test Data Report for
Title Switch Filter Bank-Low Date 18/06/2023
Bank
Page 4 OF 6

TDRS 3. Amplitude Tracking Measurement Test

DUT: SFB-LB Date: 22/06/23


SL.No: 003 I/P Power:-30 dBm

Band 1:400-630MHz

Freq(MHz) Max
CH1(dB) Reference
CH2(dB) ±1.1
CH3(dB) ±0.8

Band 2:630-1150MHz

Freq(MHz) Max
CH1(dB) Reference
CH2(dB) ±0.65
CH3(dB) ±0.95
Band 3:1150-1380MHz

Freq(MHz) Max
CH1(dB) Reference
CH2(dB) ±1
CH3(dB) ±1.1
Band 4:1380-1780MHz

Freq(MHz) Max
CH1(dB) Reference
CH2(dB) ±0.9
CH3(dB) ±0.7
Band 5:1780-2200MHz

Freq(MHz) Max
CH1(dB) Reference
CH2(dB) ±0.85
CH3(dB) ±1.15

RESTRICTED
DOC Ref
Test Data Report for
Title Switch Filter Bank-Low Date 18/06/2023
Bank
Page 5 OF 6

TDRS 4. Phase Tracking Measurement Test

DUT: SFB-LB Date: 22/06/23


SL.No: 003 I/P Power:-30 dBm

Band 1:400-630MHz

Freq(MHz) Max
CH1(Degree) Reference
CH2(Degree) ±4.5
CH3(Degree) ±5

Band 2:630-1150MHz

Freq(MHz) Max
CH1(Degree) Reference
CH2(Degree) ±2
CH3(Degree) ±4
Band 3:1150-1380MHz

Freq(MHz) Max
CH1(Degree) Reference
CH2(Degree) ±6
CH3(Degree) ±4
Band 4:1380-1780MHz

Freq(MHz) Max
CH1(Degree) Reference
CH2(Degree) ±7
CH3(Degree) ±6.5
Band 5:1780-2200MHz

Freq(MHz) Max
CH1(Degree) Reference
CH2(Degree) ±5.5
CH3(Degree) ±4

RESTRICTED
DOC Ref
Test Data Report for
Title Switch Filter Bank-Low Date 18/06/2023
Bank
Page 6 OF 6

TDRS 5. Switching Time Measurement

DUT: SFB-LB Date: 22/06/23


SL.No: 003

Switching
Measured(ns)
Time

400-630 48
1780-2200 49

RESTRICTED