HP2-K27 Exam questions:

1|Page
2|Page
3|Page
SSSU Command View Commands:

To view available storage systems, enter the following command:

LS SYSTEM

To select a storage system to manage, enter the following command:

SELECT SYSTEM system_name

ADD HOST
The ADD HOST command adds a host and its WWN to the list of hosts that can connect to virtual disks
in the current storage system. The ADD HOST command adds one FCA only. Use the “SET HOST”
(page 74) command to add each subsequent adapter.

NOTE: For all Windows 2012 hosts, HP recommends using Microsoft Windows 2012 host mode
while creating a host.

ADD HOST host_name WORLD_WIDE_NAME=FCA-WWN

CAPTURE CONFIGURATION newyear.txt, SSSU creates the files newyear_Step1A.txt,


newyear_Step1B.txt, newyear_Step1C.txt, newyear_Step2.txt, and
newyear_Step3.txt.

4|Page
New) Which statements are true when cabling the P6500 EVA? (select two)

A. A single SAS domain is supported


B. Odd-numbered cables (1,3) support one bus and even-numbered cables (2,4) support the other
bus
C. Dual SAS domains are supported
D. “Y” cables are used to enable each controller port to act as two ports

Connecting P65x0 EVA controllers to the disk enclosures (2C6D)


Y-cables (see Figure 56 (page 71)) are used to connect the P65x0 and enable each controller port
to act as two ports. The Y-cables provide connectivity to each SAS domain (indicated as DP-1
and DP-2 on the cables in the diagrams). The Y-cable connector labeled item 3 in Figure 56 (page
71) is the input to a controller port. The two connectors labeled item 4 in the figure are outputs to
a disk enclosure port. Each individual connectivity point from the Y-cable is the start of a SAS
domain
(P1 and P2 in Figure 56 (page 71)).

5|Page
New) For the HSV340 or HSV360 controllers, what is the last character of the port WWID for controller
1, host ports 1 and 2 ?

A. 9,8
B. 8,9
C. D,c
D. C,D

The EVA 4x00/6000/6100 series has two host ports per controller (A&B), whereas, for
the EVA 6400/8x00 Series there are four hosts ports per controller.

The WWN ending with digits 8,9,a,b represents Controller A host ports
"fp1,fp2,fp3,fp4" respectively, and those ending with c,d,e,f represents Controller B
hosts ports in the same way.

New1) Virtual disks configured as VRAID5 always provide what percent of disk group?

A. 50
B. 75
C. 80
D. 100

vRaid1 is 50% (actually.. Something like 48% I think is closer).

vRaid5 is about 80% (20% overhead)

vRaid6 is about 67% (33% overhead)

New2) The EVA balances performance and capacity across all drives by which process?

A. Virtual disk leveling


B. Distributed Virtual RAID
C. Distributed Sparing
D. Virtual Disk Sparing

6|Page
New3) Which statement is true about distributed virtual RAID (DVR)?

A. The location of each chunk of data changes dynamically


B. There is an advantage over traditional RAID because physical blocks of data are more easily
located
C. The storage administrator has control over the distribution of physical chunks of data
D. Chunks of data are held contiguously, resulting in faster data access

Distributed virtual RAID technology


In the EVA solution, the HSV controller and VCS enable disk virtualization through the
implementation of distributed virtual RAID (DVR) technology

New4) How many host ports are available on an HSV340/HSV360 controller pair?

A. 4
B. 6
C. 8
D. 12

What is the current tool used to translate raw hex event data to a readable format?

A. Navigator
B. HSVET
C. Event View EVA (EVE)
D. NAPP

Answer : B

New) What is the maximum storage capacity of one P6300 model 2C10D with 2TB LFF drives?

A. 120 TB
B. 180 TB
C. 240 TB
D. 480 TB

7|Page
New) What is the key distinguishing feature of the P6500 SAS topology?

A. “Y” cables are used


B. Provides up to 120 LFF drives or 450 SFF drives
C. Uses only two SAS lanes between shelves
D. All 20 shelves can be used if all SFF drives are used

New) Which statement is true regarding the PDUs and PDMs in an EVA rack?

A. Each PDU distributes AC to a maximum of eight PDMs


B. The PDUs connect to the same wall receptacle
C. Drive enclosure power supplies on the left connect to the PDMs on the left
D. You can use PDMs for other power requirements in addition to the EVA

8|Page
The standard power configuration for any HP Enterprise Virtual Array rack is the fully redundant
configuration. Implementing this configuration requires:
Two separate circuit breaker-protected, 30-A site power sources with a compatible wall
receptacle.
One dual PDU assembly. Each PDU connects to a different wall receptacle.
Four to eight (depending on the rack) Power Distribution Modules (PDMs) per rack. All PDMs
are located (side by side in pairs) on the left side of the rack. Each set of PDMs connects to
a different PDU.
◦ Eight PDMs for 42U, 47 U, and 42U 5642 racks
◦ Six PDMs for 36U racks
◦ Four PDMs for 22U racks
Each controller enclosure has two power supplies:
Controller PS 1 connects to the left PDM in a PDM pair with a black, 66 cm (26 inch)
power cord.

◦ Controller PS 2 connects to the right PDM in a PDM pair with a gray, 152 cm (60 inch)
power cord.

Depending on the rack, there can be up to eight PDMs mounted in the rear of the rack:
The PDMs on the left side of the PDM pairs connect to PDU 1.
The PDMs on the right side of the PDM pairs connect to PDU 2.
Each PDM has seven AC receptacles. The PDMs distribute the AC power from the PDUs to the
enclosures. Two power sources exist for each controller pair and disk enclosure. If a PDU fails, the
system will remain operational.

New) Which power protection is used on the PDMs in an EVA rack?

A. Circuit breaker
B. Trip breaker
C. 16A fuse
D. AC receptacle

9|Page
New) For a P6000 series EVA you have the choice of loading Command View on which two components?
(select two)

A. HSV340 or HSV360 controller


B. Management Module
C. Management Switch
D. Management Server

New) After installing Command View accounts for Windows users must be created and assigned to what
user groups? (select two)

A. HP Users
B. HP Storage
C. HP Admins
D. HP Storage Users
E. HP Storage Admins

New) What does the SSSU term spare policy translate to in Command View?

A. Disk failure protection level


B. Number of spares available for reconstruction
C. Actions to take if sparing is required
D. Storage system level protection

What is Spare policy (SPARE_POLICY)

Determines the amount of storage space, if any, set aside for use in the event
that disks fail. The space set aside is not in numbers of physical disks. It is the
equivalent amount of storage space spread across all disks.
NOTE:
Using a spare policy of none can cause data loss and is not
recommended.
• None—Reserves no space within a disk group to allow for data reconstruction
in case of a disk drive failure
• Single—Reserves space within a disk group to allow for data reconstruction
in case of a failure of one disk drive (default)
• Double—Reserves space within a disk group to allow for data reconstruction
in case of a failure of two disk drives

10 | P a g e
New) Which term represents a pointer-based copy, with space allocated as needed?

A. Fully-Allocated Snapshot
B. Demand-Allocated Snapshot
C. Snapclone
D. Business Continuous Volume

New) What is the command syntax for displaying a list of options available with the ls command?

A. ls option
B. ls all
C. ls !
D. ls ?

New) What can you view from the general controller properties page?

A. Blower properties (disk enclosure not controller)


B. Temperature Sensors
C. Power supply 1 and power supply 2 properties
D. XCS revision number

11 | P a g e
New) Which type of replication can you do across disk groups?

A. Fully-Allocated Snapshot

B. Demand-Allocated Snapshot

C. Snapclone

D. All Snapshots and Snapclones

New) On which page in Command View can you specify the events to capture as SNMP traps?
A. Set System Operational Policies
B. Set Host Options
C. Set Event Notification Options
D. Filter Events

New) How many copies of metadata are kept when the default disk group is created?

A. 3
B. 4
C. 5
D. 6

(see XCS release notes file)

New) Which button on the event log pages allows you to download raw data files to your local PC?

A. Filter Events
B. Get Log File
C. Get Event Log
D. View

To download events, use either “Get log file” or “Get Event File”

Three event logs are displayed from Command View:

- Management server event log (saved as ASCII file)


- Controller event log
- Controller Termination Event Log (saved as binary files)

12 | P a g e
13 | P a g e
New) What are the primary factors that must be considered when configuring disk groups? (select two)

A. Cost
B. Number of Luns
C. Availability
D. Number of hosts

New) Which components are customer replaceable units of the M6612 or M6625 drive enclosure?
(select two)

A. Cache battery
B. WOCP
C. Disk drive
D. Drive Enclosure Power Supply

New) Which factors are used to determine the number of disks required to deliver a given usable
capacity in an EVA storage system? (select two)

A. Hardware versus software data representation


B. Size of write cache
C. System metadata overhead
D. Number of LUNs presented

New) Which tool allows you to use the evaperf command or the EVA Performance Menu to build and
display a performance data collection?

A. Evaperf
B. EVA Performance Tool for Support
C. TLViz
D. Perfmon

New) Which tool allows you to use the evaperf command or the EVA Performance Menu to build and
display a performance data collection?

A. Evaperf
B. EVA Performance Tool for Support
C. TLViz
D. Perfmon

14 | P a g e
15 | P a g e
Q1) What is the default value for the disk failure protection level:

None / Single / Double / Triple?

Q2) What is the approximate maximum virtual disk size for a disk group with ten 36GB drives and a disk
protection level of Single?

134GB , 202GB, 270GB, 338GB?

Q3) The EVA balances performance and capacity across all disk drives by which process?

A. Virtual Disk Leveling


B. Distributed Virtual RAID
C. Distributed Sparing
D. Virtual Disk Sparing?

Q4) For a disk group, space is allocated in what size of segment and the chunk size is how many blocks?

A. 1MB, 256 blocks


B. 1MB, 512 blocks
C. 2MB, 256 blocks
D. 2MB, 512 blocks

Q5) In an EVA, what is the purpose of virtual disk leveling?

A. Dynamically distribute data blocks over many physical spindles to eliminate performance
bottlenecks?
B. Equalize disk capacity
C. Allocate space per disk group to recover from physical disk group failure
D. Build virtual disks from physical disks

16 | P a g e
Q6) What is the cache size of each HSV360 controller in a P6500 EVA?

1GB, 2GB, 4GB, 8GB

Q7) How are the controller 1 and 2 connections made to the cache batteries?

A. Controller 1 is connected to cache battery 1, controller 2 is connected to cache batter 2


B. Controllers 1 and 2 are connected to cache battery 1, Controllers 1 and 2 are connected to cache
battery 2
C. Controller 1 is connected to cache battery 2, controller 2 is connected to cache battery 1
D. Controller 1 and 2 are connected to cache battery 1 or controllers 1 and 2 are connected to
cache battery 2

Q8) How many batteries and cells are contained in each HSV340 or HSV360 controller battery pack?

A. 2 batteries, 2 cells
B. 2 batteries, 4 cells
C. 3 batteries, 3 cells
D. 3 batteries, 6 cells

Q9) On the web-based OCP, which level of user functionality allows you to view the last controller fault?

A. Global
B. User
C. Administrative
D. Service

WOCP features
The HP EVA web-based operator control panel (WOCP) is primarily intended for use by system
administrators and service personnel. When you log in as an administrator, the Administrator options,
Service options, and User options are available. When you log in as a user, only the User options are
available. The following menu options are available in the WOCP.
Administrator options
These options allow administrators to view and change storage system settings.
• Configure Administrator login options
• Configure controller device ports
• Configure controller host ports
• Configure network options
• Power down or restart system
• Uninitialize system
• Update management module firmware
• View detailed system information
Service options
These options allow administrators and service personnel to view detailed service logs.
• View last controller fault
• View message logs

17 | P a g e
User options
The options allow users to view storage system settings and change the user login password.
• Configure User login options
• Launch Command View EVA
• View network information
• View system information

Q10) What types of disk drives are supported in the M6612 or M6625 disk drive enclosure? (select two)

A. SSD
B. SATA
C. SAS
D. SAS Midline

Q11) Which statement is true regarding the M6612 disk drive enclosure?

A. It is supported on P6300 EVA storage systems


B. It is not RoHs compliant
C. It supports twelve 3.5 inch large form factor SAS drives
D. It features an all 4Gb copper Fiber Channels back end.

Q12) Which status LEDs are present on the front of the M6612 or M6625 disk drive enclosure? (select
two)

A. Disk Drive (front)


B. Power Supplies (rear)
C. I/O Modules (rear)
D. Enclosures (front)

Q13) How is power distributed through the rack and to the enclosures?

A. Rack: PDUs, Enclosures: PDMs


B. Rack: PDMs, Enclosures: PDUs
C. Rack: PDUs, Enclosures: disk drive enclosures
D. Rack: PDMs, Enclosures: disk drive enclosures

Q14) Which statement is true regarding HSV340 and HSV360 device and host connections?

A. Loop A cables to I/O module A


B. Loop A cables to I/O module B
C. Loop B cables to I/O module A

18 | P a g e
D. Loop A cables to either I/O module A or I/O module B

Q15) Which statement is true regarding P6000 EVA host cabling?

A. Cable with external Fibre Channel switches


B. Connect even controller ports to one fabric and odd controller ports to the other fabric
C. Connect odd and even controller ports to one fabric and odd and even controller ports to the
other fabric
D. When cabling for ABM, connect the Management Module to either switch

Explain: The front end of the P6300/P6500 EVA FC controllers can be connected either
to external Fibre Channel switches or directly to servers. The standard host port
connectivity rule is to connect even controller ports to one fabric and odd controller ports
to the other fabric.

Q16) Which statement is true regarding rack support for the EVA?

A. Field installation is supported with the 5642 rack


B. Field installation is supported with the HP 10000 G2 rack
C. The HP 10000 G2 36U must be assembled onsite
D. The HP 10000 G2 is not ROHS compliant

Q17) To browse to the web-based OCP on the Management Module, you must navigate to which url?

A. https://<IP_address>:2372**********************
B. https://<server_name>:2372
C. https://<IP_address>:2373
D. https://command_view_eva:2372

Q18) HP P6000 SmartStart is the startup utility that simplifies the installation and configuration of what
type of storage systems?

A. EVA4400 and P6000 EVAs


B. EVA 6400/8400
C. EVA 4100/6100/8100
D. All EVAs

Q19) To launch Command View from a browser, you must navigate to which urls? (select two)

A. https://<server_name>:2372 ************
B. https://Windows:2372
C. https://<IP_address>:2372 ************

19 | P a g e
D. https://command_view_eva:2372

Q20) Which statements are true regarding the licensing of EVA with Commnad View 7.0 and above?
(select two)

A. There is strict license enforcement for Command View, Business Copy, and Continuous Access
functionality
B. Licensing is only required for Business Copy and Continuous Access functionality
C. License keys are node-linked to an EVA by WWN and controller type
D. There is no license enforcement at all

Q21) Which subcommand allows you to add FCAs after the first FCA has been set?

A. Add host
B. Add vdisk
C. Set host
D. Set vdisk

Q22) What is the purpose of the SSSU?

A. Allows the management server to communicate with the controllers


B. Allows the issuing of text commands to manage the EVA (?????)
C. Allows scripts compiled for HSG controllers to be used
D. Allows fault reporting to a remote location

Q23) Which SSSU command interrogates the storage system and creates a script that you can use to re-
create the storage system?

A. Capture configuration
B. Capture host
C. Capture cell
D. Capture script

Q24) What can you view from the General Controller properties page?

A. Blower properties
B. Temperature Sensors
C. Power supply 1 and power supply 2 properties
D. XCS Revision Number

20 | P a g e
Q25) By default, the EVA configures a disk group in which kind of configuration?

A. Horizontal
B. Diagonal
C. Symmetrical
D. Vertical

Q26) Which term represents the creation of a separate virtual disk performed in the background?

A. Fully-Allocated Snapshot
B. Demand-Allocated Snapshot
C. Snapclone (????)
D. Business Continuous Volume

Q27) Which statement about snapshots and snapclones is correct?

A. You can create a snapshot and a snapclone from the same active virtual disk
B. You can delete a disk group if it has a virtual disk
C. An active virtual disk and its snapclone constitute a virtual disk family
D. Up to 16 snapshots of an active virtual disk can exist at any time (??????)

21 | P a g e
Q28) Which configuration task is required to set up the management server to operate with the EVA?

A. Restore the server


B. Zone the server
C. Configure static IP addresses
D. Set time

To install the entire software suite, your environment must include the following:
One or more arrays.
A management server running a supported version of Microsoft Windows (see the HP
P6000 Enterprise Virtual Array Compatibility Reference for supported versions).
Management server with dual-core 1.86 GHz processor or above.
4 GB memory.
More than 20 GB free space on the hard drive for the HP P6000 Performance Advisor
database.
If your server is a domain node, to install HP P6000 Command View, the logged-in user
must have read and execute permission at the OS drive and user-installation drive levels.
Adobe Flash Player plugin is required when using the browser to access HP P6000
Command View. (See Adobe Flash port configuration details at http://www.adobe.com;
search for configure ports for specific information.)
If using firewalls, take the ports in “TCP ports summary” (page 64) into consideration.
If using firewalls and if fixed ports are required in the MIF process, consult the HP
Management Integration Framework Administrator Guide to configure them.
If the time set on your system is not your local time, the installation may fail. Check the
time set on your system to ensure it is set for local time.

Q29) Which items in the superfile are loaded to an uninitialized EVA during an initial code load?

A. XCS and EMU firmware (?????)


B. XCS firmware, current parse file, and disk drive firmware
C. XCS firmware and the current parse file
D. XCS firmware, EMU firmware, and the current parse file
Retrieving the parse file
The parse file provides HP P6000 Command View with a human-readable description for each
event code generated by the array controllers. The parse file contains the hexadecimal event code
and event description, an explanation of the event, and the array component to which the event
refers. Every release of the controller software contains an updated parse file.
If the event description displays Description not found in parse file, you must update the parse
file that the controller uses to populate the event description. This can occur if you upgrade or
install HP P6000 Command View on a management server that has not previously run this
software.
Q30) The management server event logs have timestamps that are based on what component?

A. HSV controller (?????)

22 | P a g e
B. Local browser
C. Fibre channel switch
D. Management switch

Q31) Which event log allows you to filter events in Command View?

A. Windows application event log


B. Management server event log
C. Controller event log (????)
D. Controller termination event log

Controller events enhancements. Controller events can now be sorted, filtered and written to a
text-based log file.

Q32) What generates a termination event?

23 | P a g e
A. Fatal error that causes the storage system to stop operation
B. Procedure completion
C. Configuration change
D. No AC input for power supply

Controller termination event log


Controller termination events report that a controller has ceased operation, but do not report on
controllers in uninitialized arrays.

Management server event log


The management server is the server on which HP P6000 Command View is installed.
Management server events are triggered by:
- Responses to user actions in the user interface
- Actions initiated through the HP P6000 Command View application program
interface (API)

Controller event log


A controller event is a normal or exceptional action on any hardware component or
logical object within the array. Examples of controller events are:
- Disk or disk enclosure changes
- Configuration changes (such as creating a disk group)
- Controller reboots
- Changes detected by the environmental monitoring unit (EMU) within the array (does
not apply to the EVAx400 or P6000 models)
A normal event is informational and requires no action by you. An example of a normal
event would be the controller reporting that creation of a virtual disk has completed. An
example of an exceptional event would be a disk enclosure that has lost communication
on a Fibre Channel loop.

CAUTION: Uninitializing an array deletes all of the controller events cached in the
controllers.

Controller termination event log


Controller termination events report that a controller has ceased operation, but do not
report on controllers in uninitialized arrays.

24 | P a g e
Q33) Which event log seen from Command View is saved in ASCII format?

A. Management server event log


B. Controller event log (Binary)
C. Controller termination event log (Binary)
D. Windows application event log (from Windows and not from Command View)

To send the event file to HP Support:


1. Go to the appropriate event log:
In Management, click Event file.
In Controller Event, click Log file.
In Controller Termination Event, click Log file.
2. When prompted, save the file to your local hard drive.
3. Email the file to the support technician.

New) Which event log is NOT displayed using Command View?

A. Management server event log


B. Controller event log
C. Controller termination event log
D. Windows application event log

Q34) Which tool allows you to use the evaperf command for the EVA Performance Menu to build and
display a performance data collection?

A. EvaPerf
B. EVA Performance tool for Support
C. TLViz
D. Perfmon

Q35) Which Command View page is used for in depth diagnosis of storage system problems?

A. Services page
B. Administrator page
C. Field Service Options page
D. Capture System information page

For array-based management, click Capture System Information on the Server Options page to
capture the event logs and download them to the computer from which you are browsing.

25 | P a g e
Q36) In addition to timestamps, which indicator can be used to determine when events were logged in
an event log?

A. Sequence numbers
B. End dates
C. Date ranges
D. Start dates

The following information is provided for each controller event or controller termination event:
Date/Time—The date and time that the event occurred.
Severity—The severity types are informational, critical, warning, and undetermined.
Controller—Name of the controller on which the event occurred. The name and worldwide
ID of all controllers appears at the top of the event log.
Description—The text description of the event. For more information, see “Viewing additional
information” (page 58) and “Event code types and descriptions” (page 104).
Event Code—A hexadecimal number assigned to the event. For information about how the
hexadecimal number for the event code is formed, see “Event code format” (page 104).
Sequence #—The sequence number assigned to the event. Some tasks generate a series of
events. The sequence number helps you identify the order in which related events occurred.
The following information is provided for each management server event:
Date/Time—The date and time that the event occurred.
Severity—The severity types are informational, critical, warning, and undetermined.
Event Source—Name of the controller on which the event occurred. The name and worldwide
ID of all controllers appears at the top of the event log.
Description—The text description of the event. For more information, see “Viewing additional
information” (page 58) and “Event code types and descriptions” (page 104).
Notified?—Provides event notification status about the event.
Event Code—A hexadecimal number assigned to the event. For information about how the
hexadecimal number for the event code is formed, see

Q37) What is a best practice with respect to the number of disk groups in a storage system?

A. To optimize availability, place data and log files in the same disk group
B. To optimize performance, use multiple disk groups (?????)
C. To optimize cost, use only one disk group
D. Use a single disk group even for the most demanding availability situations

26 | P a g e
Q38) What are basic diagnostics used to troubleshoot the P6000 EVA series? (select two)

A. Command View audit log


B. Controller console port and boot menu
C. Controller WOCP
D. Field Service Options page

Setting audit logging options


With server-based management, use the Audit Logging Options feature to capture activities that
occur in the HP P6000 Command View user interface. A log file captures events generated by
these activities:
User login
User accessibility (for example, the Access Denied event is generated for users with view-only
access)
Actions that change the state of the array (for example, creating a virtual disk)
Actions that change the configuration of HP P6000 Command View (for example, changing
the page footer message)
You can have these events sent to one or both of the following logs and you can also specify a
directory on a remote server to store the log:
Audit log
Operating system application log
To set audit logging:
1. From the settings point of view session pane, click Management Options.
The Management Options window opens.
2. Under Security options, select Audit logging options.
The Audit logging options window opens.
3. Enable Log to a file.
4. Enter the log name and location in which to store the events, the size of the log, and the length
of time to retain the log.
See the HP P6000 Command View online help for detailed instructions.
5. Click Save changes.
Setting a remote location for audit logs
When you set the audit logging options, you can choose a file location on a local or remote server.
To use a location on a remote server, the remote server must be accessible to the management
server on which HP P6000 Command View is installed. If necessary, contact your network
administrator to establish the permissions required for the HP P6000 Command View server to
access the remote server.
After permissions are set, complete the following steps:
1. Open the Services window on the management server (where HP P6000 Command View is
installed).
2. Right-click the HP P6000 Command View service and select Stop.
3. Right-click the service again and select Properties.
The Properties window for the HP P6000 Command View service opens.
4. Select the Log On tab.
5. In the Log on as box, select This account and enter a valid user name and password for the

27 | P a g e
remote server.
6. Click OK, and then close the Properties window.
7. Right-click the service and select Start.

Q39) What are the controller boot diagnostics? (select two)

A. Get and set debug flags (??????)


B. DILX (??????) Disk InLine eXerciser (DILX)
C. BIST
D. MIST

Q40) What are advanced diagnostics used to troubleshoot the P6000 EVA series? (Select two.)

A. CVUTIL

B. Controller console port and boot menu

C. Controller WOCP

D. EMU console port

Answer: AC

28 | P a g e
HP HP2-K27 Exam - PassITexam.com

Free HP2-K27 Sample Questions:

Q: 1
What failover mode does the EVA currently use?
A. Active
B. Passive
C. Active-Passive
D. Transparent
Answer: C

Q: 2
In an EVA, what is purpose of virtual disk leveling?
A. Dynamically distribute data blocks over many physical spindles to eliminate
performance bottlenecks.
B. Equalize disk capacity.
C. Allocate space per disk group to recover from physical disk group member failure.
D. Build virtual disks from physical disks.
Answer: C

Q: 3
What is the approximate maximum virtual disk size for a disk group with 10 36GB
drives and a disk protection level of Single?
A. 134 GB
B. 202 GB
C. 270 GB
D. 338 GB
Answer: C

Q: 4
What is an initialized pair of HSV controllers with a minimum of six or eight physical
drives?
A. Storage system
B. Pstore
C. Redundant storage set (6 to 11 disks)
D. Rstore
Answer: A

29 | P a g e
Free Download Latest 2014 Pass4sure&Lead2pass HP HP2-K27 Exam
Questions
By admin | August 6, 2014

0 Comment

Vendor: HP
Exam Code: HP2-K27
Exam Name: Supporting and Servicing HP P6000 EVA Solutions

QUESTION 1
Which statement is true regarding rack support for the EVA?

A.    Field installation is supported with the 5642 rack


B.    Field installation is supported with the HP 10000 G2 rack.
C.    The HP 10000 G2 36U must be assembled onsite.
D.    The HP 10000 G2 is not ROHS compliant.

Answer: A
Explanation:
http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c01883144/c01883144.pdf
(page 21)

QUESTION 2
What is the maximum number of EVA storage systems that you can manage from a single
instance of Command View?

A.    1
B.    8
C.    16 (maximum number of disk groups)
D.    32

Answer: C (up to 16 EVA)


Explanation:
http://h18000.www1.hp.com/products/quickspecs/13905_na/13905_na.HTML (topic: product
highlights/benefits)

30 | P a g e
Question

How many SAS lanes are available on a P6500 EVA storage system?

A. 6

B. 8

C. 12

D. 16

QUESTION 3
To launch Command View from a browser, you must navigate to which urls? (Select two.)

A.    Error! Hyperlink reference not valid.>


B.    https://Windows:2372> (2373)
C.    Error! Hyperlink reference not valid.>
D.    https://command_view_eva:2372>

Browse to https://192.168.0.1:2373 (IPv4) or https://fd50:f2eb:a8a::7/48


(IPv6) and log in as a storage administrator. The default user name is admin. No password is required
during the initial setup. The HP P6000 Control Panel GUI appears.

Accessing a Control Panel


Every HP P6000 EVA storage system with array-based management includes Control Panel
functionality. To access the Control Panel for a given HP P6000 EVA storage system, you must
know the IP address of the system. Procedure:
1. Open a browser.
2. Browse to https://HP P6000 EVA storage system IP address:2373. The HP P6000 Control
Panel login window appears.
Example: https://21.44.63.101:2373
3. Log in as a storage user or storage administrator. (User name user or admin and password.

QUESTION 4
What is a best practice with respect to the number of disk groups in a storage system?

A.    To optimize availability, place data and log files in the same disk group.
B.    To optimize performance, use multiple disk groups.
C.    To optimize cost, use only one disk group.
D.    Use a single disk group even for the most demanding availability situations.

31 | P a g e
Availability best practice: Do not mix disk sizes in a single disk group.

Availability best practice: Always configure spare space for every array group. Do not rely
on unassigned capacity to support the recovery of a failed drive.

Availability best practice: For critical database applications, place data and log files in
separate disk groups.

QUESTION 5
Which Command View page is used for in depth diagnosis of storage system problems?

A.    Services page


B.    Administrator page
C.    Field Service Options page
D.    Capture System Information page

Answer: D

32 | P a g e
QUESTION 6
What are the controller boot diagnostics? (Select two.)

A.    Get and set debug flags


B.    DILX
C.    BIST
D.    MIST

Answer: AB

QUESTION 7
What are advanced diagnostics used to troubleshoot the P6000 EVA series? (Select two.)

A.    CVUTIL
B.    Controller console port and boot menu
C.    Controller WOCP
D.    EMU console port

Answer: AC

If you want to pass HP HP2-K27 successfully, donot missing to read latest lead2pass HP HP2-
K27 practice tests.
If you can master all lead2pass questions you will able to pass 100% guaranteed.

Question :
Which statement is true regarding rack support for the EVA?

A. Field installation is supported with the 5642 rack


B. Field installation is supported with the HP 10000 G2 rack.
C. The HP 10000 G2 36U must be assembled onsite.
D. The HP 10000 G2 is not ROHS compliant.

Answer : A

33 | P a g e
Question :
Which statements are true regarding the M6612 and M6625 drive enclosure I/O modules?
(Select two.)

A. A and B I/O modules are physically different.


B. A and B I/O modules are identified by slot pin.
C. Each module contains an Enclosure Management Processor (EMP) and a20-port cut
through switch (CTS).
D. The modules communicate through the EAB.

Answer : C (???????)

Management of up to 1023 virtual disks (256 per HBA) for the P6300
EVA and up to 2047 virtual disks for the P6500 EVA, with LUNs
ranging in size from 1GB to 32TB per Virtual disk, in 1GB increments

Drive description 250 SFF SAS or 120 LFF SAS for the P6300, 450 SFF
SAS or 240 LFF SAS for the P6500
Maximum, or combinations of both SFF or LFF

34 | P a g e
HP2-K27 – 40 Questions: (from: http://free-online-exams.com/Pages/Exams/DumpsQA.aspx?
d=hp&c=HP2-K27&q=1)

1) What failover mode does the EVA currently use?


A. Active
B. Passive
C. Active-Passive
D. Transparent 

Ans.: C (????)

2) In an EVA, what is purpose of virtual disk leveling?


A. Dynamically distribute data blocks over many physical spindles to eliminate performance
bottlenecks.
B. Equalize disk capacity.
C. Allocate space per disk group to recover from physical disk group member failure.
D. Build virtual disks from physical disks. 

Ans.: A (MKAD)

3) What is the approximate maximum virtual disk size for a disk group with 10 36GB drives and a
disk protection level of Single?
A. 134 GB
B. 202 GB
C. 270 GB
D. 338 GB 

Ans.: C (MKAD)

4) What is an initialized pair of HSV controllers with a minimum of six or eight physical drives?
A. Storage system
B. Pstore
C. Redundant storage set
D. Rstore 

Ans.: C (MKAD)

35 | P a g e
5) What is the maximum number of disk groups supported for any EVA?
A. 8
B. 16
C. 32
D. 64 

Ans.: B (MKAD)

6) What is the cache size of each HSV360 controller in a P6500 EVA?


A. 1 GB
B. 2 GB
C. 4 GB
D. 8 GB 

Ans.: D (MKAD)

36 | P a g e
7) On the web-based OCP, what level of user functionality allows you to set the storage system''s
networking, security, and system time characteristics?
A. Global
B. User
C. Administrative
D. Service 

Enok Hauge Says : C

8) How many SAS lanes are available on a P6500 EVA storage system?
A. 6
B. 8
C. 12
D. 16  (MKAD)

Ans. D

The P6300 EVA utilizes eight redundant 6 Gb SAS lanes and the P6500 EVA utilizes sixteen
redundant 6 Gb SAS lanes from each controller to each SAS drive enclosure for redundant
paths to dual drive lanes.

37 | P a g e
9) Which type of management does the Management Module allow?
A. array-based management
B. server-based management
C. array-based and server-based management
D. remote server-based management 

Ans. A (MKAD)

10) Which statements are true regarding the M6612 and M6625 drive enclosure I/O modules?
(Select
two.)
A. A and B I/O modules are physically different.
B. A and B I/O modules are identified by slot pin.
C. Each module contains an Enclosure Management Processor (EMP) and a20-port cut through
switch (CTS).
D. The modules communicate through the EAB. 

Ans. C

11) What is the maximum number of M6612 large form factor and small form factor disk drives
supported for the P6300 EVA storage systems?
A. 80, 120
B. 120, 120
C. 120, 240
D. 120, 250 (MKAD)

Ans. D

Drive description 250 SFF SAS or 120 LFF SAS for the P6300, 450 SFF SAS or 240
LFF SAS for the P6500
Maximum, or combinations of both SFF or LFF

38 | P a g e
12) Which components are customer self repair units of the M6612 or M6625 disk drive enclosure?
(Select two.)
A. EMU
B. Power Supply
C. I/O Module
D. Battery 

Enok Hauge Says : B,D (and MKAD)

Customer self repair (CSR) components are noted where applicable below

   – Cache battery (CSR)


   – Controller blower (CSR)
   – Controller power supply (CSR)
  – Drive enclosure power supply (CSR)
  – Drive enclosure blower (CSR)
  – Disk drive (CSR)

13) Which component is an HSV360 customer-replaceable unit?

A. I/O Module

B. Fan Module Interconnect Board

C. Backplane

D. Management Module

Controller Enclosure Customer Replaceable parts or self-repair:

Array battery
Array power supply
Array fan module
Array management module
P6300 bezel assembly

Disk enclosure replaceable parts

Disk Drives

Power Supply

Fan Module

39 | P a g e
14) What power protection is used on the PDMs in an EVA rack?
A. circuit breaker
B. trip breaker
C. 16A fuse
D. AC receptacle 

Ans.: A (MKAD)

15) What are the primary power distribution components in the EVA rack?
A. cables and junction boxes
B. one EAB and six junction boxes
C. one dual PDU and four PDMs
D. one dual PDU and several PDMs 

Ans.: C (MKAD)

The standard power configuration for any Enterprise Virtual Array rack is the fully redundant
configuration. Implementing this configuration requires:
◦ Two separate circuit breaker-protected, 30-A site power sources with a compatible wall
receptacle.
◦ One dual PDU assembly. Each PDU connects to a different wall receptacle.
◦ Four to eight (depending on the rack) Power Distribution Modules (PDM) per rack. PDMs are
split evenly on both sides of the rack. Each set of PDMs connects to a different PDU.
– Eight PDMs for 42U, 47U, and 42U 5642 racks
– Six PDMs for 36U racks
– Four PDMs for 22U racks
◦ The drive enclosure power supplies on the left (PS 1) connect to the PDMs on the left with a
gray, 66 cm (26 inch) power cord.
◦ The drive enclosure power supplies on the right (PS 2) connect to the PDMs on the right with a
black, 66 cm (26 inch) power cord.
◦ Each controller has a left and right power supply. The left power supplies of each should be
connected to the left PDMs and the right power supplies should be connected to the right PDMs.

40 | P a g e
16) How many PDMs are installed in an EVA rack?
A. 2
B. 4
C. 6
D. 4 to 8

17) How many PDMs are installed in an EVA rack?


A. 2
B. 4
C. 6
D. 4 to 8 

Ans.: D (see previous Q)

18) Which statement is true regarding rack support for the EVA?
A. Field installation is supported with the 5642 rack
B. Field installation is supported with the HP 10000 G2 rack.
C. The HP 10000 G2 36U must be assembled onsite.
D. The HP 10000 G2 is not ROHS compliant. 

Ans. A

41 | P a g e
19) What is the maximum number of EVA storage systems that you can manage from a single
instance of Command View?
A. 1
B. 8
C. 16
D. 32 

Ans. C (MKAD)

20) To launch Command View from a browser, you must navigate to which urls? (Select two.)
A. https://<server_name>:2372>
B. https://Windows:2372>
C. https://<IP_address>:2372>
D. https://command_view_eva:2372> 

Enok says: A,C

21) For a P6000 series EVA, you have the choice of loading Command View on what two
components? (Select two.)
A. HSV340 or HSV360 controller
B. Management Module
C. Management Switch
D. Management Server 

Ans. (B,D: MKAD)

22) Which statements are true regarding the licensing of EVA with Command View 7.0 and above?
(Select two.)
A. There is strict license enforcement for Command View, Business Copy, andContinuous Access
functionality.
B. Licensing is only required for Business Copy and Continuous Access functionality.
C. License keys are node-linked to an EVA by WWN and controller type.
D. There is no license enforcement at all. 

Ans. C (MKAD)

42 | P a g e
23) What does the select manager subcommand do?

A. Directs the command prompt to the selected storage system.


B. Directs the command prompt to the selected controller.
C. Directs the command prompt to Command View.
D. Directs the command prompt to the selected host.

SELECT MANAGER
The SELECT MANAGER command configures SSSU for use on the specified HP Command View EVA
instance. The manager name can be a management server name or an IP address. The user name
and password are the account credentials that were created for you during HP Command View EVA
installation. The user name and password are validated in the background on every command.
NOTE:
The SELECT MANAGER command is available for use in batch scripts only. When the command is
run from a script, the command does not display on screen nor is it redirected to a file.
When HP Storage Scripting Utility is connected to an HP Command View EVA server in interactive
mode, the SELECT MANAGER command can be issued again to connect to another HP Command
View EVA server. The SELECT MANAGER command prompts for hostname, username, and password;
however, the password is optional.
Syntax
SELECT MANAGER manager_name USERNAME=user_name|domain_name\user_name
SELECT SYSTEM
The SELECT SYSTEM command directs the command prompt to the selected array. All configuration
commands affect the selected array. If the system name includes spaces, enclose it in quotes.
Syntax
SELECT SYSTEM array_name
Examples
Select the employees array:
SELECT SYSTEM employees
Select the payroll storage array:
SELECT SYSTEM "payroll storage"

24) What is the purpose of the capture configuration command?

A. Recreates the configuration of a storage system.


B. Restores customer data in a configuration.
C. Recreates a configuration and restores customer data.
D. Captures all SSSU script files ever created for the storage system

21) What failover mode does the EVA currently use?


A. Active
B. Passive
C. Active-Passive
D. Transparent

Answer: C
43 | P a g e
Reference: http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA2-
8848ENW.pdf
(page 10, figure 4)

25) In an EVA, what is purpose of virtual disk leveling?


A. Dynamically distribute data blocks over many physical spindles to
eliminate performance bottlenecks.
B. Equalize disk capacity.
C. Allocate space per disk group to recover from physical disk group
member failure.
D. Build virtual disks from physical disks.

Answer: C

Reference: http://www2.openvms.org/kparris/eva_intro.ppt

26) What is the approximate maximum virtual disk size for a disk
group with 10 36GB drives and a disk protection level of Single?
A. 134 GB
B. 202 GB
C. 270 GB
D. 338 GB

Answer: C
Explanation:
To find out the maximum virtual disk size, you have to multiply 10 by
36. That makes 360 GB.
Now you have to calculate the spare allocation. Normally space
allocation is calculated by dividing 36 GB by 4. The result will be 90
GB. Now minus 90 GB from 360 and you will get 270 GB as the
maximum virtual disk size for a disk group.

27) What is an initialized pair of HSV controller s with a minimum of


six or eight physical drives?
44 | P a g e
A. Storage system
B. Pstore
C. Redundant storage set
D. Rstore

Answer: C

24) What is the maximum number of disk groups supported for any EVA?
A. 8
B. 16
C. 32
D. 64

Answer: B

25) What is the cache size of each HSV360 controller in a P6500 EVA?
A.1 GB
B. 2 GB
C. 4 GB
D. 8 GB

Answer: D

45 | P a g e
26) On the web-based OCP, what level of user functionality allows you to set
the storage system’s networking, security, and system time characteristics?
A. Global
B. User
C. Administrative
D. Service

Answer:C

27) How many SAS lanes are available on a P6500 EVA storage system?
A. 6
B. 8
C. 12
D. 16

Answer: D

28) Which type of management does the Management Module allow?


A. array-based management
B. server-based management
C. array-based and server-based management
D. remote server-based management

Answer: A

46 | P a g e
29) Which statements are true regarding the M6612 and M6625 drive
enclosure I/O modules? (Select two.)
A. A and B I/O modules are physically different.
B. A and B I/O modules are identified by slot pin.
C. Each module contains an Enclosure Management Processor (EMP)
and a20-port cut through switch (CTS).
D. The modules communicate through the EAB.

Answer: C (?????)

30) What is the maximum number of M6612 large form factor and small
form factor disk drives supported for the P6300 EVA storage systems?
A. 80, 120
B. 120, 120
C. 120, 240
D. 120, 250

Answer: D

47 | P a g e
1. Which methods are available to provide system administrators direct notification of Field
Replaceable Unit (FRU) failures? Select TWO.

A. e-mail

B. RPC traps

C. SCMI traps

D. SNMP traps

E. syslog event

Answer: AD

2. A blower has failed on a disk enclosure on an EVA4000. Which actions should be taken to repair
the condition?

A. Order replacement blower. Replace the failed blower when the replacement blower arrives on
site.

B. Remove the failed blower immediately. Order a replacement blower and install the replacement
blower once it arrives on site.

C. Order the replacement blower. Shut the disk enclosure down when the replacement blower
arrives on site and install the replacement blower.

D. Order the replacement blower. Remove the failed blower when the replacement blower arrives
on site. Wait 30 minutes to ensure the removal is detected by the EMU and then install the
replacement blower.

Answer: A

3. How many FC switched fabric connections are there on each M5314A drive enclosure?

A. 0

B. 2

C. 4

D. 8

Answer: A

48 | P a g e
4. When connecting a 0C12D expansion rack to a 2C12D EVA8000 configuration, how many disk
enclosures can be connected from the expansion rack to the EVA8000?

A. 4

B. 6

C. 8

D. 12

Answer: B

5. What is the minimal version of Command View EVA supported with the EVA6000 XCS version 5.0
controller software?

A. 3.0a

B. 3.2

C. 4.0

D. 6.0

Answer: C

6. When does the EVA use unassigned capacity within a disk group? Select TWO.

A. for data reconstruction after a disk failure

B. during new disk group creation for data replication

C. for new virtual disk creation, snapshots, and snapclones

D. during new virtual host creation for active-active configurations

Answer: AC

7. You are using the SSSU to regenerate a previous non-Continuous Access configuration saved in a
file named config1.txt.

Which command do you use?

49 | P a g e
A. run c:\\config1.txt

B. file c:\\config1.txt

C. restore c:\\config1.txt

D. recreate c:\\config1.txt

Answer: B

8. What is the key customer benefit of the EVA solution?

A. virtualization

B. 100% availability

C. isolated capacity

D. DAS to SAN architecture

Answer: A

9. What does the EVA provide in a heterogeneous environment? Select TWO.

A. mainframe support

B. no single point of failure

C. reliable and infinitely scalable

D. modular and scalable storage

E. preconfigured operating system solutions

Answer: BD

10. Which statement is true about Distributed Virtual RAID (DVR)?

A. The location of each chunk of data changes dynamically.

B. Physical blocks of data are more easily located in a DVR system than in traditional RAID.

C. The logical blocks for the virtual disk are directly mapped to the physical blocks of the hard drive.

50 | P a g e
D. The storage administrator has full control over the distribution of physical data chunks on the
storage array.

Answer: A

11. Using Command View EVA, which attributes are displayed for HSV2x0 Controller Properties.
Select THREE.

A. mirror port states

B. temperature sensors

C. UPS voltage indicators

D. cache battery module states

E. levels of protection from shelf failures

Answer: ABD

13. What are two capabilities of the HP Command View EVAPerf? Select TWO.

A. review port status

B. creation of vdisks

C. display SAN topology

D. collect host connection data

E. review capacity planning data

Answer: AD

14. HP StorageWorks XCS manages all aspects of the EVA storage system operation. XCS provides
scalable capacity on-demand and which other functionality? Select TWO.

A. provides Advanced Data Guarding

B. increases disk utilization efficiency

C. provides easy dynamic storage expansion

D. provides easy management of the FC Switch and HBA

Answer: BC

51 | P a g e
15. A customer requires a six hour call-to-repair commitment. Which minimum type of HP Care Pack
Service is appropriate?

A. HP Support Plus

B. HP Critical Service

C. HP 4 Hour, 24x7 Hardware Support

D. HP Proactive Essentials 24x7 Unlimited

Answer: B

16. Which warranty and services are included with the EVA6000 product?

A. 3-year hardware support, with 4-hour response on a 24x7 basis and 1-year, 24x7 XCS phone-in
support and updates

B. array installation and startup service, 2-year hardware support, with 4-hour response on a 24x7
basis and 2-year, 24x7 XCS phone-in support and updates

C. array installation and startup service, 2-year hardware support, with 4-hour response on a 24x7
basis and 3-year, 24x7 XCS phone-in support and updates

D. array installation and startup service, 3-year hardware support, with 4-hour response on a 24x7
basis and 1-year, 24x7 XCS phone-in support and updates

Answer: B

17. What does the storage system password protect?

A. access to Command View EVA

B. access to the operator control panel

C. login to the management server

D. access from the management server to the storage system

Answer: D

52 | P a g e
18. Which statement about changing the storage system password for an EVA is correct?

A. If you change the password with the controller OCP, the change is propagated to Command View
EVA.

B. If you change the password in the controller OCP, the password must also be changed in
Command View EVA.

C. If you do not know the password that was entered with the controller OCP, you have to
reinitialize the storage system.

D. If you want to change an established password to a new one, it is sufficient to use "Change a
storage system password" in Command View EVA.

Answer: B

19. How can the status of a specific EVA controller cache battery be checked?

A. by running controller diagnostics

B. from the controller's UART port

C. from Controller Properties in Command View EVA

D. by checking the battery status LED on the back panel of the controller

Answer: C

20. What is the first step required in creating a preallocated snapclone on an EVA8000?

A. create Vdisk

B. create a LUN

C. create the container

D. clear the write cache

E. add a new FC disk drive

Answer: C

53 | P a g e
21. When using Instant Support Enterprise Edition (ISEE), which method is used to transport error
information to HP?

A. Internet

B. SNMP traps

C. Exchange Mail

D. secure dial up line

E. standard modem interface with encryption

Answer: A

22. Why would you consider configuring two separate disk groups instead of a single one? Select
TWO.

A. higher availability

B. lower cost of ownership

C. higher storage efficiency

D. better database performance

E. better utilization of disk space

Answer: AD

23. Which Vraid level provides the highest availability?

A. 0

B. 1

C. 3

D. 5

Answer: B

24. Which statement is true regarding an EVA solution with a mixture of 10,000 rpm and 15,000 rpm
disks?

54 | P a g e
A. all disks must be the same capacity

B. only Vraid0 and Vraid5 levels are supported

C. 15,000 rpm disks will slow down to 10,000 rpm performance

D. 10,000 rpm and 15,000 rpm disks can reside in the same disk group

Answer: D

25. Which disks are used to optimize price per capacity for your EVA storage subsystem? Select
TWO.

A. higher performance disks

B. near online disks

C. larger capacity disks

D. smaller capacity disks

Answer: BC

26. Why would you configure multiple disk groups instead of a single disk group?

A. to use different Vraid levels

B. to achieve higher data availability

C. to lower the total cost of ownership

D. to support larger disk volumes spanned across disk groups

Answer: B

27. What is the best practice when adding disks to an EVA 2C8D for a Robust Availability
Configuration?

A. After adding the disks, delete and recreate the disk group.

B. Add disks in multiples of eight; distributed evenly across the shelves.

C. Install any number of disks and assign each of them individually to the appropriate redundant
storage set.

55 | P a g e
D. After installing a single disk, wait until leveling has taken place in the existing disk group before
you install the next disk.

Answer: B

28. What does the Storage System Scripting Utility (SSSU) command capture configuration create?

A. one to five SSSU scripts that enable it to recreate the original configuration including snapshots

B. one to five SSSU scripts that enable it to recreate the original configuration except for snapshots

C. a topology map and an ASCII file that summarizes the current storage system configuration

D. one to five text files that must be converted, linked, and validated with the command capture
validate in order to use them as recovery scripts

Answer: B

56 | P a g e
Learning Check Answers

Product Overview learning check


1. What are five EVA features?
List five of the following: Fibre Channel technology, no single point of failure, cluster
server and high availability support, virtualization, multiple operating system support,
dynamic virtual disk expansion, Business Copy functions, Continuous Access functions,
multi-server shared support, single pathing support, end-to-end high availability and fault
tolerance, including controllers, drive enclosures, disk drives, and power distribution.
2. How much presentable (virtualized) capacity is available for an EVA6100?
112 TB.
3. How much presentable (virtualized) capacity is available for P6500 EVA?
800 TB.
4. What are the primary physical components of the EVA solution?
Hosts, fabric switches, management server, HSV controllers, disk drive enclosures, disk
drives, Fibre Channel loop switches, rack.
5. What are three EVA models and the base configurations for each?
List three of the following: P6300 EVA (2C1D), P6500 EVA (2C2D), EVA4400 (2C1D),
EVA6400 (2C2D), EVA8400 (2C3D), EVA4100 (2C1D), EVA6100 (2C4D), EVA8100
(2C2D, 2C6D, 2C12D), EVA4000 (2C1D), EVA6000 (2C4D), EVA8000 (2C2D, 2C6D,
2C12D), EVA3000 (2C1D), EVA5000 (2C2D, 2C6D, 2C12D).
6. How many loop pairs are available through the EVA8400?
Three.
7. How many host and device ports are there on a single HSV1x0, HSV2x0, HSV300, or
HSV4x0 controller?
The HSV100 has 2 host and 2 device ports, and the HSV110 has 2 host and 4 device
ports.
The HSV200 has 2 host and 2 device ports, and the HSV210 has 4 host and 4 device
ports.
The HSV300 has 2 host and 2 device ports, and the HSV300-S has 2 host and 2 device
ports, with the host ports connected through the embedded 10-port switch.
The HSV400 has 4 host and 4 device ports, and the HSV450 has 4 host and 6 device
ports.

57 | P a g e
8. How many host ports are available on an HSV340/HSV360 controller pair?
Eight.
9. How many SAS lanes are available on a P6300 EVA storage sytem?
Eight.
10. How many loop switches are available for the EVA6400?
None.
11. How many controller enclosures are present on the EVA4400 or P6000 EVAs?
One.
12. What is the name of the rack used for all EVA storage systems?
HP 10000 G2 series.
13. What is the maximum storage capacity of one EVA8100 storage system with 1 TB FATA
disks?
240 TB for a 2C18D.
14. What is the maximum storage capacity of one P6500 storage system with 2 TB LFF SAS
disks?
480 TB for a 2C20D.
15. What are the operating systems supported on the EVA 4400/6400/8400 series?
MS Windows, Sun Solaris, HP-UX, IBM AIX, HP OpenVMS, Red Hat Linux and SUSE
Linux, Novell NetWare, VMware, Apple Mac OS X, Citrix, Xen.
16. What is the function of the management server?
Used as the hardware interface to the array and contains Command View EVA, which is
used to manage and configure the storage system.
17. What unique EVA4400 or P6000 EVA component allows array-based management of the
array?
Management Module.
18. What tools are used for remote error notification?
RSP and WEBES-SEA.
19. What is the maximum storage capacity for the EVA4400 with 1 TB FATA disks?
The maximum storage capacity for the EVA4400 is 96 TB for a 2C8D when using the 1
TB FATA disks.

58 | P a g e
20. What is the maximum storage capacity of one EVA8400 storage system with 1 TB FATA
disks?
324.0 TB for a 2C27D.
21. What is the maximum storage capacity of one P6300 EVA storage system with 500 GB
SFF SAS disks?
125 TB
22. What tool is used to configure EVA4400 or P6000 EVA hardware properties, such as
configuring the connectivity?
Web-based Operator Control Panel (WOCP).
23. What controllers are used with the EVA4400 and give two unique features?
HSV300 and HSV300-S are the controllers for the EVA4400. Two unique features are
that it lacks a physical OCP and two controllers are present in the same enclosure. The
HSV300-S has an embedded 10-port SAN switch.
24. What controllers are used with the P6000 EVA?
HSV340 and HSV360
25. How much controller cache is available with the EVA8400 storage system?
Either 14 GB (low cache model) or 22 GB (high cache model).
26. How much controller cache is available with the P6500 EVA storage system?
8 GB
27. What is the disk enclosure used with the EVA 4400/6400/8400 series and give two unique
features?
M6412x is the disk drive enclosure used with the EVA4400. Unique about it is the
support for Fibre Channel, FATA, or SSD drives (not supported earlier), and lack of a
cabinet bus or CAN/EAB.
28. What are the disk enclosures used with P6000 EVA series and what is the maximum
number of drives and type (form factor) that each enclosure supports?
M6612 supports 12 LFF, M6625 supports 25 SFF
29. What is the range of solid state disk (SSD) drives that are supported in an EVA
4400/6400/8400 series array?
From 6 to 8 SSDs are supported.
30. What are the capacities and speeds of LFF SAS drives that are supported in P6000 EVA
series?
300 GB, 450 GB, and 600 GB 15K rpm, 2 TB 7.2K rpm midline

59 | P a g e
31. How is the EMU functionality handled in the EVA 4400/6400/8400 or P6000 EVA series?
The physical EMU is not present in the EVA4400 and the EMU functionality is handled
by the I/O module.
32. What is the name of the startup configuration utility used for the EVA4400 or P6000
EVA?
P6000 SmartStart.
33. What are four functions that P6000 SmartStart provides?
List the following: Command View installation, HBA setup and system drivers,
Multipath installation, and presentation of virtual disks and configuration of the host for
the same.
34. What environmental norms does the EVA 4100/6100/8100 series comply with?
RoHS and WEEE.
35. How is licensing enforced in P6000 Command View?
The licensing is managed through a software license management tool called Autopass.

60 | P a g e