Datacenter Overview

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 35

Presented by

Chan Nyein
Why Data
Center is
important ?
• Foundation of Any
Business

• Cost of Downtime
Natural Origin Human Origin
 Fire  Equipment Failure
 Heat  Human Errors
 Cold  Sabotage
 Water Flooding  Terrorism
 Lightning  Network Saturation
 Earthquake  Virus Hackers
 Air Pollution
 Electro Magnetic Fields
 Power Failure
Mission Critical Sites Selection
Potential Natural Hazards
Mission Critical Sites Selection
Potential Natural Hazards
Site Selection for Building
 Rent / Buy
 History of Building
( eg. Flood , fire , etc )
 Level / Floor within building
 Floor Loading
 Slab to slab Height
 Power Redundancy
 External Power ( eg. Generator )
Data Center Facilities
Environmental Racks & PDU Fire suppression System
Monitoing

Monitoring Room UPS

CRAC CCTV

Electrical Distribution

Door Access

Water Leakage
Site Selection Area
• Easy access for external supply
• Spacious
• Secure
Site Selection Area
• If need, Construct foundation frame to protect the vibration
because of earthquakes, and other damage such as railway
and flight.
Raised Floor Standards
• BS/EN 12825
• UK-PSA
• US-CISCA (Ceiling Interior Systems Constructors Association)
• NFPA 251 , Fire Resistant for at least 1 Hour
• IEC-61000-4-2, Anti-static Properties
Uniformally Distributed Load Rolling Load

Point Load
Raised Floor Usage

Preferred 2 feet Ratio = 1:12


Light
 Lumen ( Lm ) : Light Strength
 Lux ( Lx ) : Light Strength in area
 Theory
Lx = Lu/𝑚2
 Lighting should be located above
aisles and between cabinets
according to TIA-942-A.
 In Data Center, It also needs
500 lux.
Light Placement
• Back of the Light are more important than the front of the rack
• Fluorescent lights should never be connected to UPS
Power Infrastructure
 Power distribution should be
-Reliable
-Scalable
-Flexible

Overhead Under Raised Floor


Power Cable Distribution

Trunking Tray

Ladder Basket
Power Distribution
UPS (Uninterruptible Power Supply)
➢ According to the EN50091-3/IEC62040-3, Online Double
Conversion (VFI class) is good for mission critical data center
Principle of UPS
Redundancy Power Supply
Main Batteries for UPS
❖ Flooded Cell
- above 500kVA
- Long Life (15-20 Years)
- Operate at high current

❖ Sealed Lead Acid ( SLA / VRLA )


- 5 / 10 year design
- attractive price
- slow discharge

❖ Nickel-Cadmium ( Ni-Cd )
- long life ( 20 years )
- fast charging
- very expensive
Data Center Cooling
❑Cooling is the most important factors for data center

Vibration Electronic Component Failure


20% Dust
6%

Temperature
Humidity
Vibration
Dust

Humidity Temperature
19% 55%
Basic Principle of Cooling
Cooling system with split type
❑ Less effectiveness
❑ Need return hot air exhaust pipe
❑ Easy to maintain
Cooling system with CRAC
❑ Good Efficiency
❑ More expensive
❑ Precision Airflow
Containment Cooling Solution
Cold Aisle Solution Hot Aisle Solution

❖ Less expensive ❖ Open area of room is cold environment


❖ Need cap at the top ❖ Need return air plenum
❖ More space require ❖ More effective
❖ Easy to implement ❖ Easy to implement
Air Booster
❑ Speed up the air flow to the desired direction
❑ More efficiency
❑ More Expensive
Cooling Theory
 1 Ton = 12,000 BTU
 1 Ton =3.516 kW
 1 Ton = 4.714 Hp
 1 Hp = 745.6 Watt (Electrical)
 1 BTU = 0.0003929 Hp
 1 BTU = 0.25 Kcal
 1 Hp = 2.64 kW (Cooling)
Structured Cabling System
Structured Cabling
Overhead Cabling Underfloor Cabling
❖ Cost Saving ❖ More Expensive
❖ Design for Less Space Room ❖ Leakage 25% of airflow through cable
❖ Need More Cable Length cutout
depending on the height of trays ❖ Design for large Space Room
❖ Effect with hot return air ❖ Need more raised floor height
Cabling Characteristics
 TIA/EIA 568 Standard ➢ TIA/EIA 568 Standard
 Rigid ➢ Flexible
 Less interference ➢ More interference
 Length maximum 100 meters ➢ Length maximum 10 meters
➢ Best used for structured
 Best used for structured cabling
cabling
Working Principles of Fiber Cable

 Light is emitted as pulses by


laser / led
 Travel through the fiber
bouncing off endlessly
 Receive the light & Convert to
Data
 Allows Faster Speed
 Can travel Longer Distance
Fiber Cable
Single Mode Multi Mode
 9 µm Core  50 or 62.5 µm Core
 Higher Bandwidth & Lower  Lower Bandwidth & Higher
attenuation attenuation
 Laser Light Source  Led Light Source
 Longer Distance (several km)  Medium Distance (300 meters)
 SC, LC, FC or ST Connectors  SC, LC, FC or ST Connectors
 Used in Telecom & CATV Networks  Used in LAN and Security System
Connector Types

 Better Connectors lose very


little light
 SC & LC are most useful
 Mostly used in telecom
Devices and Datacenter