Professional Documents
Culture Documents
tsm-1 e 201612
tsm-1 e 201612
Motion Seismometer
General
The TSM-1 Velocity Type Strong-Motion
TSM - 1
Seismometer incorporates three built-in seismic
sensors including two for horizontal direction and
one for vertical direction. The TSM-1’ s wide
frequency and dynamic range capability can
handle the full spectrum of seismic disturbances,
from microtremors to large earthquakes.
The Seismometer’ s highly sensitive, all-purpose
enclosed triaxial design provides superior mobility,
which makes it easy to set up at temporary
observation stations.
Applications
●
Strong earthquake and aftershock observation
●
Earthquake measurement, monitoring, alarm
Sensor unit
warnings
●
Monitoring of structural sway caused by Frequency Response
long-period ground motion 20 dB
●
Volcano observation
0 dB
Features
Gain[dB]
−20 dB
1) Triaxial design simplifies installation.
2) Force balance torquer arrangement requires no on-site −40 dB
adjustment.
−60 dB
processing. 0 deg
Measurement Range
NS 300 kine
308
Horizontal
300
Component
30 kine
EW
3 kine
300m kine
Velocity
30m kine
3m kine
23
UD
161
30μ kine
3μ kine Microseism
120
246
29
10
Specifications
Composition Horizontal direction, 2 + Vertical direction, 1
Output signal Velocity(Temperature range 25℃±15℃ stable temperature) Acceleration(reference)
Measurement range ±3 m/S(±300kine) [see Note 1] ±20 m/S(±2000gal)
2
40×10−6 m/S/℃ or less[4×10−3 kine/℃] (Design value) ±1.5×10−3 m/S2/℃ or less[150×10−3 gal/℃]
Bias temperature coefficient
Typ.4×10 m/S/℃[0.4×10 kine/℃]
−6 −3
Composition 20
Options
⑤ AC100V
0 No. Name Model No. Description
⑤ Power cable ⑥ External TSM-1-T Available options
③ Sensor cable
−20 diagnostics *Test signal generation
② Signal distributor
① Sensor unit equipment *Integrated response check
−40 ⑦ Diagnostics cable *External signal input
*Electric power from
−60 ⑥ External ④ External signal distributer
0.001 0.01 0.1 1 10 100 1000
diagnostics
Frequency[Hz] signal cable ⑦ Diagnostics TSM-1-W4 Used for ⑥
⑧ Setup fixture equipment
360 equipment cable Standard length 2m
⑧ Setup fixture TSM-1-M* Used for ①
180 *Nos 1、2、3 etc
No. Name Model No. Description
① Sensor0
unit TSM-1-S
② Signal distributor TSM-1-D
③ Sensor
−180
cable TSM-1-W1 Standard 10m
④ External signal cable TSM-1-W2 Standard 2m
⑤ Power
−360
cable TSM-1-W3 Standard 2m
Cable customized
0.001
to0.01
any length
0.1 1 10 100 1000
Measurement Range
1000kine
Design and specifications are subject to change without prior notice, and without any obligation on the part of the manufacturer.
100kine
10kine
1kine
CAUTION Before operating this equipment, you should first throughly read the operator's manual.
Velocity[m/s]
Horizontal component
100mkine
Vertical component
10mkine
1mkine
100μkine
10μkine
1μkine
0.01 0.1 1 10 100
Frequency[Hz]
Communication & Control Systems Company Sensing Control Systems Dept.
Head Office 2-16-46, Minami-Kamata, Ohta-ku, Tokyo 144-8551, JAPAN
TEL.+81-3-3731-2631 FAX.+81-3-3738-8670
December2016 Cat.No.1432-2-1-RG