MPLE2021 Sustainable Plumbing/ Plumbing Estimates

1. What is LEED?
a. Leadership in Energy and Environmental Design
b. Leadership in Excellence and Efficient Department
c. Leading Environmental and Energy Design
d. NOTA
2. How Many classification and certifications has LEED have?
a. 2
b. 3
c. 4
d. 5
3. Who was the president that signed the Philippine Green Building Code
a. President Fidel V. Ramos
b. President Jospeh E. Estrada
c. President Rodrigo R. Duterte
d. Preseident Benigno S. Aquino
4. What is ASPE
a. American Society of Private Engineers
b. Amercian Society of Practicing Engineers
c. American Society of Plumbing Engineers
d. NOTA
5. How many seasons do we have based 7. What is recycle material number 6
on the Weather based irrigation a. PVC
Controllers b. PP
a. 2 c. LDPE
b. 3 d. PS
c. 4 8. How many recycle material number do
d. NOTA we have
6. Recycle Material number of PP a. 4
a. 1 b. 5
b. 3 c. 6
c. 5 d. 7
d. 6
What IS 7

What IS What IS
What IS 8
6 10

What IS 9

9. What is number 6 m. Sufficient Rainfall ?


a. Specific Water Use Volume n. Backup Water
b. Add Additional Collection Suface o. Calculate Tank Capacity
c. Sufficient Rainfall ? 12. IF NO What is number 9
d. Backup Water p. Specific Water Use Volume
e. Calculate Tank Capacity q. Add Additional Collection Suface
10. IF NO What is number 7 r. Sufficient Rainfall ?
f. Specific Water Use Volume s. Backup Water
g. Add Additional Collection Suface t. Calculate Tank Capacity
h. Sufficient Rainfall ? 13. IF YES What is number 10
i. Backup Water u. Specific Water Use Volume
j. Calculate Tank Capacity v. Add Additional Collection Suface
11. IF YES What is number 8 w. Sufficient Rainfall ?
k. Specific Water Use Volume x. Backup Water
l. Add Additional Collection Suface y. Calculate Tank Capacity
14. Design a rainwater catchment with a roofsize of 1000 sq.m. and rainfall location is in manila?
Rainfall rate in Manila is 102mm/hr calculate the volume of tank and size ?
a. 102 cu.m ( 7.00m X 7.28m X 2.00m)
15. What is the commercial length of PVC pipe
a. 3
b. 4
c. 5
d. 6
16. In a 1 Storey house which consist of 1 T&B (Full Bath cold water only), Kitchen (with GT) and
Service Laundry outside has a length of 15m, From the Water Meter going to your building
Supply pipe the Architect specify to use PPR. Pipes, how many pcs. of PPR pipes will you use
a. 3
b. 4
c. 5
d. 2
17. How Many TEE will you use
a. 3
b. 4
c. 5
d. 6
18. What will be your Fixture supply diameter in size
a. 10
b. 13
c. 19
d. 25
19. What is the size of your Soil Pipe in in.Ø going to your main sewer in relation to question 13
a. 3
b. 4
c. 5
d. 6
20. If you will put a septic tank what will be its capacity in cu.m.
a. 2 (1 DC, 1 LC)
b. 3 (1 DC, 2 LC)
c. AOTA
d. Either A or B