Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

Fire Protection  U- Bolt G.I.

1”
 U- Bolt G.I. 3/4”
Automatic fire sprinkler system
 Angular Bracket 1- ½ x 1- ½ x 1.5mm]
Pipe  Adjustable clevis hanger 3”
 Adjustable clevis hanger 2”
 BI Pipe Schedule 40 4”  Adjustable clevis hanger 1”
 BI Pipe Schedule 40 3”  Adjustable clevis hanger ¾ ”
 BI Pipe Schedule 40 2”  Loop Hanger 3”
 BI Pipe Schedule 40 1”  Loop Hanger 2”
 BI Pipe Schedule 40 ¾”  Loop Hanger 1”
 BI Flange Schedule 40 4”  Loop Hanger 3/4”
 BI Flange Schedule 40 3”  Stud bolt
 BI Flange Schedule 40 2”
 BI Flange Schedule 40 1” Sprinkler
 BI Flange Schedule 40 ¾“
 Pendent type sprinkler head
 Blind Flange 4”
 Upright type sprinkler head
Seamless Connection Fittings  Standard silver escutcheon plate
 Siamese connection line brass type
 Tee non-reducer  FDC name plate
 Tee reducer 4”-3”
 Tee reducer 3”-2” Pump
 Tee reducer 2”-1”
 2- 400Gpm pump End Suction type
 Tee reducer 1”-3/4”
 2- 3 phase 60Hz 35 Hp pump electric
 Elbow 90
motor
 Reducer 4”-3”
 2 Jockey pump 3 Hp 30Gpm
 Reducer 3”-2”
 2 Supervisory panel with switch &
 Reducer 2”-1”
Settings for Fire Pump
 Reducer 1”-3/4”
 2 Supervisory panel with switch &
Threaded connection Fittings Settings for Jockey Pump

 Tee non-reducer Pump Accessories


 Tee reducer 4”-3”
 Pressure gauge with vacuum reading
 Tee reducer 3”-2”
 Rubber gaskets
 Tee reducer 2”-1”
 Alarm check valve
 Tee reducer 1”-3/4”
 Swing check valve (brass type)
 Elbow 90
 Alarm Gong
 Reducer 4”-3”
 Wye strainer 2”-3”
 Reducer 3”-2”
 Flow switch
 Reducer 2-1”
 Butterfly valve with supervisory switch
 Reducer 1”-3/4”
(4’)
Pipe support  Sight glass with flow indicator
 Globe valve purge valve
 U- Bolt G.I. 3”  Test Tee 2”
 U- Bolt G.I. 2”  Test tee 1”
 Test tee ¾ “  Sloping
 Test tee 1”
Water line
 Ball valve
 DMP valve  HDPE Pipe 1”
 Sensing line  HDPE Pipe ¾”
 Relief valve  G.I. Coupling1”
 Flow meter  G.I. Coupling ¾“
 OS & Y Gate Valve 4”  G.I. Coupling ½”
 OS & Y Gate Valve 3”  G.I. Plug 1”
 OS & Y Gate Valve 2”  G.I Plug ¾”
 G.I. Plug ½”
Tank
 G.I. Tee reducer 1”
 1pc 5,000L horizontal type Stainless  G.I. Tee reducer ¾”
steel 1.2mm thickness type-SS304  G.I. Tee reducer 1.2”
 4pc 8,000L horizontal type 1.2mm  PPR Pipe 1”
thickness type-SS304  PPR Pipe ¾”
 Fabricated tank ladder- Integrated to  PPR Pipe ½”
tank body  PPR Elbow 1”
 Tank top manhole with cover  PPR Elbow ¾”
 Tank support system (metal bracket and  PPR Elbow ½”
support  Check valve 1”
 2” tank suction line  Check valve ¾”
 2” tank discharge line  Check valve ½”
 PPR End cap
Pump room assembly
 Globe Valve 1”
 Metal fencing G.I. type  Globe Valve ¾”
 Metal sheet G.I type  Globe Valve ½”
 Tubular G.I Schedule 20 -2”
Vent System/ Sanitary Line Storm Drain
 G.I angular bar
 G.I. 2x3 tubular 1.5 mm  Sanitary Wye series 1000-6”
 Rib type long span roof  Sanitary Wye series 1000-4”
 Self-drilling screw with gasket  Sanitary Wye series 1000-3“
 Sanitary Wye series 1000-2”
Fire Detection and Alarm System (FDAS)
 Sanitary Elbow series 1000-6”
 Zoning panel  Sanitary Elbow series 1000-4”
 Smoke detector (addressable)  Sanitary Elbow series 1000-3“
 Electrical conduit  Sanitary Elbow series 1000-2”
 Electrical wiring  Sanitary P-trap series 1000-6”
 Metal strap for conduit line  Sanitary P-trap series 1000-4”
 Sanitary P-trap series 1000-3“
Embedded Pipelines for Fire Protection  Sanitary P-trap series 1000-2”
 Sand Bedding  PVC Coupling series 1000-6”
 Backfill  PVC Coupling series 1000-4”
 Excavations  PVC Coupling series 1000-3“
 PVC Coupling series 1000-2”
 Clean out plug 6”
 Clean out plug 4”
 Clean out plug 2”
 Wye Reducer 6”>4”
 Wye Reducer 4”>2”
 Metal straps
 Water Proofing Materials

Catch Basin

 CHB 4”
 Deformed bars- rebar (10mm)
 Sand
 Cement
 Water Proofing materials
 G.I. Angular bars (1.5mmx 1 ½ x 1 ½ )

Septic Tank

 Excavation
 Backfill
 CHB 4”
 Cement
 Gravel
 Sand
 10mm Deformed bars
 Water proofing works/ materials
 4” PVC series 1000
 Sanitary Tee series 1000
 Phenolic boards
 Clean outs with cap series 1000

Consumables (for pipe sealing)

You might also like