Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

PAB ACCREDITED

TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2010-167C

TEST REPORT
Rogin Arnel O. Sacdalan
Econ Global Builders Corp.
Looban 1, Brgy. Loma De Gato,
Marilao, Bulacan

Job Number : MNL23-0082


Client Ref. : n/a

Date Received : 02-Feb-2023


Date Reported : 09-Feb-2023

No. of Samples : 6
Report Content : Cover Sheet, Method Description, Final Report, Quality Control
Total Pages : 8

All work is performed in accordance with the Intertek Minerals Standard Terms and Conditions of work
http://www.intertek.com/terms/

This report relates specifically to the sample(s) that were drawn and/or provided by the client or their nominated third party.
The reported result(s) provide no warranty or verification on the sample(s) representing any specific goods and/or shipment
and only relate to the sample(s) as received and tested. Intertek will not be responsible for any damages caused to the
samples during their transit to Intertek's facilities and Customer acknowledges that the conditions surrounding the samples
during the transit may impact the results. This report was prepared solely for the use of the client named in this report.
Intertek accepts no responsibility for any loss, damage or liability suffered by a third party as a result of any reliance
upon or use of this report.

Only the Customer is authorized to permit copying or distribution of this report (and then only in its entirety).
Any such third parties to whom this report may be circulated rely on the content of the report solely at their own risk.

PAB Approved Signatory : Noted :

Emmy Rose Z. Del Rosario, RCh Marietta N. Salamanca, ChE, MSChem


Laboratory Operations Head Technical and Quality Manager
PRC License No.008487

Intertek Testing Services Philippines, Inc.


Building 7, Philcrest 1 Compound KM 23, West Service Road, Cupang, Muntinlupa City, Philippines
Tel: (632)88423464 -- TeleFax: (632)88425745 -- email address: min.apac.phl.lab@intertek.com
page 1 of 8
PAB ACCREDITED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2010-167C

METHOD DESCRIPTION
Client Ref : n/a Job Number : MNL23-0082

Method Code : FB1/XRF30


Bauxite Package by Li Borate Fusion / XRF

Method Code : UNK/LOI


Loss on Ignition.

Notes : NA = Not Analyzed


: I.S = Insufficient Sample
: L.N.R = Listed Not Received
: R.N.L = Received Not Listed

Intertek Testing Services Philippines, Inc.


Building 7, Philcrest 1 Compound KM 23, West Service Road, Cupang, Muntinlupa City, Philippines
Tel: (632)88423464 -- TeleFax: (632)88425745 -- email address: min.apac.phl.lab@intertek.com
page 2 of 8
PAB ACCREDITED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2010-167C

FINAL REPORT
Client Ref : n/a Job Number : MNL23-0082

SAMPLE Category Al2O3 BaO CaO Cr2O3 Fe2O3 K2O


UNITS % % % % % %
DET. LIMIT 0.01 0.01 0.01 0.005 0.01 0.01
METHOD FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30

W1 Primary 8.97 0.02 2.04 <0.005 5.87 0.46


W2 Primary 1.69 <0.01 0.07 <0.005 3.21 0.08
W3 Primary 0.52 <0.01 0.06 0.018 2.34 0.04
W4 Primary 10.75 0.03 1.31 0.030 5.92 1.36
W5 Primary 13.24 0.02 3.65 0.055 3.91 0.68
W6 Primary 14.00 0.02 1.63 0.021 3.50 0.64

Intertek Testing Services Philippines, Inc.


Building 7, Philcrest 1 Compound KM 23, West Service Road, Cupang, Muntinlupa City, Philippines
Tel: (632)88423464 -- TeleFax: (632)88425745 -- email address: min.apac.phl.lab@intertek.com
page 3 of 8
PAB ACCREDITED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2010-167C

FINAL REPORT
Client Ref : n/a Job Number : MNL23-0082

SAMPLE Category MgO MnO Na2O P2O5 SiO2 SO3


UNITS % % % % % %
DET. LIMIT 0.01 0.01 0.01 0.002 0.01 0.002
METHOD FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30

W1 Primary 1.17 0.08 1.46 0.073 76.93 0.013


W2 Primary 0.08 0.03 0.06 0.009 94.47 <0.002
W3 Primary 0.09 0.02 0.05 0.009 96.87 <0.002
W4 Primary 1.46 0.10 1.88 0.087 74.21 0.017
W5 Primary 0.49 0.04 3.30 0.022 70.67 0.126
W6 Primary 0.37 0.03 3.68 0.020 73.57 <0.002

Intertek Testing Services Philippines, Inc.


Building 7, Philcrest 1 Compound KM 23, West Service Road, Cupang, Muntinlupa City, Philippines
Tel: (632)88423464 -- TeleFax: (632)88425745 -- email address: min.apac.phl.lab@intertek.com
page 4 of 8
PAB ACCREDITED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2010-167C

FINAL REPORT
Client Ref : n/a Job Number : MNL23-0082

SAMPLE Category TiO2 V2O5 ZrO2 LOI


UNITS % % % %
DET. LIMIT 0.01 0.005 0.01
METHOD FB1/XRF30 FB1/XRF30 FB1/XRF30 UNK/LOI

W1 Primary 0.52 0.020 0.02 2.21


W2 Primary 0.11 <0.005 0.02 -0.02
W3 Primary 0.06 <0.005 0.01 -0.33
W4 Primary 0.48 0.015 0.02 2.15
W5 Primary 0.26 <0.005 0.02 3.38
W6 Primary 0.25 <0.005 0.02 1.97

Intertek Testing Services Philippines, Inc.


Building 7, Philcrest 1 Compound KM 23, West Service Road, Cupang, Muntinlupa City, Philippines
Tel: (632)88423464 -- TeleFax: (632)88425745 -- email address: min.apac.phl.lab@intertek.com
page 5 of 8
PAB ACCREDITED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2010-167C

QUALITY CONTROL
Client Ref : n/a Job Number : MNL23-0082

SAMPLE Category Al2O3 BaO CaO Cr2O3 Fe2O3 K2O


UNITS % % % % % %
DET. LIMIT 0.01 0.01 0.01 0.005 0.01 0.01
METHOD FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30

GBW07307a (GSD-7a) STD 11.02 0.05 2.95 0.006 4.18 1.82


Expected Value 11.02 0.05 2.96 0.006 4.18 1.83

Intertek Testing Services Philippines, Inc.


Building 7, Philcrest 1 Compound KM 23, West Service Road, Cupang, Muntinlupa City, Philippines
Tel: (632)88423464 -- TeleFax: (632)88425745 -- email address: min.apac.phl.lab@intertek.com
page 6 of 8
PAB ACCREDITED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2010-167C

QUALITY CONTROL
Client Ref : n/a Job Number : MNL23-0082

SAMPLE Category MgO MnO Na2O P2O5 SiO2 SO3


UNITS % % % % % %
DET. LIMIT 0.01 0.01 0.01 0.002 0.01 0.002
METHOD FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30 FB1/XRF30

GBW07307a (GSD-7a) STD 2.49 0.11 2.27 0.146 68.35 0.095


Expected Value 2.50 0.11 2.30 0.145 68.30 0.083

Intertek Testing Services Philippines, Inc.


Building 7, Philcrest 1 Compound KM 23, West Service Road, Cupang, Muntinlupa City, Philippines
Tel: (632)88423464 -- TeleFax: (632)88425745 -- email address: min.apac.phl.lab@intertek.com
page 7 of 8
PAB ACCREDITED
TESTING LABORATORY
PNS ISO/IEC 17025:2017
LA-2010-167C

QUALITY CONTROL
Client Ref : n/a Job Number : MNL23-0082

SAMPLE Category TiO2 V2O5 ZrO2 LOI


UNITS % % % %
DET. LIMIT 0.01 0.005 0.01
METHOD FB1/XRF30 FB1/XRF30 FB1/XRF30 UNK/LOI

GBW07307a (GSD-7a) STD 0.67 0.014 0.03


Expected Value 0.68 0.014 0.03

Intertek Testing Services Philippines, Inc.


Building 7, Philcrest 1 Compound KM 23, West Service Road, Cupang, Muntinlupa City, Philippines
Tel: (632)88423464 -- TeleFax: (632)88425745 -- email address: min.apac.phl.lab@intertek.com
page 8 of 8
End of Report

You might also like