Process Datasheet For MP Steam Condensate Pot (2109-V-809)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

SUSTAINABLE ENVIRONMENTAL POLLUTION

PREVENTION PLANT (SE3P)


BOT CONTRACT No.: 2- 96-5103

Unit Name: P05 - NGL


Process Datasheet for MP steam
Document Title Rev. : S-C1
Condensate Pot(2109-V-809)
Area Unit Disc. Doc. Seq. No.
Document Number Page 1 of 5
KHG3 21 PR DS 3040

Process Datasheet for MP steam Condensate


Pot(2109-V-809)

S-C1 22-Jun-2023 Approved for Construction P.B R.H P.SZ R.H A.M
S-C0 13-Apr-2021 Approved for Construction P.B R.H N.R R.H A.M
S-D0 09-Apr-2021 Issued for Approval P.B R.H N.R R.H A.M
Prep. Check Q.A. Appr. Appr. Appr.
Rev. Date Description Investor/
Engineering CONTRACTOR
Operator
SUSTAINABLE ENVIRONMENTAL POLLUTION
PREVENTION PLANT (SE3P)
BOT CONTRACT No.: 2- 96-5103

Unit Name: P05 - NGL


Process Datasheet for MP steam
Document Title Rev. : S-C1
Condensate Pot(2109-V-809)
Area Unit Disc. Doc. Seq. No.
Document Number Page 2 of 5
KHG3 21 PR DS 3040

TABULATION OF REVISED PAGES


Revisions Revisions
Sheet Sheet
D0 C0 C1 D0 C0 C1
1 x x x 41
2 x x x 42
3 x x 43
4 x x x 44
5 x x x 45
6 46
7 47
8 48
9 49
10 50
11 51
12 52
13 53
14 54
15 55
16 56
17 57
18 58
19 59
20 60
21 61
22 62
23 63
24 64
25 65
26 66
27 67
28 68
29 69
30 70
31 71
32 72
33 73
34 74
35 75
36 76
37 77
38 78
39 79
40 80
SUSTAINABLE ENVIRONMENTAL POLLUTION
PREVENTION PLANT (SE3P)
BOT CONTRACT No.: 2- 96-5103

Unit Name: P05 - NGL


Process Datasheet for MP steam
Document Title Rev. : S-C1
Condensate Pot(2109-V-809)
Area Unit Disc. Doc. Seq. No.
Document Number Page 3 of 5
KHG3 21 PR DS 3040

Rev. Design Data Units


Equipment Tag Number 2109-V-809
Type of Duty (Continuous / Intermittent) Continuous
Plane of vessel (Vertical / Horizontal) Vertical
Inside Diameter mm 1300
Length / Height (tan / tan) (Note 1) mm 3600
Type of Head (Top) 2:1 Elliptical
Type of Head (Bottom) 2:1 Elliptical
Material of (shell) CS
Material of construction (Internals) S.S
Wall Thickness mm (Note 2)
Corrosion Allowance mm 1.6
Insulation Type / Thickness mm HC 40mm
Mechanical Design Pressure barg 12
Min Design Pressure barg F.V
Mechanical Design Temperature ºC 205
Min Design Temperature ºC 0
Operating Conditions
Operating Pressure barg 10
Min Ambient Temperature ºC 0.0
Fluid Handled Steam Condensate
Flammable / Explosive No
Toxic No
Corrosive / Erosive No
Liquid Rate m3/hr 50.8( Note 3)
Liquid Temperature ºC 182
Molecular Weight (liq.) kg/kmol 18.02
Liquid density kg/m3 884.5
Viscosity (liq.) cP 0.1475
Vapor Rate kg/hr 0
Vapor Temperature ºC -
Molecular Weight (vap.) kg/kmol -
Vapor Density kg/m3 -
Z-Factor -
Viscosity (vap.) cP -
Details of Internals
Fitted with type A vortex breaker.
SUSTAINABLE ENVIRONMENTAL POLLUTION
PREVENTION PLANT (SE3P)
BOT CONTRACT No.: 2- 96-5103

Unit Name: P05 - NGL


Process Datasheet for MP steam
Document Title Rev. : S-C1
Condensate Pot(2109-V-809)
Area Unit Disc. Doc. Seq. No.
Document Number Page 4 of 5
KHG3 21 PR DS 3040

Rev. NOZZEL SCHEDULE


NZL No. Size Description Rating Flange Remark
N1 1 4” Inlet 150# RF
N2 1 2” Vapor Outlet 150# RF
N3 1 6” Liquied Outlet 150# RF
N4 1 2” Vent 150# RF
N5 1 2” Utility Connection 150# RF
S-C1 K1A/B 2 2” Level Transmitter 300# RF
S-C1 K2A/B 2 3” Level Bridle 300# RF
M1 1 18” Man Way 150# RF
S-C1 N6 1 2” Relief Valve 300# RF

NOTES
1. Liquid levels from the bottom tan-line are:

HLL 2900 mm
LLL 1600 mm
LLLL 300 mm

2. TBC by MECHANICAL
3. 10% design margin is already added.

General Notes:
1. Refer to P&lD: KHG3-21-PR-PI-3032
SUSTAINABLE ENVIRONMENTAL POLLUTION
PREVENTION PLANT (SE3P)
BOT CONTRACT No.: 2- 96-5103

Unit Name: P05 - NGL


Process Datasheet for MP steam
Document Title Rev. : S-C1
Condensate Pot(2109-V-809)
Area Unit Disc. Doc. Seq. No.
Document Number Page 5 of 5
KHG3 21 PR DS 3040

Rev.
S-C1

Note 1: Long Radius Elbow( end of elbow to be lower than LLLL)

You might also like