LiRAS TM

Line Reader & Analysis Software

Accurate and objective - Fast data entry and interpretation - Scanner calibration - LIMS connection
Customized reports - Accreditation and user-friendly - Data protection
Reliability for every run,

What you have to do

Start software Manual or Scanner calibration


automated data (once a month)

» » »
entry (LIMS)
0001001011101
0001001011101
0001001011101
1000101110010
1000101110010
1000101110010
0101110001001
0101110001001
0101110001001
0010001110101
0010001110101
0010001110101
0010110011100
0010110011100
0010110011100
0010010011011
0010010011011
0010010011011
1101101101011
1101101101011
1101101101011

HIGH FLEXIBILITY HIGH safety


• Customized reporting with potential • Data protection: Backup and Restore to safeguard the database
to insert your own laboratory header • CE-marked
or logo • Objective strip read-out
• Different report options: standard • User manual available in 8 languages
or summary report from 1 individual • Automated test review to approve or reject results
sample to a complete test run • User management: assign user privileges for your laboratory personnel

LiRAS™ for LiPA HPV


LiRAS™ for LiPA HLA
• Automated or manual data entry mode
• Automated or manual data entry mode
• HPV genotypes classified by presence and
• Typing table management
risk level (HR, pHR, LR, not classified)
• Allele code management
• HR and pHR genotypes displayed in red
• Standard report options:
- common alleles indicated in bold text font color; LR types in green font color and
- choose the resolution level: allele-group typing or detailed typing ‘not classified’ types in black font color
- include sequence information: per probe, per allele, or per pattern
- obtain supplementary advice for refinement of typing result (DRB)
- add serological information LiRAS™ for Infectious Diseases
• Translate detailed typing results into NMDP codes, simplify • Automated data entry mode
consultation of NMDP code look up • Different report options: standard,
summary and summary table report
every day

What LiRAS™ does for you!

Scanning & Reporting with Data export (LIMS)


­interpretation of electronic image of

» »
each strip the strip

REPORT
REPORT

HIGH EFFICIENCY HIGH QUALITY


• User-friendly and customizable interfaces • Scanning with online calibration
• Connection possible to Lab Information Management System (LIMS) guarding to provide accurate
• Filter management to select a subset of the database interpretation
• Fast data entry: automated or manual entry • Full traceability with audit trail
• Product specific messages with additional information and revision history

LiRAS™ for LIA ANA LiRAS™ for LiPA Cystic Fibrosis


• Automated data entry mode • Automated or manual data entry mode
• No worklist management and automated test review • Potential to:
- use legacy and/or HGVS nomenclature
- add patient ethnicity, date & place of birth
- exclude milder variants such as R117H

LiRAS™ for LiPA HBV


• Automated or manual data entry mode
• HBV control management
• Patient follow-up report*: overview of tests performed
per patient facilitating follow-up of drug resistance
patterns over time
* Only for CE version
System requirements

© April 2014 Fujirebio Europe


Contact Fujirebio Europe or your local distributor for further details.

Scanner
LiRAS™ is validated for use with selected types of scanners and the recommended reading templates.

Ordering information
Product description Article no.
LiRAS™ for Infectious Diseases v2 Software CE 81491
LiRAS for LiPA HBV v1 Software

CE 81387
LiRAS for LiPA HBV v1 Software

RUO 81386
LiRAS™ for LiPA HPV v2 Software CE 81492
LiRAS™ for LiPA HPV v2 Software RUO 81493
LiRAS for LiPA Cystic Fibrosis v3 Software

CE 81381
LiRAS for LiPA Cystic Fibrosis v2 Software

RUO 80674
LiRAS™ for LiPA HLA v6 Software CE 81435
LiRAS™ for LiPA HLA v6 Software RUO 81436
LiRAS for LIA ANA v1 Software

CE 81488
LiRAS for LIA ANA v1 Software

RUO 81490
LiRAS™ Report Translator Software to translate LiRAS™ reports 81434

LIA-Scan Reading Template 25 sheets 80493
LIA-Scan Reading Template (economic) 25 sheets 80543
LiPA-Scan Reading Template 25 sheets 80350
LiPA-Scan Reading Template (economic) 25 sheets 81541