Professional Documents
Culture Documents
Hydraulic Filter Division Automotive Catalog
Hydraulic Filter Division Automotive Catalog
Contamination Monitoring
Solutions for the Automotive Industry
1
Parker Automotive Filters
Providing the products and service our customers expect
A Global Product Range reduced set-ups, manufacturing Installations, fatigue test unit,
With this catalog, we offer our cell flexibility and fool-proofing cleanliness service (water
automotive customers an easy systems are all contributing to detection, special analysis,
way to find technical specification the continuous improvement in particle counting and analysis),
and ordering information about our manufacturing sites. ‘Lean’ 3D workstations, Thermal Cycle
Parker hydraulic filtration, fluid is also expressed in our premier Test Chamber, Salt Spray and
contamination monitoring and customer service and second-to- Humidity chambers.
fluid power products. none customer partnerships in
Parker Hannifin Corporation,
supply chain management.
Products shown in this herewith declares that Parker
catalog have a broad range of Hydraulic Filtration products are
applications. Our filter products Engineering and intended to be incorporated into
are particularly designed for manufacturing excellence machinery covered by Directive
hydraulic and lubrication systems Parker’s manufacturing focus 89/392/EEC, as amended and
and transmissions. The fluid is driven by a number of key that the following harmonized
power products are also used in elements that affect all areas of standards have been applied;
many industries and applications. the business. People productivity, EN982, EN292-1, EN292-2.
customer satisfaction, production
Typical applications can vary from throughput, quality and lean We furthermore declare that,
road sweepers, fork lift trucks, achievements are the drivers that machinery incorporating Parker
agriculture harvesting machines, help Parker achieve ISO9001, Hydraulic Filtration products,
grass cutting equipment, lorry QS9000, ISO9001 and ISO14001. is not allowed to be put into
mounted cranes, forestry service until the machinery has
equipment, press brakes, Significant investment by been found and declared to be in
industrial power units, waste our parent, Parker Hannifin conformity with the provisions of
management trucks, drilling Corporation, continues to give Directive 89/392/EEC and with
equipment, marine, military the Filtration Group flexible national implementing legislation.
equipment, paper mills, water manufacturing systems,
automated test equipment and In line with our policy of
treatment and filtration systems.
excellent laboratory test facilities. continuous product improvement,
For more information about our Parker Hannifin Corporation
products, send your inquiry to New product development reserves the right to alter product
your nearest sales location. See programs and on-going product data and specification without
contact information at the back of improvement initiatives are notice. This does not affect your
this catalog. vital elements in maintaining statutory rights.
a product range that meets
BSP ports offered in this catalog customer demands for quality,
conform to ISO228. reliability and engineering
excellence.
Supply chain management,
R & D resources at Parker
service and support
locations in the U.K., Finland,
Parker is addressing operation
The Netherlands and the U.S.
efficiency by expanding the
are both complementary and
systematic approach called ‘Lean
comprehensive. Including,
Manufacturing.’ Value stream
as examples, Multipass Test
analysis, flow manufacturing,
Notes:
1. Within this catalog, each product has been allocated an operating temperature and pressure range.
2. The range listed for each filter is dedicated by the materials of construction and the capability of the seals specified.
3. Consideration should also be given to the characteristics of the system fluid when specifying filters for extreme
temperature and/or pressure applications.
4. The use of non-Parker replacement elements and parts may invalidate your warranty.
2
Contents
Parker Automotive Filter Catalog
DIN Filters
High Pressure Electrical Information .....................................54
FDA, FDB .............................................................4
Offline Systems
Low Pressure Filters 5MFP/10MFP Filter Cart ....................................56
10DT, 16DT, 25DT ..............................................12 SMR Series.........................................................64
40RF, 50RF .........................................................16 PVS Series..........................................................75
Guardian® ..........................................................83
SOS..........................................................................
SAE Series ............................................................................94
High Pressure Filters
HF15P Series .....................................................18
HF3 Series ..........................................................22
HF3 Duplex.........................................................24 Reservoir Equipment
HF4 Series ..........................................................26 EAB Environmental Air Filters ............................98
HF4 Duplex.........................................................29 ABL Environmental Air Filters...........................102
AB Series Reservoir Breathers .........................106
Low Pressure Return Filters
HF2 Series – 15CN Return .................................34
HF3 Series – 40CN Return .................................38
Fluid Condition Monitoring
LaserCM Portable Particle Counter .................108
HF4 Series – IL4/DIL4 ........................................40
SPS – Single Point Sampler .............................116
System 20 – Inline Sensors ..............................119
High Flow Filters icountPD – Online Particle Detector ................120
IL8/HDIL8 Filters.................................................43 icountBS ...........................................................128
Moisture Sensor Range....................................134
Special Applications Filters Par-Test™ .........................................................141
Splash Lube Filter ..............................................52
3
DIN Series
High Pressure DIN Filters
4
FDA, FDB
High Pressure DIN Filters
5
FDA, FDB
Installation & Element Service Instructions
B
The filter should be mounted with the bowl down
and secured to a suitable bracket using the mounting
holes provided on the filter head. Ensure that the
filter is orientated so that the visual indicator, if
fitted, is clearly visible. The arrow stamped on the
filter head should coincide with the flow direction.
Length 3 - E
Length 1- C
Length 2- D
Element Servicing
Ensure that the hydraulic system is switched off and
that the pipework is de-pressurized. Drain fluid from
filter bowl by removing bowl drain plug if fitted. With
suitable spanner, unscrew the bowl from the filter
head revealing the dirty element. Grasp the element
and pull downwards with a slight twisting movement
to remove. Discard used element and check head
and bowl for damage. Clean inside bowl with
clearance 100 min.
Cartridge Removal
Dimensions
Length FDA FDA FDB FDB Filter Q = Across Flats
mm ins mm ins FDA Hexagonal
A 32 1.26 49 1.93 23.3/24.0 A/F
B 26 1.02 39 1.54 FDB Hexagonal
C 183 7.20 302 11.89 35.5/36.0 A/F
L
I 40 1.57 50 1.97
M
6
FDA, FDB
Indicators
P Indicator
4 LEDs giving visual indication:
• Green (G): Power ON
• Yellow 1 (Y1): Pre-alarm 1 (presetting 50%)
• Yellow 2 (Y2): Pre-alarm 2 (presetting 75%)
FMUX ATEX certified indicator -
• Red (R): Indication (presetting 100%) contact Parker
Setting range: 0,5 – 10 bar
Thermal lock-out range: 0°C – 100°C
Includes a microchip with memory logs
FMUF Electronic
Contact configuration
NPN
rt
Green LED
pa
4 0V
ed
max 300 mA Yellow LED’s
A
Fix
Red LED
PNP
3 +V
B
FMU F
PNP +10...36 Vdc
1 Load
Normally
open 2 Load
(N.O) C
4 0V D
max 300 mA
75% 2 active
U14M model U14H model
100% 1 active
7
FDA, FDB
Performance
To select the correct housing To find total pressure differential Total P = Housing P + Element P
and element, it is recommended through the filter assembly, Flow curves at 30 cSt viscosity.
that the ratio between the bypass add the ‘housing only’ pressure
setting and the differential differential to the ‘element only’
pressure across the filter with pressure differential, at the
a clean element, at the rated flow, rated flow.
should be at least 2:1.
FDA
FDB
FDA
Pressure Drop bar
FDB
20Q
20Q
8
FDA
Performance
2Q
2Q
Pressure Drop bar
10Q
10Q
20Q 20Q
2Q 2Q
5Q
5Q
10Q
10Q
20Q
20Q
9
FDB
Performance
3 3
2Q
2Q
2.5 2.5 10Q
5Q
Pressure Drop bar
0.5 0.5
0 0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
3 3
2Q 5Q 2Q
2.5 2.5
Pressure Drop bar
5Q 10Q
2 2
10Q
1.5 1.5
20Q
1 1
20Q
0.5 0.5
0 0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
10
FDA, FDB
Ordering Information
11
DIN Series
DIN Low Pressure Filters
12
10DT, 16DT, 25DT
Tanktop DIN Filters
Specification
13
10DT, 16DT, 25DT
Installation and Indicators
Installation
- 200 B - 180
25DT - 270
A
A
A
28
86
A
42
G1
port
16DT - G1 1/4
16DT - 299
25DT - 386
25DT - G 1 1/2
358
Seal Seal
4 Mounting
Holes Ø11 on
309
185 PCD
G1 1/2
G1
2 x Mounting
Holes 102 162
127
11
171
Measurements
mm
93.5
67
113
115
Measurements
70
mm
Gauge 3 LED
Indicator Indicator
P/N. S04479 P/N. S04478
14
10DT, 16DT, 25DT
Performance
To select the correct housing pressure across the filter with a Flow curves at 30cSt (140 SUS)
and element, it is recommended clean element, at the rated flow, viscosity show total pressure drop
that the ratio between the bypass should be at least 2:1. through housing and element.
setting and the differential
6μ
6μ
0.6 0.6 6μ 0.6 6μ
10
10μ 6μ
10μ 10
10μ
16
16μ
0.4 0.4 0.4 16
25
25μ 16μ 16μ
25μ 25
25μ
Ordering Information
The following filter assemblies Standard products table
are supplied WITH bypass and Part number Flow Ports Media Indication Indicator Bypass Replacement
indicator. (l/min) (BSP) rating (μ) rating rating (bar) elements
10DTA06EL50G16A 100 G1” 06 2.5 bar 3.5 bar 10DTEA05Q
10DTA10EL50G16A 100 G1” 10 2.5 bar 3.5 bar 10DTEA10Q
25DTA03EL50G24A 250 G11/2” 03 Electronic 2.5 bar 3.5 bar 25DTEA03Q
25DTA06EL50G24A 250 G11/2” 06 4 LED 2.5 bar 3.5 bar 25DTEA05Q
25DTA10EL50G24A 250 G11/2” 10 2.5 bar 3.5 bar 25DTEA10Q
15
40RF, 50RF
High Flow Tank Mounted Filters
Specification
Operating Temperature 40RF/50RF Housing Flow Curve 40RF Filter with 3Q Element
-40°C to 120°C (-40°F to 250°F)
30cSt (140SUS) 30cSt (140SUS)
Construction
0.3 0.6
2
1
Housing - iron; cover - iron; bowl - steel gt
h
th
0.5 n
ng
Le
Inlet Ports
Le
0.2 0.4
Model Type 0.3
40RF-1 2” 3000-M Flange face 0.1 0.2
40RF-2 21/2” 3000-M Flange face
0.1
50RF-1 3” 3000-M Flange face
0 0
0 200 400 600 800 1000 0 150 300 450 600 750
0.6 0.6
1
to indicate bypass condition or Electrical 2 2
th
h
1 gth gt
ng
h n n 1
pressure switch. (Note: Above options 0.5 t
Le
0.5
Le gt
h
Le
ng F en
Le
RF
0.6
1
50RF-1 36 (79.4) th
ng
0.5 Le
RF
1
50
th
ng
0.4
Le
Fluid Compatibility
RF
0.3 2
Suitable for use with mineral oils. For other th
40
eng
fluids, please consult Parker Filtration. 0.2
FL
4 0R
Seals 0.1
Nitrile 0
0 200 400 600 800 1000
Filter Element
Absolute 10, 20 micron microglass Flow (l/min)
16
40RF, 50RF
Installation Details
U C
B E
G
R ØP
A
ØH
Hole in tank ØJ
ØK
Electrical Pressure Switch P/N 1050911009
Dimensions (mm)
Model A B C D E F G H J
mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins
40 RF-1 267 10.51 73 2.87 120 4.72 260 10.24 80 3.15 34 1.34 23 0.91 178 7.01 180 7.09
40 RF-2 417 16.42 73 2.87 120 4.72 410 16.14 80 3.15 34 1.34 23 0.91 178 7.01 180 7.09
50 RF-1 402 15.83 80 3.15 136 5.35 410 16.14 85 3.35 34 1.34 23 0.91 194 7.64 205 8.07
Model K L M N P R S T U
mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins mm ins
40 RF-1 240 9.45 97 3.82 129 5.08 52 2.05 220 8.66 77.77 3.06 38.89 1.53 42.88 1.69 21.44 0.84
40 RF-2 240 9.45 97 3.82 129 5.08 52 2.05 220 8.66 88.9 3.50 44.45 1.75 50.8 2.00 25.40 1.00
50 RF-1 270 10.63 104 4.09 138 5.43 52 2.05 250 9.84 106.4 4.19 53.19 2.09 61.93 2.44 30.96 1.22
Ordering Information
Standard products table
Part number Flow Flow Ports Media Indication Indicator Bypass Replacement
(l/min) (g/min) (BSP) rating (μ) rating rating elements
40RF203QPPL50YG91 630 95 21/2” 03 G04711Q
40RF206QPPL50YG91 630 95 -3000 06 4 LED 2.5 bar 3.5 bar G04712Q
40RF210QPPL50YG91 630 95 flange 10 Electronic (36psi) (50psi) G04713Q
Note: Optional side-mounted indicator Part Number 940719
17
SAE Series
SAE High Pressure Filters
18
HF15P Series
High Pressure Filters
Pressure Filters - 3000 psi (207 bar) Application
Mounting Provisions
Pressure Ratings:
Maximum Allowable Operating Pressure (MAOP):
3000 psi (207 bar)
Rated Fatigue Pressure: 3000 psi (207 bar)
Design Safety Factor: 3:1
PORT TO PORT
4.00
2.750
1.375
TAP DRILL .62 DEEP
3/8-16 UNC-2B .44 MIN
FULL THD DEEP
TORQUE 30-40 FT-LBS
4 PLC'S
1.000
A A 2.000
4.200
2.78
ELECTRICAL
INDICATOR
3.12
2.95
7” (HF15P1)
10.8” (HF15P2)
ELEMENT REMOVAL
CLEARANCE
2.00 TORQUE 15-20 FT-LBS
n2.53
19
HF15P Series
Performance
PSID
BAR
BAR
10 10
ing
ous
0.5 H 0.5
mpty
5 5 E
0 0.0 0 0.0
0 5 10 15 20 0 5 10 15 20
GPM GPM
15 1.0 15 1.0
ou
PSID
PSID
BAR
BAR
yH
pt
10 10
Em
10μ
0.5 0.5
5 5
0 0.0 0 0.0
0 5 10 15 20 25 0 5 10 15 20 25
GPM GPM
Assembly P Formula
New New
P = P Empty Housing+ x Viscosity x Specific Gravity
Assembly Element P 150 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
20
HF15P Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11
HF15P 1 L 3 M2 50 ST12 19 V
BOX 1: Division Code BOX 6: Element Filtration Rating BOX 8: Indicator Setting
Symbol Description Symbol Description Symbol Description
None Leave Blank 3 3 Micron Microglass 50 50 psid (3.5 bar)
Note: Used for specific automotive 5 5 Micron Microglass 125 125 psid (8.6 bar)
program identification. F4MS/F4MN indicator with
10 10 Micron Microglass
option -21 only.
BOX 2: Plant Code 20 20 Micron Microglass
Symbol Description
BOX 9: Port Size
None Leave Blank Symbol Description
BOX 7: Indicator Type
Note: Used for specific automotive Symbol Description ST12 3/4-16 UN-2B
plant location. (ISO 11926)
M2 Visual
M27 M27 x 2 (ISO 6149)
BOX 3: Configuration E3B* Electrical/Visual
Symbol Description G12 G 3/4-14 BSPP
E4MB* Electrical/Visual
(ISO 1179-1)
HF15P 3,000 psi Filter E4MC* Electrical/Visual
SMP SAE Manifold Mount
E5B* Electrical/Visual
BOX 4: Housing Bowl Length MMP Metric Manifold Mount
Symbol Description E5MD* Electrical/Visual
GMP BSPP Manifold Mount
1 1 Element, 4” Long F4MS Standard Dual output
electrical indicator
2 1 Element, 8” Long BOX 10: Options
F4MN Device Net Dual output Symbol Description
electrical indicator 19 Drain Port on Bowl
BOX 5: Element Collapse Rating
Symbol Description F4MC MC Dual output electrical 21 Non-Bypass with Drain
H 2000 psi (138 bar) indicator
(-21 option in Box 10 *NOTE: Please refer to indicator
must be selected) BOX 11: Seal Compound
drawings and chart on pages 54 and 55
Symbol Description
L 150 psi (10 bar) for connector and wiring options.
V Fluorocarbon
(-19 option in Box 10
must be selected)
Replacement Elements
Element Single Length Double Length
Media Collapse Rating (Fluorocarbon) (Fluorocarbon)
3 Micron 150 psi (10 bar) HF21L3VQ HF22L3VQ
3 Micron 2000 psi (138 bar) HF21H3VQ HF22H3VQ
5 Micron 150 psi (10 bar) HF21L5VQ HF22L5VQ
5 Micron 2000 psi (138 bar) HF21H5VQ HF22H5VQ
10 Micron 150 psi (10 bar) HF21L10VQ HF22L10VQ
10 Micron 2000 psi (138 bar) HF21H10VQ HF22H10VQ
20 Micron 150 psi (10 bar) HF21L20VQ HF22L20VQ
20 Micron 2000 psi (138 bar) HF21H20VQ HF22H20VQ
21
HF3 Series
High Pressure Filters
Non-Bypass Design
HF3
Upstream and Downstream Test
Ports
Allows user to do maintenance
troubleshooting.
Mounting Provisions
15
sin
1.0
ou
PSID
BAR
yH
10
16.75
B) Determine micron selection.
10 0.5
C) For maximum filter life, 5
P should not exceed 1/3
bypass/indicator setting. 0 0.0
0 20 40 60 80 100
GPM
Assembly P Formula
New New
P = P from curve x Viscosity x Specific Gravity
4.38
Assembly 300 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
22
HF3 Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11 BOX 12 BOX 13
HF 3 1 P3 H 3 M2 50 ST16 11 V
BOX 1: Division Code BOX 7: Element Collapse Rating BOX 10: Indicator Setting
Symbol Description Symbol Description Symbol Description
None Leave Blank H 2000 PSI 50 50 psid (3.5 bar)
(-11 option, Box 12)
Note: Used for specific automotive 125 125 psid (8.6 bar)
program identification. F4M indicator
BOX 8: Element Filtration Rating
BOX 2: Plant Code Symbol Description BOX 11: Port Size
Symbol Description 3 3 Micron Microglass Symbol Description
None Leave Blank 5 5 Micron Microglass ST16 1 5/16-12 UN-2B
Note: Used for specific automotive (ISO 11926)
10 10 Micron Microglass
plant location. M33 M33 x 2 (ISO 6149)
*Consult factory for other requirements.
G16 1-11 BSPP
BOX 3: Configuration (ISO 1179G228)
Symbol Description BOX 9: Indicator Type
Symbol Description
HF Hydraulic Filter BOX 12: Options
M2 Visual
Symbol Description
BOX 4: Element Diameter E3B* Electrical/Visual 11 Non-Bypass
Symbol Description E4MB* Electrical/Visual
3 3 inch (NOMINAL) BOX 13: Seal Compound
E4MC* Electrical/Visual
Symbol Description
E5B* Electrical/Visual
BOX 5: Housing Bowl Length V Fluorocarbon
Symbol Description E5MD* Electrical/Visual
1 1 Element, 8” Long F4MS Standard Dual output
electrical indicator
BOX 6: Housing Pressure Type F4MN Device Net Dual output
Symbol Description electrical indicator
P3 Pressure Type
F4MC MC Dual output electrical
indicator
*NOTE: Please refer to indicator drawings
and chart on pages 54 and 55 for
connector and wiring options. Located at
left side of inlet — for right side, add “R”
to symbol. Example: E3BR.
Replacement Elements
Element Single Length
Media Collapse Rating (Fluorocarbon)
3 Micron 2000 psi (138 bar) HF31H3VQ
5 Micron 2000 psi (138 bar) HF31H5VQ
10 Micron 2000 psi (138 bar) HF31H10VQ
23
HF3 Duplex
High Pressure Filter
Installation Dimensions
Fatigue Pressure: 3000 psi (207
244.3 bar)
9.62 72.4 136.7
122.2 2.85
4.81 5.38
MAX.
IN
152.4 FILTER SCEMATIC
OPERATING
6.00 INS NS
IO N
101.6
4.00 mm
R O TAT
in.
1"SAE Inlet
16 & 333.3
(1.312 Outlet
12 UN 2B) 13.12
309.4
12.18 STRAIGHT Max.
Ports
THREAD BOSS
MAX.
F BOTH PORTS
IN ILTE
SE R
RV
IC
E
152.4
6.00
MAX.
275.6 2.75 101.6
10.85 .25 28.4 9.00 MIN.
1.12 HEX ELEMENT
REMOVAL
CLEARANCE
24
HF3 Duplex Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11
30PDHF3 2 L 10 E5MD 50 ST16 19 V
BOX 1: Division Code BOX 6: Element Filtration Rating BOX 8: Indicator Setting
Symbol Description Symbol Description Symbol Description
None Leave Blank 3 3 Micron Microglass 50 50 psid (3.5 bar)
Note: Used for specific automotive 5 5 Micron Microglass 125 125 psid (8.6 bar)
program identification. F4M indicator with
10 10 Micron Microglass
Option -21 only.
BOX 2: Plant Code *Consult factory for other requirements.
Symbol Description
None Leave Blank BOX 7: Indicator Type BOX 9: Port Size
Symbol Description Symbol Description
Note: Used for specific automotive
plant location. M2 Visual ST16 1 5/16-12 UN-2B
E3B* Electrical/Visual (ISO 11926)
Replacement Elements
Element Single Length
Media Collapse Rating (Fluorocarbon)
3 Micron 150 psi (10 bar) HF31L3VQ
3 Micron 2000 psi (138 bar) HF31H3VQ
5 Micron 150 psi (10 bar) HF31L5VQ
5 Micron 2000 psi (138 bar) HF31H5VQ
10 Micron 150 psi (10 bar) HF31L10VQ
10 Micron 2000 psi (138 bar) HF31H10VQ
25
HF4 Series
High Pressure Filter
Elements
3, 5 and 10 micron HF4 elements
with ß ≥ 200 with dual stage
filtering media for up to 40% 50P4-2
increased dirt holding capacity.
Length 50P4-1
FDA 50P4-2
FDB
Linear Measure: millimeter X 254.0 508.0
inch 10.00 20.00
Z 387.1 622.8
15.24 24.52
OUTLET
(2-128 O-RING)
22.4 7.9
.31 79.4
.88 98.0 3.125 39.6
3.86
127.0 1.56
5.00 50.8 INLET
63.5 2.00 (2-128 O-RING)
2.50 34.8 12.7
1.37 .50
34.9
14.3 MOUNTING 36.5
1.375 .563 HOLES
DIA. THRU 1.437
DIA. C 42.8 57.2
BORE 1.685 2.25
1.95 114.3 38.1 18.3
DEEP .0775 4.50 DIA. THRU
1.50 .72
162.6
6.40
ELEMENT REMOVAL
CLEARANCE
BLEED PORT TORQUE
X 20-25 FT LBS
TORQUE
45-50 FT LBS.
Z
DRAIN
PORT
34.8 OUTLET
OPTIONAL 1.37 68.1
RIGHT HAND 2.68
INDICATOR
“YY” “PP” TORQUE
Note: For Ports 12.7 115-130 FT LBS.
.50 92.2 158.8 161.8
See Order Page 3.63 6.25 6.37 OPTIONAL FLANGE
26
HF4 Series
Performance
15 1.0 15 1.0
PSID
PSID
BAR
BAR
5μ
10 10
Empty Housing
10μ 0.5 0.5
5 5
0 0.0 0 0.0
0 20 40 60 80 100 0 20 40 60 80 100
GPM GPM
15 1.0 15 1.0
PSID
PSID
BAR
BAR
5μ
10 10
0.5 ing 0.5
10μ ous
5 5 H
mpty
E
0 0.0 0 0.0
0 30 60 90 120 150 0 30 60 90 120 150
GPM GPM
Assembly P Formula
New New
P = P Empty Housing+ x Viscosity x Specific Gravity
Assembly Element P 150 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
27
HF4 Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11
50P4 1 H 10 E4MB 50 FM 11 V
BOX 1: Division Code BOX 6: Element Filtration Rating BOX 8: Indicator Setting
Symbol Description Symbol Description Symbol Description
None Leave Blank 3 3 Micron Microglass 50 50 psid (3.5 bar)
Note: Used for specific automotive 5 5 Micron Microglass 125* 125 psid (8.62 bar)
program identification.
10 10 Micron Microglass *NOTE: Only available on F4MS and
F4MN indicators.
BOX 2: Plant Code *Consult factory for other requirements.
Symbol Description
None Leave Blank BOX 7: Indicator Type BOX 9: Port Size
Symbol Description Symbol Description
Note: Used for specific automotive
plant location. IR Visual, Right Side ST24 1 7/8-12 UN-2B
IL Visual, Left Side (ISO 11926)
28
HF4 Duplex
Medium and High Pressure Filters
MPD/MPDH/Duplex Pressure
Filter - MPD – Dual 1500 psi (103
bar), MPDH – Dual 3000 psi (207
bar)
• True duplex design with full
neutral center valve
• SAE porting
• Flows to 110 gpm (416
l/min)
• Modular design with
double- or triple-length side
chamber extensions
• Internal equalization
• HF4 elements as standard
• Non Bypass Option
Pressure Ratings:
Maximum Allowable Operating
Pressure (MAOP):
MPD – 1500 psi (103 bar)
MPDH – 3000 psi (207 bar)
29
HF4 Duplex
Performance
Capacity
PSID BAR
50
6.0
40
5.0
30
4.0
5μ
3.0
20
μ
10
2.0
10
3μ 1.0
0 0.0
0 20 40 60 80 100 120
Grams
15 1.0 15 1.0
PSID
PSID
BAR
BAR
5μ
10 10
0.5 ing 0.5
10μ ous
5 5 H
mpty
E
0 0.0 0 0.0
0 30 60 90 120 150 0 30 60 90 120 150
GPM GPM
Assembly P Formula
New New
P = P Empty Housing+ x Viscosity x Specific Gravity
Assembly Element P 150 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
30
HF4 Duplex
Performance
Capacity
PSID BAR
100
10μ 6
80
3μ
5
60
4
3
40
5μ
20
1
0 0
0 50 100 150 200
Grams
25 25
150 SUS (32cSt) 150 SUS (32cSt)
Empty Housing
1.5 1.5
20 20
3μ
15 15
1.0 1.0
PSID
PSID
BAR
BAR
5μ
10 10
0.5 0.5
5 5
10μ
g
usin
ty Ho
Emp
0 0.0 0 0.0
0 30 60 90 120 150 0 30 60 90 120 150
GPM GPM
Assembly P Formula
New New
P = P Empty Housing+ x Viscosity x Specific Gravity
Assembly Element P 150 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
31
HF4 Duplex Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11
MPD 1 L 10Q E5MD 25 FS 1 V
32
HF4 Duplex
Medium and High Pressure
Notes
33
SAE Series
Return Filters
34
15CN Return Filter: HF2 Series
HF2 Series Filters
Low Pressure
15CN Return Filters - 800 psi (55
bar) Applications
Element
HF2 4” and 8” Long. 3, 5, and 10
micron element with ß ≥ 200 and
dual stage filtering media for up
to 40% increased dirt holding
capacity.
Mounting Provisions
Reverse Check Option
For system decompression,
includes Element Check to
prevent back flow during system Reverse Check Option 3.25[82.6] Ma x
decompression. 1.50[38.1]
4 Mounting holes
25 PSID 1/4”-2 oz x .31[7.8]
visual/ min. full thd depth
Pressure Ratings: 3 PSID electrical
check differential
Maximum Allowable Operating valve indicator
3.38[85.9]
(55 bar)
2.75[69.9] Ma x
Ou t Visual/electrical
indicator
In
HF2-4P2
9.87 (250.7) Bowl torque 15-20 ft-lbs
±.12[±3.1] [20.3-27.1 nm ]
1.00[25.4]
Nominal he x
2.80[71.1] Ma x
35
15CN Return Filter: HF2 Series
Performance
25 25
150SUS 150SUS (32cSt)
(32cSt) 5μ EMPTY HOUSING
1.5 1.5
20 20
3μ
10μ
15 15
1.0 1.0
PSID
PSID
BAR
BAR
10 10
0 0.0 0 0.0
0 5 10 15 20 0 5 10 15 20
GPM GPM
25 25
150 SUS (32cSt) 150 SUS (32cSt)
3μ EMPTY HOUSING
1.5 1.5
20 20
5μ
15 15
1.0 1.0
PSID
PSID
BAR
BAR
10μ
ze
Si
rt
Po
10 10
al
in
m
0.5
No
0.5
”
¾
5 5
0 0.0 0 0.0
0 5 10 15 20 25 0 5 10 15 20 25
GPM GPM
Assembly P Formula
New New
P = P Empty Housing+ x Viscosity x Specific Gravity
Assembly Element P 150 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
36
15CN Return Filter: HF2 Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11
15CN 2 L 10 E5B 25 ST12 19 V
BOX 1: Division Code BOX 6: Element Filtration Rating BOX 8: Indicator Setting
Symbol Description Symbol Description Symbol Description
None Leave Blank 3 3 Micron Microglass 25 25 psid (1.7 bar)
Note: Used for specific automotive 5 5 Micron Microglass 35 1
35 psid (2.4 bar)
program identification.
10 10 Micron Microglass 50 50 psid (3.5 bar)
Replacement Elements
Element Single Length Double Length
Media Collapse Rating (Fluorocarbon) (Fluorocarbon)
3 Micron 150 psi (10 bar) HF21L3VQ HF22L3VQ
3 Micron 2000 psi (138 bar) HF21H3VQ HF22H3VQ
5 Micron 150 psi (10 bar) HF21L5VQ HF22L5VQ
5 Micron 2000 psi (138 bar) HF21H5VQ HF22H5VQ
10 Micron 150 psi (10 bar) HF21L10VQ HF22L10VQ
10 Micron 2000 psi (138 bar) HF21H10VQ HF22H10VQ
37
40CN Return Filter: HF3 Series
HF3 Series Filters
Low Pressure
40CN Return Filter - up to 800 Torque
25 - 30 ft. lbs.
psi (55 bar) Application
M2 - 3.07 (78.0)
Non-Bypass Option E3, E4, E5 - 3.17(80.5)
Element Torque
42 - 50 ft. lbs.
Assembly P Formula
New New
P = P Empty Housing+ x Viscosity x Specific Gravity
Assembly Element P 150 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
LPM LPM
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
40CN HF3-2 Element
Performance 25
150 SUS (32cSt)
25
150 SUS (32cSt)
EMPTY HOUSING
3μ 1.5 1.5
20 20
15 15
Flow vs. 1.0 1.0
PSID
PSID
BAR
BAR
5μ
Pressure Loss
10 10 ze
Si
rt
10μ l Po
0.5 a 0.5
in
m
5 5 ” No
1½
0 0.0 0 0.0
0 20 40 60 80 100 0 20 40 60 80 100
GPM GPM
38
40CN Return Filter: HF3 Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11
40CN 2 L 10 E3B 50 ST24 19 V
BOX 1: Division Code BOX 6: Element Filtration Rating BOX 8: Indicator Setting
Symbol Description Symbol Description Symbol Description
None Leave Blank 3 3 Micron Microglass 25 25 psid (1.7 bar)
Note: Used for specific automotive 5 5 Micron Microglass 35 1
35 psid (2.4 bar)
program identification.
10 10 Micron Microglass 50 50 psid (3.5 bar)
Replacement Elements
Element Single Length
Media Collapse Rating (Fluorocarbon)
3 Micron 150 psi (10 bar) HF31L3VQ
3 Micron 2000 psi (138 bar) HF31H3VQ
5 Micron 150 psi (10 bar) HF31L5VQ
5 Micron 2000 psi (138 bar) HF31H5VQ
10 Micron 150 psi (10 bar) HF31L10VQ
10 Micron 2000 psi (138 bar) HF31H10VQ
39
HT4/IL4/DIL4 Filter: HF4 Series
Low Pressure HF4 Series Filters
Elements
3, 5, and 10 micron HF4
elements with ß ≥ 200 with dual Hex head bolt torque
45°
stage filtering media for up to 40% (Typ.)
200-225 in-lbs
.440 4-Total
increased dirt holding capacity. equally spaced
Torque
as shown
32-38 ft-lbs
Oil coated
IL4
HT4
IL4-1
40
IL4/DIL4 Filter: HF4 Series
Performance
5μ
15 1.0 15 1.0
PSID
PSID
BAR
BAR
10 10
0 0.0 0 0.0
0 20 40 60 80 100 0 20 40 60 80 100
GPM GPM
15 1.0 15 1.0
PSID
PSID
BAR
BAR
5μ
10 10
0.5 0.5
5 5
10μ Empty Housing
0 0.0 0 0.0
0 20 40 60 80 100 0 20 40 60 80 100
GPM GPM
Assembly P Formula
New New
P = P Empty Housing+ x Viscosity x Specific Gravity
Assembly Element P 150 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
41
IL4/DIL4 Filter: HF4 Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10
IL4 2 L 10 E5MD 25 FM V
BOX 1: Division Code BOX 6: Element Filtration Rating BOX 9: Port Size
Symbol Description Symbol Description Symbol Description
None Leave Blank 3 3 Micron Microglass HT4
Note: Used for specific automotive INLET OUTLET
5 5 Micron Microglass
program identification. P24 1 1/2” NPT 1 1/2” NPT
10 10 Micron Microglass
ST24 1 7/8-12 UN-2B 1 1/2” NPT
BOX 2: Plant Code (ISO 11926)
Symbol Description BOX 7: Indicator Type
Symbol Description G24 1 1/2-11 BSPP 1 1/2” BSPP
None Leave Blank
IR Visual, Right Side (ISO 1179G-228)
Note: Used for specific automotive
IL Visual, Left Side FS 2” Flange 1 1/2” NPT
plant location.
(ISO 6162),
E3B* Electrical/Visual 1/2-13 bolt holes,
BOX 3: Configuration 3/4” deep
E4MB* Electrical/Visual
Symbol Description
E4MC* Electrical/Visual FM 2” Flange 1 1/2” BSPP
HT4 In-Tank Return Filter
(ISO 6162),
IL4 In-line Return Filter E5B* Electrical/Visual M12 x 1-3/4
E5MD* Electrical/Visual bolt holes,
DIL4 In-line Duplex Filter
19.5 mm deep
F4MS Standard Dual output
electrical indicator
BOX 4: Housing Bowl Length IL4
F4MN Device Net Dual output
Symbol Description INLET & OUTLET
electrical indicator
1 Single Length P24 1 1/2” NPT
F4MC MC Dual output electrical ST24 1 7/8-12 UN-2B (ISO 11926)
2 Double Length indicator
G24 1 1/2-11 BSPP (ISO 1179G-228)
*NOTE: Please refer to indicator drawings FS 2” Flange (ISO 6162), 1/2-13
BOX 5: Element Collapse Rating and chart on pages 54 and 55 for
Bolt Holes, 3/4” deep
Symbol Description connector and wiring options. Located at
left side of inlet — for right side, add “R” FM 2” Flange (ISO 6162), M12 x
L 150 PSI (10 bar)
to symbol. Example: E3BR. 1-3/4 bolt holes, 19.5 mm deep
Replacement Elements
Element Single Length Double Length
Media Collapse Rating (Fluorocarbon) (Fluorocarbon)
3 Micron 150 psi (10 bar) HF41L3VQ HF42L3VQ
5 Micron 150 psi (10 bar) HF41L5VQ HF42L5VQ
10 Micron 150 psi (10 bar) HF41L10VQ HF42L10VQ
42
IL8/HDIL8 Filter
Low Pressure
43
IL8/HDIL8 Filter
Low Pressure
Microglass III -
Replacement Elements
Microglass III represents a leap enhanced in the IL8 series with
forward in the performance the introduction of the deep pleat
obtainable in hydraulic and lube design. The deep pleat element
filter elements. design increases the amount
of media in the element and
The unique multi-layer design therefore capacity.
combines high efficiencies
with exceptional dirt holding With Microglass III you do not
capacities for performance that have to make a compromise
is unequalled in the industry between efficiency and capacity,
today. This performance is further you can have both.
44
IL8/HDIL8 Filter
IL8-1 Performance
Capacity
PSID BAR
100
10µ
6
80
5
60
4
40 3
2
20
3µ 1
5µ
0 0
0 20 40 60 80 100 120
Grams
15 1.0 3
0.20
PSID
PSID
SAE-32
BAR
BAR
5µ e
ac 0.15
10 2 eF
g
an
10µ Fl
0.5 2 0.10
E-
5 1 SA
0.05
0 0.0 0 0.0
0 30 60 90 120 150 0 30 60 90 120 150
GPM GPM
45
IL8/HDIL8 Filter
IL8-2 Performance
Capacity
PSID BAR
60 4
50
3
40
30 2
10µ
20
3µ
1
10
5µ
0 0
0 60 120 180 240 300 360
Grams
Multipass tests run @ 50 gpm to 50
psid terminal - 10mg/L BUGL
15 6
ng
1.0 0.4
Fla
PSID
BAR
BAR
PSI
SAE-24
2
5µ
E-
0.3
SA
10 4
0 0.0 0 0.0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
GPM GPM
46
IL8/HDIL8 Filter
IL8-3 Performance
Capacity
PSID BAR
60 10µ
4
50
3
40
30 2
5µ
20
1
µ
3
10
0 0
0 200 400 600 800 1000 1200 1400
Grams
Multipass tests run @ 70 gpm to 50
psid terminal - 10mg/L BUGL
SAE-32
ac
5µ 0.5
eF
SAE-24
ng
6 15
Fla
0.4 1.0
PSID
PSID
10µ
2
BAR
BAR
E-
SA
4 0.3 10
0.2 0.5
2 5
0.1
0 0.0 0 0.0
0 75 150 225 300 375 450 0 75 150 225 300 375 450
GPM GPM
47
IL8 Filter
Specifications
Pressure Ratings:
Maximum Allowable Operating 158.8
Single
6.25
Pressure (MAOP): 500psi (34.5 377.7
Double
bar) Element 14.87
Removal Clearance 934
Rated Fatigue Pressure: 330 psi Triple
36.77
(22 bar)
Design Safety Factor: 3:1
Operating Temperatures:
Buna: -40°F (-40°C) to 225°F
436±7
(107°C) Single
17.11±.25
Fluorocarbon: -15°F (-26°C) to
275°F (135°C)
Shipping Weights
(approximate): 158.8
Single 6.25
Single: 40 lbs. (18.1 kg) 377.7
Double
Double: 50 lbs. (22.7 kg) Element 14.87
Removal Clearance 934
Triple: 75 lbs. (34 kg) Triple
36.77
436±7
Single
17.11±.25
Linear Measure:
millimeter
inch
653±7
Double 25.71±.25
48
HDIL8/HQIL8 Filter
Specifications
Flow LPM
0 500 1000 1500
7
e
alv
5
0
e
00
2
V alv
4" .3
ve
4 l S
Va SU
3"
ve
0
20
al
V
3 3" US .2
S 00S
SU 2
00
2 20
.1
1
0 0
0 50 100 150 200 250 300 350 400 450 500
Flow LPM
49
HDIL8/HQIL8 Filter
Specifications
Linear Measur e: millimeter
inch
1704. 5
33.55
HDIL8 EQUALIZING VALV E 203. 2
MOUNTING HOLES 8.00
Top View .66 DIA THRU 16 TOTAL 165. 1
6.50 TORQUE 30-45 fT-LBS.
228. 6
9.00
165. 1 203. 2
6.50 8.00
177. 8
7.00
COVER
HDIL8/HQIL8 HANDLE 180¡ HANDLE
TORQUE: M2 STYLE SH OWN
431. 8 RO TATION F OR TORQUE 30-45 FT-LB S
Side View (-2) 17. 0
HAND H STYLE CHANGE OVER
MINIMUM ELEMENT TIGHT SHOWN
REMOV AL CLEARANCE TORQUE
(-3) 990. 6 30-45 FT-LB S
39. 0
763.75
(-2) 30.07
692. 7
(-2) 27.27 (-3) 1320. 6
51.99
(-3) 1249. 5 1 SAE-16 STR
49.19 300
THD DRAIN
11.81 PORT T ORQUE:
427. 0
16.81 85-100 FT-LB S
16. 0
.6 3
65. 5
ST ANDARD SAE PORTIN G
2.58
HQIL8 771.55
30.38
Top View
203. 2
THD VENT PORT 8.00
TORQUE 10-15 165. 1
FT.-LBS . 6.50
EQUALIZING
VALVE
165. 1 203. 2
587.35 6.50 8.00
23.12
624.85
24.60
366. 7 568. 3
MOUNTING HOLES .66 DIA
14.44 11.19 THRU 16 TOTAL
733. 5
28.88
50
IL8/HDIL8/HQIL8 Filter
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11
IL8 3 R 10QE E3BP 50 ST24 1 V
BOX 1: Division Code BOX 6: Element Filtration Rating BOX 8: Indicator Setting
Symbol Description Symbol Description Symbol Description
None Leave Blank 3 3 Micron Microglass 25 25 psid (1.7 bar)
Note: Used for specific automotive 5 5 Micron Microglass 35 1
35 psid (2.4 bar)
program identification.
10 10 Micron Microglass 50 50 psid (3.5 bar)
BOX 4: Housing Bowl Length IL Visual, Left Side FS4 4” SAE Flange Face
Symbol Description (code 61)
E3B* Electrical/Visual
1* Single Length
E4MB* Electrical/Visual
2 Double Length BOX 10: Options
E4MC* Electrical/Visual Symbol Description
3 Triple Length
E5B* Electrical/Visual 1 None
*NOTE: Not available for HDIL8 or HQIL8.
E5MD* Electrical/Visual 11 Blocked bypass
F4MS Standard Dual output
BOX 5: Core
electrical indicator BOX 11: Seal Compound
Symbol Description
F4MN Device Net Dual output Symbol Description
None Disposable Core
electronic indicator V Fluorocarbon
R Reusable Core
F4MC MC Dual output electrical
Notes:
indicator
1. 35 psid indicator setting only available in F4M
NOTE: Two symbols required. First is for
indicator type.
housing, second is for the cover(s). Electrical
indicators only available on the housing.
*Please refer to indicator drawings and chart
on pages 54 and 55 for connector and wiring
options.
Replacement Elements
Microglass III (Fluorcarbon) Ecoglass III (Fluorcarbon)
Media Single Double Triple Media Single Double Triple
3 927663Q 933044Q 932872Q 02QE NA 933834Q 933734Q
5 927861Q 933045Q 932873Q 05QE NA 933835Q 933612Q
10 927661Q 933046Q 932874Q 10QE NA 933836Q 933735Q
Reusable NA 933838 933636
Core
51
Splash Lube Filter
Special Applications Filters
Non-Bypass Design
Prevention Feature
Prevents filter operation without
element in place.
Mounting Provisions
Located on top of filter.
Optional electrical
indicator shown
3.82[96.5]
3.74
[95.00]
1.50
Slat Assembly [38.10]
BAR
6.81[172.97]
4 Max
5.68[148.84]
0.2
2 In Out
0 0.0 .62[15.7]
0 4 8 12 16 Minimum
removal
GPM clearance
Assembly P Formula
New New
P = P Empty Housing+ x Viscosity x Specific Gravity
Assembly Element P 150 .90
Note: For “H” High collapse elements use 1.4 x P from curves above.
52
Splash Lube Filter
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
Replacement Canisters
Symbol Part Number
10C 921999
25C 925023
53
Electrical Information
Pictorial Guide and Specifications
F4M Electronic Indicator
Part Indication
Number Pressure
PNP N/C 937037 8.5 bar
Standard W3 (125 psi) DC3 Pressure Switch
PNP N/C 942638 8.5 bar Type SE Electrical Housing
F4MS
Standard W6 (125 psi)
PNP N/C 942711 1.5 bar
Standard W3 (22 psi)
PNP N/C 937409 8.5 bar
Device Net W3 (125 psi)
PNP N/C 942743 8.5 bar
F4MN
Device Net W6 (125 psi)
PNP N/C 942744 1.5 bar
Device Net W3 (22 psi)
942745 8.5 bar
PNP N/C
W3 (125 psi)
942746 8.5 bar HF2, HF3, HF4
F4MC PNP N/C
W6 (125 psi)
Type E Electrical Indicator
942747 1.5 bar
PNP N/C
W3 (22 psi)
SLAT
Type PS Electrical Indicator
Change Circuit
Circuit Supply Ground P1-C
Ground PIN-3 Filter PIN-3
PIN-4 PIN-4 Key
Change
Shut Filter
Down Change Supply Shut Down P4-NC Shut
PIN-1 Filter PIN-1 PIN-2 P2-NC Down
PIN-2 P3-Circuit
Key Key
Ground
3 +V 1 +V 1 +V
10-36 VDC 10-36 VDC 10-36 VDC
2 * 4 * 2 *
FPC .F FPC .F FPC .F
PNP Load PNP Load PNP Load
1 * 2 * 4 *
Load Load Load
4 0V 3 0V 3 0V
* MAX 300 MA * MAX 300 MA * MAX 300 MA
54
SAE Series Filters
Electrical Information
MINI SHOWN
Mini Connector
MICRO SHOWN
Micro Connector
55
Portable Filter Carts
Models 5MFP & 10MFP with Moduflow™
and Intelli-Cart™
56
Portable Filter Carts
Applications
• Filtering new fluid before Parker portable filter carts are Once water comes into contact
putting into service the ideal way to prefilter and with this material, it is removed
• Transferring fluid from transfer fluids into reservoirs or from the system.
drums or storage tanks to to clean up existing systems.
The Parker portable filter
system reservoirs Fluid should always be filtered cart uses two high capacity
• Conditioning fluid that is before being put into use. New ModuFlow™ Plus filters for long
already in use fluid is not necessarily clean element life and better system
• Complimenting existing fluid. Most new fluids (right out protection. The first stage (inlet)
system filtration of the drum) are unfit for use filter captures larger particles,
due to high initial contamination while the second stage (outlet)
• Removing free and levels. Contamination, both filter captures finer particles
emulsified water from a particulate and water, may be or removes water. A rugged
system added to a new fluid during industrial quality gear pump gets
• For use with fluids such as processing, mixing, handling and the job done fast.
hydraulic, gear and lube oils storage.
Using a Parker portable filter
Water is removed by installing cart is the most economical way
Par-Gel™ elements in the outlet to protect your system from the
filter. Par-Gel™ elements are harm that can be caused by
made from a polymer which has contamination.
a very high affinity for free water.
• Two filters instead of one • Pump protection and long • Element cost savings and
w/ 2.5 times increased dirt element life trouble-free service
holding capacity
• Wide variety of particulate • Capable of getting a fluid to • Extends fluid life and system
elements available a desired cleanliness level performance
• Par-Gel™ water removal • Removes “free water” from a • Gets dirt and water out of
elements available system system with one process
• Two flow rates available: • Enables use in low or high • Matched to your needs
5 gpm or 10 gpm viscosity applications
• Eleven-foot hose and wand • Additional hardware not • Ready to use as received
assemblies included necessary
57
Portable Filter Carts
Applications
icountPD (Intelli-Cart™ option)
• Early warning LED or Service cover
Hose & wand digital display indicators • Top-accessible for
assembly for Low,Medium and High easy changing of
• Ready to use; no contamination levels elements
additional hardware • Self diagnostic software
needed
• Flexible hoses for
tight spots
• Kink-resistant hose
prevents pump
cavitation
Visual indicator
• Tells you when to
change element
Electrical Cord
• 6 ft. with ON/OFF switch
• Optional 20 ft. cord with
retractable reel & mounted
power switch with thermal
overload protection
Dual filters
• Two stage, double
length filtration
for long element
life and pump
protection
110V/220V AC motor
Gear pump • Industrial brand
• Industrial quality name
• Quiet operation
Elements (not shown) • Dependable, long life
• Available for both particulate Drip tray
and Water Removal (WR) • Helps keep the work
in double length w/ 2.5 area safe and clean
times increased dirt holding
capacity
58
Portable Filter Carts
Specifications
Maximum Recommended Fluid Electrical Service Required: Construction:
Viscosity: 5MFP – 110/220 volts, 60/50 Cart frame – Steel
5MFP – 3000 SUS (647cSt) Hz, single phase, 8/4 amps Filter head – Aluminum
0.85 specific gravity 10MFP – 110/220 volts, 60/50 Filter bowl – Steel
10MFP – 500 SUS (108 cSt) Hz, single phase, 10/5 amps Hoses – PVC (Std.)
0.85 specific gravity EPDM (high temp option)
Electrical Motor: Wands – PVC (Std.)
Visual Indicator (outlet filter): 5MFP – ½ hp @ 1725 rpm, Steel tube (high temp
Visual differential type Open, Drip Proof option)
3-band (clean, change, bypass) 10MFP – ¾ hp @ 3450 rpm,
Open, Drip Proof Weight:
Thermal overload protection 110 lbs. (45.4kg)
Filter Bypass Valve Settings
(Integral to Element):
Inlet – 3 psid (0.2 bar)
Outlet – 35 psid (2.4 bar)
Operating Temperature:
Seal option “B” (standard)
-40°F to +150°F (-40°C to +66°C)
Dimensions:
A = Height: 1034mm (40.7 in.)
B = Width: 648mm (25.5 in.)
C = Depth: 503mm (19.8 in.)
New feature!
Intelli-Cart™
Parker is pleased to announce its
R&D effort to offer a diagnostic filter
cart - the Intelli-Cart. The icountPD
particle detector, the most up-to-date
technology in solid particle detection,
A can be mounted to the standard
frame of the filter cart for enhanced
monitoring of your hydraulic system.
The icountPD, coupled with the filter
cart is a cost effective solution to fluid
management and contamination
control. Ask your sales representative
today for more information.
B
59
Typical Fluid Cleanliness Level Filter Cart Performance
Requirements Fluid cleanliness levels are a function of initial
contamination levels, contamination ingression rates,
Many manufacturers of hydraulic components reservoir size and filter element efficiency. The chart
have established fluid cleanliness levels for their below lists approximate time requirements to achieve
components. Using a portable filter cart can be certain cleanliness levels based on the assumptions
a very effective way to reach and maintain these noted.
cleanliness levels.
Reservoir Time Projected
Component ISO Cleanliness Level Capacity Required Cleanliness
Servo control valves 16/14/11 (Gallons) (Hours) Level (ISO)
Proportional valves 17/15/12 50 0.5 20/18/15
Vane and piston 50 1.0 17/15/12
pumps/motors 18/16/13
50 2.5 16/14/11
Directional and pressure
100 1.5 18/16/13
control valves 18/16/13
100 2.5 17/15/12
Gear pumps/motors 19/17/14
100 4.0 16/14/11
Flow control valves
cylinders 20/18/15 200 2.5 19/17/14
New fluid 20/18/15 200 3.5 18/16/13
200 5.0 17/15/12
Notes:
Filter Cart Element The results in the chart are based on the following assumption:
Notes:
1. Par-Gel™ elements are designed to remove “free wa-
2 50.0 ter”, which is defined as water that is above a particular
fluid’s saturation level.
0 4 8 12 16 20 2. Capacity is very dependent on flow rate and viscosity.
Micron Size (c) Not recommended with fluids in excess of 500 SUS.
60
Assembly and outlet filter elements 2. Remove tube wands from oil to
1. Install hoses to inlet and outlet MUST be replaced to prevent prevent siphoning.
filters by threading the hose end fluid from going through the 3. Loosen hex head screws on filter
with the straight thread o-ring bypass in the filters. cover. Turn cover to clear screws,
seal fitting into the filter flange. 6. The inlet filter element is remove cover.
2. Connect the PVC tube wands provided with a 3PSI by- 4. Pull filter element from the filter
to the swivel fitting on the hose pass spring, and prevents head.
end. When servicing the PVC the pump from cavitating if a) Replace the synthetic or
tube wand, do not over-torque the element is not changed. Microglass III elements. Verify
the metal fittings going into the The outlet filter element is correct element replacement.
PVC coupling. Over-torque will provided with a 35PSI bypass b) Wire mesh elements can be
result in cracking the coupling. spring to prevent excessive cleaned. Ultrasonic cleaners
Generally, 1/4 turn beyond hand- pressure which may be harm- provide best results.
tight is sufficient. ful to personnel or to the filter 5. Install element in filter housing.
3. The Intelli-Cart™ is shipped cart. Make sure element o-rings seat
with a bag that contains user properly into the head, making
manuals, iPD programming disk, Warning: The filter bypass sure that the notch on the
and accessory parts. spring acts as a relief valve element lines up with the notch in
4. The iPD is shipped with the for the pump. Do not restrict the head.
factory default setting. Users can the outlet hose with a shut-off 6. Inspect the cover o-ring and
reprogram the iPD with the cable valve which will defeat the replace if necessary.
located in the attached bag, the function of the bypass valve, 7. Replace cover and tighten hex
program disk and the iPD owners causing excessive pressure, head screws until they are snug.
manual. which may be harmful to per- Do not over-torque (16 - 19
sonnel or to the filter cart. Ft. Lbs.) these screws. Do not
Operating Instructions interchange the inlet filter cover
7. The cleanliness indicator with the outlet filter cover. (The
1. Insert the inlet wand assembly works on differential pressure inlet filter has a “RFP” prefix, the
into the supply fluid receptacle and will indicate the condition outlet filter has a “ILP” prefix).
(drum/reservoir). The RFP filter is of the element (CLEAN, 8. Contact the HFD service
the inlet filter. CHANGE, or BYPASS). department at 419-644-0259
2. Insert the outlet wand assembly regarding iPD calibration.
into the clean fluid receptacle NOTE: The filter cart must be 9. iPD removal: remove oil lines from
(drum/reservoir). The ILP fIlter is in operation for the indicator to the iPD at the two fittings closest
the outlet filter. read properly. to the iPD. Disconnect the two
3. Verify that the ON/OFF switch is cables from the iPD. Remove iPD
OFF and plug the cord into the Maintenance Instructions from cart via two screws. The
proper grounded power source cart can be used without the iPD
(3 wire). 1. Turn switch to OFF position
and unplug cord from as long as the sample hoses are
4. Turn switch to ON position and removed from the System 20.
check outlet wand for oil flow. electrical outlet.
Protect sampling connectors from
Allow 30 to 60 seconds for contamination.
filters to fill with oil. If repeated
attempts to obtain oil flow fail, Trouble Shooting
check pump inlet fittings for Problem Cause Solution
tightness, remove inlet filter Does not start ON/OFF Switch Turn switch ON, replace switch if defective
access cover and verify the No electrical power Plug in cart
cover sealing o-ring is in place. Defective motor Replace
For very viscous fluids it may be No oil flow or erratic Filter housing not filled with oil Allow pump to run 30 to 60 seconds
pump noise Suction leak Check tightness of inlet fittings
necessary to pour 1 or 2 quarts
of fluid into the RFP inlet filter Check o-ring in inlet filter cover for nicks
Kink or restriction in inlet hose
housing to prime pump initially.
Add 1 or 2 quarts of oil to inlet filter
5. The condition of the filter
Defective pump Replace pump
element should be monitored Indicator reads Element dirty Replace or clean elements (both filters)
by observing the cleanliness CHANGE or BYPASS Oil extremely cold or viscous Change element to coarser micron rating
indicator on the outlet filter. Indicator does not No outlet element Install element
When the indicator is in the seem to move 40 micron element installed in Check cart model number to verify correct
CHANGE position, both inlet outlet filter element. The inlet filter has a rating RFP
prefix; the outlet filter has an ILP prefix
61
Filter Cart Replacement Parts
18
19 21**
17 15 16
20**
14
13
11 10
1
12
9 2
7 3
6 4
5
Item No. Part No. Description Qty Item No. Part No. Description Qty
1 928690Frame 1 13 940978 Tube Fitting 1
1 941468Frame (Intelli-Cart™) 1 14 928623 Cord Reel 1
2 940980Pipe Reducer Fitting 1 15 940960 Inlet Filter – Nitrile 1
3 940979Tube Fitting 1 15 941024 Inlet Filter – Fluorocarbon 1
4 937526Suction Tube Assy. 1 16 928784 Tube Wand Assy. – Seal Option B 2
5 928652Adapter Fitting 1 17 940961 Outlet Filter – Nitrile 1
6 928731Pump 1 17 941025 Outlet Filter – Fluorocarbon 1
7 940977Adapter Fitting 1 18 928663 Hose Assy. – Seal Option B 2
8 928650Wheel 2 19 928651 Handle Grip 2
9 928653Axle 1 20 See Chart** Element, (1) Inlet & (1) Outlet 2
10 928678Motor 10MFP 1 21 See Chart** icountPD (Intelli-Cart™) 1
10 929692Motor 5MFP 1 B84654 icount Cable (Intelli-Cart™) 1
11 937527Discharge Tube Assy. 1 B84224 icount Hoses (Intelli-Cart™) 2
12 941467Discharge Tube Top (Intelli-Cart™) 1 2/2A40EG4M-S icount Fitting 1(Intelli-Cart™) 2
941466Discharge Tube Bottom (Intelli-Cart™) 1 EMA3/1/8ED icount Fitting 2 (Intelli-Cart™) 2
STI.0144.100 System 20 (Intelli-Cart™) 1 **Refer to chart on How to Order page.
3/8-8F40HG5S System 20 Fitting 1 (Intelli-Cart™) 2
12/8 F50X-S System 20 Fitting 2 (Intelli-Cart™) 2
62
Portable Filter Carts
How to Order
63
SMR Series
Submicronic Removal
Fluid Purification Systems
64
SMR Series
Applications
65
SMR Series
Balanced Charge Agglomeration (BCA™) - How the Technology
Works
2 Oppositely charged particles are mixed and are attracted to each other, forming
larger particle clusters.
• The particulate is effectively removed from the hydraulic or lubrication fluid by high
efficiency filters.
66
SMR Series
Features and Benefits
• Removal of Oxidation
Byproducts and Biological
Contamination
• OEM Approvals
67
SMR2
Element Performance
Efficiency Capacity
Efficiency % PSID BAR
Beta Rating
10000 100
6
2Q
80
5Q 2Q
10Q 5
1000 99.9 5Q
10Q
20Q
60 4
200 99.5
20Q
100 99.0 3
40
20 95.0 2
20
1
2 50.0
0 0
0 4 8 12 16 20 0 20 40 60 80 100 120
68
SMR2
Specifications
Fluid
Viscosity: 1,020 SUS (220 cSt) maximum
Maximum Pressure: 50/80 PSI (operating/static)
Minimum Fluid Temperature: 65° F (18° C)
Maximum Fluid Temperature: 200° F (93° C)
Minimum Fluid Flash Point: >140° F (60° C)
Power
Customer Provided
Voltage: 110VAC/1Ph/60Hz, 230VAC/3Ph/60Hz, 460VAC/3Ph/60Hz
Phase: 1/3
Frequency 60Hz
Motor
Power: 0.5 HP
Voltage/Ph/Freq: 0-230/460/3/variable
RPM: 0 to 2000
Pump
Positive Displacement - Variable Frequency Drive (VFD)
Design Flow Rate: 0.5 - 2.5 GPM
Parameter Settings
Parameter Default Minimum Maximum
Flow 2 GPM [7.58 LPM] 0.5 GPM [1.9 LPM] 2.5 GPM [9.45 LPM]
Shutdown Pressure 70 psi [4.82 bar] 0 psi/bar 75 psi [5.17 bar]
Max Operating Pressure 50 psi [3.4 bar] 0 psi/bar 60 psi [4.13 bar]
Min Operating Pressure 0 psi [0.0 bar] 0 psi/bar 5 psi [0.34 bar]
Maximum Temperature 200° F [93.3°C] 35° F [1.6°C] 200° F [93.3°C]
Minimum Temperature 35° F [1.5°C] 35° F [1.6°C] 200° F [93.3°C]
Upstream Filter Delta-P 15 psi [1.0 bar] 5 psi [0.34 bar] 25 psi [1.7 bar]
Downstream Filter Delta-P 10 psi [0.67 bar] 5 psi [0.34 bar] 25 psi [1.7 bar]
Auto-Restart after power loss OFF n/a n/a
Auto-Restart after temperature OFF n/a n/a
shutdown
US or Metric units US
69
SMR2
Parts List
70
SMR10
Element Performance
Efficiency Capacity
Filtration Ratio/ Efficiency % PSID
Beta Rating
10000 100
2Q
5Q
10Q 6
2Q 20Q
5Q 80
10Q
1000 99.9 5
60 4
200 99.5
20Q
100 99.0
3
40
20 95.0 2
20
1
2 50.0
0 0
0 4 8 12 16 20 0 50 100 150 200 250 300 350 400
71
SMR10
Specifications
Fluid
Viscosity: 1,020 SUS (220 cSt) maximum
Maximum Pressure: 50/80 PSI (operating/static)
Minimum Fluid Temperature: 65° F (18° C)
Maximum Fluid Temperature: 200° F (93° C)
Minimum Fluid Flash Point: >140° F (60° C)
Power
Customer Provided
Voltage: 110VAC/1Ph/60Hz, 230VAC/3Ph/60Hz,
460VAC/3Ph/60Hz
Phase: 1/3
Frequency 60Hz
Motor
Power: 0.5 HP
Voltage/Ph/Freq: 0-230/460/3/variable
RPM: 0 to 2000
Pump
Positive Displacement - Variable Frequency Drive (VFD)
Design Flow Rate: 2.5 - 10 GPM
Parameter Settings
Parameter Default Minimum Maximum
Flow 10 GPM [37.9 LPM] 2.5 GPM [9.45 LPM] 10 GPM [37.85 LPM]
Shutdown Pressure 70 psi [4.82 bar] 0 psi/bar 75 psi [5.17 bar]
Max Operating Pressure 50 psi [3.4 bar] 0 psi/bar 60 psi [4.13 bar]
Min Operating Pressure 0 psi [0.0 bar] 0 psi/bar 5 psi [0.34 bar]
Maximum Temperature 200°F [93.3°C] 35°F [1.6°C] 200°F [93.3°C]
Minimum Temperature 35°F [1.5°C] 35°F [1.6°C] 200°F [93.3°C]
Upstream Filter Delta-P 15 psi [1.0 bar] 5 psi [0.34 bar] 25 psi [1.7 bar]
Downstream Filter Delta-P 10 psi [0.67 bar] 5 psi [0.34 bar] 25 psi [1.7 bar]
Auto-Restart after power loss OFF n/a n/a
Auto-Restart after temperature OFF n/a n/a
shutdown
US or Metric units US
72
SMR10
Parts List
73
SMR Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9
SMR 2 460 20QE V M2 X N08 MS
BOX 1: Basic Assembly BOX 4: Element Media1 BOX 6: Indicator
Symbol Description Symbol Description Symbol Description
SMR Submicronic Filtration SMR2 P No Indicator
System 02QE Ecoglass III, 2 micron M2 Analog Visual Indicator
Note:
1. Outlet polishing filter is always fitted
with 02QE/02Q element.
74
Guardian®
Portable Filtration System
75
Ground Support
Hydraulic Service
76
Features Advantages Benefits
Lightweight, hand held, Easy to carry and fits One person
compact design (less easily on top of 55 operation, capable of
than 24 Ibs 16” X 8” ap- gallon drums. getting to hard to reach
proximate foot print). areas.
Flow rate to 4 gpm. Filters and transfers One step operation.
simultaneously.
Powerful pump/motor Handles fluids up to Reliable performance in
combination with Car- 16,000 SUS viscosity a wide variety of
boxylated Nitrile seals (11,000 SUS -24 VDC). operating conditions. Mobile
standard.
Built-in relief valve with Only filtered fluid 100% filtration ensured,
no downstream fluid reaches downstream even when unattended.
bypass. components.
Wide variety of filter High capacity 2 micron Maximizes
elements available. absolute disposable element life
microglass to 74 between changes.
micron cleanable wire
and water removal.
Clear, wire-reinforced 5’ No additional hardware Ready to use and easy
hose assemblies with required. to maneuver.
wand attachments.
Optional quick Fast, easy setup and Eliminates messy drips.
disconnect hose tear-down.
connections.
Heavy-duty ¼ HP, UL recognized and CSA Safe, reliable
115 VAC (230 VAC, 24 listed, with replaceable performance; field
VDC- optional) motor brushes. serviceable.
with thermal overload
protection. Industrial
Geroter pump with Dirt tolerant design with Pump reliability in highly
visible serviceable inlet added protection. contaminated fluids.
strainer.
Quiet operation. Less than 70dB noise Can be used most
level @ 3 feet. anywhere with
minimal disturbance.
Convenient Contains fluids when Clean and safe
inlet-to-outlet hose transporting. operation.
connection.
Low center of Guardian stability. Unattended
gravity. reliability.
Dual motor seals. Added motor protection. Longer motor life.
77
Guardian Series
Installation and Specification Data
Maximum Allowable Operating Operating Temperatures: Electrical Motor: ¼ hp@2500 rpm.
Pressure (MAOP): 50 psi (3.4 Unit: -15°F to 180°F (-26°C to 24 VDC; 10A max.
bar) 82°C) 110-120 VAC; 50/60 Hz; 3A max.
Flow Capacity: Up to 4 gpm Wand/Hose: 25°F to 120°F 220-240 VAC; 50/60 Hz; 1.5A max.
(15 lpm) (-4°C to 49°C) Thermal overload protected.
Visual Indicator: Differential Replaceable brushes (500 hours).
Maximum Recommended Fluid
Viscosity: (.85 specific gravity) pressure type, set at 25 psid Weight: approximately 23 lbs. 5 oz.
110-120 VAC and Recommended Fluids: petroleum Materials:
220-240 VAC 16,000 SUS based oils, water emulsions, and Housing: cast aluminum
24VDC 11,000 SUS diesel fuels Cover: die cast aluminum
Warning: Explosion hazard. Do Integral Relief Valve: set at 50 psi Handle and Indicator: nylon
not pump flammable liquids such for motor protection. Wands and Hose: PVC
as gasoline, alcohol, solvents, etc. Fittings: brass
Noise Level: <70db at 3 ft. Seals: fluorocarbon/
carboxylated nitrile
On/off
switch
195
7.68
Inlet
50.8
2.00
Outlet Clean inlet strainer as required
78
Guardian Series
Element Performance
Time Averaged Dirt Efficiency
Media Filter Beta x/y/z =2/20/75 Capacity Beta at x
Code Media Where x/y/z is: (Grams) Rating Particle Size
74W Woven Wire 74 micron1 *
Bx = 2 50.0%
40W Woven Wire 40 micron1 * Bx = 20 95.0%
25W Woven Wire 25 micron1 * Bx = 75 98.7%
20C Cellulose 20 micron1 * Bx = 200 99.5%
10C Cellulose 5/8/16 4 Bx = 1000 99.9%
20Q Microglass III 7.1/13.7/17.3 16.2
10Q Microglass III 2.7/7.3/10.3 14.4
05Q Microglass III <2/2.1/4.0 14.9
02Q Microglass III <2/<2/<2 14.3
Multipass test run at 4 gpm to 35 psid
1
Reference ratings only. Not multipass tested due to coarseness.
* Not applicable
10000
Note 1: Guardian not
recommended for fluid
viscosities greater than
Viscosity (SUS)
16,000 SUS
(11,000 SUS;24VDC)
1000
Note 2: Flows based
on Guardian with no
element installed
100
10
Mining 0 1 2 3 4 5
Flow (GPM)
79
Guardian Operation Guardian Element Servicing
A. Remove all shipping plugs from the hoses and fittings. A. Flip the switch on the end of the unit to the “off” position
B. Connect the inlet and outlet hose assemblies to the unit. and disconnect the electrical plug.
C. Connect the wand assemblies, if required. B. Rotate the cover counter-clockwise and remove.
D. Place the inlet hose wand assembly into the fluid to be C. Remove the element from the housing. Discard all
filtered and/or transferred. disposable elements. These elements are not cleanable,
E. Place the outlet hose/wand assembly into the container D. Place the new element In the housing, fitting the o-ring
where the fluid discharge is desired. neck into the large hole at the bottom.
F. Plug in the unit. E. Inspect the cover o-ring and replace if necessary.
G. Flip the switch on the end of the unit to the “on” posi- F. Replace the cover and hand-tighten.
tion. NOTE 1: It is recommended that the Guardian be
NOTE: For no-mess transportation, the inlet and outlet cleaned and flushed between uses with
hose assemblies can be screwed together by dissimilar fluids to prevent fluid mixing.
removing the wand assembly. NOTE 2: Motor brushes may require changeout
every 500 service hours
Troubleshooting Guide
Problem Cause Solution
Does not start. ON/OFF switch. Turn switch on, replace switch if defective.
No electrical power. Plug in Guradian, check for tripped circuit breakers, check for
Rectifier. blown fuses.
Motor overheats (160°F). Replace if defective.
Defective motor. Allow motor to cool, thernal overload will automatically reset.
Replace motor.
Does not start or errattic Worn motor brushes. Replace motor brushes.
motor noise.
Intermittent start.stop oera- High viscosity fluids. High viscosity fluids can cause the motor to overheat and cycle
tion. Worn motor brushes. intermittently.
Defective motor. Replace motor grushes.
Replace motor.
Hot motor. Pumping under heavy load. It is normal, under a heavy pumping load for the motor to reach
Defective motor. 160°F.
Replace motor if shell temperature reaches greater than 170°F.
No flow or erratic pump Filter housing not filled with oil. Allow Guardian to run a few seconds.
noise. Suction leak. Check tghtness of inlet fittings and hoses. Check gaskets are
Obstructed outlet. in place and are not damaged. Kink or restriction in the inlet
Element dirty. hose.
Sheared pump key. Clear outlet.
Defective Guardian. Replace or clean element.
Replace woodruff key.
Replace unit.
No flow, erratic pump noise, Gears binding. Disassemble Guardian and throroughly clean the gear set.
motor overheats. Always use the inlet strainer provided to protect the unit.
Replace defective gears.
No suction. Plugged strainer. Clean or replace the inlet strainer as required.
Clean relief valve. Check for damaged internal o-rings.
Reduced oil flow. High viscosity fluids. High viscosity fluids can cause reduced flow, which is normal.
Element dirty. Replace or clean element.
Relief valve sticks or is lodged Clean releif valve or replace if defective.
open. Clear the hose obstruction.
Partially obstructed inlet or Check tightness of inlet fittings and hose.
outlet hose. Replace gear set.
Suction leak.
Worn gears.
Indicator moves to RED Element dirty. Replace or clean element.
Area. Oil extremely cold or viscous. Change element to coarser micron rating.
Obstruced outlet. Clear outlet obstruction.
Defective indicator. Replace indicator.
Indicator dows not seem to No element. Install element.
move. Defective indicator. Replace indicator.
Joses discolor or are hard. Fluid compatibility. Certain fluids, over time, will cause the hoses to discolor. This
does not impair their performance. But, some fluids will cause
the hoses to become brittle, requiring replacement.
Oil formation under unit. Defective shaft seal. Replace the motor shaft seal.
80
Guardian Replacement Parts
Replacement Elements
Media Part No. Box Qty.
02Q 933467Q 2
05Q 932018Q 2
10Q 932017Q 2
20Q 933468Q 2
10C 932016 2
20C 932020 2
25W 922627 1
40W 922628 1
74W 922626 1
WR 932019 2
Parts List
1. Label. . . . . . . . . . . . . . Consult Factory 12. Geroter Ring . . . . . . . . . . . . . . .931903 25. Rubber Bumpers (2) . . . . . . . .931888
2. Motor, 110-120 VAC . . . . . . . . .931913 13. Outlet Plate . . . . . . . . . . . . . . . .931900 26. SHCS(2), ¼-20 x ½ . . . . . . . . . .902907
220-440 VAC . . . . . . . . . .932381 14. Geroter O-ring . . . . . . . . . . . . .V72135 27. Brass Fitting (2) . . . . . . . . . . . .931928
24 VDC. . . . . . . . . . . . . . .932759 15. Brass Pipe Plug (2) ½-14. . . . .931920 28. Gasket (4). . . . . . . . . . . . . . . . . .931956
3. SHCS(4),¼-20x1 . . . . . . . . . . . .902734 16. RoIl Pin 1/8 x 5/8 . . . . . . . . . . . . .903426 29. Inlet Screen . . . . . . . . . . . . . . . .931927
4. Adapter Plate . . . . . . . . . . . . . .931890 17. SHCS (2), ¼-20 x 5/8 . . . . . . . . .931889 30. Inlet Hose Assembly . . . . . . . .931936
5. Housing O-Ring . . . . . . . . . . . .V72041 18. Handle . . . . . . . . . . . . . . . . . . . .931897 31. Outlet Hose Assembly . . . . . . .931937
6. Polypak Seal . . . . . . . . . . . . . . .931921 19. Cover . . . . . . . . . . . . . . . . . . . . .931892 32. Wand Crevice Assembly . . . . .931965
7. Shadow Plate . . . . . . . . . . . . . .931899 20. Cover O-Ring. . . . . . . . . . . . . . .V72237 33. Wand Adapter Assembly . . . . .931966
8. Woodruff Key 1/8 x 3/8 . . . . . . . . .931877 21. Element . . . . . . . . . . . . . . . . . . . . . . . . . 34. Washer (2) . . . . . . . . . . . . . . . . .926106
9. SHCS(4), ¼-20 x ¾ . . . . . . . . . .902679 22. Relief Valve . . . . . . . . . . . . . . . .928981 35. Quick Disconnect Kit . . . . . . . .932097
10. Roll Pin 1/8 x ¾ . . . . . . . . . . . . . .903630 23. Indicator Kit. . . . . . . . . . . . . . . .927422 (Not Shown)
11. Geroter Set . . . . . . . . . . . . . . . .931873 24. Housing . . . . . . . . . . . . . . . . . . .931838 36. Washer. . . . . . . . . . . . . . . . . . . .932085
37. Brush Kit (110/120) . . . . . . . . .934329
(220/240 VAC) . . . . .934327
NOTE: SHCS denotes “socket head cap screw” (24 VDC) . . . . . . . . . .932761
Seal Kit . . . . . . . . . . . . . . . . . . . . . .932263
Bowl Extension Kit . . . . . . . . . . . .932081
81
Guardian Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
82
Portable Purification Systems
Models PVS 185, 600, 1200, 1800, 2700
83
PVS Series
Principles of Operation
Contaminated oil is drawn into the Parker Typical Saturation Points
Portable Purification System by a vacuum of 25
In/Hg. The oil passes through the in-line low
watt density heater where the oil is heated to an Fluid Type PPM %
optimum temperature of 150° F (66°C).
The oil then enters the distillation column where Hydraulic Fluid 300 .03%
it is exposed to the vacuum through the use of
special dispersal elements. This increases the Lubrication Fluid 400 .04%
exposed surface area of the oil and converts the
water to vapor form, which is then drawn through Transformer Fluid 50 .005%
the condenser by the vacuum pump.
The water-free oil falls to the bottom of the column
and is removed by a heavy duty lube oil pump.
This pump forces the dry oil through a final
particulate removal filter. Clean oil passes out
of the unit, back to the reservoir — and into the
system.
84
PVS Series
Applications Markets
• Hydraulic Systems • Power Generation
• Lubrication Systems • Pulp and Paper
• Primary Metals
• Turbine Oil
• Mining
• Transformer Oil • Plastic Injection
• New Oil (oil storage) Molding
• Oil Exploration
• Seal Oil
• Petrochemical
• Explosion Proof • Automotive
Environments NEMA 7 Explosion Proof • Aerospace
• Refineries
• Transportation
Standard Features Advantages Benefits
Variable flow circuit • Allows oil to heat more quickly so • Time savings
water is removed faster
Moisture sensor • Real-time water content • At-a-glance visual confirmation
indication in % saturation
Automatic operation • Unattended use • Reduces labor costs
• Designed for 24/7 operation • Increases operation time
316 Stainless steel used for • No corrosion • Product reliability
primary wetted surfaces
Ecoglass particulate element • Coreless, non-metallic • Environmentally friendly, easy
construction disposal
Clear plexiglass covers on the • See the vacuum dehydration • Visual verification of water
condensate tank and vacuum process work removal
chamber
Desiccant breather • Insures dry, clean intake air • More efficient operation
Reverse phase switch • Enables easy changing of • Ease of maintenance
motor rotation if out-of-phase • Prevents incorrect rotation
Condensate holding tank with • Large volume for infrequent • Reduces maintenance costs
optional auto drain servicing intervals
Programmable thermostat • Maintains oil within 1°F • Unattended operation
• Prevents overheating the oil
Forklift guides and lifting eyes • Provides safe and secure • Employee safety
method of lifting the unit
Coalescing or packed tower oil • Flexibility with various fluid • Greater efficiency in removing
dispersal elements viscosities moisture
85
PVS Series
Vacuum Dehydration Performance
Potential Typical Performance
Contaminant PVS Performance Tank Size 60 Gallons (227 liters)
ISO Cleanliness Code* Run Time 62 minutes
Solid particulate
14/13/10 Attainable
Parker Model PVS 600 (10 GPM)
Removes 100% of free water,
Water Water Content (ppm) Start: 10,000 PPM (1.0%)
90% of dissolved water
Stop: 50 PPM (0.005%)
Removes 100% of free air
Contamination Level Start: ISO 21/18/16
Air/Gases and gases, 90% of dissolved
Stop: ISO 16/14/11
air and gases
*When utilizing 02Q media.
86
PVS 185 Series
Specifications
Flow rate 5 gpm (18.9 lpm)
Dimensions 65" H x 33” W x 48” L
(1651mm x 838mm x 1219mm)
Weight 650 lbs. (295 kg)
Seal material Fluorocarbon (EPR optional)
Condensate tank 4.1 gal (15.5 ltrs)
Dispersal elements 1
Minimum operating capacity 5 gal (18.9 ltrs)
Vacuum (max) 25 In/Hg
Viscosity (max) 500 sus (108 cSt)-Disposable
2150 sus (460 cSt)-Packed Tower
Outlet pressure (max) 60 psi (4.1 bar)
Ports 3/4" JIC (male) inlet
3/4" JIC (male) outlet
FLA (full load amps) 15-41 amps
(Depending on options & voltages)
Shipping Weight 1400 lbs. (635 kg) maximum
Shipping Dimensions 70” H x 48” W x 60” L
(1778mm x 1219mm x 1524mm)
Note: Dimensions and weights are approximate and for reference only.
Elements
Standard Coreless
Particulate (80CN-2) PVS 185 Flow Diagram
02QE (2 micron) 936716Q
05QE (5 micron) 936717Q
10QE (10 micron) 936718Q
20QE (20 micron) 936719Q
Optional Coreless
Particulate (IL8-3)
02QE (2 micron) 933734Q
05QE (5 micron) 933612Q
10QE (10 micron) 933735Q
20QE (20 micron) 933736Q
Dispersal
Disposable
933180
(Coalescing)
Heater
Packed tower
933553
(Cleanable)
87
PVS 600 Series
Specifications
Flow rate 10 gpm (37.9 lpm)
Dimensions 65" H x 33” W x 48” L
(1651mm x 838mm x 1219mm)
Weight 900 lbs. (408.2 kg)
Seal material Fluorocarbon (EPR optional)
Condensate tank 4.1 gal (15.5 ltrs)
Dispersal elements 2
Minimum operating capacity 6 gal (22.7 ltrs)
Vacuum (max) 25 In/Hg
Viscosity (max) 500 sus (108 cSt)-Disposable
2150 sus (460 cSt)-Packed Tower
Outlet pressure (max) 60 psi (4.1 bar)
Ports 1" JIC (male) inlet
1" JIC (male) outlet
FLA (full load amps) 24-38 amps
(Depending on options & voltages)
Shipping Weight 1500 lbs. (680 kg) maximum
Shipping Dimensions 70” H x 48” W x 60” L
(1778mm x 1219mm x 1524mm)
Note: Dimensions and weights are approximate and for reference only.
Replacement
Elements
UL and CUL Marked
Standard Coreless
Particulate (80CN-2)
02QE (2 micron)
05QE (5 micron)
936716Q
936717Q
PVS 600 Flow Diagram
10QE (10 micron) 936718Q
20QE (20 micron) 936719Q
Optional Coreless
Particulate (IL8-3)
02QE (2 micron) 933734Q
05QE (5 micron) 933612Q
10QE (10 micron) 933735Q
20QE (20 micron) 933736Q
Dispersal
Disposable
933180
(Coalescing)
Packed tower
933553
(Cleanable)
88
PVS 1200 Series
Specifications
Flow rate 20 gpm (75.7 lpm)
Dimensions 65" H x 44” W x 61” L
(1651mm x 1118mm x 1549mm)
Weight 1550 lbs. (703 kg)
Seal material Fluorocarbon (EPR optional)
Condensate tank 8.3 gal (31.4 ltrs)
Dispersal elements 4
Minimum operating capacity 11 gal (41.6 ltrs)
Vacuum (max) 25 In/Hg
Viscosity (max) 500 sus (108 cSt)-Disposable
2150 sus (460 cSt)-Packed Tower
Outlet pressure (max) 60 psi (4.1 bar)
Ports 1½" JIC (male) inlet
1" JIC (male) outlet
FLA (full load amps) 30-48 amps
(Depending on options & voltages)
Shipping Weight 2300 lbs. (1043 kg) maximum
Shipping Dimensions 70” H x 48” W x 65” L
(1778mm x 1651mm x 1524mm)
Note: Dimensions and weights are approximate and for reference only. UL and CUL Marked
Replacement
Elements
Standard Coreless
Particulate (IL8-3)
02QE (2 micron) 933734Q
05QE (5 micron) 933612Q PVS 1200 Flow Diagram
10QE (10 micron) 933735Q
20QE (20 micron) 933736Q
Dispersal
Disposable
933180
(Coalescing)
Packed tower
933553
(Cleanable)
89
PVS 1800 Series
Specifications
Flow rate 30 gpm (113.6 lpm)
Replacement
Dimensions 68” H x 42” W x 75” L Elements
(1727mm x 1067mm x 1905mm) Standard Coreless
Particulate (IL8-3)
Weight 2550 lbs. (1157 kg)
02QE (2 micron) 933734Q
Seal material Fluorocarbon (EPR optional)
05QE (5 micron) 933612Q
Condensate tank 8.3 gal (31.4 ltrs) 10QE (10 micron) 933735Q
Dispersal elements 8 20QE (20 micron) 933736Q
Minimum operating capacity 18 gal ( 68.1 ltrs) Dispersal
Vacuum (max) 25 In/Hg Disposable
933180
(Coalescing)
Viscosity (max) 500 sus (108 cSt)-Disposable
Packed tower
2150 sus (460 cSt)-Packed Tower 933553
(Cleanable)
Outlet pressure (max) 60 psi (4.1 bar)
Ports 2" JIC (male) inlet
1.5" JIC (male) outlet
FLA (full load amps) 40-65 amps @ 460 V/60hz
Shipping Weight 3000 lbs. (1361 kg) maximum
Shipping Dimensions 70” H x 48” W x 80” L
(1778mm x 1219mm x 2032mm)
Note: Dimensions and weights are approximate and for reference only.
90
PVS 2700 Series
Specifications
Flow rate 45 gpm (170.3 lpm)
Replacement
Dimensions 65" H x 42” W x 75” L Elements
(1727mm x 1067mm x 1905mm) Standard Coreless
Particulate (IL8-3)
Weight 2550 lbs. (1157 kg)
02QE (2 micron) 933734Q
Seal material Fluorocarbon (EPR optional) 05QE (5 micron) 933612Q
Condensate tank 8.3 gal (31.4 ltrs) 10QE (10 micron) 933735Q
Dispersal elements 8 20QE (20 micron) 933736Q
Minimum operating capacity 18 gal ( 68.1 ltrs) Dispersal
Vacuum (max) 25 In/Hg Disposable
933180
(Coalescing)
Viscosity (max) 500 sus (108 cSt)-Disposable
Packed tower
2150 sus (460 cSt)-Packed Tower 933553
(Cleanable)
Outlet pressure (max) 60 psi (4.1 bar)
Ports 3" JIC (male) inlet
2" JIC (male) outlet
FLA (full load amps) 50-70 amps @ 460 V/60hz
Shipping Weight 3000 lbs. (1361 kg) maximum
Shipping Dimensions 70” H x 48” W x 80” L
(1778mm x 1219mm x 2032mm)
Note: Dimensions and weights are approximate and for reference only.
91
PVS Series
Specification Worksheet
1. Application: ________________________________________________________________________________
92
PVS Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 1 STD BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9
ACD
PVS 600 460 DS D 10QE 12 AC DFL CR
93
Stationary Offline System
SOS for Indoor/Outdoor Fluid Filtration Needs
94
Stationary Offline System
Performance Data
Efficiency
Beta Rating Efficiency %
10000
Parker’s new
patented 2Q 5Q
10Q
Moduflow™ Plus 1000
99.9
element was
designed with 200
99.5
built-in diverter 100 99.0
cone and bypass
valve, to meet
20 95.0
your application
needs.
2 50.0
0 4 8 12 16 20
Micron Size (c)
Capacity
Applications PSID BAR
• General Industrial
30
• Power Generation 2.0
LPM
Flow vs Pressure Loss LPM
0.0 5.0 10.0 15.0 0.0 5.0 10.0 15.0
5 1.0
150SUS 150SUS
Empty Housing 0.06
0.30
4 0.8
0.25 0.05
3 0.6 0.04
0.20
PSID
BAR
PSID
BAR
0.15 0.03
2 0.4
2Q 0.10 0.02
1 0.2
5Q 0.01
0.05
10Q
0 0.00 0.0 0.00
0 1 2 3 4 5 0 1 2 3 4 5
GPM GPM
95
Stationary Offline System
Specifications 02%3352%
37)4#(
7!9
Flow rate: 5 gpm "!,, 6!,6%
phase, 60 Hz
7!9
"!,, 6!,6%
'0-
Electrical motor: ½ HP @ 1725 rpm w/ thermal
overload protection.
%.#,/352%
Filter bypass alarm: Red strobe light indicates at
20 psid filter element pressure 2.43
2“ PIPE CLAMP
29.35
MOUNT
23.09
AIR VENTS
14.31
1.91
13.90
23.30
17.18 17.01
5.68
.48
OUTLET
3/4” NPT
2-WAY
BALL VALVE
The Moduflow™ Plus filter 25.00
23.00
96
Stationary Offline System
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
BOX 4: Seals
Symbol Description
B Nitrile (NBR)
V Fluorocarbon (FKM)
Replacement Elements
Nitrile Seals Fluorocarbon Seals
Media Part Number Part Number
02Q 937393Q 937401Q
05Q 937394Q 937402Q
10Q 937395Q 937403Q
WR 940733 —
97
Environmental Air Filters
Reservoir Equipment
Automotive Filter Catalog
98
EAB Series
Reservoir Equipment
0 53 105 158 211 263 316 368 421 474 530 0 53 105 158 211 263 316 368 421 474 530
10 1.45 4 0.58
9 1.305
GE12
8 1.6
3 0.435
7 1.015
Δp (PSID)
Δp (PSID)
Δp (kPa)
Δp (kPa)
6 0.87
5
GE16 0.725 0.29
2
4 0.58
C015
3 0.435 Q010
HC73 1 0.145
2 0.29
1 0.145 P020
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 200 400 600 800 1000 1200 1400 1600 1800 2000
Flow (l/min) Flow (l/min)
0 53 105 158 211 263 316 368 421 474 530 0 53 105 158 211 263 316 368 421 474 530
10 1.45 4 0.58
9 1.305
8 1.6
GE12 3 0.435
7 1.015
Δp (PSID)
Δp (PSID)
Δp (kPa)
Δp (kPa)
6 0.87
5 0.725 2 0.29
GE16
4 0.58 C015
3 0.435
1 0.145
2 0.29 Q010
HC73
1 0.145 P020
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 200 400 600 800 1000 1200 1400 1600 1800 2000
Flow (l/min) Flow (l/min)
99
EAB Series
Specifications
EAB10 EAB20
Optional indicator Ø114
Ø114
Optional indicator
68
102
Holes for locking
43
max max
* Optional mounting holes Optional overpressure
valve
Ø73 Ø90
* Optional mounting holes
G3/4 Ø73 Ø90
G3/4 or G1 G3/4
* Strainer
G3/4 or G1
* Strainer
* Gasket
* Gasket
94
94
Mounting Code
NOTICE! 6 mounting holes HC73
Air filters are an essential G1 external GE16
part of the system and G3/4 external GE12
G3/4 internal GS12
the element needs to be
replaced regularly.
6 hole fixing mounting
dimensions
6 x 60° Ø4 or M5
55
73
100
EAB Series
How to Order
Product configurator
Product number Media options Mounting options Overpressure valve options Indicator options
EAB20 P020 2μ abs polyester HC73 6 hole fixing No overpressure valve No indicator
Replacement elements
Product number Media options
101
ABL Series
Reservoir Equipment
Typical Applications
The Parker Filtration
ABL-2 Series Air Filters.
Saw mills
Agricultural machines
Articulated dump trucks
Forestry equipment
Wheeled loaders
Lubricating systems
Excavators
Industrial power units
Mobile cranes
Technical Data
Assembly: Flow fatigue characteristics: Options:
Tank top mounted. Filter media is supported so • Adaptor with filter connection.
Connections: that the optimal fatigue life is • Single adaptor.
Threads G11/4 (ISO 228), 11/2” achieved. • Breather with integrated
(UN-16-2B). Vacuum indicator: pressure relieve valve for
ABL-2 0.04 bar. Visual with latch pressurised
Seal material:
tank on request only.
Seals integrated in LEIF® element. out memory.
LEIF® elements can be used for
Operating temperature range: Breather housing:
hydraulic fluids only. For other
-20°C (-4F), +80°C (176F) High impact strength composite.
fluids contact Parker Filtration.
Filtration media: Filter element:
3 micron. LEIF® element.
ABL2
Flow (US GPM)
2 29
Δp (PSID)
Δp (mbar)
1.5 21.8
1 14.5
0.5 7.3
0 0
0 500 1000 1500 2000 2500
Flow (l/min)
102
ABL Series
Specifications
ABL-2
NOTICE!
Air filters are an essential
35.5
2
163
Top view
25
11/2-16UN-2B
(Optional: ISO 228-G11/4)
SLW46
Ø127
A
Adaptor single Adaptor with filler connection
A
/2” BSP
95
1
45
80
6xØ7(PCDØ73)
2
6xØ7(PCDØ73)
Ø85
400
2
Ø85
103
ABL Series
How to Order
Product configurator
Product number Mounting options Filtration (3μm) Indicators Options
211U
ABL2 2000 l/min 11/2 UN-16-2B QXWL13 ABL2 Only V Visual SNG Vacuum/Pressure Gauge
Product configurator
Product number Mounting options Options
Adaptor ABL G114 ISO 228 - G11/4 (BSP) SNG Single Adaptor
Replacement elements
Part number Supercedes Description
QXWL13 QXWL1-3 3μ
Note 1: Part numbers featured with bold highlighted codes will
ensure a ‘standard’ product selection.
Note 2: Alternate displayed part number selection will require you
to contact Parker Filtration for availability.
104
ABL Series
Reservoir Equipment
Notes
105
AB Series
Reservoir Equipment
(in Microns).
(Air filtration level should
be the same or finer thant
the filtration level of your
Hydraulic system.)
D) Select proper can size from
the graph below. (Initial clean CAN SIZE
11.5 [292.1]
pressure drop should not
exceed 6 inches of water.)
CAN SIZE
7.5 [190.5]
5X 7 5X 7
3 10
MICRON MICRON
ΔP in inches of water
5 X 11
10
MICRON
PUSH BUTTON TO RESET
MEMORY
FILTER
AIR FILTER GAUGE
FILTER MINDER
INDICATOR
22
25 CHANGE
11
15
8
SEE ORDER
4.20 [106.7] CODE
4.92[125.0]
106
AB Series
How to Order
Select the desired symbol (in the correct position) to construct a model code.
Example:
107
LaserCM
Portable Particle Counter
Fluid Condition Monitoring
108
LaserCM
Portable Particle Counter
Typical Applications
Construction machinery
Industrial plant
Hydraulic equipment & system
manufacturers
Research & testing institutes
Offshore & power generation
Marine
Military equipment Parker LaserCM Portable Particle Counter.
applications With 15 years experience in manufacturing the world’s best selling ‘white
light’ portable particle counter – CM20, the progression to the LaserCM with
its opto-mechanical, continuous wave single point source laser (SPSL) is
both a natural and customer driven development.
109
LaserCM
Specifications
110
LaserCM
Specifications
Dimensions in mm (ins)
28 (1.1)
Fluorocarbon seals
Perfluoroelastomer seals
Nylon hoses (kevlar braided microbore)
249 (9.8)
Stainless steel armoured hose ends
1.2m (4ft) fluid connection hose
System 20 sensors. Higher with single point sampler
Rechargeable battery pack
12Vdc power supply 240 (9.45)
Fast blow fuse
Unique optical scanning system
Bonded glass optical window enclosed in SS plate
Micron channels analysis (2μ,5μ,15μ,25μ,50μ & 100μ)
Analysis range ISO 7 to 22 incl. (NAS 0 to 12)
32 character dot matrix LCD. Alpha numeric keypad
Data retrieval
Calibration to ISO standards*
Viscosity range 2 to 100 cSt. 500 cSt.with SPS
Operating temp.+5 to +80°C (+41 to +176°C)
Commissioning Kit
Ambient temp.+5 to +40°C (+41 to +104°C)
2 minute test completion time Limit socket, fuse Datum &
Power supply & jack plug Screwdriver cable assy
Memory store – 300 test memory
12Vdc regulated power supply input
Battery operated 6 x 1.5 D cells
Phosphate Ester group compatibility
Mineral oil & petroleum based fluid compatibility
Up to 420 bar (6000 psi)
Integral 16 column printer
RS232 computer interface
Astra board case weight – Kg (lbs) 5 (11lbs) 5 (11lbs)
Unit weight – Kg (lbs) 8 (17.6lbs) 8 (17.6lbs)
DATUM software and cable link pack
Weather protector cover
CE certified
Auto logging
*Note: In compliance with international standards, all Parker portable particle counters Batteries &
can meet the ISO Medium test dust standards. The LaserCM’s, in addition to the Instruction Power lead,
printer ribbon, printer reel
complete range of Condition Monitoring products, are capable of achieving certification Re-chargeable manual & bar
to ISO 4406:1999 and with traceability to ISO 11171 for SRM 2806, via ISO 11943. battery pack code software bar code pen &
weather cover
111
LaserCM
Operation
Operating the Parker LaserCM MTD (Medium Test Dust) having ACFTD MTD
is as simple as pressing the start a particle size distribution close 2μ 4μ (c)
button and turning the dial. The test to ACFTD was selected as a 5μ 6μ (c)
procedure is automatic and in the replacement. However, MTD 15μ 14μ (c)
case of the LaserCM takes no more produced results somewhat different 25μ 21μ (c)
than 2 minutes to complete. to ACFTD, so the NIST (National 50μ 38μ (c)
Institute of Standards & Technology) 100μ 70μ (c)
LaserCM makes the difference in undertook a project to certify the
MTD offers true traceability, improved
industry particle size distribution of ISO MTD.
particle size accuracy and better
Fully accredited to BS EN The result was particle sizes below batch to batch reproduction.
60825:1992 and IEC 60825-1 10μm were greater than previously
(safety of laser products) Standards, measured.
accredited to USA Standards and Particles sizes reported based on
achieving full ISO certification. NIST would be represented as μm
LaserCM offers users advanced laser
(c), with “c” referring to “certified”.
technology, a fast, dynamic and on-
Therefore the CM20 reported sizes
line 2 minute system test cycle. A
are as follows:
LaserCM Aggressive Fluids model is
also available, suitable for monitoring
corrosive fluids such as phosphate
ester based lubricants used in
commercial aviation.
MTD calibration
Laser CM20 MTD Calibration variants
LCM20
are certified via a primary ISO 11171 Using SPS
calibrated automatic particle counter.
All MTD Laser CM20’s achieve ISO
4406:1999 criteria, via ISO 11943.
Understanding MTD
ACFTD (Air Cleaner Fine Test Dust)
was formatted in the 1960’s, but
is no longer being produced. The
obsolescence of this dust has led to
the adoption of a new dust MTD.
112
LaserCM
Portable Particle Counter
113
LaserCM
Portable Particle Counter
LCM ‘Classic’
Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.
Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.
114
LaserCM
Portable Particle Counter
Notes
115
SPS
Single Point Sampler
Fluid Condition Monitoring
116
SPS Single Point Sampler
Features & Benefits
The Single Point Sampler provides in excess of 10ml/min when rate between upper and lower
a means to connect a CM20 or operating at any viscosity limits within a 100 bar (1450
H2Oil to a single pressure test within the product psi) inline pressure change
point and balance the differential specification Clear product identification to
pressure across the system, to Suitable for fluid temperatures ensure that it is connected
provide a controlled flow of oil from +5°C to +80°C (+41°F to correctly. (i.e. downstream of
into the monitor and away into +176°F) the CM20 or H2Oil)
a waste oil receptacle.
High quality polished finish.
Lightweight, compact and easy (stainless steel/ aircraft grade
to use design aluminum)
Fingertip operated control Capable of working with a
valve even at high pressures CM20 or H2Oil connected into
a system via the standard one
420 bar (6000 psi) rated
meter extension hose kit
Facilitates testing from large
Suitable for use with mineral
diameter pipes
and biodegradable oils,
Capability to test up to 500cSt petroleum based and
(106 SUS) viscosity oils phosphate ester fluids
(pressure permitting)
Phosphate ester version
Pressure compensated flow utilises the 5/8” BSF HSP style
control mechanism fitting
Possible to control the valve Designed so that it meets the
with the same level of lowest possible level of
accuracy whether the device is magnetic permeability
operating at high or low
Supplied with accessories kit
pressure
It will maintain the set flow
Capable of allowing a flow rate
Connection Instructions
LCM20 Only
System
1. Ensure valve is closed (A). Carry out flow test as shown in
2. Connect P2 on monitor (B) the manual. If test is showing
(F) (D)
to P2 on Single Point Sampler below t 3.6°C (38°F) then carry
Prs. (SPS) (C). out test as normal. If, however,
R
3. Connect drain line on test is above t 3.6°C (38°F) then
(A) SPS (D). increase oil flow by turning valve
Single
4. Connect P1 of monitor (E) (A) counterclockwise and then
point to the system (F). carry out flow test. Do this until
sampler 5. The SPS is ready to operate. t is below 3.6°C (38°F) and carry
6. Open valve (A) slowly until out test as normal once this is
(C)
the oil flows continuously achieved.
(E) P1 P2 (B)
from the drainline (D).
WARNING! Ensure that SPS
7. Switch on monitor and
valve is closed and monitor is
Monitor begin testing.
connected to the SPS BEFORE
connection to system.
117
SPS Single Point Sampler
Specifications
Specification
Fluid compatibility:
Mineral oil and petroleum based
fluids (standard version).
Aggressive fluid (dual seal
version) for other fluids consult
Parker Hannifin.
Seals: Dimensions in mm (ins)
123 (4.84)
Fluorocarbon or
Perfluoroelastomer.
Maximum working pressure:
53 (2.08)
420 bar (6000 psi).
Weight: SWP 420 bar
500 grams (18 oz) max. (Not
including hoses).
Packaging standard: 80.0 (3.15)
Cardboard carton (military usage
- plastic carry case).
Unit size:
45mm dia x 123mm long. (1.77 P2
dia x 4.84 long)
System connection:
Standard - minimess M16 (G1/4”
BSP) with cap, Ø45.0 (1.77)
Aggressive - 5/8” BSF HSP.
Operating temp range:
+5°C to +80°C (+41°F to +176°F).
Storage temperature range:
-26°C to +80°C (-15°F to +176°F).
Construction:
Body: Aluminum BS 1470
– pressurized end stainless steel.
Finish: Anodized blue
(standard version). Anodized
red (dual seal version).
Ordering Information
Standard products table
Product number Supercedes Description
118
System 20
Inline Sensors & Monitors/Fluid Condition Monitoring
Specification: Sensors
Construction:
Machined steel body. Electroless
nickel coating to minimum
depth of 40 microns
Brass/stainless steel internal
components
Installation Details
Flow capacities:
All suitable for use with oil, Size 0 Sensor
Dimensions in mm (ins)
water and water/oil emulsion
Size 0 – 6-25 l/min
(1.58-6.60 US GPM)
56 (2.2)
Pressure drop:
At max. rated flow, P is 1.1 bar
(16 psi) (mineral oil fluid at 30
ø41 (1.61)
Repeatability:
±1% FSD
73.5 (2.89)
Accuracy:
Flow ±2.5% full scale deflection
ø66.7 (2.62)
Weight:
Size 0 – 0.5kg (1.2lbs)
Size 1 – 3.5kg (8.4lbs) 231.3 (9.1) G11/4
Size 2 – 4.4kg (9lbs)
Aggressive Fluid Applications: Ordering Information
EPDM internal/external o-rings
Standard products table
and seals
Product number Supercedes Size Flow range Fluid type Port
I/min (USgpm) threads
STI0144100 STI.0144.100 0 6-25 (1.58-6.60) Mineral 3
/8
STI1144100 STI.1144.100 1 20-100 (5.28-26.4) Mineral 3
/4
STI2144100 STI.2144.100 2 80-380 (21.1-100) Mineral 11/4
STI0148100 STI.0148.100 0 6-25 (1.58-6.60) Aggressive 3
/8
STI1148100 STI.1148.100 1 20-100 (5.28-26.4) Aggressive 3
/4
STI2148100 STI.2148.100 2 80-380 (21.1-100) Aggressive 11/4
Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.
Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.
Note 3: Mobile Sensors are also available - Contact Parker
119
Icount PD
Online Particle Detector
120
Icount PD
The Icount Particle Detector from Parker represents the
most up-to-date technology in solid particle detection.
The design dynamics, attention The laser based, leading-edge
to detail, and small size of the technology is a cost effective market
permanently mounted, on-line solution to fluid management and
particle detector brings a truly contamination control.
innovative product to all industry.
Typical Applications
Mobile Equipment Power Generation
• Earth Moving Machinery • Wind Turbines
• Harvesting • Gearboxes
• Forestry • Lubrication Systems
• Agriculture
121
Icount PD
Features and Benefits
122
Icount PD
Dimensions / Installation Details
3.4”
(86)
1.9”
(49)
1.5”
(37)
0.6”
(16)
2.4” CTRS
(60 CTRS)
(182)
(110)
7.2”
4.3”
Pin #2
Pin #3
Pin #8
0.8”
(21) 2 mounting locations to suit M5 socket head cap screw.
(Screw pack supplied with Icount PD.)
2.0”
(52) Icount PD flange thickness = 0.4” (10mm)
6.1”
(155) Maximum Torque 5Nm
123
The following table can be used to equate the
Icount PD analogue output to an ISO or NAS Code.
Example: ISO code 12 is equal to 10mA.
Variable mA output settings
mA ISO mA NAS
ISO V MILLIAMP 4.0 0 4 00
20.0 4.5 1 5 0
18.0 5.0 2 6 1
16.0 5.5 3 7 2
Milliamp Output
14.0 6.0 4 8 3
12.0 6.5 5 9 4
10.0 7.0 6 10 5
8.0 7.5 7 11 6
6.0 8.0 8 12 7
4.0 8.5 9 13 8
2.0 9.0 10 14 9
0.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
9.5 11 15 10
ISO CODE 10.0 12 16 11
10.5 13 17 12
11.0 14 18 **
11.5 15 19 **
NAS V MILLIAMP 12.0 16 20 ERROR
20 12.5 17
18 13.0 18
16 13.5 19
4-20mA output settings
Milliamp Output
14 14.0 20
12 14.5 21 ISO Setting
10 15.0 ** mA current = (ISO Code / 2) +4
8 15.5 ** eg. 10mA = (ISO 12 / 2) +4
6 16.0 ** or
4 16.5 ** ISO Code = (mA current - 4) *2
2 17.0 ** eg. ISO 12 = (10mA -4) *2
0 17.5 ** NAS Setting
0 1 2 3 4 5 6 7 8 9 10 11 12 13
18.0 ** mA current = NAS Code +5
NAS CODE
18.5 ** eg. 15mA = NAS 10 +5
19.0 OVERRANGE or
19.5 OVERRANGE NAS Code = mA current -5
20.0 ERROR eg. NAS 10 = 15mA – 5
ISO Err 0 1 2 3 4 5 6 7 8 9 10 11 ▶▷
0-5Vdc <0.2 0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5
0-3Vdc <0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3
▷▶ ISO 12 13 14 15 16 17 18 19 20 21 22 Err
cont. 0-5Vdc 2.7 2.9 3.1 3.3 3.5 3.7 3.9 4.1 4.3 4.5 4.7 >4.8
0-3Vdc 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 >2.45
124
Icount PD
Display parameters (ISO 4406/NAS 1638)
Digital display indication
The digital display will show the The moisture sensor reading (%RH) • Solid digit(s) = code(s) that are
actual measured codes, the channel will also be shown – if the moisture at or below the set point (limit)
(μ) size and the user defineable sensor option is fitted. • Flashing digit(s) = code(s) that
limits. Note that the channel size are above the set point (limit)
and limits will alternate between The order of trigger for both of the
the two. codes and moisture sensor option The display for ISO4406 and
is: NAS1638 are identical. The ISO
display is shown below.
MTD calibrated
Error detection
In the unlikely event of an error
occurring, the digital display on
the Icount PD will simply display
the actual error code only – i.e.
ERROR 13 (a full list of error codes
LED display indication
is detailed in the Icount PD user
The LED display uses 3 sets of LED for manual).
the indication of ISO 4406 and NAS1638
code figures. Individual code lights will Moisture sensor output settings
trigger based on the customer settings. The moisture sensor is an option
that can be included when
The order of trigger will be:
specifying the Icount PD. The
moisture sensor reports on the
saturation levels of the fluid passing
• Solid green = one ISO code, or better, below the set
through the Icount PD sensing
point (limit)
cell. The output is a linear scale,
• Blinking green = ISO code at the set point (limit) reporting within the range of 5%
• Solid red = one ISO code above the set point (limit) saturation to 100% saturation.
• Blinking red = two ISO codes, or more, above the set
Saturation 4-20mA 0-3Vdc 0-5Vdc
point (limit)
5% 4.8 0.15 0.25
25% 8 0.75 1.25
50% 12 1.50 2.50
75% 16 2.25 3.75
100% 20 3.00 5.00
125
Icount PD
Auxilliary Flow Device
The pressure compensated, flow This flow control device Example:
control device (Part Number automatically compensates for If the fluid you wish to analyse has
S840074) has been developed to pressure and viscosity changes, a viscosity of 50cSt under normal
give the Icount PD user greater while maintaining its setting even operating conditions then the
flexibility. The flow control device as the workload changes. control knob on the Flow Control
will enable testing where flow Simply position the valve to match Device should be set to valve
ranges are outside the Icount PD the viscosity of the oil you are position ‘3.’
specifications (40 – 140 ml/min), testing.
or where pipe diameters do not The flow device will now
allow the Icount PD to be installed. The chart below can be used to automatically control the flow rate
determine the valve position: through the IcountPD to within its
The flow control device fits onto working range of 40-140ml/min.
the downstream (outlet) side of Valve Position cSt Range
the Icount PD, connecting through Note: The flow control device will
3 up to 100 still operate correctly even with
a manifold block, via a self-sealing
3.8 90 - 200 the high pressure side at 200bar
quick connection test point and is
fitted with a differential pressure 4.2 190 - 320 and the return back to an open
valve. 5 310 - 500 system of 0 bar (DP = 200bar).
P2 P1
(113.2)
4.5”
(58.2)
2.3”
(78.2)
(78.2)
3.1”
3.1”
0.8”
(20)
High Pressure
Line Side
G1/8 ports 1.8” (46.5) 3.5”
either side of
mounting block 2” (50) (90)
“In”
4 holes
Low Pressure 0.26” (6.60)
IN OUT
Return Side Thro’
3.2” Ctrs
(80 Ctrs)
2.4”
(62)
Flow Control
(49.2)
1.9”
Device
“Out”
1.5” Ctrs
(38.0 Ctrs)
Ordering Information
Limit Moisture
Key Fluid Type Calibration Display Relay Communication Sensor Cable Connector Kit
IPD 1 Mineral 1 ACFTD 2 LED 2 Yes 2 RS232/4-20mA 1 No 10 Deutsch DT series connector
2 Aggressive 2 MTD 3 LCD 3 RS232/0-5V 2 Yes 30 M12, 8-pin plug connector*
3 Aviation fuel 3 AS4059
Hazardous areas
4 Aviation fuel
Non Hazardous areas Part Number
Accessories
Mineral Aggressive
1 Meter Hose Length B.84.224 B.84.827
2 Meter Hose Length B.94.802 B.94.801
5 Meter Hose Length B.84.730 B.84.828
1/4” BSP Test point P.653109 (M16) P.843081 (5/8 BSF)
1/8” BSP Test point P.653110 (M16) P.853008 (5/8 BSF)
1/8” NPT Test point P.653512 (M16) P.853005 (5/8 BSF)
Single Point Sampler SPS2021 SPS2026
External Flow Device S840074 Contact Factory
Power Supply B.84.829 B.84.829
5 meter, M12, 8-pin plug
and socket cable kit* Contact Factory Contact Factory
*M12 Cable kit consists of two 5 meter cables to enable all output options
(Communications cable and Relay/Power Supply cable)
127
icountBS - Bottle Sampler
The benchtop solution to fluid contamination
bottle sampling
128
The Complete Solution - Industrial
Design Combined with State of the
Art Technology
The icountBS - Bottle Sampler from The IBS features an easy to
Parker, with its innovative industrial use interactive touch screen,
icountBS - Bottle
design, has been developed for
customers looking for state of
environmentally controlled pressurized
bottle chamber, an internal
Sampler Features &
the art technology, attention to compressor pump, automated door Benefits
detail and the compactness of locking mechanism, sample tube
a permanent laboratory particle cleaning sleeve that minimizes cross • Customer programmable number
analysis instrument. contamination, and an internal printer. of sample runs/sample
bottle averaging and
Combine this with on-board, laser The icountBS benefits from Parkers pre-test flush volumes from 10ml
based, leading edge technology knowledge and experience of min. to 100ml max.
to bring to all industries a truly providing fluid analysis equipment to
revolutionary Particle Counter. The the market for over 15 years. • Input via fluid resistant touch screen
innovative icountBS is a product display.
from the next generation of Parker’s
fluid particle analysis and monitoring • Repeatable and reproducible
solutions. performance to ISO4406:1999,
jAS4059E, and NAS1638 particle
count distributions. Other calibration
standards are included.
• Internal printer.
129
Home Screen Sample ID Input Number of Sample Runs
130
Analyzing the Test Results
Once the automatic oil levels relating to three sizes. 1,300 - 2,500 particles that
sample test has been The first scale number are equal to and greater than
completed, what next? represents the number of 6μm(c), and between 80 - 160
particles that are equal to and particles that are equal to and
Solid contaminants in fluid greater than 4μm (c) per ml of greater than 14μm(c).
power systems vary in size, fluid, the second number for
shape, form and quantity. The particles that are equal to and
most harmful contaminants greater than 6 μm(c) per ml of
are normally between 6 fluid and the third number for
microns and 14 microns. The particles that are equal to and
ISO code is the preferred greater than 14 μm(c) per ml
method of reporting quantity of fluid.
of contaminants.
For example: An ISO code
The ISO code number 20/18/14 indicates that there
corresponds to contamination are between 5,000 - 10,000
particles that are equal to and
greater than 4μm(c), between
131
icountBS Product Specification
Principle of Operation Laser based light obscuration
132
icountBS - Bottle Sampler Ordering
Information
Part Number
IBS3100US
IBS3000FUS (fuel version)
IBS3000MUS (minilab version)
133
icountMS Range
Moisture Sensors
Product Features
• MS moisture sensors provide fast, reliable and accurate
inline detection of moisture in fluids.
• Technology developed for preventative maintenance
programs.
• MS200 ‘Programmable’ sensor monitoring and reporting
relative humidity (RH), moisture content in oils. 6,000 PSI
(420 bar) MAOP.
• MS300 ‘Intrinsically safe’ sensor ATEX certificated for use
in hazardous Zone 0 environments. 6,000 PSI (420 bar)
MAOP.
• Temperature Outputs on all versions.
134
icountMS Range
Features and Benefits
Continuous, online moisture indication, for A purpose designed tee adaptor allows for
hydraulic and lubricating systems. easy installation into an existing fluid system.
Reporting of % relative humidity of water The MS200 can also be specified with a
content, giving the user information on how bench top wand offering the end user greater
close to the fluids real saturation point. flexibility.
Reliable data on the rate of water absorption.
Sensing cell technology using a laser trimmed
thermoset polymer, for capacitive sensing that
is capable of absorbing water molecules due
to its micro porous structure.
Uses a thermistor for temperature
compensation correction. Offering total
confidence in reporting the %RH relative
humidity over the sensors temperature range.
Typical Applications
135
MS150 Moisture Sensor
Specifications
Pressure: Port connections:
Maximum allowable operating pressure. (MAOP): 10 bar 1/4” BSPT or 1/4” NPT.
(145 PSI). Supply voltage:
Operating temperature: +8 to +30 Vdc.
Minimum: -20°C (-4°F). Sensor size/weight/material:
Maximum: +85°C (+185°F). 80mm x 43mm/0.1kg/Aluminium
Flow through sensor cell: IP ratings:
Installed in active flowstream. IP68
Fluid compatibility: %RH Outputs:
Mineral oils, petroleum-based and (+1 to +5 Vdc) or (4 to 20mA)
Phosphate ester.
Temperature Outputs:
Viscosity range: 0 to +5 Vdc
Unlimited.
Installation Details
Thread Form Options
87-88
40.0 A/F 24.0 41.0
BSPT
15.0
Ø10.0
Ø10.0
Ø38.0
R1/4 BSPT
11.0
maximum
All dimensions in millimetres (mm) Dimensions are for reference only Flow in either direction
10.8 with
reamer
Tapping
drill
11.2 without
reamer
MS150 moisture sensor pin designations Installation details for R1/4 BSPT taper
Pin Designation I/O Description
1 Supply Input Supply voltage (+8 to +30Vdc)
2 %RH Output % Saturation out (+1 to +5Vdc) NPT 17.0
3 %RH Output % Saturation out (+4 to +20mA)
4 Temperature Output Temperature out (0 to +5Vdc)
5 Common Input Common (0Vdc) ground from
Ø10.0
11.1 without
200ppm at 150ºF (65ºC). reamer
136
MS200 Moisture Sensor
Specifications
% Saturation Calibration Accuracy: +3% RH
Temperature Calibration Accuracy: ±1°C
Thermal Stability: ±1% RH (over compensated temperature range +10 to +80°C)
Stability: ±0.2% RH typical at 50% RH in 1 year
Linearity: ±0.5% RH typical
Analog Output Hysteresis: ±0.5% RH Full Scale
Switched Output Hysteresis: 2% RH
Operating Temperature Range: -40°F to +185°F (-40°C to +85°C)
Operating Humidity Range: 5 to 100% RH (non condensing)
Response Time: 60 sec in slow moving air at 25°C
Maximum Rated Pressure: 6,000 PSI (420 Bar)
Maximum Torque: 22 ft-lbs
Seal Material (depending on MS): Fluorocarbon, EPDM, Perfluoroelastomer
Material: Stainless Steel 303
Connector Details: M12x1, 8 Way, IP67 Connector (IP68 when mated with molded cable)
Maximum Cable Length: 33 ft (10 m) with Voltage Output, 330 ft (100 m) with current output
Output: SEE ORDERING INFORMATION
Installation Details
4.17-4.21 (106-107mm)
Ø1.02 (26mm).0
Pin 8
.157 (4mm)
Thread detail
dice pattern
.945 (24mm) M12 x 1.0 pitch Pin 1
A/F
Hexagon 1.65 (42mm) Pin Details
137
MS300 Intrinsically Safe
Specifications
Pressure: Outputs:
(MAOP): 6,000 PSI (420 bar) 4-20mA (current loop)
Operating temperature: Calibration accuracy:
Minimum: -40°F (-40°C) - dependent on seal material +/- 5% RH
Maximum: +185°F (+85°C) Compensated thermal stability:
Flow through sensor cell: +/- 1% RH (+ 50°F to +176°F)
Installed in active flowstream Materials:
Fluid compatibility: Stainless steel 303
Mineral oils, petroleum-based and Phosphate ester- Sensor size/weight:
Skydrol option available 4.21in x ø1.97in/0.66 lb (107mm x ø50mm/0.3Kg)
Viscosity range: IP ratings:
Unlimited IP68 (with specified molded cable)
Thread form connections:
See ordering information Developed in association with Triteq Ltd.
4.17-4.21 (106-107mm)
Ø1.97 (50mm) .945 (24mm) 2.24 (57mm)
.512 (13mm)
.157 (4mm)
Thread detail
dice pattern
.945 (24mm) M12 x 1.0 pitch
A/F
Hexagon 1.65 (42mm)
dimensions in inch (mm)
The MS300 has been certified as Intrinsically Safe Electrical Apparatus and offers fast, reliable and accurate in-line
detection of moisture in fluids for use in hazardous areas.
ATEX Certification allows the MS300 into areas of a potentially explosive atmosphere, that have previously not been
allowed without permits, it is intended for use in Zone 0 hazardous areas requiring the use of category 1G equipment
and has been designed for use with galvanic isolators to the specified values stated below:
The electrical parameters: Ui: 28V Ii: 93mA Pi:0.65W Ci: 380nF Li: 0
The following instructions apply to MS300 - 4-20mA Current Loop Moisture Sensor covered by certificate number Sira 07ATEX2255:
1. The equipment may be located where flammable gases of Group I may be present. The equipment is only certified for use in ambient tempera
tures in the range -4°F to +104°F (-20°C to +40°C) and should not be used outside this range.
2. The equipment has not been assessed as a safety-related device (as referred to by Directive 94/9/EC Annex II, clause 1.5).
3. Installation of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice.
4. Repair of this equipment shall be carried out by the manufacturer or in accordance with the applicable code of practice (IEC 60079-19).
138
Moisture Sensor Displays
Specifications
Bar Graph Indicator (PBG8341A)
Construction:
Housing – nylon 6/6, window – acrylic,
Alternative Indicator
bezel/board supports – ABS,
pins – phosphor bronze Description DDU1001 DDU1002
Power supply: Power supply 11 - 30 Vdc 110 - 240 Vdc
11 – 30 Vdc Accuracy ± 0.1% typical ± 0.1% typical
Signal input: (By dipswitch configuration) Sample rate 2.5 per second 2.5 per second
Off – differential up to 5V Operating temp (°C) 0 - 50 0 - 50
A – single signal (Ref. 0V) up to 5V Storage temp (°C) -10 to +70 -10 to +70
B – single signal (Ref. 1V) up to 6V Display N3.5 digit LEDA 31/2 digit LED
Cut out size: Power output (Vdc) 24 24
45.6mm x 45.6mm Weight (kg) 0.30 0.30
Fixing: Panel cutout (mm) 93x45 ± 0.5 93x45 ±/0.5
Push fit panel thickness 0.9mm to 3.2mm Dimensions (mm) 48x96x93 48x96x93
Sealing:
Designed to IP50 standard.
(Front face may be silicon sealed after LED configuration)
Scale:
Supplied 0 to 100% in horizontal
Other scales, in volume, consult Parker Hannifin
Scaling factors:
10% to 100% range. Fully adjustable
Lamp intensity:
4mcd each PBG8341A DDU1001/DDU1002
Front viewing:
Polarized
Weight:
29gms
Product accessories part numbers
Product Number Supersedes Description
139
Ordering Information
140
™
Par-Test
Fluid Analysis
141
Fluid Analysis
Par-Test™
Fluid analysis has proven to be a critical tool for following analysis:
any preventive maintenance program. Fluid analysis Fluid sampling for Par-Test involves important
is able to identify potential problems that cannot be steps to insure you are getting a representative
detected by human senses. sample. Often, erroneous sample procedures will
A comprehensive fluid disguise the true nature
analysis program can of the system fluid. A
help prevent major complete sampling
hydraulic or lube oil procedure is detailed
system failures. on the back of this
brochure. There also is
Par-Test is a
a National Fluid Power
complete laboratory
Association standard
analysis, performed
(NFPA T2.9.1-1972)
on a small volume of
and an American
fluid. The report you
National Standards
receive is a neatly
Institute Standard
organized three page
(ANSI B93.13-1972)
format. One may quickly
for extracting samples
analyze the test results of an
from a fluid power system.
individual sample and/or look at a trend
analysis for up to five different samples. Two types
of services are offered through Par-Test, a water
base fluid analysis kit or a petroleum base fluid anal-
ysis kit. For both types of services the Par-Test kit
includes a pre-cleaned glass bottle, mailing container
with
pre-addressed label, sample information data sheet
(to be completely filled out by end user) and the
142
Fluid Analysis
Par-Test™
FLUID ANALYSIS REPORT
SAMPLE CODE: 93844 DATE: 09/01/04 PARTEST Fluid Analysis Service
Parker Hannifin Corporation
Parker Hannifan 1016 E. Airport Rd.
16810 Fulton Rd. Co #2 Stillwater, OK 74075
Metamora, OH, 43540 Tele: (405)624-0400
Fax: (405)624-0401
ATTN: Kevin Noe
143
Fluid Analysis
Par-Test™
FLUID ANALYSIS REPORT
Viscosity Analysis
SAMPLE CODE: 93844 DATE: 09/01/04 PARTEST Fluid Analysis Service Viscosity is a very important property
Parker Hannifin Corporation
Parker Hannifan
16810 Fulton Rd. Co #2
1016 E. Airport Rd. of a fluid in terms of system
Stillwater, OK 74075
Metamora, OH, 43540 Tele: (405)624-0400 performance. Viscosity expresses the
Fax: (405)624-0401
ATTN: Kevin Noe
internal friction between molecules
in the fluid. Typically a breakdown in
SPECTROMETRIC ANALYSIS Viscosity Analysis - ASTM D445 viscosity will be seen as an increase.
WEAR METALS
PPM BY WEIGHT STATUS*
CST@100C: SSU@210F: Both SSU at 100º F and cSt at 40º C
AND ADDITIVES
CST@40C: 46.25 SSU@100F: 215.0 are reported.
IRON 120.0 H
COPPER 510.0 H Viscosity at 40C (100F) is reported in Centistokes (cST) and SUS
CHROMIUM < 1.0 N
(Saybolt Universal Seconds). The test is conducted in accor- Neutralization Analysis
dance with ASTM D445 procedures for determining the kinematic
LEAD < 1.0 N viscosity of fluids Referred to as the Total Acid Num-
ALUMINUM 1.0 N ber (TAN) this titration test measures
TIN < 1.0 N
Neutralization Analysis - ASTM D794 the acid level of the sample fluid. The
SILICON < 1.0 N
TAN: 0.44 production of acidic material causes
ZINC 423.0 N
Comments Remarks
*Please check spectrometric status for abnormal conditions.
Quick statements or alerts about any
unusual results from one of the tests
reported on this page.
144
Fluid Analysis
Par-Test™
FLUID ANALYSIS REPORT
SAMPLE CODE: 93844 DATE: 09/01/04 PARTEST Fluid Analysis Service
Parker Hannifin Corporation
Parker Hannifan 1016 E. Airport Rd.
16810 Fulton Rd. Co #2 Stillwater, OK 74075
Metamora, OH, 43540 Tele: (405)624-0400
Fax: (405)624-0401
ATTN: Kevin Noe
Trend Analysis
Graphical history for up to
5 samples plotted for 2, 5
and 15 micron and greater
size particles. This analysis
is a valuable tool for tracking
the progress of a system
over a given time period.
Sample Code
Assigned to the test kit form
for a ready reference. This
code can be used to track the
sample from start to finish.
145
Fluid Analysis
Par-Test™
SAMPLING PROCEDURE
Obtaining a fluid sample for analysis II. Systems without a ists, locate a fitting which can be easily
involves important steps to make sure you sampling valve opened to provide turbulent flow (tee or
are getting a representative sample. Often There are two locations to obtain a sample elbow).
erroneous sampling procedures will disguise in a system without a sampling valve: in-tank 3. Flush the valve or fitting sample point
the true nature of system cleanliness levels. and in the line. The procedure for both fol- with a filtered solvent. Open valve or
Use one of the following methods to lows: fitting and allow adequate flushing.
obtain a representative system sample. (Take care to allow for this step. Direct
A. In the Tank Sampling
I. For systems with a 1. Operate the system for at least 1/2 hour. sample back to tank or into a large
sampling valve 2. Use a small hand-held vacuum pump to container. It is not necessary to discard
A. Operate system for at least 1/2 hour. extract sample. Insert sampling device this fluid.)
B. With the system operating, open the into the tank to one half of the fluid height. 4. Place in an approved, pre-cleaned
sample valve allowing 200 ml to 500 You will probably have to weight the end sample bottle under the stream of flow
ml (7 to 16 ounces) of fluid to flush the of the sampling tube. Your objective is to per sampling valve methods.
sampling port. (The sample valve design obtain a sample in the middle portion of 5. Cap sample bottle immediately.
should provide turbulent flow through the tank. Avoid the top or bottom of the 6. Tag with important information per the
the sampling port.) tank. Do not let the syringe or tubing sampling valve method.
C. Using a wide mouth, pre-cleaned came in contact with the side of the tank. Note: Select a valve or fitting
sampling bottle, remove the bottle cap 3. Put extracted fluid into an approved, pre- where the pressure is limited to
and place in the stream of flow from the cleaned sample bottle as described in the 200 PSIG (14 bar) or less.
sampling valve. Do NOT “rinse” out the previous sampling valve method.
bottle with initial sample. 4. Cap immediately.
D. Close the sample bottle immediately. 5. Tag with information as described in
Next, close the sampling valve. (Make sampling valve method.
prior provision to “catch” the fluid while
removing the bottle from the stream.) B. In-line Sampling
E. Tag the sample bottle with pertinent data; 1. Operate the system for at least 1/2 hour.
include date, machine number, fluid sup- 2. Locate a suitable valve in the system
plier, fluid number code, fluid type, and where turbulent flow can be obtained (ball
time elapsed since last sample (if any). valve is preferred). If no such valve ex-
146
Parker Hannifin Corporation Asia Pacific
Filtration Group Europe Australia
Global Headquarters Compressed Air Treatment 9 Carrington Road, Castle Hill
domnick hunter Industrial NSW 2154, Australia
6035 Parkland Boulevard
Worldwide Manufacturing Locations
Dukesway, Team Valley Trading Estate T +61 2 9634 777, F +61 2 9899 6184
Cleveland, OH 44124-4141 Gateshead,Tyne & Wear www.parker.com/australia
T 216 896 3000, F 216 896 4021 England NE11 OPZ China
www.parker.com T +44 (0) 191 402 9000, 280 YunQiao Road
F +44 (0) 191 482 6296 JinQiao Export Processing Zone
www.domnickhunter.com Shanghai 101206 China
North America T +86 21 5031 2525, F +86 21 5834 3714
Compressed Air Treatment Hiross Zander
www.parker.com/china
Filtration & Separation/Balston Padova Business Unit
242 Neck Road Strada Zona Industriale 4 India
Haverhill, MA 01835-0723 35020 S. Angelo di Piove Padova, Italy Plot EL 26, MIDC, TTC Industrial Area
T 978 858 0505, F 978 858 0625 T +39 049 9712 111, F +39 049 9701 911 Mahape, Navi Mumbai 400 709 India
www.parker.com/balston www.dh-hiross.com T +91 22 5613 7081, 82, 83, 84, 85
Filtration & Separation/Finite Hiross Zander F +91 22 2768 6618 6841
www. parker.com/india
500 Glaspie Street, PO. Box 599 Essen Business Unit
Oxford, MI 48371-5132 Zander Aufbereitungstechnik GmbH Japan
T 248 628 6400, F 248 628 1850 Im Teelbruch 118 626, Totsuka-cho, Totsuka-ku
www.parker.com/finitefilter D-45219 Essen, Germany Yokohama-shi, 244-0003 Japan
T +49 2054 9340, F +49 2054 934164 T +81 45 870 1522, F +81 45 864 5305
Purification, Dehydration and www.zander.de www.parker.com/japan
Filtration Division
Parker Gas Separations Korea
4087 Walden Avenue Oude Kerkstraat 4 1-C Block, Industrial Complex of Jangan,
Lancaster, NY 14086 P O Box 258 615-1, Geumui-Ri Jangan-Myeon,
T 716 685 4040, F 716 685 1010 4870 AG Etten- Leur, Netherlands Hwaseong-City Gyeonggi-Do, Korea
www.airtek.com T +31 76 508 5300, F +31 76 508 5333 T +82 31 359 0771, F +82 31 359 0770
Sales Office www.parker.com/korea
5900-B Northwoods Parkway Engine Filtration &
Charlotte, NC 28269 Water Purification Singapore
T 704 921 9303, F 704 921 1960 Racor 11, Fourth Chin Bee Road
www.domnickhunter.com Shaw Cross Business Park Singapore 619 702
Churwell Vale Dewsbury, T +65 6887 6300, F +65 6261 4929
Engine Filtration & WF12 7RD England www.parker.com/singapore
Water Purification T +44 (0) 1924 487000,
Racor Thailand
F +44 (0) 1924 487038
3400 Finch Road, PO Box 3208 1023 3rd Floor, TPS Building
www.parker.com/rfde
Modesto, CA 95353 Pattanakam Road, Suanluang,
T 209 521 7860, F 209 529 3278 Racor Research & Development Bangkok 10250 Thailand
www.parker.com/racor Parker Hannifin GmbH & Co KG T +66 2717 8140, F +66 2717 8148
Inselstrasse 3 – 5 www.parker.com/thailand
Racor 70327 Stuttgart Germany
850 North West St., PO Box 6030 T +49 (0)711 7071 290-0, Latin America
Holly Springs, MS 38635 F +49 (0)711 7071 290 -70 Parker Comercio Ltda.
T 662 252 2656, F 662 274 2118 www.parker.com/racor Filtration Division
www.parker.com/racor
Estrada Municipal Joel de Paula
Racor Hydraulic Filtration 900 Eugenio de Melo,
302 Parker Drive Hydraulic Filter Sao Jose dos Campos
Beaufort, SC 29906 Stieltjesweg 8, 6827 BV CEP 12225-390 SP Brazil
T 843 846 3200, F 843 846 3230 P.O. Box 5008 6802 EA T +55 12 4009 3500, F +55 12 4009 3529
www.parker.com/racor Arnhem, Holland www.parker.com/br
T +31 26 3760376, F +31 26 3643620
Racor -- Village Marine Tec. www.parker.com/eurofilt Pan American Division - Miami
2000 West 135th Street
7400 NW 19th Street, Suite A
Gardena, CA 90249 Urjala Operation Miami, FL 33128
T 310 516 9911, F 310 538 3048 Salmentie 260 T 305 470 8800 F 305 470 8808
www.villagemarine.com 31700 Urjala as Finland www.parker.com/panam
T +358 20 753 2500, F +358 20 753 2501
Hydraulic Filtration
www.parker.com/fi Africa
Hydraulic Filter
16810 Fulton County Road #2 Condition Monitoring Center Parker Hannifin Africa Pty Ltd
Metamora, OH 43540-9714 Brunel Way Thetford, Parker Place, 10 Berne Avenue,
T 419 644 4311, F 419 644 6205 Norfolk IP 24 1HP England Aeroport Kempton Park,
www.parker.com/hydraulicfilter T +44 1842 763299, F +44 1842 756300 1620 South Africa
www.parker.com/cmc T +27 11 9610700, F +27 11 3927213
Process Filtration www.parker.com/eu
Process Advanced Filtration Process Filtration
2340 Eastman Avenue domnick hunter Process
Oxnard, CA 93030 Durham Road, Birtley Co. Durham,
T 805 604 3400, F 805 604 3401 DH3 2SF England
www.parker.com/processfiltration T +44 (0) 191 410 5121,
F +44 (0) 191 410 5312
© 2011 Parker Hannifin Corporation www.domnickhunter.com
Catalog HFD-Auto
147