Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Shubham Pandey 002110401188

QUANTITY SURVEY AND ESTIMATION


Sl No. Description No. Geometric Parameters(m) Quantity Unit Explanatory Notes
L B H/D

Earthwork in excavation of
1
foundation of trench

a Main Wall 46.35 1.1 1 50.985 m^3


b Partition Wall 22.5625 0.8 0.6 10.83 m^3
c Columns 4 1.9 1.9 1 14.44 m^3
Total 76.255 m^3

2 Earthwork in filling Earthwork Filling in Foundation Trench 0.2 * Volume of earthwork excavation

a Main Wall 10.197 m^3


b Partition Wall 2.166 m^3
c Column 4 2.888 m^3
Total 15.251 m^3

3 Brick Flat Soling


a Foundation Trenches
i Main Wall 46.35 1 0.1 4.635 m^3
ii Partition Wall 22.5625 0.7 0.1 1.579375 m^3
iii Column 4 1.9 1.9 0.1 1.444 m^3

b Under Floor
(i) Officer Cabin 1 4 3 0.1 12 m^3
(ii) Attatched Toilet 1 3 2 0.1 6 m^3
(iii) Wating Room 1 10.375 3.975 0.1 41.240625 m^3
(iv) Recption 1 2.3 2 0.1 4.6 m^3
(v) Multipurpose Room 1 4 3.125 0.1 12.5 m^3
(vi) Stair Block 1 4.4 2.2 0.1 9.68 m^3
(vii) Office Space 1 7.187 4.087 0.1 29.373269 m^3
(viii) Toilet 2 3 2 0.1 12 m^3

Total 135.052269 m^3

Cement concrete with


4 grade stone ballast (PCC
in foundation & plinth)
a Foundation Trench
i Main Wall 46.35 1 0.15 6.9525 m^3
ii Partition Wall 22.5625 0.7 0.15 2.3690625 m^3
iii Column 4 1.9 1.9 0.2 2.888 m^3

b Under Floors
(i) Officer Cabin 1 4 3 0.2 2.4 m^3
(ii) Attatched Toilet 1 3 2 0.2 1.2 m^3
(iii) Wating Room 1 10.375 3.975 0.2 8.248125 m^3
(iv) Recption 1 2.3 2 0.2 0.92 m^3
(v) Multipurpose Room 1 4 3.125 0.2 2.5 m^3
(vi) Stair Block 1 4.4 2.2 0.2 1.936 m^3
(vii) Office Space 1 7.187 4.087 0.2 5.8746538 m^3
(viii) Toilet 2 3 2 0.2 2.4 m^3

Doors2 3 1.2 0.25 0.2 0.18 m^3

1
Shubham Pandey 002110401188

doors3 3 0.9 0.25 0.2 0.135 m^3

Total 38.0033413 m^3

25mm thick damp proof


5
course

i Main Wall 46.35 0.25 0.025 0.2896875 m^3


ii Partition Wall 22.5625 0.125 0.025 0.0705078125 m^3

Less for doors


(i) Doors2 3 1.2 0.25 0.025 0.0225 m^3
(ii) Doors3 3 0.9 0.25 0.025 0.016875 m^3
Total 0.3208203125 m^3

First class brick work for


250mm wall in super structure Height of brickwork= F/F height - slab
6 16 thickness
(i) 3.0 0.125 2.875 m
a. Main Wall 1 46.35 0.25 2.875 33.3140625 m^3
Height of mumpty room 2.7 0.125
m^3
b. Stair hall upto mumpty room 1 14.8 0.25 2.525 9.3425 2.525m
c. brick pillers in parapet wall 15 0.25 0.25 1 0.9375 m^3
Total= 43.5940625 m^3
Less for m^3
(ii) Lintle 1 49.238 0.25 0.15 1.846425 m^3
(iii) Windows m^3
a. W1 2 1.5 0.25 1.2 0.9 m^3
b. W2 4 1.2 0.25 1.2 1.44 m^3
c. W3 3 0.8 0.25 0.6 0.36 m^3

Total 39.0476375 m^3

125mm thick brick work with


7 1st class brick 1 6

(i) Partition Wall 1 22.5625 0.125 2.875 8.108398438 m^3


(ii) parapet Wall 1 42 0.125 0.9 4.725 m^3

Less For
a. Doors
(i) Door2 4 1.2 0.125 2.1 1.26 m^3
(ii) Door3 3 0.9 0.125 2.1 0.70875 m^3
b. Lintel 1 27.705 0.125 0.15 0.51946875 m^3
Total= 10.34517969 m^3

Brick Coping above the


8 parapet wall

(i) Parapet Wall 1 42 0.2 0.1 0.84 m^3

Reiinforced cement concrete


9 mix 1 1.5 3 with graded chips

A Column foundation

2
Shubham Pandey 002110401188

part between P.L. and


m^3
(i) pyramidal portion 4 0.3 0.3 0.85 0.306
Trapezoidal volumn= 1/2x(1.5 0.3)x0.
m^3
(ii) Trapezoidal portion 4 1.44 4 0.36
(iii) Rectangular portion 4 1.5 1.5 0.3 2.7 m^3

B column 4 0.3 0.3 2.6 0.936 m^3

C staircase
(i) First flight
a. Waist slab 1 3 1.2 0.15 0.54 m^3
b. mid landing 1 1.5 2.5 0.15 0.5625 m^3

(ii) Second flight


a. Waist Slab 1 3 1.2 0.15 0.54 m^3
b. full landing 1 1.5 2.5 0.15 0.5625 m^3

(iii) steps 10 1.2 0.25 0.15 0.45 m^3

D Slab

total area of roof slab= 81.508 44.


m^3
(i) Total area of roof slab 1 0.125 18.00525 604 17.91 144.022
(ii) stair room roof 1 6.1 3 0.125 2.2875 m^3

Less for
stair hall 1 5.975 2.875 0.125 2.147265625 m^3
Total= 28.32975 m^3
E RCC lintel
(i) Main wall 1 55.35 0.25 0.15 2.075625 m^3
(ii) partition wall 1 29.112 0.125 0.15 0.54585 m^3

F RCC chajja
Over window depth of chajja= 0.1 0.05 /2 0.075
Length of chajja for W1 1.5 0.1 2
m^3
(i) W1 2 1.7 0.45 0.075 0.11475 1.7m
Length of chajja for W2 1.2 0.1 2
m^3
(ii) W2 4 1.4 0.45 0.075 0.189 1.4m
Length of chajja for W3 0.8 0.1 2
m^3
(iii) W3 3 1 0.45 0.075 0.10125 1.0m
(iv) Roof door 1 1.5 0.45 0.0506 0.034155 m^3
Total= 31.39038 m^3

10 Reinforcement for RCC work No L B H/D Quantity Unit

For column foundation,column, volume of rainforcement= 1% of


m^3
(i) staircase ,slab 1 28.32975 2.832975 volume obtained for RCC
volume of rainforcement= 0.8% of
m^3
(ii) for RCC lintle and chajja 1 3.1197 0.0249576 volume obtained for RCC

total= 2.8579326 m^3

total Reinforcement weight= volume 7.85


weight= 22.43477091 MT MT/ cubic meter

Hired labour charge for


11 shuttering

a column foundation

3
Shubham Pandey 002110401188

part between plinth level and


(i) pyramidal section 4 1.2 0.85 4.08 m^2 length= 2x 0.3 0.3 1.2m
(ii) rectangular portion 4 6 0.3 7.2 m^2 length= 2x(1.5 1.5 6m

b Column 4 1.2 2.875 13.8 m^2 hight= 3.0 0.125 2.875m

c Slab
(i) Total roof slab 1 144.022 m^2
(ii) Stair room roof 1 6.1 3 18.3 m^2

Shuttering for slab in front and


d back side ,right,left side
Total length= 55.35 1/2 2 0.25
(i) For roof 1 42.188 0.125 5.2735 m^2 5.850 2.750 42.188m
(ii) for stair hall 1 18.2 0.125 2.275 m^2 total length= 2x 6.1 3 18.2m
Total= 194.9505 m^2

Less for
(i) stair hall 1 5.975 2.875 17.178125 m^2
(ii) main wall 1 55.35 0.25 13.8375 m^2
(iii) partition wall 1 29.112 0.125 3.639 m^2
Total= 34.654625 m^2
shuttering for main wall
e foundation
for outside there is no joints,so the
out side length is equal to the
uncorrected length of main wall=
(i) Outside for PCC 1 55.35 0.2 11.07 m^2 55.35
for inside,it is equal to the corrected
(ii) Inside for PCC 1 47.238 0.2 9.4476 m^2 length 45.238m

f shuttering for partition wall 2 26.805 0.2 10.722 m^2

h Calculation for stair


(i) Waist slab for bottom 2 3 1.2 7.2 m^2
(ii) Side of waist slab 4 3 0.15 1.8 m^2
(iii) mid landing bottom 1 1.5 2.5 3.75 m^2
(iv) Tall landing slab bottom 1 1.5 2.5 3.75 m^2
(v) Mid landing slab side

a Parallel to waist slab 2 1.5 0.15 0.45 m^2


b Perprndicular to waist slab 1 2.5 0.15 0.375 m^2

(vi) Full landing slab side


a Parallel to waist slab 2 1.5 0.15 0.45 m^2
b Perprndicular to waist slab 1 2.5 0.15 0.375 m^2

(vii) Steps (only along risers) 20 1.2 0.15 3.6 m^2

i Chajja Over window


W1 4 1.7 0.65 4.42 m^2
w2 4 1.5 0.65 3.9 m^2
w3 3 1 0.65 1.95 m^2
Roof Door 1 1.5 0.65 0.975 m^2
Total area of one side= 0.25 0.15
Two side of chajja 24 1.7112 m^2 1/2x(0.1 0.05)x0.45 0.0713 sq.m.
Total= 295.100925 m^2
J Lintel NO L B H/D Quantity Unit

4
Shubham Pandey 002110401188

(i) Main wall (side shuttering) 2 55.35 0.15 16.605 m^2 Length are same as DPC calculation
(ii) Partition wall (side shuttering) 2 29.112 0.15 8.7336 m^2
Bottom shuttering for small
(iii) openings

W1 2 1.5 0.25 0.75 m^2


W2 4 1.2 0.25 1.2 m^2
D1 3 1.2 0.125 0.45 m^2
D2 3 0.9 0.125 0.3375 m^2

collapsable gate 1 2 0.25 0.5 m^2


stair hall entrance 1 1.2 0.125 0.15 m^2
Handrail length = same as waist slab
Handrail 2 3 1 6 m^2 length
Total= 35.2261 m^2

Total area for shuttering= 490.6229 m^2

Lime teracing on roof with lime


12 concrete 2 2 1 No L B H/D Quantity Unit

(i) Total area of roof 1 144.022 m^2


(ii) Stair hall roof 1 6.1 3 18.3 m^2

Total= 162.322 m^2

Supplying ,fitting and fixing


marble slab/tile of 15 to 18 mm Area of marble slab = total area of all
13 thickness rooms+ steps+ landing

(i) Officer cabin 1 4 3 12 m^2


(ii) Waiting room 1 10.375 3.975 41.240625 m^2
(ii) Office Space 1 7.187 4.087 29.373269 m^2
(iii) Multipurpose Room 1 4 3.125 12.5 m^2
(iv) Reception 1 2.3 2 4.6 m^2
(v) Office space 1 5 2.425 12.125 m^2
Area of stair hall+ steps= 2.5 1.5
x2 20 1.2 0.15 20 1.2 0.25
(vi) Staircase 1 16.8 m^2 16.8 sq.m

Total= 128.638894 m^2

Supplying fitting and fixing for


14 toilet 3 9.1 1.2 32.76 m^2 total length= 2x(2 3) 0.9 9.1m

15mm thick outside plaster


with sand and cement morter
15 16

if opening area is between 0.5 sq.m to


3 sq.m ,then 1/3 of opening area
main wall (excluding parapet should be deducted for both interior
a) wall) 1 55.35 3.8 210.33 m^2 and exterior.
No deduction for area 0.5 sq.m
parapet wall withour brick
b) couping 1 42.238 1.8 76.0284 m^2 Outer main wall= 50.838 m
Hight of outside wall 3.0 0.75 0.
05 3.8m
Height of parapet wall= 0.9 2 1.8m
c) for brick couping 1 42.238 0.525 22.17495 m^2 (for both side)

5
Shubham Pandey 002110401188

Roof perimeter 50.838 5.85 2.75


42.238
d) for stair hall 1 8.6 2.4 20.64 m^2 Stair hall perimeter=

Total= 329.17335 m^2

6
Shubham Pandey 002110401188

COST Calculation
Sl No. Description Quantity Unit Rate [in Rupees] Unit Amount[in Rupees]

Earthwork in excavation of
1 foundation trench in all sorts of 76.255 m^3 12325 Rs/ 100 m3 9398.42875
soil Depth not exceeding 1.5 m]

Earthwork in Filling Foundation


2 Trenches and plinth with good 15.251 m^3 8250 Rs/ 100 m3 1258.2075
earth layer

3 Single Brick Flat Soling 135.052269 m^3 365 Rs/ m3 49294.07819

Plain Cement Concrete(1 3 6


4 200 mm thick with graded 38.0033413 m^3 3632 Rs/ m3 138028.1356
stones in foundation

5 25 mm Damp Proof Course 0.3208203125 m^3 510 Rs/ m3 163.6183594

First class brick work for


6 250mm wall in super structure 39.0476375 m^3 5639 Rs/ m3 220189.6279
16

125mm thick brick work with 1st


7 10.34517969 m^3 4982 Rs/ m3 51539.6852
class brick 1 6

Brick Coping above the parapet


8 0.84 m^3 1820 Rs/ m3 1528.8
wall

Reiinforced cement concrete


9 31.39038 m^3 5488 Rs/ m3 172270.4054
mix 1 1.5 3 with graded chips

10 Reinforcement for RCC work 22.43477091 MT 59205 Rs/ MT 1328250.612

Hired labour charge for


11 490.6229 m^2 390 Rs/ m2 191342.931
shuttering

Lime teracing on roof with lime


12 162.322 m^2 869 Rs/ m2 141057.818
concrete 2 2 1

Supplying ,fitting and fixing


13 marble slab/tile of 15 to 18 mm 128.638894 m^2 780 Rs/ m2 100338.3373
thickness

Supplying fitting and fixing for


14 32.76 m^2 750 Rs/ m2 24570
toilet

15mm thick outside plaster with


15 329.17335 m^2 140 Rs/ m2 46084.269
sand and cement morter 1 6