Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Documentation

Profibus DP Interface for Vistus Metal Detector

Note: Retain for later use.


Original Document
Version 09.18, Revision E

Minebea Intec Aachen GmbH & Co. KG

Table of Contents
1.  General Information.............................................................................................................. 2 
1.1  Setting the Profibus DP Address ............................................................................ 3 
1.2  Parameterizing the Profibus DP Master (PLC) ................................................... 3 
2.  Input Data (PLC Reads from Metal Detector) ............................................................... 4 
3.  Output Data (PLC Writes to Metal Detector) ................................................................ 5 
4.  Description of Functions ...................................................................................................... 6 
4.1  Change of Product Types .......................................................................................... 6 
4.2  Data Channel ................................................................................................................ 6 
5.  Connecting diagram .............................................................................................................. 7 
6.  Service ....................................................................................................................................... 8 
7.  Ordering Information............................................................................................................ 9 

Minebea Intec Aachen GmbH & Co. KG Am Gut Wolf 11 D-52070 Aachen Tel:+49.241.18270 Fax +49.241.1827.210 www.minebea-intec.com
General Information

1. General Information
The Profibus DP interface for the Vistus metal detector consists of eight bytes for in-
put and eight for output.
A DP interface must be set up for each line. When systems have one control unit and
multiple lines (max. 4), one DP slave is provided for each line.
The Profibus upgrade consists of an optional expansion PCB, which needs to be in-
stalled on the IO-CPU module of the line in question.

After the expansion PCB has been installed, the corresponding Profibus option needs
to be activated on the operator terminal of the metal detector. The dialog to activate
the Profibus option is located on the third page of the system settings.

2
General Information

1.1 Setting the Profibus DP Address


On the VISTUS operator terminal, it is possible to configure the Profibus DP slave ad-
dress for each line (provided that the Profibus expansion option is available).
The dialog page for the Profibus can be found under the system settings and will
only be visible if the Profibus option has already been activated. Before the DP slave
address can be displayed or modified, the Profibus needs to be activated on the cor-
responding line.
The parameter for the DP slave address appears after the checkbox is activated.

Settings for the slave address can be made in the 1-127 range. The default value is 1
for the first line, 2 for the second, 3 for the third, and 4 for the fourth.
If the Profibus has been activated for a line in the system, a check takes place when
starting up the system to determine whether the relevant Profibus hardware is pre-
sent. If this is not detected, a warning (code W0080) is generated.

1.2 Parameterizing the Profibus DP Master (PLC)


The supplied GSD file LdB_7FFF.gsd is required to parameterize the Profibus DP mas-
ter (PLC). The metal detector can then be configured as the DP slave in the Profibus
DP.
The following settings need to be made:

 Slave address: in line with rotary encoder switch (default address "3")
 I/O modules: 8 input/output bytes (selectable in GSD file)
 Baud rate: automatic detection up to 12 Mbaud
 Sync: supported
 Freeze: supported
 ID no.: 0x7FFF

3
Input Data (PLC Reads from Metal Detector)

2. Input Data (PLC Reads from Metal Detector)


The input data range consists of eight bytes.
The following section describes the input data in more detail:

Byte (IB) Meaning


0 Status
Bit: function
0. Error relay (log 1 → no error, log 0 → error)
1. Metal detection signal (feedback on relay contact status)
2. Batch is running
3. Check request
4.
5. Data channel data valid
6. Type change OK
7. Type change is running
1 Vistus outputs reserve
Bit: function
2 Metal counter (high byte)
3 Metal counter (low byte)
4
5 Data channel, value output based on function
6 (see Section xx)
7

4
Output Data (PLC Writes to Metal Detector)

3. Output Data (PLC Writes to Metal Detector)


The output data range consists of eight data bytes.
The following section describes the 8-byte output data in more detail.

Byte (OB) Meaning


0 Vistus inputs
Bit: function
0. Acknowledge error
1. Assigned internally (set/reset by I/O, I/O communication error)
2. -
3. -
4. Delete metal counter
5. Acknowledge metal detection signal
6. Read data channel
7. Change of product types
1 Vistus outputs reserve
Bit: function
2 Product type
Specified type number for product change
3
4
5
6
7 Data channel function

5
Description of Functions

4. Description of Functions
4.1 Change of Product Types
Produktsor tennu mmer vorgeb en
Specify product type number OB2
AB 2

Start Prod uktsorte nwechsel


Start productAtype
0.7 change O0.7

Sort enwechsel läuft


Type change is running I0.7
E 0.7

Sor tenwechsel OK
Type change OK I0.6
E 0.6

Type change failed


Sor tenwe chse l Feh ler haft

Start Prod uktsorte nwechsel


Start product type change O0.7
A 0.7

Sort enwechsel läuft


Type change is running I0.7 2 sec.
E 0.7
Sort enwechsel OK
Type change OK I0.6
E 0.6

In the event of an error during the type change (e.g., type not defined), the "Sort
change is running" signal is deactivated after two seconds; the OK signal is not set!

4.2 Data Channel


The following section shows the read sequence for various data.
Funktion
Specify dataDatenkanal vorgeben
channel function OB7 Fkt.Nr. no.
AB 7 Function

Daten
Read dataDatenkanal lesen
channel data O0.6
A 0.6

Daten
Data Datenkanal
channel gültig
data valid I0.5
E 0.5

Data Daten
channelDatenkanal
data IB4 to IB7
EB4 bis EB7 Daten
Data

The following functions are available:


Function Comments Format
1 Current product type Byte
Output of current product type OB 7
2 Status (error number) Byte
Output of the last error number (e.g., 0xFF04 = compen- OB 7
sation error) (see documentation for Vistus).
If successful, a value of 0 is output.

6
Connecting diagram
m

5. Conn
necting diagram

7
Service

6. Service

Europe (West)

Germany +49.241.1827.111
Am Gut Wolf 11 technical.support.ac@minebea-intec.com
52070 Aachen Spare parts:
+49.241.1827.219
spareparts.ac@minebea-intec.com
Belgium, Netherlands Belgium: +32.2.756.0673
Z.3 Doornveld 33 Netherlands: +31.30.602.50.40
1731 Zellik service.be@minebea-intec.com
service.nl@minebea-intec.com
Switzerland +41.44.746.50.00
Moosmattstrasse 36 mechatronics.switzerland@minebea-intec.com
8953 Dietikon
United Kingdom +44.121.779.3131
2670 Kings Court, The Crescent service.uk@minebea-intec.com
Birmingham Business Park
B37 7YE Birmingham
France +33.1.48.63.20.46
283 Avenue du bois de la Pie service.client@minebea-intec.com
ZI Paris Nord II
95941 Roissy CDG Cedex
Spain, Portugal +34.915.9994.45
C/ Musgo, 2 Edificio Europa II Soporte.iberia@minebea-intec.com
28023 Madrid
Italy +39.0362.361.405
Via Alcide De Gasperi, 202 support.italy@minebea-intec.com
0834 Nova Milanese (MB)

Europe (East)

Poland +48.61.656.02.98
ul. Wrzesinska 70 biuro.pl@minebea-intec.com
62-025 Kostrzy serwis.pl@minebea-intec.com
Russia +7 981 696-36-02
Kievskaya Street 6 service.russia@minebea-intec.com
196084 Saint Petersburg

North/Middle America

USA +1 866 963 8587


1180 Lincoln Ave. Holbrook techsupport.us@minebea-intec.com
NY 11741
Mexico +52 55 1410 58 89
Emiliano Zapata 13-C San Lucas mexico@minebea-intec.com
Tepetlacalco
54055 Tlalnepantla de Baz

8
Ordering Information

7. Ordering Information

Minebea Intec Aachen GmbH & Co. KG


Am Gut Wolf 11
52070 Aachen, Germany
Postfach | P.O. Box 10 09 54
52009 Aachen, Germany
Phone +49 (0)241.1827.0
Fax: +49 (0)241.1827.210

http://www.minebea-intec.com

Sales
Phone +49 (0)241.1827.101
Fax +49 (0)241.1827.210
sales.ac@minebea-intec.com

Printed in Aachen, Germany, 2018

You might also like