Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Patient Name : Mr.

RAJIV BEHL Collected : 15/Aug/2022 07:25AM


Age/Gender : 34 Y 6 M 10 D /M Received : 15/Aug/2022 05:53PM
UHID/MR No : APJ1.0010003694 Reported : 15/Aug/2022 08:32PM
Visit ID : DARGOPV1257 Status : Final Report
Ref Doctor : Dr.SELF Client Name : PUP 24X7_CREDIT
IP/OP NO : Patient location : Ghatta Village,GURGAON

DEPARTMENT OF MOLECULAR BIOLOGY.


COVID 19 RT PCR WITH HOME COLLECTION
Test Name Result Unit Bio. Ref. Range Method

COVID-19(SARS-CoV 2)-REAL TIME PCR(RT-PCR)


SAMPLE TYPE NASOPHARYNGEAL
SWAB AND
OROPHARYNGEAL
SWAB
SARS-CoV-2 NOT DETECTED
N-Gene CT VALUE NOT DETECTED
ORF1ab Gene CT VALUE NOT DETECTED

SRF ID : 0 7 0 7 8 0 1 9 5 4 0 2 0

Comment:
Biological Reference Rang
*Ct value < 35 is Positive
*Ct value >35 is Negative

*Ct cutoff suggested by ICMR


Ct value does not correlate with
disease severity

Please Note:
*CT values vary with the type of kit used, the types of samples collected and the various pre-analytical factors.
*The published studies are conflicting to definitively prove a direct correlation between disease severity/infectiousness and CT
values therefore; relying on CT values for determining infectiousness of COVID-19 patients and deciding management protocols
is left to clinical discretion.

Kit used: CoviPath ™ COVID-19 RTPCR KIT

Result Interpretation
Indicates presence of detectable levels
Detected (Positive) Result
SARS-CoV-2 specific RNA (ORF1ab gene and/ or N gene) in patient’s sample.

Indicates absence of detectable levels


Not Detected (Negative) Result
SARS-CoV-2 specific RNA (ORF1ab gene and/ or N gene) in patient’s sample.

Page 1 of 5
Patient Name : Mr.RAJIV BEHL Collected : 15/Aug/2022 07:25AM
Age/Gender : 34 Y 6 M 10 D /M Received : 15/Aug/2022 05:53PM
UHID/MR No : APJ1.0010003694 Reported : 15/Aug/2022 08:32PM
Visit ID : DARGOPV1257 Status : Final Report
Ref Doctor : Dr.SELF Client Name : PUP 24X7_CREDIT
IP/OP NO : Patient location : Ghatta Village,GURGAON

DEPARTMENT OF MOLECULAR BIOLOGY.


COVID 19 RT PCR WITH HOME COLLECTION
Test Name Result Unit Bio. Ref. Range Method

Indicates the target concentration is too low, or presence of interfering substances


Indeterminate Result
leading to PCR inhibition.

NOTE:

If either of the genes cannot be determined or will give indeterminate results, further testing maybe required using another kit
with a different primer and probe.
A Not Detected (Negative) Resultdo not preclude SARS-CoV-2 and should not be used as the sole basis for patient
management decisions. Kindly repeat test after 48 to 72 hrs if clinically suspected.
Lower respiratory tract specimens are more representative and are preferred.
If at a later date, suspicion of COVID-19 is strong, a fresh sample for Real Time PCR after a gap of 2-4 days after collection
of first sample maybe considered.
Please contact your Physician for necessary action to be taken and to limit the spread of infection.
Clinical Correlation and Correlation with the history of the patient is required before arriving at any conclusion. Presence of
Non-Specific interfering substances during this assay to be kept in mind. Please correlate clinically before arriving at any
conclusion.
False positive and false negative results can be due to multiple factors including sampling technique, transport & interference in
the assay can affect the result.
Presence PCR inhibitors in sample may lead to false negative or invalid results.
Mutation in the target sequence of SARS-CoV-2 or change in the sequence due to virus evolution may lead to false negative
results.
Invalid Result: There is no typical S-shape amplification curve or Ct >35 or No Ct detected for target genes and internal
control, indicating the specimen concentration is too low, or there are interfering substances that inhibit the reaction. If upon
retest, the result is invalid again, another fresh sample should be collected and tested.

SARS-CoV-2 Virus:

SARS-CoV-2 is an enveloped single stranded positive sense RNA virus belongs to family Coronoviridae. It carries largest single
stranded RNA genome of ~30kb and is the causative pathogen of ongoing COVID-19 pandemic (3). The capsid consists of the
nucleocapsid protein N and this is further surrounded by a membrane, that contains three proteins: the membrane protein (M) and the
envelope protein (E), which are involved in the virus budding process, and the spike glycoprotein (S), which is a key player in binding
host receptor and mediating membrane fusion and virus entry into host cells (4).

Page 2 of 5
Patient Name : Mr.RAJIV BEHL Collected : 15/Aug/2022 07:25AM
Age/Gender : 34 Y 6 M 10 D /M Received : 15/Aug/2022 05:53PM
UHID/MR No : APJ1.0010003694 Reported : 15/Aug/2022 08:32PM
Visit ID : DARGOPV1257 Status : Final Report
Ref Doctor : Dr.SELF Client Name : PUP 24X7_CREDIT
IP/OP NO : Patient location : Ghatta Village,GURGAON

DEPARTMENT OF MOLECULAR BIOLOGY.


COVID 19 RT PCR WITH HOME COLLECTION
Test Name Result Unit Bio. Ref. Range Method

Disclaimer:
This Test is based on real-time reverse transcriptase PCR technology for the qualitative detection of severe acute respiratory
syndrome coronavirus 2 (SARS-CoV-2) specific RNA

*ICMR ID- DLUAHTMH-


*ICMR ID-AHLLBHT- HYDERABAD *ICMR ID-AHLVDLA- VIJAYAWADA
MUMBAI
*ICMR ID-ADNTKLKWB -
*ICMR ID-AHLLKDLKAP- KURNOOL *ICMR ID-AHLLDLDD-DELHI
KOLKATA
*ICMR ID-APHLILKDLCTN-
*ICMR ID-AHLLKDIALBK- BENGALURU *ICMR ID-AHHHSPPMH- PUNE
CHENNAI
*ICMR ID-APHLTHLFLADLCK-
LUCKNOW

(For kits determining RdRp gene or ORF1b, sensitivity / specificity of such kits shall be mentioned).

COVID-19 Advisory

Page 3 of 5
Patient Name : Mr.RAJIV BEHL Collected : 15/Aug/2022 07:25AM
Age/Gender : 34 Y 6 M 10 D /M Received : 15/Aug/2022 05:53PM
UHID/MR No : APJ1.0010003694 Reported : 15/Aug/2022 08:32PM
Visit ID : DARGOPV1257 Status : Final Report
Ref Doctor : Dr.SELF Client Name : PUP 24X7_CREDIT
IP/OP NO : Patient location : Ghatta Village,GURGAON

DEPARTMENT OF MOLECULAR BIOLOGY.


COVID 19 RT PCR WITH HOME COLLECTION
Test Name Result Unit Bio. Ref. Range Method

Page 4 of 5

SIN No:MO02731892
Patient Name : Mr.RAJIV BEHL Collected : 15/Aug/2022 07:25AM
Age/Gender : 34 Y 6 M 10 D /M Received : 15/Aug/2022 12:53PM
UHID/MR No : APJ1.0010003694 Reported : 15/Aug/2022 01:50PM
Visit ID : DARGOPV1257 Status : Final Report
Ref Doctor : Dr.SELF Client Name : PUP 24X7_CREDIT
IP/OP NO : Patient location : Ghatta Village,GURGAON

DEPARTMENT OF HAEMATOLOGY
Test Name Result Unit Bio. Ref. Range Method

COMPLETE BLOOD COUNT (CBC) , WHOLE BLOOD-EDTA


HAEMOGLOBIN 13.5 g/dL 13-17 Spectrophotometer
PCV 41.70 % 40-50 Electronic pulse &
Calculation
RBC COUNT 4.54 Million/cu.mm 4.5-5.5 Electrical Impedence
MCV 91.9 fL 83-101 Calculated
MCH 29.8 pg 27-32 Calculated
MCHC 32.4 g/dL 31.5-34.5 Calculated
R.D.W 14.7 % 11.6-14 Calculated
TOTAL LEUCOCYTE COUNT (TLC) 5,080 cells/cu.mm 4000-10000 Electrical Impedance
DIFFERENTIAL LEUCOCYTIC COUNT (DLC)
NEUTROPHILS 44.5 % 40-80 Electrical Impedance
LYMPHOCYTES 43 % 20-40 Electrical Impedance
EOSINOPHILS 0.4 % 1-6 Electrical Impedance
MONOCYTES 11.2 % 2-10 Electrical Impedance
BASOPHILS 0.9 % <1-2 Electrical Impedance
CORRECTED TLC 5,080 Cells/cu.mm Calculated
ABSOLUTE LEUCOCYTE COUNT
NEUTROPHILS 2260.6 Cells/cu.mm 2000-7000 Electrical Impedance
LYMPHOCYTES 2184.4 Cells/cu.mm 1000-3000 Electrical Impedance
EOSINOPHILS 20.32 Cells/cu.mm 20-500 Electrical Impedance
MONOCYTES 568.96 Cells/cu.mm 200-1000 Electrical Impedance
BASOPHILS 45.72 Cells/cu.mm 0-100 Electrical Impedance
PLATELET COUNT 152000 cells/cu.mm 150000-410000 Electrical impedence

Result Rechecked

SRF ID : 0 7 0 7 8 0 1 9 5 4 0 2 0

*** End Of Report ***

Page 5 of 5

SIN No:HA03823792

You might also like