Page 1 of 2 REV-05

Date: March 9, 2016 TPLK.FLG.GRF.Z

Top Lock Flange Nut, IFI 100/107, Grade F, Zinc Plated


The information below lists the required dimensional, chemical and physical characteristics of the products in this purchase order. If
the order received does not meet these requirements, it may result in a supplier corrective action request, which could jeopardize your
status as an approved vendor. Unless otherwise specified, all referenced consensus standards must be adhered to in their entirety.

F H B L K J M R
Flange
Width Across Flange Bearing Flange Wrenching Counter-sink
Size Height Top
Flats Diameter Diameter Thickness Height Diameter
Radius
Max. Min. Max. Max. Min. Min. Min. Max. Max.
#8 .344 .334 .203 .469 - 0.02 0.13 .194 -
#10 .375 .365 .219 .500 - 0.03 0.13 .220 -
1/4 .4385 .428 .300 .560 .484 0.04 0.14 .295 0.01
5/16 .5020 .489 .365 .680 .602 0.05 0.17 .357 0.01
3/8 .5645 .551 .425 .810 .730 0.06 0.20 .420 0.02
7/16 .6895 .675 .495 .930 .846 0.07 0.23 .482 0.02
1/2 .7520 .736 .555 1.070 .982 0.08 0.26 .560 0.02
9/16 .8770 .861 .625 1.190 1.101 0.09 0.29 .622 0.03
5/8 .9395 .922 .690 1.330 1.230 0.10 0.32 .685 0.03
3/4 1.1270 1.088 .825 1.585 1.472 0.11 0.38 .810 0.03
7/8 1.312 1.269 .790 1.750 1.574 0.12 0.41 .945 -
1 1.500 1.450 .900 2.060 1.970 0.12 0.55 1.080 -

Specification Requirements:

• Dimensions: Sizes #8 & #10, 7/8”and 1”: See Table Above


Sizes 1/4” - 3/4”: IFI 100/107
• Material, Performance, &
Mechanical Properties: IFI 100/107 Grade F. 7/8” and 1” Proof load and Clamp load,
shall meet Grade B
• Thread Requirements: ASME B1.1, UNC & UNF, Class 2B
• Finish: Fe/Zn 3AN per ASTM F1941/F1941M and waxed
Page 2 of 2 REV-05
Date: March 9, 2016 TPLK.FLG.GRF.Z

• Marking: 3 evenly spaced marks on either chamfered top face, or the top
of the flange face, or if made from bar stock. Also the
Manufacturer ID (this may be one of the 3 grade markings)
• Material Test Reports: The MTR must have documented lot traceability, dimensional
results, full chemical test results and full mechanical test
results to the specification(s) above. In addition, the MTR
shall be in full compliance with Fastenal’s MTR
Requirements.