Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

NOTE:

NOTE:

STRUCTURAL ENGINEER: PROJECT TITLE : SHEET CONTENTS : OWNER : SHEET NO :

ENGR. ANTONIETTE SAMANTHA A. NACION PROPOSED 3-STOREY RESIDENCE


GENERAL NOTES
A B C A B C A B C

3 3 3

2 2 2

1 1 1

A FOUNDATION PLAN B SECOND FLOOR FRAMING PLAN B THIRD FLOOR FRAMING PLAN
S-1 S-1 S-1

STRUCTURAL ENGINEER: PROJECT TITLE : SHEET CONTENTS : OWNER : SHEET NO :

ENGR. ANTONIETTE SAMANTHA A. NACION PROPOSED 3-STOREY RESIDENCE


GENERAL NOTES
A B C
A B C

3
3

2
2

1
1

B ROOF DECK FRAMING PLAN B ROOF FRAMING PLAN


S-2 S-2

STRUCTURAL ENGINEER: PROJECT TITLE : SHEET CONTENTS : OWNER : SHEET NO :

ENGR. ANTONIETTE SAMANTHA A. NACION PROPOSED 3-STOREY RESIDENCE


GENERAL NOTES
C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM

9M

Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
#10 @ 50 --- #10 @ 125 #10 @ 50 --- #10 @ 125 #10 @ 50 --- #10 @ 125 #10 @ 50 #10 @ 50

11 M

#16 #16 #16


250 250 250 300

4-#16 4-#16 4-#16 4-#16 + 2-#12


C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM

6M

Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 OTHERS
TO
#10 @ 50 #10 @ 50 #10 @ 150 #10 @ 75 #10 @ 75 #10 @ 125 #10 @ 50 #10 @ 50 #10 @ 150 #10 @ 50 #10 @ 50 #10 @ 125 #10 @ 50 #10 @ 50

9M

#16
#12 #12 #12
300 350 300 350 350

8-#12 8-#16 8-#12 4-#16 + 4-#12 4-#16 + 4-#12


C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM

3M

Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 OTHERS
TO
#10 @ 50 #10 @ 50 #10 @ 100 #10 @ 75 #10 @ 75 #10 @ 125 #10 @ 50 #10 @ 50 #10 @ 100 #10 @ 75 #10 @ 75 #10 @ 150 #10 @ 50 #10 @ 50

6M

#16 #16
#12 #12 #16
300 350 300 400 350

4-#16 + 4-#12 8-#16 4-#16 + 4-#12 12-#16 4-#16 + 4-#12


C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm C21 : Fy414 , COVER = 50mm
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM

0M

Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 OTHERS
TO
#10 @ 50 #10 @ 50 #10 @ 150 #10 @ 50 #10 @ 50 #10 @ 150 #10 @ 50 #10 @ 50 #10 @ 150 #10 @ 50 #10 @ 50 #10 @ 175 #10 @ 50 #10 @ 50

3M

C COLUMN REINFORCEMENT DETAILS


#16 #16 #16
#12 #12 #12
300 400 300 400 350

S-4
4-#16 + 4-#12 4-#16 + 6-#12 4-#16 + 4-#12 4-#16 + 8-#12 4-#16 + 4-#12

COLUMN MARKED C1 C2 C3 C4 C5 C8 C8

D COLUMN SCHEDULE
S-4
A TYPICAL FOOTING DETAILS
S-4.0

B FOOTING SCHEDULES
S-4

STRUCTURAL ENGINEER: PROJECT TITLE : SHEET CONTENTS : OWNER : SHEET NO :

ENGR. ANTONIETTE SAMANTHA A. NACION PROPOSED 3-STOREY RESIDENCE


GENERAL NOTES
STRUCTURAL ENGINEER: PROJECT TITLE : SHEET CONTENTS : OWNER : SHEET NO :

ENGR. ANTONIETTE SAMANTHA A. NACION PROPOSED 3-STOREY RESIDENCE


GENERAL NOTES
A TYPICAL TWO-WAY R.C. SLAB DETAIL
S-6
SECTION AT "A"

B SLAB SCHEDULE
S-6

SECTION AT "A"

STRUCTURAL ENGINEER: PROJECT TITLE : SHEET CONTENTS : OWNER : SHEET NO :

ENGR. ANTONIETTE SAMANTHA A. NACION PROPOSED 3-STOREY RESIDENCE


GENERAL NOTES

You might also like