SUBJECT :
Sensor of Maintenance Cover L/R Turns Off

MODEL:
VG-640/540
SG-540/300

SYMPTOM:
Sensor of Maintenance Cover L/R turns off even if the cover stays closed.

CAUSE:
The Maintenance Cover L / R wears and backlash occurs between the cover and the frame.

ACTION:
Fix the plate on the Maintenance Cover L/R to eliminate the backlash.

Maintenance Cover L Maintenance Cover R

New Parts

1000017830 STOPPER,COVER SIDE L 1000017829 STOPPER,COVER SIDE R 31019703 SCREW,BINDING P-TIGHT


VG-640 VG-640 M3*8 3C 100P

Revision No. Date Description of changes Approval Issued by

0 2017.3.24 First Edition Kawai Kohara

Copyright 2017. Roland DG Corporation. All rights reserved. DQF-7511-02-1(Rev.0)

No sell, no rental, no distribution, no disclosure and no reproduction without permission.


NO. RSB-0086 (2/2)
DATE 2017.3.24
SERIAL NUMBER:
The measure has been already implemented to the machines with serial numbers below.
VG-640: To be informed
VG-540: To be informed
SG-540: To be informed
SG-300: To be informed

Copyright 2017. Roland DG Corporation. All rights reserved. DQF-7511-02-1(Rev.0)