Professional Documents
Culture Documents
RSB-0086 en
RSB-0086 en
RSB-0086 (1/2)
DATE 2017.3.24
Confidential
SERVICE INFORMATION
SUBJECT :
Sensor of Maintenance Cover L/R Turns Off
MODEL:
VG-640/540
SG-540/300
SYMPTOM:
Sensor of Maintenance Cover L/R turns off even if the cover stays closed.
CAUSE:
The Maintenance Cover L / R wears and backlash occurs between the cover and the frame.
ACTION:
Fix the plate on the Maintenance Cover L/R to eliminate the backlash.
New Parts