FMEA No-
POTENTIAL FAILURE MODE AND EFFECT ANALYSIS ( PROCESS)
Rev No / Date
Part Name- WATER PUMP HOUSING Part No. D10369520A Rev.Details 0
F-7.3.1-01
Vehicle Model- AVL Customer M/S Escorts Kubota Process Responsibility- Mr. Mohit
Name Mr. Lovelaish Dassi Mr. Mohit Mr. Rahul Mr. Rajkumar
Core Team- Customer Approval (If Reqd.)
Sign
OCCURANC
OCCURANC
DETECTION
DETECTION
SEVERITY
SEVERITY
Process Function / Resp. &
Potential Failure Potential Cause(S) Current Process Control Current Process Control Recommended Target Action
Potential Effect of Failure CLASS RPN RPN
E
Mode Mechanism (S) of Failure Prevention Detection Action (S) Completion Taken
Requirement Date
Op.
Cause or Failure
reducing the
occurrence,
decreasing
customer?
detection?
severity or
actions for
improving
In what ways What is the impact of the What are the existing controls
Mode?
occur?
What are the What are the causes of How do you detect the Cause
CTQ
can the process Failure Mode on the and procedures that prevent the
process steps? the Failure Mode? or Failure Mode?
step go wrong? customer? Cause or Failure Mode?
Patrolling inspection on
Improper or loose
uneven facing leakage issue after assy 6 3 Set up approval hourly basis 5 90
clamping of part
n=1,c=0 per hr
Facing rough first
Guidance given to Shop
10 Side(GASKET
operator/WI supervisor
SEAL SIDE) Patrolling inspection on
fitment isuue at customer
Less height Initial setup not done 3 Set up approval hourly basis 5 90
end
n=1,c=0 per hr
Tool wear out. Tool life monitoring sheet Inprocess inspection (MAPL-
. 4 5 100
F-QA-02) after every hour
Reaming operation fails and
Dia oversize 5 Wrong tool selection i.e.
roughness not maintain
length of tool not as per 3 Only skilled & trained operators FPA &LPA (MAPL-F-QA-03) 5 75
Rough boring Guidance given to Shop
20 our requirement can perform the operation in the to be done at start & end of
dia 38.067-0.020 operator/WI supervisor
guidance of supervisor process
Tool run out 3 5 75
Concentricity out Program may be Inprocess inspection (MAPL-
2 Program locked 7 70
tampered F-QA-02) after every hour
Runout of tool 3 Only skilled & trained operators FPA &LPA (MAPL-F-QA-03) 5 90
If oversize then not
assembled with its mating can perform the operation in the to be done at start & end of
6 Wrong tool selection i.e. guidance of supervisor process & Inprocess
Drill Ø9±0.2 part at customer end. length of tool not as per 3 5 90
(6 Holes) . inspection (MAPL-F-QA-02)
Customer dissatisfaction our requirement
Program may be after every hour
tampered 2 Program locked 7 84
Tool wear out. Tool life monitoring sheet
4 5 100
.
Wrong tool selection i.e. FPA &LPA (MAPL-F-QA-03)
If undersize then not Only skilled & trained operators to be done at start & end of
length of tool not as per 3 5 75
assembled with its mating can perform the operation in the process & Inprocess
5 our requirement
part at customer end. guidance of supervisor
Tool run out 3 inspection (MAPL-F-QA-02) 5 75
Customer dissatisfaction
after every hour
Program may be
2 Program locked 7 70
tampered
MAPL
FMEA No-
POTENTIAL FAILURE MODE AND EFFECT ANALYSIS ( PROCESS)
Part Name- WATER PUMP HOUSING Part No. D10369520A
Rev No / Date
Rev.Details 0
F-7.3.1-01
Vehicle Model- AVL Customer M/S Escorts Kubota Process Responsibility- Mr. Mohit
Name Mr. Lovelaish Dassi Mr. Mohit Mr. Rahul Mr. Rajkumar
Core Team- Customer Approval (If Reqd.)
Sign
OCCURANC
OCCURANC
DETECTION
DETECTION
SEVERITY
SEVERITY
Process Function / Resp. &
Potential Failure Potential Cause(S) Current Process Control Current Process Control Recommended Target Action
Potential Effect of Failure CLASS RPN RPN
E
Mode Mechanism (S) of Failure Prevention Detection Action (S) Completion Taken
Requirement Date
Op.
No. Mounting hole Tool may be offsetted 3 5 75
drilling, spot face & FPA &LPA (MAPL-F-QA-03) Guidance given to Shop
30
boss height to be done at start & end of operator/WI supervisor
maintain Misaligned with its mating Fixture may be offsetted 3 Only skilled & trained operators 5 75
Mounting hole process & Inprocess
part at customer end 5 can perform the operation in the
location out inspection (MAPL-F-QA-02)
Customer dissatusfaction guidance of supervisor
after every hour with
Part not clamped properly 4 receiving gauge 5 100
May result in fitment failure *Not using the fixture Use of Fixture.
Angle 15° not as
of thermostat at customer 5 *Part not clamped 4 Only trained & skilled 5 100
per specification
end properly operators perform the operation.
Use of Fixture.
Not as per required
Drill Depth 42 Customer dissatisfaction 5 3 Only trained & skilled 5 75
specification
operators perform the operation.
*Carelessness of
operator. *Mixing
Due to absence of leak hole
of processed and 4 5 100
water pump may jammed
unprocessed ones.
Use of Fixture.
5 Only trained & skilled
*Carelessness of operators perform the operation.
Absence of leak hole may
operator. *Mixing
close the warning system for
of processed and 4 5 100
the user for a bad water
unprocessed ones.
pump
FPA &LPA (MAPL-F-QA-03)
F-7.3.1-01
MAPL
FMEA No-
POTENTIAL FAILURE MODE AND EFFECT ANALYSIS ( PROCESS)
Rev No / Date
Part Name- WATER PUMP HOUSING Part No. D10369520A Rev.Details 0
Vehicle Model- AVL Customer M/S Escorts Kubota Process Responsibility- Mr. Mohit
Name Mr. Lovelaish Dassi Mr. Mohit Mr. Rahul Mr. Rajkumar
Core Team- Customer Approval (If Reqd.)
Sign
OCCURANC
OCCURANC
DETECTION
DETECTION
SEVERITY
SEVERITY
Process Function / Resp. &
Potential Failure Potential Cause(S) Current Process Control Current Process Control Recommended Target Action
Potential Effect of Failure CLASS RPN RPN
E
Mode Mechanism (S) of Failure Prevention Detection Action (S) Completion Taken
Requirement Date
FPA &LPA (MAPL-F-QA-03)
Op. to be done at start & end of
No. Drill Ø6 process & Inprocess
In case of oversize customer Only skilled & trained operators
6 Wrong tool selection 3 inspection (MAPL-F-QA-02) 5 90
dissatisfaction perform the operation
after every hour with PPG
NG material dispatch to
Hole Locations customer and it may results 6 Inspection standard not Inspection standards and work
4 3 72
in customer complaint available. instructions displayed.
MAPL
FMEA No-
POTENTIAL FAILURE MODE AND EFFECT ANALYSIS ( PROCESS)
Rev No / Date
Part Name- WATER PUMP HOUSING Part No. D10369520A Rev.Details 0
Vehicle Model- AVL Customer M/S Escorts Kubota Process Responsibility- Mr. Mohit
Name Mr. Lovelaish Dassi Mr. Mohit Mr. Rahul Mr. Rajkumar
Core Team- Customer Approval (If Reqd.)
Sign
OCCURANC
OCCURANC
DETECTION
DETECTION
SEVERITY
SEVERITY
Process Function / Resp. &
Potential Failure NG material dispatch to Potential Cause(S) Current Process Control Current Process Control Recommended Target Action
Potential and
Effect of Failure CLASS RPN RPN
E
HoleMode
Locations customer it may results 6 Mechanism (S) of Failure Prevention Detection Action (S) Completion Taken
Requirement in customer complaint Date
Op.
No. Gauge issued and always
Unavailability of receiving
4 available at final inspection as 3 72
gauge
per requirement
Taper Hole Dia Inspection standard not Inspection standards and work
Customer dissatisfaction 5 4 Final Inspection 4 80
10 available. instructions displayed.
Visual
Inspection Skilled quality inspector
(Operation Customer dissatisfaction 3 Unskilled inspector 4 100% Visual Inspection 4 48
deployed
missing, casting
defects etc.)