Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

www.vlf-test.

com

VLF High Voltage Test System


VLF-50T

Application
VLF-50T supply AC withstand voltage testing, dielectirc loss (tgδ test), Capacity(μF), IR(Ω).
(Partial discharge,DC withstand voltage test and DC leakage current test for buyer’s option).
This device is mainly suitable for AC withstand voltage testing of large capacity test objects such as
cables and motors,it is not suitable for resistive test objects with small capacitance, such as zinc oxide
lightning arresters.

VLF Advantage
1. AC Withstand voltage testing, Voltage & current curve display.
2. Tan delta (tgδ test), capacitance (μF) and IR (Ω) Test without external device.
3. Partial discharge testing without external device (for option).
4. DC withstandi voltage test,DC leakage current measurement (for buyer’s option).
5. ”IEE 400.2” Analysis of Tan delta test result.
6. Safe Optical isolation technology.
7. Easiest to use Fully automatic microcontroller.
8. H/L voltage closed loop negative feedback control circuit, output no capacity rise effect.
9. Built-in printer.
10. Built-in protective resistors.
11. Colour Touch LCD (154*86mm)operation, True sine wave output.
12. Real-time display of actual output waveform.
13. Ergonomic, menu guided, large colour touch screen
14. Storage of test results for later retrieval and print.
15. Over voltage and current protected.
16. Auto variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz.
17. 60 mins continuous working;
18. Data of current, voltage and waveform directly sampled at HV side.
19. Rugged and reliable design less prone to failure from transients.
20. Invatation Patent
21. Portable: Control unit + Booster (Tank)
22. CE mark.
23. RS232/USB for option.

Specification
1.Power: 220V ± 10% AC (110V can be customized), 50/60Hz, single phase;
2.Output-Voltage (Peak): 1 to rated value (50KV),
3.Output frequency: 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz (auto variable frequency);
4.Load:0.1Hz-0.01Hz auto variable frequency, Capacity≤10µF
5. Stability of frequency: Fluctuation < 0.5%;
6. Measurement accuracy: ±3%;

1
www.vlf-test.com

7. Positive and negative voltage peak error: ≤3%;


8. Voltage waveform distortion: ≤5%;
9. Construction: 1 Control unit + 1 Booster;
10. Ambient conditions of use: temperature Indoor and outdoor : -10ºC ~ + 50ºC.
11. Humidity:≤85%
12. Technical indexes of VLF tgδ test:
1) tgδ test voltage range: 1 to 40KV
2) Measurement voltage accuracy: 3%
3) Dielectric loss test frequency: 0.1Hz
4) Measurement range: 0.01×10-3- 655.35×10-3
5) Dielectric loss accuracy: 1x10-4
6) Dielectric loss resolution: 1x10-5
7) Capacitance measurement range: 0.001μF-10μF
8) Celectric capacity resolution: 0.001μF
9) Current measurement range: 0–59mA Tan delta/PD test curve
10) Current resolution: 0.1mA
11) Insulation resistance: 0.01GΩ-65.53GΩ
12) Insulation resistance resolution: 10MΩ

13.Main technical indexes of VLF PD test (for option):


1) Partial discharge measurement range: 0.01pc-200pc
2) Partial discharge detection sensitivity: 0.01pc
3) Capacitance range: 0.001μF-10μF
4) Sampling bits: 12 bits
5) Sampling speed: 12M/S U, PD & tgδ curve

6) Test voltage: 0 to 50 (KV)

14.DC leakage current measurement (for option):


1) Output rated voltage: same as rated AC voltage output
2) Voltage accuracy: 3%
3) Leakage current range: 0-2000μA, or 0-20mA (customized)
4) DC Current resolution: 1μA
5) DC current accuracy: 3%
6) It is necessary to parallel the capacitor we supplied if testing DC leakage current.

PD test interface display

2
www.vlf-test.com

Load Capacity
Model no Output Control Unit Booster(Tank)
Voltage/
Power
Current Capacitance/ Net Dim. Net Wt Net Dim. Net Wt
(Peak) Freuency (cm) (kg) (cm) (kg)
0.1Hz-0.01Hz
VLF-50T 50KV/30mA Auto Variable 40×31×20 6 29x15×35 45 1500W
Capacity:≤10µF

True LCD screenshoot test results

Analysis of Tan delta test results (IEE400.2)

3
www.vlf-test.com

Field connection diagram (Test object: cable)

Package for transport

Sr no Name of Commodity Qty N.W G.W Transport size


(LxWxH)
Controller 1 unit 5 kg
1 Capacitor 0.04µF 1 unit 5 kg 82 kg 450x380x800mm
Booster I (30/40KV) 1 unit 45 kg
Aluminum alloy box 1 unit 5kg
Total: 1 set 60 kg 82 kg 0.14 m3
Packed in 1 wooden case.

4
www.vlf-test.com

Accessories

Sr no. Description Quantity Remarks

1 Control unit 1 unit


2 Booster 50KV 1 unit
Used as Capacity supplement, or test
3 Capacitor (0.04µF) 1 unit
object for demo
4 Discharge rod 1 unit

5 HV Test/Connection cables 1 set

6 Earth cable 1 unit

7 Power supply cable 1 unit

8 Fuse 2 units

9 Printer paper 1 unit

10 Operating manual 1 unit


11 Aluminium alloy box 1 unit
12 Calibration report 1 unit

Wuhan Goldsol Co.,Ltd


Add: No 128 Sanyang Road Wuhan China.TeL:
86-27-82423362

You might also like