EC054 5 Solenoids Pump
EC054 5 Solenoids Pump
www.tacmina.com
Safe, Easy and Long-life
Relief-valve function,
easy operation,
tough body,
extensive selection of
liquid-end materials,
driven diaphragm-type
injection requirements.
1
Model Selection Guide
Model Selection Guide
by Application and Function
Small Capacity
PZ PZ
PZ
No-input
Manual Setting
PW PW
PWM
Digital-input/output
Digital-input/output &
PW
Digital Setting Analog-input
PWT Digital-input/output &
Multi Functions Timer Control
Standard High-viscosity Boiler
PZD
Middle Capacity
PZD No-input
PZi /PZD
Digital Setting
PZiG
PZi G
PZiG Digital-input/output &
Digital Setting Analog-input
Advanced Functions
Standard High-viscosity type
DCLPW/CLPW/CLPZ
Air Block Analog-input
DCLPWT Digital-input/output &
In-Line Automatic Air-release Timer Control
CLPZ
Timer Control
CLPZ No-Input
For Sodium Hypochlorite
AR
AR
ARPZ No-input
Automatic Air-release
ARPZ
■ Application
OTHER
2
By Application
For Injection of General Chemicals
Series Small Capacity Small Capacity Middle Capacity Large Capacity
PZ PW PZD PZi
PZi4 PZi8
PZiG
Manual Setting Digital Setting PW Digital Setting Digital Setting PZiG
PWM Digital Setting
Multi Functions PWT Advanced Advanced Functions
Functions
Model 30R 60R 100R 30 60 100 30R 60R 100R 30 60 100 200 300 500 300 500 300 500 700 1000
Max. discharge mL/min 30 60 100 30 60 100 30 60 100 30 60 100 220 360 540 360 540 340 530 760 1000
volume L/h 1.8 3.6 6.0 1.8 3.6 6.0 1.8 3.6 6.0 1.8 3.6 6.0 13.2 21.6 32.4 21.6 32.4 20.4 31.8 45.6 60.0
Max. discharge MPa 0.7 0.4 1.0 0.8 0.4 0.7 1.0 0.7 0.2 0.3 0.2 0.3 0.2 1.0 0.7 0.4 0.3
pressure bar 7.0 4.0 10.0 8.0 4.0 7.0 10.0 7.0 2.0 3.0 2.0 3.0 2.0 10.0 7.0 4.0 3.0
.
Max. allowable viscosity mPa s ∼50 ∼50 ∼50 ∼50 ∼50
Relief valve function ○ ̶ ○ ̶ ̶ ̶ ̶ ̶
PW Digital-input/output PZi4
PWM Digital-input/output & Digital-input & PZiG
Signal PZD Analog-input
No-input Analog-input No-input Digital-input/output &
PWT Digital-input/output & PZi8 Analog-input
Digital-input/output &
Timer Control Analog-input
Liquid-end material PVC/PVDF/SUS PVC PVC/PVDF/SUS PVC/PVDF
Reference page GO to GO to GO to GO to
P5 P7 P 13 P 17
PZ PW PW PZD PZiG
Manual Setting Digital Setting PW Digital Setting PW Digital Setting PZD Digital Setting PZiG
PWM PWM
Multi Functions PWT Multi Functions PWT Advanced Functions
Model 30R 30 30R 30 30 60 100 300 500 300 500 700 1000
Max. discharge mL/min 28 28 25 60 100 360 540 340 530 760 1000
volume L/h 1.68 1.68 1.5 3.6 6.0 21.6 32.4 20.4 31.8 45.6 60.0
Max. discharge MPa 1.5 1.5 2.0 1.0 0.7 0.3 0.2 1.0 0.7 0.4 0.3
pressure bar 15.0 15.0 20.0 10.0 7.0 3.0 2.0 10.0 7.0 4.0 3.0
Max. allowable viscosity mPa.s ∼50 ∼50 ∼3000*1
Relief valve function ○ ̶ ○ ̶ ̶ ̶ ̶
PW Digital-input/output PW Digital-input/output
PWM Digital-input/output & PWM Digital-input/output &
Signal No-input Analog-input Analog-input No-input Digital-input/output &
PWT Digital-input/output & PWT Digital-input/output & Analog-input
Timer Control Timer Control
GO to GO to GO to GO to GO to
Reference page P5 P7 P7 P13 P17
3
*1 the
When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of
liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids.
Model Selection Guide
For Injection of Sodium Hypochlorite
Series
DCLPW CLPW CLPZ ARPZ
Air Block DCLPW In-Line CLPW Automatic
DCLPWM Automatic CLPWM Air-release
In-Line Automatic DCLPWT Air-release CLPWT
Air-release
Model 30R 60R 100R 30 60 100 30R 60R 100R 30 60 100 30R 60R 100R 30 60 100 31 61 12
Max. discharge mL/min 30 60 90 30 60 90 30 60 90 30 60 90 30 60 100 30 60 100 27 54 93
volume L/h 1.8 3.6 5.4 1.8 3.6 5.4 1.8 3.6 5.4 1.8 3.6 5.4 1.8 3.6 6.0 1.8 3.6 6.0 1.62 3.24 5.58
Max. discharge MPa 0.7 1.0 0.7 0.7 1.0 0.7 0.7 0.4 1.0 0.8 0.4 1.0 0.8 0.4
pressure bar 7.0 10.0 7.0 7.0 10.0 7.0 7.0 4.0 10.0 8.0 4.0 10.0 8.0 4.0
Max. allowable viscosity mPa.s ∼50
Relief valve function ○ ̶ ○ ̶ ○ ̶ ̶
DCLPW Digital-input/output CLPW Digital-input/output
DCLPWM Digital-input/output & CLPWM Digital-input/output &
Signal Analog-input Analog-input No-input
DCLPWT Digital-input/output & CLPWT Digital-input/output &
Timer Control Timer Control
GO to GO to
Reference page
P21 P23
By Function For details on each product, see the reference page for
the respective model or "Explanation" on page 26.
Series Small Capacity Middle Capacity Large Capacity For Sodium Hypochlorite
DCLPW DCLPWM DCLPWT
PZ PW PWM PWT PZD PZi4 PZi8 PZiG CLPZ ARPZ
Function CLPW CLPWM CLPWT
Input — 2 1 2 — 2 4 4 2 1 2 — —
Signal Digital
(No. of ports) Output — 2 — ̶ 2 2 2 — —
Analog Input — 1 ̶ — 1 1 ̶ 1 ̶ — —
Power supply to Flow Checker ̶ — ̶ ○ ̶ ̶ — —
Stroke speed ○ ○ ○ ○ ○ — —
Manual Discharge volume — ○ ̶ ○ ○ ○ ○ ̶ — —
Percentage — ○ ○ ○ ̶ — —
Pulse-input proportional control ○ ̶ ○ ̶ ○ ○ ○ ̶ ○ — —
Analog-input proportional control — ○ ̶ ̶ ○ ○ ̶ ○ ̶ — —
Interval operation — ○ ̶ ○ ○ ̶ ○ — —
— ○ ̶ ̶ ̶ ̶ ○ — —
Auto Timer control
Control Count operation(batch control) — ○ ̶ ○ ○ ̶ ○ — —
External operation-signal control — ○ ̶ ̶ ̶ ○ — —
External stop-signal control — ○ ̶ ○ ○ ○ — —
2-point Level Switch control*1 — ○ ̶ ○ ○ ○ — —
ECO mode — ○ ̶ ̶ ̶ ̶ — —
SAFE mode — ○ ̶ ̶ ̶ ○ — —
Relief valve function — ○ ̶ ̶ ̶ ○ — —
Alarm function — ○ ̶ ̶ ○ ○ ○ — —
Memory-read error ( LCD display only) — ̶ ○ ○ ○ ̶ — —
Tank-level w/1-point Level Switch — ○ ̶ ○ ○ ○ — —
alarm w/2-point Level Switch — ̶ ̶ ̶ ○ ○ ̶ — —
(30R/60R/100R) (30/60/100)
VTCE/VTCF VTCET
Material: PVC (for injection of boiler chemicals)
Application example:Transfer/ inject ion of Material: PVC
general chemicals Application example:Transfer/ inject ion of
boiler chemicals
w/ Relief Valve
FTCE/FTCF/FTCT 6TCT
Material: PVDF Material: Stainless steel(SUS316)
Application example:Transfer/ inject ion of Application example:Transfer/ inject ion of
special chemicals(e.g. strong and mixed acids) solutions/special chemicals
5
Specification: PZ
Model 30R/30 60R/60 100R/100
VTCET
Specif ication
VTCE VTCF FTCE FTCF FTCT 6TCT
( for injection of
boiler chemicals ) VTCE VTCF FTCE FTCF FTCT 6TCT VTCE VTCF FTCE FTCF FTCT 6TCT
mL/min 30 27 28 60 55 100 95
Max. discharge volume*1
L/h 1.8 1.6 1.68 3.6 3.3 6.0 5.7
MPa 0.7[1.0] 0.5 1.5 0.7[0.8] 0.5 0.4
Max. discharge pressure*1
PZ
(PE) (PVC braided hose) (PE) (PE)
Relief /air-release 4 x 6 (soft PVC hose)
Max. allowable viscosity 50 mPa . s
Allowable temperature Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed)
Ambient humidity 35 to 85% RH
Environmental protection IEC standard: IP65 or equivalent (water- and dust-proof)
Altitude of instrallation location Less than 1,000 m
Noise level Less than 85 dB
Operation
Manual Setting stroke speed (15 to 300 strokes/min) w/ manual dial
mode
Model Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material".
30/60/100
B
(A)
VTCET
130
Item
VTCE VTCF FTCE FTCF FTCT 6TCT
( for injection of
boiler chemicals )
118 E G
Discharge side : 2 m 110
Hose/ Tube*1 3m
Suction side : 1 m (F)
R3
Relief /air-release hose* 1
1 m*2 1 m*2
6
* 1 For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above. The mounting pitch allows mounting from 87 to 110 mm.
6
Capacity
Small
PW Digital Setting
Multi Functions
PW Digital-input/output
PWM Digital-input/output &
Analog-input
PWT Digital-input/output &
Timer Control
SAFE mode for preventing Relief valve function for Alarm function for
abnormal pressure buildup releasing abnormal pressure notifying abnormal pressure
While the discharge valve is closed, When the pressure exceeds When abnormal pressure builds up due to clogging
the liquid transfer force is controlled the setting value, the relief of the pipes or while the discharge valve is closed,
to prevent pressure buildup. valve operates automatically. an alarm is emitted to warn this condition.
Automatically Alarm
releases pressure output
STOP!
*To use the SAFE mode, set the stroke length to *Standard type pump discharge pressure: 0.7MPa. *When the alarm function is used together with the
100%. Boiler-type pump discharge pressure: 1.5MPa. SAFE mode, an alarm is emitted for pressure lower
*The SAFE mode is not available for PW-200, boiler *The Relief valve function cannot be selected for than the normal pressure.
type and high-pressure type. SUS type, high-viscosity type, and high-pressure *This function is disabled at the factor y default
*The fun c tion is disabled at the fac tor y default type pumps. setting.
setting.
Outputs an alarm when abnormal pressure builds up Requires a discharge pressure of 0.7MPa minimum
SAFE mode
SAFE mode Relief valve function Alarm function
Alarm function
7
■ Function correspondence table
PW/PWM/PWT DCLPW/DCLPWM/DCLPWT
CLPW/CLPWM/CLPWT
General chemical model High-viscosity Boiler High-pressure Sodium hypochlorite
30R/60R/100R 30/60/100 200 60/100 30R 30 30 30R/60R/100R 30/60/100
Relief valve function ○ - - - ○ - - ○ -
SAFE mode ○ ○ × ○ × × × ○ ○
Alarm function ○ ○ ○ ○ ○ ○ ○ ○ ○
ECO mode ○ ○ × ○ ○ ○ ○ × ×
* A circle (○) is indicated for the corresponding function that can be set. A cross (×) is indicated for the corresponding function that must not be set even though it is technically possible.
PW
low-pressure operation in order to reduce power consumption.
Power-on time
to solenoid
1 cycle 1 cycle 1 cycle 1 cycle Power
1 サイクル consumption reduction
example: PW-60 model
High pressure Operating pressure: 1.0MPa
Number of strokes: 300 strokes/min.
1.0MPa Average power consumption: 18W
Up to 55% reduction
of power consumption
Simple key operations Operation can be performed The liquid-end parts are easy
IEC standard:
and user interface enable using a voltage between to disassemble and replace by
IP65 or equivalent
intuitive operation. AC100 and 240V (±10%). simply detaching four bolts.
ECO
SAFE
ECO
SAFE
ECO
SAFE
PVC
PVC PVDF Stainless steel (For high-viscosity
PL Manual strokes/min PL Manual strokes/min PL Manual strokes/min
1/n mL/min 1/n mL/min 1/n mL/min
STOP ×n CAL STOP ×n CAL STOP ×n CAL
liquids)
8
Wide-ranging Control Functions
Realize Ideal Chemical Injection
Systems
stop control
n pumps
SAFE SAFE
0.5mA 0.5mA
When the pump is used in Open collector or
combination with a level meter no-voltage
The pump can be turned on and and checker, an alarm is output contact signal
COM COM
off using a input signal from an during abnormal pressure
external device. buildup.
You can connect multiple instances
Analog signal of this pump in parallel.
■Synchronous pulse control
Flow meter
(pulse/analog)
SAFE
110Ω ECO
SAFE
110Ω
single pump operation. The output
PL Manual strokes/min PL Manual strokes/min
1/n mL/min 1/n mL/min
STOP ×n CAL STOP ×n CAL
+ − + −
pulse can be input to a second pump Analog +
ECO ECO ECO
STOP
Manual
1/n
×n
mL/min
CAL
ECO
SAFE
strokes/min PL
STOP
Manual
1/n
×n
ECO
SAFE
strokes/min
mL/min
CAL
pulse signal. PL
STOP
Manual
1/n
×n
mL/min
CAL
ECO
SAFE
strokes/min PL
STOP
Manual
1/n
×n
mL/min
CAL
ECO
SAFE
strokes/min PL
STOP
Manual
1/n
×n
mL/min
CAL
ECO
SAFE
strokes/min PL
STOP
Manual
1/n
×n
mL/min
CAL
ECO
SAFE
strokes/min PL
STOP
Manual
1/n
×n
mL/min
CAL
ECO
SAFE
strokes/min PL
STOP
Manual
1/n
×n
mL/min
CAL
ECO
SAFE
strokes/min
■Automatic operation (1) Set point (SP) setting (2) Proportional band (PB) setting
SP setting range: 0 to 100% PB setting range: -999 to 999%
The pump operates for a specified number Discharge volume
of strokes in the range of 0 to 300 strokes 100
(%) Fixed PB, variable SP 100
(%) Fixed SP, variable PB 100%
(300strokes/min) (300strokes/min)
per minute in accordance with the setting
value (set point, proportional band), upon
50%
−PB2 PB1
receiving an analog input signal (4 to 20mA). (−50%)(50%)
PB PB PB PB3
(100%)
0 0
9 SP2 SP1 SP3 SP 50%
Item PW (pulse type) PWM (analog type) PWT (timer type)
Digital
Number of ports
Input signal Analog
Type Stop signal, pulse signal Stop signal, pulse signal Stop signal, pulse signal
Number of ports Digital
Output signal
Type Sync pulse, alarm output Sync pulse, alarm output Sync pulse, alarm output
Number of strokes 1 to 300 (Enables setting in 1-stroke units)
Manual
operation Discharge volume 0.1 to maximum discharge volume
control (Enables setting in 0.1mL/minute units)
Control Pulse proportional control
Analog proportional control
Timer control
External operation & stop input signal
PW
■Interval mode ■DAY mode
Pump operation can be turned on and off in accordance with The pump operates automatically everyday using the same ON
the setting of the timer. You can set any ON and OFF period for and OFF timing that is set. You can set up to nine program patterns
one pattern each in the range of 1 to 9999 minutes. within the range of 0:00 to 24:00 in 1-minute unit.
*DAY mode cannot be used together with the WEEK mode.
Setting example: ON period: 5 minutes Setting example: ON time: ① 1:00 ② 6:30 ③11:30 ④17:15
OFF period: 3 minutes OFF time: ①5:00 ②10:30 ③15:15 ④21:15
5 minutes 5 minutes 5 minutes
1:00 6:30 11:30 17:15
ON ON
① ② ③ ④
OFF OFF
START 0:00 5:00 10:30 15:15 21:15 23:59
3 minutes 3 minutes 3 minutes
3分
●When both interval mode and pulse operation are simultaneously set, the
pump will operate in accordance with pulse frequency-division or pulse
frequency-magnification setting within the ON time set for the DAY mode
and interval mode.
■WEEK mode
The pump automatically operates every week at the same ON and OFF time being set for the day of the week.
You can set one program pattern for each day of the week. You can set the ON time from 0:00 to 24:00 and OFF time within the range 0:00 to 48:00 in 1-minute unit.
*WEEK mode cannot be used together with DAY mode.
●When the pulse proportional control operation is set, the pump will operate in accordance with the pulse frequency-division or pulse
frequency-magnification set for this operation.
●When both interval mode and pulse proportional control operation are simultaneously set, the pump will operate in accordance with
pulse frequency-division or pulse frequency-magnification set for this operation.*1
*1 The number of strokes will be the value set in each program.
The following combination of functions can also be used besides the abovementioned combination.
Interval mode
External operation control DAY mode External operation control
DAY mode + Pulse proportional control + + Interval mode + Pulse proportional control +
External stop control WEEK mode External stop control
WEEK mode
10
■Model code *Not all model combinations are possible. When selecting the pump model, first check “Specification” and “Liguid-end material”.
1 Series name 2 Model(discharge volume standard) 3 Liquid-end material 4 Hose standard 5 Joint specification 6 Applicable standard 7 Power plug
(size/material)
[General chemical liquid injection model
w/relief valve]
PW: Standard (pulse input) type 30R : 30mL/min VTCE 4×9 PVC W : Standard S : Standard EUP : Euro plug
PWM: Analog input type 60R : 60mL/min VTCF 6×11 PVC CE : CE marking ULP : UL plug
PWT: Timer control type 100R : 100mL/min FTCE 6×8 PE/FEP/PTFE -compatible AUP : Australia plug
[General chemical liquid injection model] 1/4"×3/8" PE/FEP UKP : UK plug
FTCF
JPL : Japan lead wire
30 : 30mL/min FTCT
60 : 60mL/min 6TCT
100 : 100mL/min
200 : 220mL/min*1
*1 SAFE mode and ECO mode cannot be used. The information pertaining to liquid-end parts only applies to the VTCE/VTCF type. *2 SAFE mode cannot be used.
■Performance specifications
Model PW/PWM/PWT
30R/30 30 30R/30 30 60R/60 60 60
Specification VTCE/VTCF FTCE/FTCF FTCT 6TCT VTCET(boiler) VTCET(high-pressure) VTCE/VTCF FTCE/FTCF FTCT 6TCT VTCF(high-viscosity)
mL/min 30 27 28 25 60 55 60
Max.discharge volume*1
L/H 1.8 1.62 1.68 1.5 3.6 3.3 3.6
MPa 0.7/1.0 *2 0.5 1.5 2 0.7/1.0 *2 0.5 0.7
Max.discharge pressure*1
bar 7/10 *2 5 15 20 7/10 *2 5 7
Stroke speed 1 ∼ 300 strokes/min (Enables setting in 1-stroke units)
Stroke length 0.5 ∼ 1 mm (Enables adjustment using the dial)
Discharge side 4 x 9(PVC braidedhose) 6 x 8(PE) 6 x 8(FEP) 4 x 6(PA) 4 x 6(PA) 6 x 11(PVC braided hose) 6 x 8(PE) 6 x 8(FEP) 12 x 18
Connection 6 x 8(PE)
1/4"x3/8"(PE) 1/4"x3/8"(FEP)
6 x 8(PTFE) 6 x 8(PE) 6 x 8(PTFE)
Suction side 1/4"x3/8"(PE) 4 x 9(PVC braided hose) 4 x 9(PVC braided hose) 1/4" x 3/8"(PE) 1/4"x3/8"(PE) 1/4"x3/8"(FEP) (PVC braided hose)
(hose/tube:I.D x O.D)
Air-release 4 x 6 (soft PVC hose) - 4 x 6 (soft PVC hose) -
Viscosity of transfer liquid 50mPa・s or less 3,000mPa・s or less*3
Temperature of transfer liquid 0 ∼ 40℃(no freezing allowed)
Ambient temperature 0 ∼ 40℃
Environmental resistance IEC standard:IP65 or equivalent (water-&dust-proof)
Insulation class B
Rated voltage AC 100 to 240 V (±10%)
No. of phases/Frequency 1-phase/50 or 60 Hz
Power Max. current 2A 2.5 A
supply Max. power consumption 200 VA 250 VA
Avg. power consumption 15 W 18 W
Cable Cabtyre cable (φ5∼10)
Weight kg 1.8 1.8 1.8 3.2 1.9 1.9 1.9 1.9 1.9 3.3 1.9
*1 Conditions:Clean water, room temperature. *2 0.7MPa (7bar) for models w/relief valve(R type) whereas 1.0MPa (10bar) for models w/o relief valve.
*3 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids.
Model PW/PWM/PWT
100R/100 100 100 200
Specification VTCE/VTCF FTCE/FTCF FTCT 6TCT VTCF(high-viscosity) VTCE/VTCF
mL/min 100 95 100 220
Max.discharge volume*1
L/H 6 5.7 6 13.2
MPa 0.7 0.5 0.7 0.2
Max.discharge pressure*1
bar 7 5 7 2
Stroke speed 1 ∼ 300 strokes/min (Enables setting in 1-stroke units)
Stroke length 0.5 ∼ 1 mm (Enables adjustment using the dial)
Discharge side 6 x 11(PVC braided hose) 6 x 8(PE) 6 x 8(FEP) 12 x 18
6 x 11(PVC braided hose)
Connection 6 x 8(PE)
1/4"x3/8"(PE) 1/4"x3/8"(FEP)
6 x 8(PTFE)
(PVC braided hose)
6 x 8(PE)
Suction side 1/4" x 3/8"(PE) 1/4" x 3/8"(PE)
(hose/tube:I.D x O.D)
Air-release 4 x 6 (soft PVC hose) - -
Viscosity of transfer liquid 50mPa・s or less 3,000mPa・s or less*2 50mPa・s or less
Temperature of transfer liquid 0 ∼ 40℃(no freezing allowed)
Ambient temperature 0 ∼ 40℃
Environmental resistance IEC standard:IP65 or equivalent (water-&dust-proof)
Insulation class B
Rated voltage AC 100 to 240 V (±10%)
No. of phases/Frequency 1-phase/50 or 60 Hz
Power Max. current 2.5 A
supply Max. power consumption 250 VA *1 Conditions:Clean water, room temperature.
*2 When transferring high-viscosity liquids,
Avg. power consumption 18 W the maximum discharge volume may be lower than
the specified volume depending on the characteristics of
Cable Cabtyre cable (φ5∼10) the liquid and operating conditions.
Consult TACMINA separately when
11 Weight kg 1.9 1.9 1.9 3.3 1.9 4 transferring high-viscosity liquids.
■Control function specifications ■Accessories
Item PW PWT PWM PW/PWM/PWT
One port: analog signal General chemical model Boiler High pressure High viscosity
(DC 4 to 20 mA,
Item
Analog input −−− input resistance:
approximately 110 Ω) VTCE VTCF FTCE FTCF FTCT 6TCT VTCET VTCET VTCF
One port: pulse signal
One port: pump stop
(no-voltage contact or open collector, Discharge side:
signal (no-voltage
maximum no. of pulses: 1200 pulses/minute,
contact or open collector, 2m
minimum pulse width: 25 ms [ON period]) Hose / Tube
Signal Input One port: pump stop signal
maximum no. of pulses: 3m 3m 3m 3m 3m
1200 pulses/minute, Suction side:
(no-voltage contact or open collector,
Digital minimum pulse width: 1m
maximum no. of pulses: 1200 pulses/minute,
25 ms [ON period])
minimum pulse width: 25 ms [ON period])
One port: solenoid sync pulse signal Air purge hose with relief valve*1 1m*2 1m −−− 1m −−−
(DC 25 V, 10 mA or less)
Output One port: batch warning signal
(DC 25 V, 10 mA or less) 1 set 1set
Anti siphonal check valve 1set(R1/2) −−−
(R1/2 or R3/8) (R1/2)
Number of strokes 1 to 300 (Enables setting in 1-stroke units)
Manual
Discharge
0.1 to maximum Foot valve 1set −−−
operation discharge volume
volume control (Setting in 0.1mL/min. −−− −−−
units enabled)
Ceramic weight −−− 1set −−−
Pulse Division 1/999∼1/1 −−− −−− Hose pump −−− 1set −−−
proportional
control Magnification 1∼999 −−− −−− Cable ties (INSULOK®)
1 −−− 1 −−−
for relief hose (spare)*3
Proportional band/set
Analog proportional control −−− −−−
point method Signal cable 2m
Interval −−− 1 pattern (1∼9999min.) −−− Pump attachment bolts and nuts 2 sets (M5x30)
PW
Timer + Pulse Division −−− 1/999∼1/1 −−−
proportional
control Magnification −−− 1∼999 ○
External operation signal ○ ○ ○
External stop signal ○ ○ ○
Operation sync pulse ○ ○ ○
Alarm output ○ ○ ○
■External dimensions
●PW/PWM/PWT/−30□/60□/100□ ●PW/PWM/PWT−200 ●PW/PWM/PWT/−30□/60□/100□
(6TCT)
C
84.5
92.5
UP
OP EN
B
167.5
169
PVC
(224.5)
(233)
A
84.5
75
ECO
SAFE ECO
140
ECO
SAFE
PL Manual strokes/min
140
SAFE
1/n mL/min
140
34
34
74 16.5 75 74 22 98 74 16.5 75
7
R3 R3 R3
87
87
87
6
87 87 87
A B C D
VTCE/VTCF 216 152 76 76
FTCE/FTCF/FTCT 237 195 97.5 97.5
VTCF (High viscosity) 233 167.5 92.5 75
VTCET(BWJ) 230 166 90 76
VTCET(PWJ) 233 169 93 76
* The shape and dimensions differ slightly depending on the liguid-end material and connection type.
12
Capacity PZD PZi
Middle
Digital Setting Digital Setting
PZD No-input
Advanced Functions
PZi4 Digital-input & Analog-input
PZi8 Digital-input/output & Analog-input
Common Functions
Direct Entry of Injection Amount Wide Voltage AC100 240V ( 10%)
The injection amount can be set according to three patterns: Range Power Supply
[ By stroke speed ] There is no need to worry about site
Setting range: 1 to 300 strokes/min power supply voltage or voltage fluctuations
(minimum setting increment: 1 stroke/min)
since it can be used with AC100 to 240 V
[ By discharge volume ] ( 10%) power supplies. You can also keep it in
Setting range: 0.1 to (maximum discharge volume of stock safely since it can be used for a variety of sites and applications.
selected model) mL/min
(minimum setting increment: 0.1 mL/min)
[ By percentage ]
Setting range: 1 to 100%
(minimum setting increment: 1% (3 strokes/min)) High-viscosity Max.
3000mPa・s
The PZD series can also be used for the
injection of polymer coagulant.
Extensive Range of Liquid-end Materials * When transferring high-viscosity liquids, the maximum discharge volume may be lower
than the specified volume depending on the characteristics of the liquid and operating
conditions. Consult TACMINA separately when transferring high-viscosity liquids.
VTCE/VTCF FTCT
Material: PVC Material: PVDF
Application example: Application example:
Transfer/ inject ion of
general chemicals
Transfer/ inject ion of
special chemicals
Simple Key Layout
(e.g. strong and mixed acids)
PZD
6TCT VTCF Stroke-length
(high-viscosity type*) adjustment dial Pilot lamp
Material: Stainless steel
(SUS316.304) Material: PVC 50
40 60
Application example: Application example: 30 70 LCD panel
Transfer/ inject ion of Transfer/injection of
solutions/special chemicals high-viscosity liquids
20 80
START/STOP key
90 MODE key
* Provided for PZD series only. 0 100%
UP key
STROKE LENGTH DOWN key
80
w/ backlight *
START/STOP key
90
MODE key
0 100%
UP key
STROKE LENGTH
DOWN key
Separate-type Head & Controller
* Backlight is provided only on PZi8.
Specifications
This feature is limited depending on the operating conditions. Consult us for details.
13
PZD PZi4 |PZi8
Quick & Easy Calibration ■External operation & stop control
The PZD Series is provided with easy calibration function The pump can be turned on and off using a input signal from an
for accurate pump calibration. Just push the button to external device.
automatically discharge 300 strokes' worth of chemical
and enter the actual discharge volume that you will be
Level meter
measuring. This is all you need to do for accurate calibration.
PZi4| PZi8
Chemical
liquid tank
PZi /PZD
Conventional system PZi
Pulse-transmitting flow meter
pH meter pH C Controller pH meter pH C Controller
Main piping
INV.
Level Switch
P P P
PZi
INV.
PZi8
P
PZi 2-point Level Switch Control
Controller C Controller C
Control such as alarm display 2-point Level Switch
R R and output, and pump stop
P P Residual P P Residual
chlorine meter chlorine meter is performed in accordance
with the remaining amount
of chemicals.
PZi8
Motor Driven Pump PZi
. Inverter required . Inverter not required Count (batch) & Interval (timer) Operation
Count setting Start/Stop signal
14
Specification: PZD
Model 300 500
Specification: PZi4/PZi8
Model 300 500
Specif ication VTCE VTCF FTCT STCT VTCE VTCF FTCT STCT
15
* 5 For details, see "Analog-Input Proportional Control" and "Pulse-Input Proportional Control" on page 14.
*
6 When 2-point Level Switch is used
Model Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material".
Accessory When "NON" is selected for power plug, the power cable (2m) is not provided.
Model PZD PZi4/PZi8
Hose/ Tube*1 3m 3m
PZi /PZD
1 set 1 set 1 set 1 set
Anti-siphon check valve (R1/2 or R3/8) (R1/2) (R1/2 or R3/8) (R1/2)
Foot valve 1 set 1 set
Ceramic weight 1 set*2 1 set*2
Pump mounting nu ts / bolts 2 sets ( M5 x 30 )
Operation manual 1 set
* 1 For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above.
*2 Only when PE tube is selected
D
B
B
(A)
(A)
C
C
155
155
E
31
E
31
68 G 68 G
7
87
3 VTCE/VTCF 243 176 88 88 24.5 180 85.5 3 VTCE/VTCF 243 176 88 88 24.5 180 85.5
R
6
R
6
FTCT/STCT 255.5 183 82.5 100.5 22 174.5 83 FTCT/STCT 255.5 183 82.5 100.5 22 174.5 83
VTCF 281.5 253 126.5 126.5 26 181 85.5 87
87 (High-viscosity)
The shape and dimensions differ slightly depending on the liquid-end material and connection type.
The mounting pitch allows mounting from 87 to 110 mm.
16
Capacity PZiG
Large
Digital Setting
Advanced Functions
PZiG Digital-input/output &
Analog-input
* When transferring high-viscosity liquids, the maximum discharge volume may be lower
than the specified volume depending on the characteristics of the liquid and operating
conditions. Consult TACMINA separately when transferring high-viscosity liquids.
50
Specifications
40 60
30 70
IEC standard: IP65 or equivalent
Stroke-length 20 80
Avoid condensation and immersion in water.
adjustment dial 90
0 100%
STROKE LENGTH
ALARM ON
w/ backlight
Alarm lamp
MODE key SET
Function key
FUNC
START RESET
90
0 100%
STROKE LENGTH
for accurate pump calibration. Just push the button to For details, refer to the "Liquid-end Material" table on the following page.
VTCE/VTCF FTCT
automatically discharge 300 strokes' worth of chemical
Material: PVC Material: PVDF
and enter the actual discharge volume that you will be Application example: Application example:
Transfer/injection of Transfer/injection of
measuring. This is all you need to do for accurate calibration. general chemicals special chemicals
(e.g. strong and
mixed acids)
VTCF
(high-viscosity type)
Material: PVC
Application example:
Transfer/injection of
high-viscosity liquids
17
Analog-Input Proportional Control 2-point Level Switch Control
The injection amount (stroke frequency: 0 to 300 strokes/min) Control such as alarm display
2-point Level Switch
can be set according to the analog input signal (0 to 20 mA or 4 and output, and pump stop
to 20 mA) from an ex ter nal dev ice. is performed in accordance
with the remaining amount
pH Control of chemicals.
Conventional system PZiG
PZiG
INV.
Controller C Controller C
PZiG
R R
P P P P
Residual Residual
chlorine meter chlorine meter
PZi G
. Raw liquid must be diluted . Raw liquid can be injected Anti-siphonal
2 Damper check valve
since the discharge volume since the discharge volume
per stroke is large. per stroke is small.
Pressure gage
3-way joint
2 Damper
Install a damper or air chamber when
the piping is long or to suppress
vibration on the piping.
PZiG
For details on the Level Switch, see "Option" on the back cover.
18
Specification
Model 300 500
VTCF VTCF
Specif ication
VTCE VTCF FTCT
( high-viscosity
type ) VTCE VTCF FTCT
( high-viscosity
type )
mL/min 340 530
Max. discharge volume*1
L/h 20.4 31.8
1 MPa 1.0 0.5 1.0 1.0 0.7 0.5 0.7 0.7
Max. discharge pressure*
bar 10.0 5.0 10.0 10.0 7.0 5.0 7.0 7.0
Stroke speed 1 to 300 strokes/min (digital setting)
Stroke length 0.3 to 1.5 mm (adjustable by manual dial)
Relief /air-release
Max. allowable viscosity 50 mPa . s 3000 mPa.s*2 50 mPa . s 3000 mPa.s*2
Allowable temperature Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed)
Ambient humidity 35 to 85% RH
Environmental protection IEC standard: IP65 or equivalent (water- and dust-proof)
Altitude of instrallation location Less than 1,000 m
Noise level Less than 85 dB
Analog-Input 1 port : Analog signal (4 to 20 mA DC, 0 to 20 mA, input resistance: approx. 110 )*3
2 ports: High-speed pulse signal (no-voltage contact or open collector, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))*
3
2 ports: Low-speed pulse signal (no-voltage contact or open collector, min. pulse width: 50 msec (ON time))
Input
Signal assignments : Unassigned, Pulse signal, Stop signal, Start signal, Reset/Restart signal, Alarm reset signal,
Signal (4 selectable) Level Switch signal (only when Level Switch is used), Compulsive MAX operation signal
Digital*4
2 ports: Pulse signal (10 mA DC, 25 V or less)
Output Signal assignments : Unassigned, Solenoid-operation sync pulse signal, In-operation signal, Running signal, Operation end signal, Lamp alarm signal,
(4 selectable) Low tank-level alarm signal (only when 2-point Level Switch is used), Pulse-Input error signal, Analog-Input error signal
Manual Digital settings: 3 patterns [stroke speed (1 to 300 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 mL/min increments), percentage (1 to 100%, in 1% increments)]
Analog-Input
proportional control*5 Control possible by Proportional Band ( PB ) setting/Set Point ( SP ) setting
Pulse-Input
proportional control*5 Control possible by Frequency-division ( 1/1 to 1/9999 ) setting/Multiplication ( 1 to 9999 ) setting
Count operation
Operation (batch control) 1 to 9999 strokes ( x1, x10, x100, x1000 )
mode Auto
Interval operation
(timer control) ON time: 1 to 9999 min/OFF time: 1 to 9999 min
*5 For details, see "Analog-Input Proportional Control" and "Pulse-Input Proportional Control" on page 18.
*6 When 2-point Level Switch is used
Model Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material".
* For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above.
19
Specification
Model 700 1000
VTCF VTCF
Specif ication
VTCE VTCF FTCT
( high-viscosity
type ) VTCE VTCF FTCT
( high-viscosity
type )
mL/min 760 1000
Max. discharge volume*1
L/h 45.6 60.0
1 MPa 0.4 0.3
Max. discharge pressure*
bar 4.0 3.0
Stroke speed 1 to 300 strokes/min (digital setting)
Stroke length 0.3 to 1.5 mm (adjustable by manual dial)
FNPT 3/4 FNPT 3/4
Discharge side 12 x 18 12 x 15 12 x 18 12 x 15
Connection (PVC braided hose) (PTFE) MNPT 3/4 MNPT 3/4
(PVC braided hose) (PTFE)
(hose/tube: VP 20 VP 20
Suction side FNPT 1/2 FNPT 1/2 FNPT 1/2 FNPT 1/2
I.D x O.D) (Union Joint) (Union Joint)
Relief /air-release
Max. allowable viscosity 50mPa . s 3000mPa.s*2 50 mPa . s 3000 mPa . s * 2
Allowable temperature Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed)
Ambient humidity 35 to 85% RH
Environmental protection IEC standard: IP65 or equivalent (water- and dust-proof)
Altitude of instrallation location Less than 1,000 m
Noise level Less than 85 dB
Analog-Input 1 port : Analog signal (4 to 20 mA DC, 0 to 20 mA, input resistance: approx. 110 )*3
2 ports: High-speed pulse signal (no-voltage contact or open collector, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))*
3
2 ports: Low-speed pulse signal (no-voltage contact or open collector, min. pulse width: 50 msec (ON time))
Input
Signal assignments : Unassigned, Pulse signal, Stop signal, Start signal, Reset/Restart signal, Alarm reset signal,
Signal (4 selectable) Level Switch signal (only when Level Switch is used), Compulsive MAX operation signal
Digital*4
2 ports: Pulse signal (10 mA DC, 25 V or less)
Output Signal assignments : Unassigned, Solenoid-operation sync pulse signal, In-operation signal, Running signal, Operation end signal, Lamp alarm signal,
(2 selectable) Low tank-level alarm signal (only when 2-point Level Switch is used), Pulse-Input error signal, Analog-Input error signal
Manual Digital settings: 3 patterns [stroke speed (1 to 300 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 mL/min increments), percentage (1 to 100%, in 1% increments)]
Analog-Input
proportional control*5 Control possible by Proportional Band ( PB ) setting/Set Point ( SP ) setting
Pulse-Input
proportional control*5 Control possible by Frequency-division ( 1/1 to 1/9999 ) setting/Multiplication ( 1 to 9999 ) setting
PZi G
Power consumption Max.: 750 VA /Ave.: 100 W
Weight 11 kg
*1 Conditions: Clean water, room temperature *2 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids.
.
5 .
5
A
R4 R4
A
169
9
9
100
100
.
5
B
R4
339
9
170
C
100
A
338
B
170
145 145
170
14
14
169
145
165 38 32 165 38 32
4
1
D 170 E 170
E F 165 38 32
B 170
A
20
Hypochlorite
For Sodium
Chemical
liquid
■Air-release performance
■Air block mechanism
Comparison of the time required to purge air that is trapped in the pump
head between CLPW and previous models (CLPZD, ARPZD).
DCL series pumps are equipped with a degassing Test conditions (Discharge pressure: 1.0MPa, air volume: 0.1mL) Test conditions (Discharge pressure: 1.0MPa, air volume: 0.5mL)
joint as standard equipment. The degassing joint 120 600
prevents intrusion of air that causes gas lock.
100 500
Air purge time [sec.]
Prevents Air
Liquid
80
Approx. 66% 400
Approx. 60%
intrusion of reduction reduction
60 300
maximum 15cc
40 200
of air.
20 100
Unable to purge air
Suction 0 0
Previous model Previous model Previous model Previous model
CL type AR type CL type AR type
[ Usage Precaution ]
When diluting sodium hypochlorite, use pure water or water processed with a water softener.
21 Otherwise the pump may malfunction or discharge trouble may result.
■Model code *Not all model combinations are possible. When selecting the pump model, first check “Specification” and “Liguid-end material”.
1 Series name 2 Control type 3 Model 4 Liquid-end material 5 Hose standard 6 Joint specification 7 Applicable standard 8 Power plug
(discharge volume standard) (size/material)
[W/ relief valve]
DCLPW : Air block and None : Standard (pulse input) 30R: 30mL/min ATCF 4×9PVC S: Standard EUP:Euro plug
in-line type automatic air- type 60R: 60mL/min 6×11PVC W : Standard CE: CE marking ULP :UL plug
release functions M : Analog input type 100R: 90mL/min 6×8PE -compatible AUP:Australia plug
CLPW : In-line type T : Timer control type 1/4"×3/8"PE UKP:UK plug
automatic air-release function [W/O relief valve] JPL:Japan lead wire
30 : 30mL/min
60 : 60mL/min
100 : 90mL/min
■Specifications
Model DCLPW CLPW CLPZ
Specification 30R 60R 100R 30 60 100 30R 60R 100R 30 60 100 30R 60R 100R 30 60 100
Max.discharge mL/min 30 60 90 30 60 90 30 60 90 30 60 90 30 60 100 30 60 100
volume L/H 1.8 3.6 5.4 1.8 3.6 5.4 1.8 3.6 5.4 1.8 3.6 5.4 1.8 3.6 6 1.8 3.6 6
Max.discharge MPa 0.7 1.0 0.7 0.7 1.0 0.7 0.7 0.4 1.0 0.8 0.4
pressure bar 7.0 10.0 7.0 7.0 10.0 7.0 7.0 4.0 10.0 8.0 4.0
Stroke speed 1 to 300 strokes/min (Enables setting in 1-stroke units) 15 to 300 strokes/min (dial setting)
Stroke length 0.5∼1 mm (Enables adjustment using the dial) Fixed at 1.0 mm
4×9 6 × 11 4×9 6 × 11 4×9 6 × 11 4×9 6 × 11 4×9 6 × 11 4×9 6 × 11
Discharge side (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose) (PVC braided hose)
6×8 6×8 6×8 6×8 6×8 6×8 6×8 6×8 6×8 6×8 6×8 6×8
(PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE)
Connection 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8" 1/4" × 3/8"
Suction side
(hose/tube:I.D × O.D) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE) (PE)
Air-release 4 × 6 (soft PVC hose) - 4 × 6 (soft PVC hose) - 4 × 6 (soft PVC hose) -
Degassing joint*3 1/4" × 3/8" (soft PVC hose) -
Viscosity of transfer liquid 50mPa・s or less
Temperature of transfer liquid 0∼40℃(no freezing allowed)
Ambient temperature 0∼40℃
Environmental resistance IEC standard:IP65 or equivalent (water-&dust-proof)
Weight kg 2 2.1 2 2.1 1.8 1.9 1.8 1.9 1.7 1.8 1.7 1.8
*1 Conditions:Clean water, room temperature. *For details on the control functions, see "Control function specifications" on page 12.
*2 0.7MPa (7bar) for models w/relief valve(R type) whereas 1.0MPa (10bar) for models w/o relief valve.
*3 Provided for the DCLPW series only.
DCLPW/CLPW/CLPZ
O-ring Fluoro rubber Anti siphonal check valve 1 set (R1/2)
Valve seat Special fluoro rubber Foot valve −−− 1 set
Packing PTFE Cable ties (INSULOK®)
1piece
Joint PVC for relief hose (spare)*2
■External dimensions
●DCLPW/DCLPWM/DCLPWT ●CLPW/CLPWM/CLPWT ●CLPZ
(120)
86 77
76
OPE N
152
152
OPE N
Air release
185.8
32.8
(216)
(206)
76
76
109.8
ECO
140
SAFE
130
1/n mL/min
SAFE STOP ×n CAL
PL Manual strokes/min
1/n mL/min
STOP ×n CAL
34
8
30.2
74 16.5 75
7
16.5 70
118 20 75 118 118 118
7
R3 R3
87
87
6
6
87 87 87
22
Hypochlorite AR
For Sodium
Automatic Air-release
ARPZ No-input
Discharge
piping
Air release
The bubbles or gas pass
through the Air-release Injection Point (when liquid is not being injected)
joint and are fed back to Conventional check valve AR
the chemical tank along
Discharge the Air-release piping. Crystals The cap closes
Pump head
form due to to prevent
Main piping reaction with Main piping reaction w i t h
Hose joint Hose joint
Discharge (raw water) calcium in (raw water) raw water and
After all the bubbles or gas raw water. crystallization.
23
Specification The operation modes of the ARPZ is the same as those for the PZ, respectively.
Model ARPZ
Specif ication
31 61 12
mL/min 27 54 93
Max. discharge volume*
L/h 1.62 3.24 5.58
MPa 1.0 0.8 0.4
Max. discharge pressure*
bar 10.0 8.0 4.0
Stroke speed 15 to 300 strokes/min (dial setting)
Stroke length Fixed at 1.0 mm
4x9 6 x 11
Discharge side (PVC braided hose) (PVC braided hose)
6x8 6x8
Connection (PE) (PE)
(hose/tube: Suction side 1/4" x 3/8" 1/4" x 3/8"
I.D x O.D) (PE) (PE)
Air-release 4 x 8 (soft PVC hose)
Max. allowable viscosity 50 mPa . s
Allowable temperature Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed)
Ambient humidity 35 to 85% RH
Environmental protection IEC standard: IP65 or equivalent (water- and dust-proof)
Altitude of instrallation location Less than 1,000 m
Noise level Less than 85 dB
Rated voltage AC 100 to 240 V ( 10%)
Power No. of phases/Frequency 1-phase / 50 or 60 Hz
supply Maximum current 2.0 A 2.5 A
Power Max. 200 VA 250 VA
consumption Ave. 15 W 18 W
Weight 1.7 kg 1.8 kg
* Conditions: Clean water, room temperature
Also refer to the "Corrosion-resistance Table" on page 26. * 2 Only when PE tube is selected
Model Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material".
ARPZ
83
72
148
R3
(202)
6
76
8 130
87
(57) 70 118
110
(190)
24
Application examples
■Simple water purifying treatment ■Elevated water tank
Residual Control panel
chlorine meter
P
Residual
chlorine meter Circulation
Sampling valve pump
Feedwater P Elevated water tank Chemical injection system
Water lifting pump PTS
Level switch
Sampling valve
P P
ECO
SAFE
PL Manual strokes/min
1/n mL/min
STOP ×n CAL
SAFE
PL Manual strokes/min
1/n mL/min
STOP ×n CAL
Cooling tower
Boiler
ECO
SAFE
PL Manual strokes/min
1/n mL/min
STOP ×n CAL
P
Chemical PW Waste water
injection system Circulation
PTS pump
P
Control panel
panel
SAFE SAFE
Sodium hypochlorite
Chemical storage tank PW Dechlorination
injection system solvent tank PW
pH meter
PTS
Residual
chlorine meter
Water- Static
Static mixer storage mixer
Filter Filter RO
tank
Industrial water RO
Discharge
P P
High-pressure pump
Residual
Neutralization tank Tank with pH chlorine meter
recording instrument
25
Explanation
Digital Signal Also refer to "Specification" for each model.
Unassigned Selected ports not to be unassigned
Signal from an external device to reset the current value (count, time) during count operation (batch control) or
Input Reset/Restart signal
interval operation (timer control) and to restart operation
Alarm reset signal Signal from an external device to reset display/output of errors and alarms
Signal from the Level Switch installed in the tank to stop the pump operation
Level Switch signal*1
When 2-point Level Switch is used ... [Low tank-level alarm] "E-02" displayed and alarm output/ [Lower tank-level alarm] "STP" flashing display and pump stopped
Compulsive MAX operation signal Signal that forces the pump to run at MAX speed (300 strokes/min) regardless of operation mode
Unassigned Selected ports not to be unassigned
Solenoid-operation
One pulse signal to be output per stroke
sync pulse signal
In-operation signal Signal to be output during the operation (including "in standby")
Running signal Signal to be output during the pump is running (not including "in standby")
Operation end signal Signal to be output when the preset number of strokes is reached during count operation (batch control)
Output
Lamp a Alarm signal Signal to be output when one of the following errors and alarms is detected
Signal to be output when 2-point Level Switch is used and the volume of the chemical has fallen to the preset (low) level (Low tank-level alarm)
Tank-level alarm signal*1
For Lower tank-level alarm, "STP" flashing display and pump stopped. However, no signal is output
Pulse-Input error signal Signal to be output when the number of Pulse-Input signals momentarily exceeds the buffer size during Pulse-Input proportional control
Signal to be output when the Analog-Input signal goes outside of the specified range during Analog -Input proportional control
Analog-Input error signal
(In the case of the 4 to 20 mA range, 3 mA or less or 22 mA or more. In the case of the 0 to 20 mA range, 0 mA or less or 22 mA or more)
Tank-level alarm* 1
Alarm when the chemical volume has fallen to the preset (low) level
Error/
Alarm Pulse-Input error Error when the number of Pulse-Input signals momentarily exceeds the buffer size during Pulse-Input proportional control
Error when the Analog-Input signal goes outside of the specified range during Analog -Input proportional control
Analog-Input error
(In the case of the 4 to 20 mA range, 3 mA or less or 22 mA or more. In the case of the 0 to 20 mA range, 0 mA or less or 22 mA or more)
* When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids.
The corrosion resistance of materials is greatly affected by temperature, concentration, UV rays, and other environmental conditions. For this reason, this selection table does not completely guarantee safety.
The above figures are the corrosion resistance for pump liquid-end materials. Consult TACMINA separately regarding the corrosion resistance of hoses and tubes.
26
■ Options
● Degassing joint ● Flow checker ● Parts kit
Degassing joint is installed Flow checker is highly resistant Parts kit includes all required
at the suction side of a pump. to acid and alkalis and allows consumables in a set and is
It separates absorbed air the injection operation of more economical than purchasing
bubbles from the liquid to the pump to be checked at the parts separately. Since all
prevent air bubbles from low cost. The pump-direct consumables are packaged
entering the pump head. connection type and hose in one box, it also makes
*This joint is supplied with connection type are the two inventory management easier.
the DCLPW series as types of volume checkers
standard equipment. available.
● Residual pressure exhaustion valve ● Relief valve (safety valve) ● Back pressure valve
Residual pressure exhaustion Relief valve automatically Back pressure valve prevents
valve is directly connected to releases excessive pressure excessive liquid flow and
the discharge side of the pump that builds up inside the siphon effect by sealing the
so that the pipes can be safely discharge side pipes due to outlet port of the liquid with
purged of abnormal pressure clogging of the pipes or while a diaphragm, and by applying
that builds up. It also enables the discharge valve is closed. just enough force (back pressure)
residual pressure and residual It can prevent accidents such to overcome the fluid inertia
liquid to be safely discharged as damage to the pump or force.
when maintenance services piping.
are performed.
● Pulse generator type flowmeter ● Flow indicator and photoelectric sensor ● Float switch
When using this flowmeter These optional products enable Float switch will stop the pump
in combination with a Tacmina you to check the injection when the remaining volume of
pulse signal input type metering operation visually as well chemical liquid in the tank
pump, you can construct a as by means of a sensor. becomes low. They also cause
simple and low-cost injection an alarm to be emitted to
system proportional to the notify you that it is time to refill
required flow rate. the liquid. Two types of float
switches are available, namely
the float type with choices of
one-point and two-point type
sensors, and the electrode
type, which is highly resistant
to chemicals.
■ Related equipments
Pump and tank combination
Chemical injection system
PTS Tank
Tank capacity Tank capacity
30/50/120 L 25 to 1000L
●Compact design and easy to
assemble in equipment and
install.
●You can start operation by
simply connecting the power
supply and piping.
Product designs and specifications are subject to change without notice for product improvement.
EC-054 (5) 05