S001032-14 (Datalogger Specification)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

COMMENT STATUS

NO COMMENT NOT ACCEPTED


A PROCEED WITH FABRICATION - RESUBMIT WITH NEXT REVISION UP
C DO NOT FABRICATE - RESUBMIT CORRECTED DOCUMENT FOR
STAMPED AS MANUFACTURED APPROVAL WITH NEXT REVISION UP

ACCEPTED AS NOTED FOR INFORMATION


B PROCEED WITH FABRICATION IN ACCORDANCE WITH COMMENTS RESUBMIT
D
REFERENCE ONLY
CORRECTED DOCUMENT FOR APPROVAL WITH NEXT REVISION UP

Checker name : Date : Visa :

1 21/09/2005 First issue JLB JLB PM

Rev. Date Description of revision Originator Checker Lead Client visa

Owner:

THYNA PETROLEUM SERVICES

Client:

Mondial Contractor

Project name:
CPF metering skid & Fiscal Metering skid STEG Tie-in
Command n°:
AF98/BC5066/REP2005-08
Equipment:
Fiscal Metering skid STEG Tie-in

Document title:

Data logger specification

Supplier: Supplier document n°:

S 001032-14
MECI s.a.s.
Contractor Doc N° 5 I 04 12 1008 A4 01 Sheet:

1/2
CPF metering skid & Fiscal
CLIENT Mondial Contractor PROJECT
metering skid STEG Tie-in
Meci s.a.s
Supplier MECI SAS Contract N° A-001032
Rev. Date By Checked Specification N°& rev. S001032-14
1 21/09/2005 JLB PM Sheet N° 2 of 2
DATALOGGER
Purchase order N°
Refer to

Model LOG15 Tag n° 04FPTR01010C/04FPTR01011C


Quantity 2 Service 04SK100 Fiscal metering skid STEG Tie-in
Fluid designation Natural gas State gas
Flow (Nm3/h) min / max / design 1988 / 4363 19343 / 39308

Pressure (bar g) min / norm / max 20 69 76


OPERATING CONDITIONS Temperature (°C) min / norm / max 10 50
3
Density (kg/m ) min / norm / max 52,84 73,97
Location instrumentation room
Ambiant atmosphere Tunisian coast
24 V DC - 48 V DC - other internal battery
Power supply voltage
110 V AC - 220 V AC -
ambiant temperature -40 / +70°C
Condition for use
Humidity Up to 95 % without condensation
Consumption / running time 3 years
Safety certification EEx ia IIBT4
GENERAL Size 200x160x100 mm (l*h*p) Protection degree IP66
V850 micro processor 14.7MHz (32 bits)
internal flash memory 8 Mb
CPU board
external flash memory 32Mb
recording capacity 64000 records / 90 days for 3 data storage (TT,PT DPT) each 15 seconds
keyboard for the man / machine interface Two Key Keyboard for man / machine interface
LCD display 4 lines of 20 characters allow the operator to visualize the various data
Analog inputs : 4 inputs 4-20 mA
AI1 not used AI2 not used AI3 not used
AI4 not used AI5 not used AI6 not used
Temperature input : Pt100 at 0°C DIN 43760 Class A (CEI751) Converter 18 bits
Type of mouting 4 wires max cable length 50 m
Pressure input absolte pressure & differential pressure 1 absolute / 1 differential
absolute pressure transmitter Yes, integrated with 1/4'' NPT connector Range 0 to100bar
Yes, remote transducer with binder
differential pressure transmitter connector Range 0 /1300mbar
INPUT / OUTPUT Digital input / outputs : 8 assigned by configuration
D1 Not used D2 Not used D3 Not used D4 Not used
D5 Not used D6 Not used D7 Not used D8 Not used
Low Frequency inputs : 2 inputs Maximum frequency 10 Hz
CPT1 Meas No CPT1 Ctrl No
High Frequency inputs : 2 inputs Maximum frequency 5000 Hz
CPT1 Meas No CPT1 Ctrl No
Analog outputs : 2 output 0 / 2V Accuracy 0,20%
AO1 Not used AO2 Not used
Number of connection 2
RS232 Serial link number D1 PC link Yes
COMMUNICATION
RS422 Serial link number D2 Supervisory 1 Not used Rate 1200 to 19200 bauds.
COMPUTATION
Notes :

You might also like