b: Amplitude Time (a-t) curve rise and fall and then flattens.
c: amplitude frequency (a-f) curve ,the peak of after vibration is higher than before.
d: amplitude frequency (a-f) curve ,the peak of after vibration is left before.
before.
For the result,there are three results will be showed on the screen:
3,no show means the vibration is invalid,we should adjust the vibrator,sensor,pad or
eccentric;
if you vibrate the same frame for many times and the result always ok,it is normal,
and the vibrating time maybe will be shorter and shorter,as the residual stress was
relieved completely.
Operation
1.full-automatic mode(recommend)
a)turn on.
b)press the run/stop button,then the equipment work itself.
c)when the vibrating finished and the equipment stop completely,
press the print button to print result.
2.Plate-type workpiece(length is approximate with width,and length is 5 times than the thickness),the
rubber pads(4 pieces) are put on the point of 1/3 length from the end,the vibrator is put on the middle
or one end of one side,the sensor is put on the other end.
3.Square-type workpiece(the length,width and thinckness are approximate),two of them are put on
one side on the point of 1/3 length from the end,another is put on the middle of the other side,the
vibrator is put on the middle of side which only has one pad,the sensor is put on the othe end.this
type workpiece need 3 pads.
4.Round-type workpiece,the rubber pads(3 pieces) are put on the roundness averagely,the vibrator is
put on the middle of two pads,the sensor is put on the middle of the others two ones.
7.Large workpiece with heavy rigidity,it can be vibrated by certain rotating speed and tiem.
Result identify
There are two ways to identify if has obtained good result,one is the peak of curve
after vibrating is higher than the peak of curve before vibrating;the other is the
curve after vibrating on the left of curve before vibrating.
Of course,there is a word “ok” or “error” on the bottom of the printing paper,if “ok”
means good result,if “error” means not good result.then adjust it and vibrate again.
acceleration showing on the screen,if the acceleration being at 60 to 130 m/s*s,so the
eccentric is ok.
Turn on the equipment,press the up button two times,the motor start running,if the
acceleration can reach the range from 60 to 130 m/s*s,means the eccentric is ok,if less
60 m/s*s,adjust the eccentric for bigger one,if the acceleration is too higher more than
Note,
The eccentric should be less 120 degree,too higher degree will damage the motor.
How to set the the eccentric degree of vibratory stress relief equipment,
https://www.youtube.com/watch?v=ZpCJRSCXbt0