Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Table 25

Environmental Specifications
Environmental Specifications ECU: A4:M1 and A4:M3 Keypad Shifter
-40 °C to + 85 °C
Operating Temperature Range -40 °C to + 85 °C (-40 °F to 185 °F)
(-40 °F to 185 °F)
15.0 KHZ to 1.0 GHZ @ 100
Radiated Immunity 15.0 KHZ to 1.0 GHZ @ 100 V/M
V/M
-50 °C to +85 °C
Storage Temperature Range (Normal) -50 °C to 120 °C (-58 °F to 248 °F)
(-58 °F to 185 °F)
75 percent to 133 percent
75 percent to 133 percent (NSV) Nominal
Output Storage Tolerance (NSV) Nominal System
System Voltage
Voltage
Input Shortage Tolerance Between input and Batt-/Batt+ Between input and Batt-/Batt+
115 percent NSV, 90 percent
115 percent NSV, 90 percent relative
Humidity Tolerance relative humidity over operating
humidity over operating temperature range
temperature range
115 percent NSV with 5 percent
115 percent NSV with 5 percent salt spray
Salt Spray Tolerance salt spray for 48 hours at 38 °C
for 48 hours at 38 °C (100 °F)
(100 °F)
Diesel fuel, engine/machine
Diesel fuel, engine/machine oil, and SAE
Chemical Splash Immunity oil, and SAE J1455 chemical
J1455 chemical agents
agents
8 Gms random vibration
Vibration (Shock Isolated Components 8 Gms random vibration from 24 to 2000 Hz
from 24 to 2000 Hz in three
Tolerance) in three orthogonal planes
orthogonal planes
Moisture Leakage (Sealant Pressure 35 kPa (5 psi) against water
35 kPa (5 psi) against water and water vapor
Tolerance) and water vapor
Zero damage during exposure to
Electrostatic Environment N/A
electrostatic painting process

Table 26 The maximum torque allowed at the transmission


Environmental Hazardous Area Shifter: PTO pads is constant and the maximum power is
Specifications D3M3 Advisor speed dependent. Horsepower can be calculated by
-25 to +75 C (Display) -40 multiplying torque in ft lb times the rpm and dividing
Operating Temperature by 5252 The rpm is different at the engine and the
to +85 C (Electronics)
Storage Temperature -40 to +85 C
PTO pads. The power and speed limitations will most
likely be restricted by the aftermarket PTO and pumps
Sinusoidal Vibration 9.8g 24 - 1000 Hz selected, and not by the transmission capability..
Environmentally sealed to
Protection 34.48 kPa (5 PSI) IP68 / Any further inquiries concerning PTOs and pump
NEMA 13 Ingress Protection design should be directed to the Caterpillar
Drivetrain Systems Business Unit (Transmissions)
through the application support center. The
Power Take Off (PTO) web site for the Application Support Center is
http://applicationsupport.cat.com
The TH48-E70 Petroleum Transmission has three
power take off (PTO) options as shown in the Note: All references to the direction of rotation in this
Illustration 50 and 51 below. Bolt-on PTO units section are for the PTO gears when viewed from the
are available from aftermarket suppliers and can output end of the transmission.
be specified to adapt to various output options.
Specifying and designing the installation of the PTO
devices and related guarding is the responsibility of
the OEM, or the end user.

45