Steps_3rd - Ladder Diagram Page 1

TOOL6:MainTask:MainProgram 11/12/2022 23:16:15


Total number of rungs in routine: 32 C:\Users\JOSE LUIS\Downloads\TOOL6.ACD

Number of boxes into


the buffer
EQU check_one
0 Equal /
Source A MES_BufferResult
<bottles>
0
Source B number
1

Program sequence Vacuum in cups Number of boxes into


tag v the buffer
Step_Buffer[0].10 <Local:1:I.Data.13> Timer[4].DN GRT
/ Greater Than (A>B)
Source A MES_BufferResult
Program sequence Number of bottles
<bottles>
tag Rejected
0
Step_Buffer[0].12 Timer[5].DN CountRejected.DN
Source B number
/
1
Program sequence
tag
Step_Buffer[0].15 Timer[9].DN

Program sequence
tag
Step_Buffer[0].0
L

Program sequence Program sequence


tag tag
Step_Buffer[0].1 Step_Buffer[0].0
1 U

Bottle holder
Program sequence cylinder downward Program sequence
tag e1 tag
Step_Buffer[0].0 <Local:1:I.Data.8> Timer[6].DN Step_Buffer[0].1
2 L

Program sequence Program sequence


tag tag
Step_Buffer[0].2 Step_Buffer[0].1
3 U

Program sequence Program sequence


tag tag
Step_Buffer[0].1 Timer[0].DN Step_Buffer[0].2
4 L

Program sequence Program sequence


tag tag
Step_Buffer[0].3 Step_Buffer[0].2
5 U

Program sequence Program sequence


tag tag
Step_Buffer[0].2 Timer[1].DN Step_Buffer[0].3
6 L

Program sequence Program sequence


tag tag
Step_Buffer[0].4 Step_Buffer[0].3
7 U

Program sequence Program sequence


tag tag
Step_Buffer[0].3 Timer[2].DN Step_Buffer[0].4
8 L

Program sequence Program sequence


tag tag
Step_Buffer[0].5 Step_Buffer[0].4
9 U

Logix Designer
Steps_3rd - Ladder Diagram Page 2
TOOL6:MainTask:MainProgram 11/12/2022 23:16:15
Total number of rungs in routine: 32 C:\Users\JOSE LUIS\Downloads\TOOL6.ACD

Program sequence Program sequence


tag tag
Step_Buffer[0].4 Timer[3].DN Step_Buffer[0].5
10 L

Program sequence Program sequence


tag tag
Step_Buffer[0].6 Step_Buffer[0].5
11 U
Program sequence
tag
Step_Buffer[0].11

Program sequence Checker upward Checking analog is Program sequence


tag f0 OK Bottle in transfer tag
Step_Buffer[0].5 <Local:1:I.Data.9> Check_OK moving Step_Buffer[0].6
12 / L

Program sequence Program sequence


tag tag
Step_Buffer[0].7 Step_Buffer[0].6
13 U

Pusher cylinder
Program sequence line2-1 forward Program sequence
tag g1 tag
Step_Buffer[0].6 <Local:1:I.Data.11> Step_Buffer[0].7
14 L

Program sequence Program sequence


tag tag
Step_Buffer[0].8 Step_Buffer[0].7
15 U

Program sequence Vacuum in cups Program sequence


tag v tag
Step_Buffer[0].7 <Local:1:I.Data.13> Step_Buffer[0].8
16 L

Program sequence Program sequence


tag tag
Step_Buffer[0].9 Step_Buffer[0].8
17 U

Bottle holder
Program sequence cylinder upward Program sequence
tag e0 tag
Step_Buffer[0].8 <Local:1:I.Data.7> Timer[10].DN Step_Buffer[0].9
18 L

Program sequence Program sequence


tag tag
Step_Buffer[0].10 Step_Buffer[0].9
19 U

Pusher cylinder
Program sequence line2-1 backward Program sequence
tag g0 tag
Step_Buffer[0].9 <Local:1:I.Data.10> Timer[11].DN Step_Buffer[0].10
20 L

Program sequence Program sequence


tag tag
Step_Buffer[0].0 Step_Buffer[0].10
21 U

Program sequence Checker upward Checking analog is Program sequence


tag f0 OK tag
Step_Buffer[0].5 <Local:1:I.Data.9> Check_OK Step_Buffer[0].11
22 / L

Program sequence Program sequence


tag tag
Step_Buffer[0].12 Step_Buffer[0].11
23 U

Logix Designer
Steps_3rd - Ladder Diagram Page 3
TOOL6:MainTask:MainProgram 11/12/2022 23:16:15
Total number of rungs in routine: 32 C:\Users\JOSE LUIS\Downloads\TOOL6.ACD

Bottle holder
Program sequence cylinder upward Number of bottles Program sequence
tag e0 Rejected tag
Step_Buffer[0].11 <Local:1:I.Data.7> CountRejected.CU Timer[12].DN Step_Buffer[0].12
24 L

Program sequence Program sequence


tag tag
Step_Buffer[0].0 Step_Buffer[0].12
25 U
Program sequence
tag
Step_Buffer[0].13

Program sequence Number of bottles Program sequence


tag Rejected tag
Step_Buffer[0].12 Timer[5].DN CountRejected.DN Step_Buffer[0].13
26 L

Program sequence
EMERGENCY_STEP tag
Step_Buffer[0].14 Step_Buffer[0].13
27 U

Program sequence Emergency Stop


tag em EMERGENCY_STEP
Step_Buffer[0].13 <Local:1:I.Data.14> Step_Buffer[0].14
28 L

Program sequence
tag EMERGENCY_STEP
Step_Buffer[0].15 Step_Buffer[0].14
29 U

Reset push button Program sequence


EMERGENCY_STEP r tag
Step_Buffer[0].14 <Local:1:I.Data.3> Step_Buffer[0].15
30 L
Reset from SCADA
SCADA_r
<SCADA_Workbits.2>

Program sequence Program sequence


tag tag
Step_Buffer[0].0 Step_Buffer[0].15
31 U

(End)