UV/ VIS Spectrophotometer

Features
> Excellent stability > Powerful buit-in or PC windows based software
> Fixed or variable slits including sophisticated utility programs
> Large LCD screen > Auto 8 cell holder
> Pre-aligned deuterium lamp

X-ma 3000 Series!


Innovative optical system,
high performance.

Model : X-ma 3000 Series

X-ma 3000(PC) X-ma 3100(PC) X-ma 3200(PC)


Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 2.5 nm 2.0 nm 1.8 nm
Optical System Single beam, Grating 1200 lines/mm
Wavelength Accuracy ±0.5 nm ±0.5 nm ±0.3 nm
Wavelength Repeatability 0.3 nm 0.3 nm 0.2 nm
Scanning Speed Hi, Med, Low. Max 3000 nm/min
Photometric Accuracy ±0.3 %T ±0.3 %T ±0.2 %T
Photometric Repeatability ±0.2 %T ±0.2 %T ±0.15 %T
Photometric Range -0.3 to 3.0A / 0 to 200%T / 0 to 9999C
Stray Light ±0.05 %T
Stability ±0.002 A/h ±0.002 A/h 0.001 A/h
Display Large LCD Display (W100×H78mm, 5inch) or PC Model
Baseline Flatness ±0.002A ±0.002A ±0.001A
Sample Compartment Auto 8 cell holder
Light Source Halogen & Deuterium lamp (Pre-aligned)
Output USB Port & Parallel Port (Printer)
Power Requirement 220/110V, 60/50 Hz
Dimensions (W×D×H) 480×360×160 mm
Weight 16 kg
Performance 1. Basic Mode Absorbance, Transmittance or concentration measurements
2. Quantitative Establish or use stored calibration equation to measure the concentration of unknowns
3. WL scan Spectrum scan of sample at any selected wavelength range with choice of
scanning speed and wavelength interval
4. Kinetics Measurement of absorbance changing vs. time with reaction rate calculation function
5. Multi Wavelength Measurement at multiple wavelengths to analyze and determine the composition of the mixtures
6. DNA/Protein Calculation of concentration and DNA purity. Ratio at other wavelengths can be measured
Optional Accessories •3, 5, 10 cm 4-cell holder •Test tube holder
•Micro cell holder •Printer
•Water-jacket cell holder •Cell
•Ambient sipper/ Peltier system

All specifications are subject to change without notice


18
Control Software for X-ma 3000 Series
The PC application software offers
> Basic Photometric Mode > DNA/Protein
> Quantitativetest (standard curve) > Multi-wavelength Test
> Wavelength Scanning > System Utility
> Kinetics

Multi-wavelength Kinetics (Abs vs. Time)


Up to 32 wavelengths can be selected and The Kinetics mode may be used for time course scanning or reaction
multiple samples can be measured. (Auto cell rate calculations. Abs. vs. time graphs is displayed on the srceen in real time.
changer is required to run multiple samples Wait time, measurement time and time intervals may be entered. Post-run
auto-matically) manipulation includes re-scaling,curve tracking and selection of the part of
the curve required for the rate calculation. Rate is calculated using a linear
regression algorithm before multiplying by the entered factor.

Quantitative Test (standard Curve) DNA/Protein


Use up to 32 standards to establish standard Concentration and DNA purity are quickly and easily calculated :
curve. Four methods for fitting a curve : Absorbance ratios 260nm/280nm with optional subtracted
1. Linear fit absorbance at 320nm.
2. Linear through zero DNA concentration = 62.9 X A260 - 36.0 X A280
3. Square fit Protein concentration = 1552 X A260 - 757.3 X A280
4. Cubic fit other wavelengths and factors may be entered.

Wavelength Scanning
Automatically record peaks and valleys. The quantity of
channels is unlimited, you can simultaneously store curves
www.humancorp.co.kr

as many as you want.


Post-run manipulation and processing includes :
1. Re-scaling axes, curve
2. 1st to 4th derivative
3. Smoothing, combination, zooming, overlap ...

19
UV/VIS Spectrophotometer
Features
> Built-in USB/Parallel port > Standard curve/coefficient function
> Graphic LCD (128X64) Display > 200 STD curve data save function
> Auto calibration function

X-ma 1000 Series!


Simple and User Friendly System,
Economic Price.

Model : X-ma 1000/1200

X-ma 1000 X-ma 1200 X-ma 1200V


Wavelength Range 200 to 1000 nm 325 to 1000 nm
Wavelength Accuracy ±2 nm ±1 nm
Repeatability 1 nm 0.5 nm
Resolution 0.1 nm
Photometric Accuracy ±0.5 %T
Repeatability ±0.3 %T
Range •Abs : -0.097 to 1.999 •Abs : -0.097 to 2.5
•%T : 0 to 125 •%T : 0 to 125
•Conc : ± 9999 •Conc : ±9999
Spectral Bandwidth 2 nm
Optical System •Single beam.
•Grating 1200 lines/mm
Stray Light ≤0.3 %T
Stability ±0.004 A/h @ 500 nm ±0.002 A/h @ 500 nm
Display Graphic LCD (128×64 dots) Display, 65(W)×35(H) (3″ )
Key board Microprocessor one touch membrane key ped
Detector Silicon Photodiode
Sample Cell Holder 4 Cell Holder
STD curve NO 1 STD Sol'n (20 with software) 9 STD Sol'n (20 with software)
Data Memory 200 STD curve data memory
Light Source Tungsten & Deuterium lamp Tungsten lamp
Output USB Port, Parallel Port (Printer)
Power AC 220V, 50/60Hz
Dimensions (W × D × H) 480×360×160 mm

All specifications are subject to change without notice


20
Control Software for X-ma 1000/1200
Enjoy the quality with the exceptionally good price!

User Friendly Design offers ease of use and simple maintenance

•Self-test •Measurement •STD Calibration

Analysis Program with Software

•Quantitative Analysis •Kinetic measurement

Optional Accessories

•Auto 8 cell holder •50 mm cell holder •100 mm cell holder •Cylindrical Cell Holder
www.humancorp.co.kr

•Tube holder •Micro cell holder •Single water jacket cell holder •Solid sample holder

21
Quartz Glass cell
With top class quality, but most effective price.

① ②

with PTFE lid

No Dimensions Light path Volume UV grade Glass grade


(W×D×H)mm /inside W (ml) (170mm ~ ) (320mm ~ )
Quartz Glass
① 12.5×12.5×45 10/10 3.5 Q - 104 G - 104
STD Cell Fluorescent Cell ② 12.5×12.5×45 10/10 3.5 Q - 204 G - 204

with PTFE lid

No Dimensions Light path Volume UV grade Glass grade


(W×D×H)mm /inside W (ml) (170mm ~ ) (320mm ~ )
① ② ③ Quartz Glass
① 12.5×7.5×45 5/10 1.7 Q - 103 G - 103
② 12.5×22.5×45 20/10 7.0 Q - 105 G - 105
③ 12.5×32.5×45 30/10 10.5 Q - 106 G - 106
④ 12.5×42.5×45 40/10 14.0 Q - 107 G - 107
⑤ 12.5×52.5×45 50/10 17.5 Q - 108 G - 108
⑥ 12.5×102.5×45 100/10 35.0 Q - 109 G - 109

with PTFE lid


① ②
No Dimensions Light path Volume UV grade Glass grade
(W×D×H)mm /inside W (ml) (170mm ~ ) (320mm ~ )
Quartz Glass
① 12.5×12.5×45 10/1 0.35 Q - 234 G - 234
② 12.5×12.5×45 10/2 0.7 Q - 244 G - 244
③ 12.5×12.5×45 10/3 1.0 Q - 254 G - 254
④ 12.5×12.5×45 10/4 1.4 Q - 264 G - 264
Micro Cell with Frosted Walls ⑤ 12.5×12.5×45 10/5 1.7 Q - 274 G - 274

with PTFE lid


① ②
No Dimensions Light path Volume UV grade Glass grade
(W×D×H)mm /inside W (ml) (170mm ~ ) (320mm ~ )
Quartz Glass
① 12.5×12.5×45 10/1 0.35 Q - 124 G - 124
② 12.5×12.5×45 10/2 0.7 Q - 44 G - 44
③ 12.5×12.5×45 10/3 1.0 Q - 134 G - 134
④ 12.5×12.5×45 10/4 1.4 Q - 24 G - 24
Micro Cell with Black Walls ⑤ 12.5×12.5×45 10/5 1.75 Q - 144 G - 144

22
Quartz Glass cell
With top class quality, but most effective price.

with PTFE lid

No Dimensions Light path Volume UV grade Glass grade ① ②


(W×D×H)mm /inside W (ml) (170mm ~ ) (320mm ~ )
Quartz Glass
① 12.5×12.5×45 10/10 3.5 Q - 214 G - 214
② 12.5×12.5×45 10/1 0.35 Q - 374 G - 374
③ 12.5×12.5×45 10/2 0.7 Q - 284 G - 284
④ 12.5×12.5×45 10/3 1.0 Q - 384 G - 384
⑤ 12.5×12.5×45 10/4 1.4 Q - 294 G - 294
⑥ 12.5×12.5×45 10/5 1.7 Q - 394 G - 394 STD Cell Micro Cell with Frosted Walls

① ②

with PTFE lid

No Dimensions Light path Volume UV grade Glass grade


(W×D×H)mm /inside W (ml) (170mm ~ ) (320mm ~ )
Quartz Glass
① 12.5×7.5×45 5/2 0.35 Q - 53 G - 53
② 12.5×12.5×45 10/2 0.7 Q - 54 G - 54
③ 12.5×12.5×45 10/4 1.4 Q - 34 G - 34 Micro Cell with Black Walls

with PTFE lid

No Dimensions Light path Volume UV grade Glass grade


(W×D×H)mm /inside W (ml) (170mm ~ ) (320mm ~ )
Quartz Glass
① 12.5×7.5×45 5/4×12 0.24 Q - 73 G - 73
② 12.5×12.5×45 10/4×12 0.48 Q - 74 G - 74
③ 12.5×22.5×45 20/4×12 1.0 Q - 75 G - 75
④ 12.5×32.5×45 30/4×12 1.5 Q - 76 G - 76 Self marking continous flow through cell

with PTFE lid


www.humancorp.co.kr

No Dimensions Light path Volume UV grade Glass grade


(W×D×H)mm /inside W (ml) (170mm ~ ) (320mm ~ )
Quartz Glass
① Ø22×12.5 10/Ø19 2.8 Q - 85 G - 85
② Ø22×22.5 20/Ø19 5.7 Q - 86 G - 86
③ Ø22×52.5 50/Ø19 14.0 Q - 87 G - 87
④ Ø22×102.5 100/Ø19 28.0 Q - 88 G - 88 Cylindrical Cell
All specifications are subject to change without notice