Professional Documents
Culture Documents
HA-SSDAC-G36R-Auto Reset
HA-SSDAC-G36R-Auto Reset
HA-SSDAC-G36R-Auto Reset
Overview Features
G36R is a fail-safe, reliable and user-friendly Communication using V.23 FSK modem with
2x2oo2 architecture based axle counting cable loss of 30dB
system Built-in event-logger logs up to 14000 events
RDSO approved Train detection up to 250Kmph
Complies with RDSO/SPN/177/2012 Ver 3.0 24VDC working
Meets CENELEC SIL-4 standards Protected against lightning surges
Configuration Stable operation at –10 to 70oC and RE area
2DP-1SR — Single Section Block proving 2 Independent safety electronics in a single card
frame for high availability
Strength
2 separate output Vital Relays for paralleling to
No TP circuit required for push trolley with achieve highest availability
spoke wheel
Configurable as common wheel sensing
Scalable to higher configuration with same detectors for both axle counting electronics
hardware and software
Reset
Protection against wrong configuration at site
Co-operative — Preparatory mode piloting
Direct — With/without Line Verification
System
Microprocessor based fail-safe embedded system
Detection of axles and direction of train movement
Fixed pair communication, CRC check & unique addressing
of units ensures fail-safety
User friendly GUI aids to download events via RS232 port
Units are housed in location boxes near the tracks
Axle Detectors
Web mounted on track, works with 90-R, 52Kg, 60Kg rails
Phase detection principle employed
Signals fed at 21Khz and 25Khz to Tx coils at 60V RMS
Axles above 550mm are detected
Automatic Reset
Automatic Reset Philosophy
Any failure of single SSDAC initiates Resetting
automatically to normalise the failed SSDAC
without affecting system working
Manual Resetting required only when both
SSDAC fails
Reset configurable either with or without
piloting
Auto Resetting counter for analysis
VPR1
VPR2 Electronic
V
PPR1
P 24V DC V V LAG
RTSR
TIMER
10 sec
& Auto Reset Counter
0.2 to 10
VPR1 VPR2 sec
PPR1
VPR1
V
VPR2 PPR2
N 24V DC V V
RTSR
P 48V DC
V VR1
V PR1
V
RTSR TO System 1
N 48V DC V VR1
V PR1
V
Reset
VR2 PR2
V V
Manual Reset circuit TO System 2
VR2 PR2
Reset
V V
About us Our Strength
Established in 1991 Design, Manufacture, Supply, Installation and
Commissioning of Safety Embedded Systems
We value Customers, professionalism, quality,
In-House Embedded System R&D
safety and ethical business practices
Safety System design capability
Meeting challenges is a way of life
Product Engineering with PCB and mechanical
Vision design facility
To be a leading solution provider right from Hardware and Software safety validation
design, development, manufacture, testing and
System Hazard Analysis
Commissioning in Railway Signaling and
Industrial Automation sectors Reliability Analysis
Incoming and Outgoing Quality Assurance
Mission
In-House Automatic Testing of PCB’s using In-
Committed to satisfy customer expectations Circuit Tester
with a focus on continuous improvement
In-House Environmental Stress Screening
Our People Antistatic protected SMD and Leaded
Inherent competency and committed team of components production line
professionals in respective domains In-House mechanical fabrication and Panel
building
“To provide value added products and services to the automation and transport control
Sectors by continuously upgrading technology quality and reliability”
Total commitment by management for Quality Assurance right from Design, Development, Production,
Supply, Installation and Commissioning Products meet environmental specifications laid by customers