20220902-Structural Drawing For 40'x30', EAST KYISU, DAGONSEIKKAN

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 29

STRUCTURAL DRAWINGS

OF

THREE STOREYED R.C.C BUILDING


(40'-0" X 30'-0")
BASIC EDUCATION MIDDLE SCHOOL, EAST KYISU,
DAGON SEIKKAN TOWNSHIP

SEPTEMBER, 2022
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

DRAWING LIST

NO. DESCRIPTION SHEET NO. TOTAL REMARK

1 COVER AND DRAWING LIST & DESIGN INFORMATION 3

2 GENERAL NOTES GN-1~6 6

3 ALL PLANS S101~110 10


OWNER

4 ALL SCHEDULES S201~203 3


PROJECT THREE STOREYED R.C.C BUILDING
5 FOOTING DETAILS S301 1 (40'-0" x 30'-0")

BLOCK NO.

6 RETAINING WALL , GROUND BEAM &SLAB DETAILS S302 1 LOT NO.

7 COLUMN SECTION S303 1 SUBJECT

DRAWING LISTS
8 BEAM SECTION S304 1

9 STAIR SECTION S305 1 SCALE N.T.S SHEET NO.


DL
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
10 ROOF TRUSS SECTION AND DETAIL S306-307 2

TOTAL NOS. OF SHEET - 29

PE/RSE (CONSTRUCTION)

LC

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

DESIGN INFORMATION

1. Design Load 3. Designed Material Strengths


A. Dead Load A. Concrete Strength
f c' =2500 psi
- Unit Weight of Concrete 150 lb/ft². OWNER

- 4 1 2" Thick Brick Wall Weight 50 lb/ft². B. Steel Reinforcement


- Floor Superimposed Dead Load 20 lb/ft². f y = 60000 psi
PROJECT THREE STOREYED R.C.C BUILDING
- Stair Superimposed Dead Load 45 lb/ft². f ys= 40000 psi (40'-0" x 30'-0")

C. Structural Steel Strength BLOCK NO.


fy = 36 ksi LOT NO.
fu = 58 ksi
SUBJECT

B. Live Load DESIGN INFORMATION

- Floor Live Load 40psf 4. Structural Analysis & Design Software


- Stair Live Load 100 psf A. ETABS V 9.7.1 SCALE
3
16"=1'-0" SHEET NO.
DI
- Roof Top Live Load 20 psf B. SAFE V 8.0.1 DATE SEPTEMBER,2022
C. Hand calculation with excel spread sheet PE/RSE (STRUCTURE)

2. Reference Codes
A. ACI 318-05/IBC-2006 PE/RSE (CONSTRUCTION)
B. ASCE7-05
C. MNBC-2020

LC

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

The General Notes shall be read in conjunction with the contract Specifications and Drawings.
GENERAL Regardless of whether or not shown in Drawings or other tender documents, the standard
provisions specified hereunder for compliance by The Contractor shall apply to all relevant
NOTES portions of the Structural Works and shall form part of this Contract.

1.0 VERIFICATION OF DIMENSIONS AND LEVELS

The Contractor shall verify all dimensions and levels on site, and resolve all discrepancies with the Architect or Engineer
prior to commencement of work. Drawing indicates general & typical details of construction. Where conditions are of
similar character to details shown and although not specifically indicated, similar details of construction shall be used
subjected to review by the Engineer. shall verify all dimensions and levels in the contract drawings. Prior to
commencement of works, The Contractor Discrepancies in drawings arising from such verification works shall be brought
to the attention of the Architect/Engineer.

2.0 SHOP DRAWINGS OWNER

The Contractor shall be solely responsible for ensuring total coordination of all works and shall take site measurements
of any shop drawings or before commencing fabrication. prior to the preparation The Contractor shall submit shop PROJECT THREE STOREYED R.C.C BUILDING
drawings for all specialist trades, such as prestressing, curtain walling, etc. for reviews and comments by the (40'-0" x 30'-0")
Architect/Engineer prior to commencement of work. Such shop drawings submitted shall members such as cast-in
BLOCK NO.
inserts, embedded plates, etc. incorporate all necessary connection details to the structural
LOT NO.

3.0 INCORPORATION OF M & E REQUIREMENTS IN THE STRUCTURE


SUBJECT
The Contractor shall be solely responsible for ensuring total coordination of Structural, M & E penetration drawings of
GENERAL NOTE
services and submit suchshop drawings to the Architect/Engineer for reviews and approval prior to commencement of work.
These shop drawings shall incorporate all mechanical, electrical and sanitary works to be embedded in concrete and all
openings for all pipe or duct works, based on the requirements of M & E drawings in his possession. 3
SCALE 16"=1'-0" SHEET NO.
He shall check and resolve all discrepancies with the respective Engineer prior to placement of concrete. GN-1
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
4.0 LEAN CONCRETE FOR SUSPENDED STRUCTURES

Unless otherwise stated,3 in thick lean concrete with the ratio of 1:3:6
shall be provided on all soil surfaces forming the underside of structural concrete members.

5.0 STRUCTURAL ELEMENTS ON GRADE

Unless otherwise stated, a single layer of 0.25 mm (heavy duty) polythene sheet, or equivalent thermoplastic material, laid
over a compacted 8 in thick layer of hard core blinded with sand to prevent grout loss from seepage into PE/RSE (CONSTRUCTION)
the ground shall be provided on all soil surfaces forming the underside of the non-suspended slabs.

6.0 SUBGRADE UNDER STRUCTURAL ELEMENTS

Where The Contractor requires removal and subsequent backfill of subgrade prior to casting of pilecap/wall/beam/slab,
he shall ensure that the backfill is of approved material and that the backfill shall be reasonably compacted to ensure that
the compacted soil is able to withstand the weight of the wet concrete. The Contractor shall exercise proper skill and care
to avoid damage to adjacent installed structures arising from his construction sequence. LC

7.0 WATERPROOFING FOR STRUCTURES

The Contractor shall submit shop drawings and method statements for the Engineer's approval prior to commencement
of work. Required shop drawing details include but are not limited to treatment of flashings, waterstop at construction
joints, wall and slab penetrations.

All penetrations through structural elements shall be cast-in, sleeved and provided with approved puddle flange detail.
OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

Intermediate Moment-Resisting Frame Detailing


(a) Columns & Shear Wall (b) Beams ρ 3 f 'c / f y > 200/ f y
min =
ρ 0.3643 β f 'c / f y
Joint reinforcement max = 1

_ _
M n, l M n, r

OWNER
A A
s<2s
0 PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")
Larger of C1 or C2 _
See note below + BLOCK NO.
M n,l > M n,l /3
l > Clear height /6 LOT NO.
0 Transverse reinforcement in _
+
18" accordance with ACI M n, r > M n, r /3
Sec.21.3.5 _ SUBJECT
+
β = 0.85 for f ' < 4000 psi
1 c M n or M n > (max. M n at either joint)/5
GENERAL NOTE
8 x longitudinal bar diameter = 0.80 for f 'c = 5000 psi (Note : Transverse reinforcement not shown for clarity)
24 x tie bar diameter
3
< s /2
s0 <
0.5 x (smaller of C1 or C2 )
Fig. Flexural requirements for beams SCALE 16"=1'-0" SHEET NO.
GN-2
0 DATE SEPTEMBER,2022
d/4
12" PE/RSE (STRUCTURE)
8 x smallest long. bar diameter
s<
24 x hoop bar diameter
12"
< 2"
Hoops Stirrups with seismic hooks

C PE/RSE (CONSTRUCTION)
2 h

C1
Section A-A
Note: There is no restriction on the location of longitudinal 2h
barsplices for intermediate moment frames. The s < d/2 LC

splice may be located away from the potential


Transverse reinforcement determined in
hinge regions (i.e., near the joints) as shown accordance with ACI Sec. 21.3.4 at both ends
above.
Fig. Transverse reinforcement requirements for columns & shear walls Fig. Transverse reinforcement requirements for beams
Ref : U Nyi Hla Nge ; "Refresher Course And Field Reference Manual For Site Engineers & Inspectors " ; 1st edition, 2010.
OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

Simplified Cutoff Points Beam Splice Column Splice


0.3 L1 0.3 L1 *
24" for 12mmØ bars 20" for 12mmØ bars
31" for 16mmØ bars 26" for 16mmØ bars D
R.C
column 1 35" for 18mmØ bars 29" for 18mmØ bars
< ( total +ve A
2 s )

Splice Length
or R.C wall cutoff
0.125 L1 0.125 L1 37" for 20mmØ bars 32" for 20mmØ bars
L1
* If adjacent spans are different in span lengths, use the larger of the two. 45" for 22mmØ bars 42" for 22mmØ bars
( 1 ) Do not splice more than 50% of the total at any section.
51" for 25mmØ bars 48" for 25mmØ bars
( 2 ) Do not splice any bar within the cantilever span. 9D
( 3 ) Lapping length = 40 x Main bar diameter.
OWNER
Splice Location for Beams
Splice Length PROJECT THREE STOREYED R.C.C BUILDING
>2h >2h (40'-0" x 30'-0")
Exterior column with large offset BLOCK NO.
h
LOT NO.

Splice Zone
SUBJECT
Top bars are not to be spliced: Fig. Splice Location for Top Bars
GENERAL NOTE
* Within joints.
Lap
* Within a distance of twice the member depth from the face of the joint. splice 3
s If 3" or more, use dowel bar SCALE 16"=1'-0" SHEET NO.
* At locations where analysis indicates flexural yielding caused by inelastic lateral displacements of the frame. GN-3
s DATE SEPTEMBER,2022
2
Splice Zone PE/RSE (STRUCTURE)
s
2
Not more than s Lap
h in exterior joints splice

Offset bend
Splice Length
>2h s Closed tie
L c /3 L c /3 L c /3
Bottom bars are not to be spliced: PE/RSE (CONSTRUCTION)
Lc Dowel bar
* Within joints. Fig. Splice Location for Bottom Bars

* Within a distance of twice the member depth from the face of the joint. Compression Development Length , ldc
* At locations where analysis indicates flexural yielding caused by inelastic lateral displacements of the frame.
2.5 fc' (ksi), 60 f y (ksi) = 24.0 d (Modify if applicable)
b
* At the beams that supporting the secondary beams, if possible.
* At mid span. Modification factors ( to multiply ) :
LC
Tension Development Length , ld (i) A s, required / A s, provided

2.5 f c' (ksi), 60 f y (ksi) = 48.0 db (for < 20mm bars) Modification factors = As, required (ii) If confined, i.e., if No.4 ties at not more than 4 in.c/c
As, provided
2.5 f c' (ksi), 60 f y (ksi) = 60.0 db (for > 22mm bars) (to multiply) spacing is provided, may be modified with 0.75
l d > 12 in. (in all
* For top bars multiply by 1.3 (Modify if applicable) cases) (iii) l dc > 8 in. (in all
cases)
Ref : U Nyi Hla Nge ; "Refresher Course And Field Reference Manual For Site Engineers & Inspectors " ; 1st edition, 2010.

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

End Anchorage Lengths


(A) Using Standard Hooks (B) Using Alternative Method (based on total length-less desirable and only for use when
(a) Beam - Column Connections (b) Beam - Girder Connections space is not adequate for standard hook ldh )
( using standard hooks ) ( using standard hooks )

la1 > ldh > 8d b or 6 in. (a) Beam - Column Connections (b) Beam - Girder Connections
la1 > ldh > 8d b or 6 in.
( using alternative method ) ( using alternative method )

clear cover clear cover l a2 > ldh + 14 db


l a2 > ldh + 14 db

l b2 > ldh + 14 db

l b2 > ldh + 11 db
> 2 in. > 2 in.
Primary beam
Column (girder)
OWNER

lb1 > ldh > 8d b or 6 in.


b1l >dhl 8d b or 6 in. Primary beam PROJECT
Column THREE STOREYED R.C.C BUILDING
clear cover clear cover (girder) (40'-0" x 30'-0")
Note : Modification factors may be applied to hb
l values
> 2 in. > 2 in.
BLOCK NO.
as explained in Section (9) to find dhl values. > 6 in. or 8 d b
> 6 in. or 8 d b LOT NO.

Note : In case the width of column or primary beam Note : Clear end cover > 2 in. for both top and bottom
90° hooks in all cases. Note : Clear distance between layers of SUBJECT
(girder) is not large enough to containdhl but of it beams reinforcement must not be
is desired to keep the same bar size , then , as an Note : In most cases under gravity loads only, for the bottom less than 1 in. and the bars in the GENERAL NOTE
upper layer should be place
alternative , the following less desirable method bars, a standard hook with > 6 in. inside the column
directly above those in the lower
3
of anchoring based on total length may be used or primary beam is recommended even though it is layer . Bars in beams must be SCALE 16"=1'-0" SHEET NO.
GN-4
placed symmetrically about the DATE SEPTEMBER,2022
[ Sect. 10 (B) ] . If it is still impossible to place the allowed not to use the hooks at all ; l may be
b2 vertical centerline. PE/RSE (STRUCTURE)
hook in the girder , reduce the bar size in order to neglected for such a case. For cases with possible
reduce the required anchorage length. stress reversal , l must
b2
be provided , however.

Anchorage Length Available in a Primary Beam (Girder) l max≈ b + h - 5.875 - 2.5 d b(in.) (for the outermost layer)
l max ≈ b + h - 5.875 - 6.5 d b (in.) (for the second layer)
1.875 in. l ≈ b + h - 5.875 - 10.5 d b (in.) (for the third layer)
b max
db = diameter of main bar, in.
h, b = depth and width of primary beam, respectively, in. PE/RSE (CONSTRUCTION)
l max
h BAR SPACING ( for maximum size of aggregate 1 inch )
Type of member Minimum clear spacing Maximumc/c spacing
2 in. Secondary Beam 113" _
2 in. clear Secondary Primary beam ( Girder ) beam
Primary beam beam Column 112 d b (or) 112" _
( Girder )
3h (or) 18" (one-way slab) LC
3"
Slab/Stair (to save labour) 2h (or) 18" (two-way slab)
Temp.& shr.steel : 5h (or) 18"

Ref : U Nyi Hla Nge ; "Refresher Course And Field Reference Manual For Site Engineers & Inspectors" ; 1st edition, 2010.

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

℄ OF SUPPORT ℄ OF SUPPORT ℄ OF SUPPORT


SPAN L1 SPAN L2 SPAN L3
R.C col: or
R.C wall 0.33 L1 0.33 L1 0.33 L2 0.33 L2
Greater Greater Greater
2h LAPPING AREA (Top) 2h 2h LAPPING AREA (Top) 2h
(Mid Span) (Mid Span)
R.C col: or R.C col: or
Bars To Bend When Not
S < d/4 R.C wall
Required On Adjacent Span S < d/4 R.C wall
2'' 4'' 2'' 2'' 4'' 2'' 2''
4''
Ld1
Ld2=ldh+14db

h
MIDDLE BAR MIDDLE BAR
S < d/4 < d/4 S S < d/4 < d/4 S
4'' 4'' 4'' 4''

OWNER
ldh 0.125 L1 0.125 L1 0.125 L2 0.125 L2
6'' or 8d b LAPPING AREA (Bott:) LAPPING AREA (Bott:)
(2h From Support) (2h From Support) PROJECT THREE STOREYED R.C.C
BUILDING (40'-0" X 30'-0")
TYPICAL CONTINUOUS SPAN BEAM
BLOCK NO.
Anchorage Lengths (Beam - Column Connections)
Col Left Mid Right Col LOT NO.
fc' = 2.5 ksi fc' = 3.3 ksi fc' = 4.06 ksi fc' = 4.6 ksi Beam
Bar Dia,d b fy ( ksi ) fy ( ksi ) fy ( ksi ) fy ( ksi ) Right
Left Mid

Right

Right
SUBJECT

Right

Right
(in , mm) 40 50 60 40 50 60 40 50 60 40 50 60
Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 Ld1 Ld2 GENERAL NOTE
3/8 10 16 13 20 13 25 13 15 13 18 13 22 13 13 13 17 13 20 13 13 13 16 13 19 13

Mid

Mid

Mid

Mid
1/2 12 20 13 25 13 30 16 18 13 22 13 26 14 16 13 20 13 24 13 15 13 19 13 22 13

Beam

Beam
5/8 16 26 13 33 13 40 21 26 13 28 15 35 18 21 13 26 13 31 16 20 13 25 13 29 16 3
SCALE 16"=1'-0" SHEET NO.
3/4 20 33 17 41 17 49 26 28 15 36 19 43 23 26 14 33 17 39 20 25 13 31 16 37 19 GN-5
DATE SEPTEMBER, 2022
7/8 22 37 19 46 23 54 28 32 17 40 21 47 25 29 16 36 19 43 22 27 14 34 18 40 21

Left

Left
PE/RSE (STRUCTURE)

Left

Left
1 25 41 23 51 27 61 32 36 19 45 23 54 28 33 18 41 21 49 25 31 16 38 20 46 24

BEAM DETAIL SAMPLE & ANCHOR LENGTH Left Mid Right


Col Beam Col
2'-3" Left Mid Right

h
6"
15" or 1.5h"
FB
FB
PE/RSE (CONSTRUCTION)
h 0'-3"
TYPICAL SECTION OF SLABS TOP LEVEL DIFFERENCE

FB
FB
2-16mm Ø Steels
TYPICAL SECTION OF SLABS TOP LEVEL DIFFERENCE

LC

2"~ 3" 0'-6"


h

FB h
FB FB 0'-6" 24 x ∅
FB 2"~ 3" FB
FB
24" or 2h"
18" or 1.5h" TYPICAL SECTION OF BEAMS TOP LEVEL DIFFERENCE
TYPICAL SECTION OF BEAMS TOP LEVEL DIFFERENCE
OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

REBAR (Fy=60000psi)

Nominal Size Actual Size


(Reduced 15% of Nominal Size)

Dia (mm) Area(in2) Dia (mm) Area(in2)

OWNER
6 mm 0.044 5.1 mm 0.0316
PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")

8 mm 0.078 6.8 mm 0.0562 BLOCK NO.


LOT NO.

10 mm 0.122 8.5 mm 0.0879 SUBJECT

GENERAL NOTE

12 mm 0.175 10.2 mm 0.1266 SCALE


3
16"=1'-0" SHEET NO.
GN-6
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)

16 mm 0.312 13.175 mm 0.211

18 mm 0.395 15.3 mm 0.2849

PE/RSE (CONSTRUCTION)
20 mm 0.487 17mm 0.3518

22 mm 0.589 18.7 mm 0.4257

25 mm 0.761 21.25 mm 0.5497 LC

NOTE
Reduced bar sizes can be acceptable if the reduced bar sizes
(actual bar size at the construction) is within nominal sizes.
OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"


6'-0"
F2 F2 F2 F2 F2
C2 C2 C1 C1 C2
A

6'-0"
OWNER

12'-0"
PROJECT THREE STOREYED R.C.C BUILDING
7'-0"
(40'-0" x 30'-0")

F2 F1 F2 BLOCK NO.
C2 C2 C2
B

7'-0"
LOT NO.
30'-0"

SUBJECT
12'-0"

FOUNDATION LAYOUT PLAN

1
SCALE 8"-1' SHEET NO.
F2 F2 F1 F1 F2 S-101
DATE SEPTEMBER,2022
C2 C2 C1 C1 C2
C PE/RSE (STRUCTURE)
6'-0"

F3 F3 F3 F3 F3
C3 C3 C3 C3 C3
D
4'-0"

4'-0"

PE/RSE (CONSTRUCTION)

FOUNDATION PLAN

ALLOWABLE SOIL BEARING CAPACITY, Qa = 0.8 Ton/sq-ft


LC
LEGEND

C1 - 14" x 14" R.C.C COLUMN (FROM FOUNDATION TO SECOND BEAM LEVEL)


C2 - 12" x 12" R.C.C COLUMN (FROM FOUNDATION TO SECOND BEAM LEVEL)
C3 - 9" x 9" R.C.C COLUMN (FROM FOUNDATION TO SECOND BEAM LEVEL)
F1 - 7'-0" x 7'-0" x 1'-0" R.C.C FOOTING (ISOLATED FOOTING)
F2 - 6'-0" x 6'-0" x 1'-0" R.C.C FOOTING (ISOLATED FOOTING) OWNER
F3 - 4'-0" x 4'-0" x 9" R.C.C FOOTING (ISOLATED FOOTING)
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"

C2 C2 C1 C1 C2
A
OWNER

12'-0"
PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")

BLOCK NO.
LOT NO.
C2 C2 C2
B SUBJECT
30'-0"

RETAINING WALL PLAN


12'-0"

RA RA
1
SCALE 8"-1' SHEET NO.
S-102
DATE SEPTEMBER,2022

C2 C2 C1 C1 C2 PE/RSE (STRUCTURE)

C
6'-0"

C3 C3 C3 C3 C3
D
PE/RSE (CONSTRUCTION)

RETAINING WALL PLAN

LEGEND
LC

C1 - 14" x 14" R.C.C COLUMN


C2 - 12" x 12" R.C.C COLUMN
C3 - 9" x 9" R.C.C COLUMN

- 9" THICK BRICK RETAINING WALL

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"

0'-6" 0'-6"

0'-6"
0'-7"

0'-6"

0'-6"

0'-6"
0'-6"
C2 C2 C1 C1 C2 OWNER
A
PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")
12'-0"
BLOCK NO.
LOT NO.

0'-6"

0'-6"
0'-6"
0'-6"

C2 C2 C2 SUBJECT

B FOUNDATION TO SECOND FLOOR


30'-0"

COLUMN LAYOUT PLAN

1
12'-0"

SCALE 8"-1' SHEET NO.


S-103
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
0'-6" 0'-6" 0'-7" 0'-6"

0'-6"
0'-6"
0'-6"

0'-6"

0'-6"
C2 C2 C1 C1 C2
C
6'-0"
0'-421"

C3 C3 C3 C3 C3
D PE/RSE (CONSTRUCTION)
0'-6"

FOUNDATION TO SECOND FLOOR COLUMN PLAN


LC
LEGEND

C1 - 14" x 14" R.C.C COLUMN (FROM FOUNDATION TO SECOND FLOOR)

C2 - 12" x 12" R.C.C COLUMN (FROM FOUNDATION TO SECOND FLOOR)

C3 - 9" x 9" R.C.C COLUMN (FROM FOUNDATION TO SECOND FLOOR) OWNER


MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"

0'-6"
0'-421" 0'-6"

0'-6"
0'-6"

0'-6"

0'-6"
0'-6"
C2 C2 C1 C1 C2
A OWNER

PROJECT THREE STOREYED R.C.C BUILDING


(40'-0" x 30'-0")

12'-0"
BLOCK NO.
LOT NO.
0'-421"

0'-421"
0'-6" 0'-6"
0'-421"

0'-5"
C2 C2 C2 SUBJECT
B SECOND TO ROOF FLOOR COLUMN
30'-0"

LAYOUT PLAN
12'-0"

1
SCALE 8"-1' SHEET NO.
S-104
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
0'-421" 0'-6"

0'-6"
0'-6"
0'-6"

0'-6"
0'-6"

C2 C2 C1 C1 C2
C
6'-0"

0'-421"

0'-421"
0'-421"

0'-6"
0'-421"

0'-6"
C3 C3 C3 C3 C3
D
PE/RSE (CONSTRUCTION)

SECOND TO ROOF FLOOR COLUMN PLAN


LC
LEGEND

C1 - 12" x 12" R.C.C COLUMN (FROM SECOND TO ROOF FLOOR)

C2 - 9" x 9" R.C.C COLUMN (FROM SECOND TO ROOF FLOOR)

C3 - 9" x 9" R.C.C COLUMN (FROM SECOND TO ROOF FLOOR)


OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"

C2 GB1 C2 GB1 C1 GB1 C1 GB1 C2


A OWNER

PROJECT THREE STOREYED R.C.C BUILDING


GB1

GB1
12'-0"

GB1
S.O.G (40'-0" x 30'-0")

BLOCK NO.
LOT NO.

C2 GB1 C2 C2
S.O.G
B S.O.G
SUBJECT
30'-0"

GROUND FLOOR PLAN


GB1
GB1

GB1

GB1
12'-0"

S.O.G SCALE
1
8"-1' SHEET NO.
S-105
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)

C2 GB1 C2 GB1 C1 GB1 C1 GB1 C2


C
GB1

GB1

GB1
6'-0"

S.O.G S.O.G
C3 C3 C3 C3 C3
D GB1 GB1 GB1 GB1
PE/RSE (CONSTRUCTION)

GROUND FLOOR PLAN (+2'- 0")

LEGEND LEGEND
LC

C1 - 14" x 14" R.C.C COLUMN


GB1 - 9" x 12" R.C.C GROUND BEAM
C2 - 12" x 12" R.C.C COLUMN
C3 - 9" x 9" R.C.C COLUMN
S.O.G - SLAB ON GROUND (ON COMPACTED LAYER)

LEVEL DROP 3" or Other Should be confirmed with Architectural Drawing.


OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"

C2 LB C2 C1 C1 C2
A OWNER

LS1

LB

LB
PROJECT THREE STOREYED R.C.C BUILDING
LB
12'-0"
(40'-0" x 30'-0")

BLOCK NO.
LOT NO.

C2 C2 C2
B SUBJECT
30'-0"

TYPICAL LANDING PLAN


12'-0"

1
SCALE 8"-1' SHEET NO.
S-106
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)

C2 C2 C1 C1 C2
C
6'-0"

C3 C3 C3 C3 C3
D
PE/RSE (CONSTRUCTION)

TYPICAL LANDING PLAN BETWEEN TYPICAL FLOOR LEVEL

LC
LEGEND

C1 - 14" x 14" R.C.C COLUMN (FROM FOUNDATION TO ROOF FLOOR)


C2 - 12" x 12" R.C.C COLUMN (FROM FOUNDATION TO ROOF FLOOR)
C3 - 9" x 9" R.C.C COLUMN (FROM FOUNDATION TO ROOF FLOOR)
LB - 9" x 12" R.C.C LANDING BEAM
OWNER
LS1 - 5" THICK LANDING SLAB
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"


SA

C2 FB2 C2 FB2 C1 FB2 C1 FB2 C2


A OWNER

FB2

FB2
PROJECT
S1 S1 S1 THREE STOREYED R.C.C BUILDING
12'-0"

FB2
(40'-0" x 30'-0")

BLOCK NO.

FB1

FB1
LOT NO.

C2 C2 FB2 FB2 FB2 C2


B SUBJECT
30'-0"

FB2 TYPICAL FLOOR PLAN

S1 S1 S1
FB2

FB2
12'-0"

FB2A
1
SCALE 8"-1' SHEET NO.
S1 S-107
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
C2 FB2 C2 FB2 C1 FB2 C1 FB2 C2
C
S1 S1 S1 S1
FB3

FB3

FB3

FB3

FB3
6'-0"

C3 C3 C3 C3 C3
D FB3 FB3 FB3 FB3
PE/RSE (CONSTRUCTION)
SA

TYPICAL FLOOR PLAN (+14'-0")

LEGEND LEGEND
LC
C1 - 14" x 14" R.C.C COLUMN FB1 - 12" x 20" R.C.C TYPICAL FLOOR BEAM
C2 - 12" x 12" R.C.C COLUMN FB2A - 9" x 15" R.C.C TYPICAL FLOOR BEAM
C3 - 9" x 9" R.C.C COLUMN FB2 - 9" x 12" R.C.C TYPICAL FLOOR BEAM
FB3 - 9" x 9" R.C.C TYPICAL FLOOR BEAM
LEVEL DROP 3" or Other Should be confirmed with Architectural Drawing.
S1 - 4" THICK R.C.C FLOOR SLAB(TWO WAY)

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"

RB2 RB2 RB2 RB2


A OWNER

RB2

RB2
12'-0" PC1 PC1 RB2 PROJECT THREE STOREYED R.C.C BUILDING

RB2
(40'-0" x 30'-0")
RB2
BLOCK NO.
LOT NO.

RB2 RB2
B SUBJECT

RB1
30'-0"

ROOF BEAM PLAN

PC1 PC1
RB2

RB2

RB2
12'-0"

1
SCALE 8"-1' SHEET NO.
RB2 RB2 S-108
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
RB2 RB2 RB2 RB2
C
RB2

RB2
6'-0"

RB2

RB2
D RB2 RB2 RB2 RB2
PE/RSE (CONSTRUCTION)

ROOF BEAM PLAN (+38'-0")

LEGEND
RB1 - 9" x 18" R.C.C ROOF BEAM
LC
RB2 - 9" x 9" R.C.C ROOF BEAM

NOTE

TOP OF THE COLUMN C3 ALONG GRID-D ARE DROP OFF 2'-2" OR OTHER SHOULD BE CONFIRMED WITH ARCHITECTURAL DRAWING.
ROOF BEAM ALONG (GRID D) AND SECTION X-X (BETWEEN GRID C & D ) ARE DROP OFF 2'-2" OR OTHER SHOULD BE CONFIRMED WITH ARCHITECTURAL DRAWING.

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"

JR JR JR JR
A R R
OWNER

JR JR
R
12'-0" R PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")

BLOCK NO.
R R LOT NO.

R Ridge Ridge R
B SUBJECT
R
30'-0"

TR1

TR1

TR1
R
JR JR RAFTER PLAN
12'-0"

R R SCALE
1
8"-1' SHEET NO.
S-109
JR JR DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
R
C R
JR JR JR JR
6'-0"

D
PE/RSE (CONSTRUCTION)

RAFTER PLAN

LEGEND
R (RAFTER) - 4" x 2" x 1.4 mm THICK HOLLOW SECTION LC

JR (JACK RAFTER) - 4" x 2" x 1.4 mm THICK HOLLOW SECTION

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 2 3 4 5
40'-0"

10'-0" 10'-0" 10'-0" 10'-0"

P
A P
OWNER

P PROJECT THREE STOREYED R.C.C BUILDING


(40'-0" x 30'-0")
12'-0"

P
BLOCK NO.

P LOT NO.

P P P P P P P SUBJECT
B P
30'-0"

PURLIN PLAN

P
12'-0"

1
SCALE 8"-1' SHEET NO.
S-110
P DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
P

P
C
P
6'-0"

P
D P PE/RSE (CONSTRUCTION)

PURLIN PLAN

LEGEND LC

P (PURLIN) - 3" x 1.5" x 1.2 mm THICK C-CHANNEL @ 2' - 6" C/C SPACING

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

FOUNDATION FOOTING SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ GN-007

Size BOTTOM REINFORCEMENT TOP REINFORCEMENT


Type REMARK
Parallel with Parallel with Parallel with Parallel with
L B H
Longer Direction Shorter Direction Longer Direction Shorter Direction

F1 7'-0" 7'-0" 1'-0" 16mmØ @ 6"c/c 16mmØ @ 6"c/c _ _ ISOLATED


FOOTING

F2 6'-0" 6'-0" 1'-0" 16mmØ @ 6"c/c 16mmØ @ 6"c/c _ _ ISOLATED


FOOTING

F3 4'-0" 4'-0" 0'-9" 16mmØ @ 6"c/c 16mmØ @ 6"c/c _ _ ISOLATED


FOOTING

# Foundation Depth is 4'-0" from N.G.L.


OWNER
# Allowable Bearing Capacity of soil Qa= 0.8 ton/sq.ft

PROJECT THREE STOREYED R.C.C BUILDING


(40'-0" x 30'-0")

BLOCK NO.
SLAB SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ GN-007
LOT NO.

Shorter Direction Longer Direction Distribution


Type Thickness Layer Remark
(in) Discont: Midspan Cont: Discont: Midspan Cont: Steel SUBJECT
FOOTING, SLAB & STAIR SCHEDULES
Top 10 d @ 12"c/c - 10 d @ 6"c/c 10 d @ 12"c/c - 10 d @ 6"c/c -
S1 4" Two way
Bottom 10 d @ 6"c/c 10 d @ 6"c/c 10 d @ 6"c/c 10 d @ 6"c/c 10 d @ 6"c/c 10 d @ 6"c/c -
SCALE SHEET NO.
S-201
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)

LANDING SLAB SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ GN-007

Short Direction Long Direction


Type Thickness Layer Remark
(in) Continous Midspan Discontinous Continous Midspan Discontinous

Top 12d @ 4" c/c 12d @ 4" c/c 12d @ 4" c/c
LS1 5'' 10d @ 8"c/c (Distribution Steel)
Bottom 12d @ 4" c/c 12d @ 4" c/c 12d @ 4" c/c
PE/RSE (CONSTRUCTION)

STAIR SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ GN-007

Steel Reinforcement LC
Waist
Layer Temperature & Clear Cover Remark
Stair No. Thickness Main Steel Shrinkage Steel ( in )
(in)
Continuous Mid Portion Discontinuous
Top 12d @ 4" c/c - 12d @ 4" c/c
Main Stair 5'' 10d @ 8" c/c 3
4
Bottom 12d @ 4" c/c 12d @ 4" c/c 12d @ 4" c/c

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

COLUMN SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ S-007

FOUNDATION TO GROUND FLOOR SECOND FLOOR TO ROOF FLOOR TO


COLUMN TYPE
GROUND FLOOR TO SECOND FLOOR ROOF BEAM ROOF TOP FLOOR

SIZE
&
DETAIL

C1 (12" x 12")
(14" x 14") (14" x 14")
MAIN STEEL 10-16mm Ø REBAR 10-16mm Ø REBAR 8-16mm Ø REBAR
2Loop-tie 2Loop-tie 1Loop+1cross-tie
TIES WITHIN Lo
6.5mm Ø @ 4" c/c 6.5mm Ø @ 4" c/c 6.5mm Ø @ 4" c/c
TIES BEYOND Lo 2Loop-tie 2Loop-tie 1Loop+1cross-tie
6.5mm Ø @ 6" c/c 6.5mm Ø @ 6" c/c 6.5mm Ø @ 6" c/c
OWNER

SIZE
&
PROJECT THREE STOREYED R.C.C BUILDING
DETAIL (9" x 9")
(12" x 12") (12" x 12") (40'-0" x 30'-0")

C2 MAIN STEEL 8-16mm Ø REBAR 8-16mm Ø REBAR


BLOCK NO.
4-16mm Ø REBAR
1Loop LOT NO.
1Loop+1cross-tie 1Loop+1cross-tie
TIES WITHIN Lo 6.5mm Ø @ 4" c/c
6.5mm Ø @ 4" c/c 6.5mm Ø @ 4" c/c
1Loop+1cross-tie 1Loop+1cross-tie 1Loop
TIES BEYOND Lo SUBJECT
6.5mm Ø @ 6" c/c 6.5mm Ø @ 6" c/c 6.5mm Ø @ 6" c/c
COLUMN SCHEDULES
SIZE
&
DETAIL (9" x 9") (9" x 9") (9" x 9")
SCALE SHEET NO.
C3 MAIN STEEL 4-16mm Ø REBAR 4-16mm Ø REBAR 4-16mm Ø REBAR S-202
DATE SEPTEMBER,2022
1Loop 1Loop 1Loop
TIES WITHIN Lo 6.5mm Ø @ 4" c/c 6.5mm Ø @ 4" c/c 6.5mm Ø @ 4" c/c PE/RSE (STRUCTURE)

TIES BEYOND Lo 1Loop 1Loop 1Loop


6.5mm Ø @ 6" c/c 6.5mm Ø @ 6" c/c 6.5mm Ø @ 6" c/c

SIZE
&
DETAIL

PC1 (9" x 9")


MAIN STEEL 4-16mm Ø REBAR
PE/RSE (CONSTRUCTION)
TIES WITHIN Lo 1Loop-6.5mm Ø @ 6" C/C

TIES BEYOND Lo 1Loop-6.5mm Ø @ 6" C/C

LC

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

GROUND FLOOR BEAM SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ GN-007

MAIN REINFORCEMENT SIDE BAR


TYPE STIRRUP
& END-SPAN (LEFT) MID-SPAN END-SPAN (RIGHT) OR
SIZE (in) TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2H OUTSIDE 2H

GB1- (9"x12") 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ - 1-6.5mmØ@4"c/c 1- 6.5mmØ@6"c/c

TYPICAL FLOOR BEAM SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ GN-007

MAIN REINFORCEMENT SIDE BAR


TYPE STIRRUP
& END-SPAN (LEFT) MID-SPAN END-SPAN (RIGHT) OR
SIZE (in) TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2H OUTSIDE 2H

FB1- (12"x20") 5-16mmØ 5-16mmØ 3-16mmØ 5-16mmØ 5-16mmØ 5-16mmØ 2-16mmØ 1-10mmØ@6"c/c 1- 10mmØ@6"c/c OWNER

FB2A- (9"x15") 3-16mmØ 3-16mmØ 2-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ - 1-6.5mmØ@4"c/c 1- 6.5mmØ@6"c/c
PROJECT THREE STOREYED R.C.C BUILDING
FB2- (9"x12") 3-16mmØ 3-16mmØ 2-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ - 1-6.5mmØ@4"c/c 1- 6.5mmØ@6"c/c (40'-0" x 30'-0")

FB3- (9"x9") 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ - 1-6.5mmØ@4"c/c 1- 6.5mmØ@6"c/c BLOCK NO.
LOT NO.

ROOF BEAM SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ GN-007
SUBJECT
MAIN REINFORCEMENT SIDE BAR
TYPE STIRRUP BEAM SCHEDULES
& END-SPAN (LEFT) MID-SPAN END-SPAN (RIGHT) OR
SIZE (in) TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2H OUTSIDE 2H

RB1- (9"x18") 3-16mmØ 3-16mmØ 2-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ - 1-6.5mmØ@4"c/c 1- 6.5mmØ@6"c/c SCALE SHEET NO.
S-203
DATE SEPTEMBER,2022
RB2- (9"x9") 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ - 1-6.5mmØ@4"c/c 1- 6.5mmØ@6"c/c
PE/RSE (STRUCTURE)

LANDING BEAM SCHEDULE FOR REBAR SIZE PLEASE SEE GENERAL NOTES @ S-007
MAIN REINFORCEMENT SIDE BAR
TYPE STIRRUP
& END-SPAN (LEFT) MID-SPAN END-SPAN (RIGHT) OR
SIZE (in) TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2H OUTSIDE 2H

LB- (9"x12") 3-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ - 1-6.5mmØ@4"c/c 1- 6.5mmØ@6"c/c
PE/RSE (CONSTRUCTION)

LC

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1
1

6'
X D

4'
X X X
OWNER

4' PROJECT THREE STOREYED R.C.C BUILDING


(40'-0" x 30'-0")
6' BLOCK NO.
LOT NO.
F3 (4'-0" x 4'-0" x 0'-9")
F2 (6'-0" x 6'-0" x 1'-0") GRID - D&1 SUBJECT
FOOTING DETAILS
GRID - A&1

SCALE 3/8"=1'-0" SHEET NO.


S-301
DATE SEPTEMBER,2022
1 1 PE/RSE (STRUCTURE)

GB1
GROUND FLOOR (+2'-0") GB1
GROUND FLOOR (+2'-0")
GB1
GB1
2'

1Loop+1cross-tie 6.5mm Ø @ 4" c/c

2'
1Loop 6.5mm Ø @ 4" c/c
PE/RSE (CONSTRUCTION)
N.G.L (0'-0") C2(12"x12")
N.G.L (0'-0") C3(9"x9")
1Loop+1cross-tie 6.5mm Ø @ 6" c/c

8 -16mmØ (Main) 1Loop 6.5mm Ø @ 6" c/c


4 -16mmØ (Main)
16d@6"c/c
4'

16d@6"c/c
4'

16d@6"c/c
16d@6"c/c
1'-0"

LC

0'-9"
3" thk: sand filling 3" thk: 1:3:6 Conc:
3" thk: sand filling 3" thk: 1:3:6 Conc:
6" thk: Hardcore
6" thk: Hardcore

F2
F3
SECTION X-X
SECTION X-X
OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

G.F.L(+2'-0")

GB1 (9x12)

1'
N.G.L
9" Thk;
Retaining Wall

1'
3" Thk; (1:3:6)

3"
Lean Concrete
6" Thk; Hard Core
1'-3"
OWNER

RETAINING WALL SECTION RA-RA


PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")
SCALE : 1/2"-1'-0"
BLOCK NO.
LOT NO.

SUBJECT
RETAINING WALL , GROUND BEAM &SLAB
DETAILS

SCALE AS SHOWN SHEET NO.


S-302
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)

A B C D
12' 12' 6'
PE/RSE (CONSTRUCTION)
T10@12"c/c T10@6"c/c T10@6"c/c T10@6"c/c T10@6"c/c T10@12"c/c

T10@6"c/c T10@6"c/c T10@6"c/c T10@6"c/c T10@6"c/c


FB2 T10@6"c/c S1 FB2 FB2 S1 FB3
S1 T10@6"c/c

SLAB SECTION-SA-SA
SCALE : 3/8"-1'-0" LC

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

3
FB1
SECOND FLOOR (+26'-0") C1(12"x12")

FB2 FB2

22"
10 -16mmØ (Main)
2Loops-tie 6.5mm Ø @ 4" c/c

2Loops-tie 6.5mm Ø @ 4" c/c


50% Lapping , Alternate

12'
14"
OWNER

14"
B B
PROJECT THREE STOREYED R.C.C BUILDING
Section B-B (40'-0" x 30'-0")

BLOCK NO.
2Loops-tie 6.5mm Ø @ 6" c/c LOT NO.

SUBJECT
10 -16mmØ (Main) COLUMN SECTION
22"

FB1
FIRST FLOOR (+14'-0")
SCALE 3/8"=1'-0" SHEET NO.
FB2 FB2 S-303
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
22"

10 -16mmØ (Main)
2Loops-tie 6.5mm Ø @ 4" c/c
C1(14"x14")

2Loops-tie 6.5mm Ø @ 4" c/c PE/RSE (CONSTRUCTION)


50% Lapping , Alternate
A A
12'

14"
14"

Section A-A

2Loops-tie 6.5mm Ø @ 6" c/c LC

10 -16mmØ (Main)
22"

GB1
GROUND FLOOR (+2'-0")

GB1 GB1 COLUMN C1 LONGITUDINAL SECTION @ GRID-A&3


2'

OWNER

N.G.L (0'-0")
C1(14"x14")
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

A B C D
12' 12' 6'

2'-0 "
3
16

2'-0 " 3
16

2'-0 " 3
16

2'-0 " 3
16

2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ


GB1 1 2 3 1 2 3 GB1 1A 2-16mmØ
GB1

1 2-16mmØ 2 2-16mmØ
3 1 2-16mmØ 2 2-16mmØ 3
1A 2-16mmØ OWNER

GB1(9"X12") GB1(9"X12")
C2 C2 C2 C3
GB1(9"X12") PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")

BLOCK NO.
9" 9" 9"
9"
LOT NO.
2 -16mmØ 2 -16mmØ 2 -16mmØ
2 -16mmØ

12"
1-6.5mm∅ @ 4" c/c
12"

12"
1-6.5mm∅ @ 4" c/c 1-6.5mm∅ @ 6" c/c

12"
1-6.5mm∅ @ 4" c/c 2 -16mmØ
2 -16mmØ 2 -16mmØ 2 -16mmØ
SUBJECT
BEAM SECTION
GB1- (9''X12") Section 1-1 GB1- (9''X12") Section 2-2 GB1- (9''X12") Section 3-3 GB1- (9''X12") Section 1A-1A
Scale - 34" = 1' Scale - 34" = 1' Scale - 43" = 1' Scale - 43" = 1'

GROUND BEAM SECTION @ GRID LINE - 5


SCALE 3/8"=1'-0" SHEET NO.
S-304
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)
A B C D
12' 12' 6'

3'-4" 3'-4"
3-16mmØ 3-16mmØ 3-16mmØ
2-16mmØ 2-16mmØ 2-16mmØ PE/RSE (CONSTRUCTION)
FB2 2-16mmØ FB2 2-16mmØ FB2
FB3

2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ


3-16mmØ 3-16mmØ 3-16mmØ
LC
C1 C1 C3
FB1(12"X20") FB1(12"X20") FB3(9"X9")

FLOOR BEAM SECTION @ GRID LINE - 4

12" 12" 12"

3 -16mmØ 5 -16mmØ
5 -16mmØ
OWNER
20"

20"

20"

2 -16mmØ 2 -16mmØ 2 -16mmØ 2 -16mmØ


1-10mm∅ @ 6" c/c 1-10mm∅ @ 6" c/c 1-6.5mm∅ @ 4" c/c
1-10mm∅ @ 6" c/c 2 -16mmØ
5 -16mmØ 5 -16mmØ 5 -16mmØ
FB3- (9''X9")
FB1- (12''X20") Edge FB1- (12''X20") Mid FB1- (12''X20") Edge
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

B A
12'-0"

1st Floor
OWNER

FB2
PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")

BLOCK NO.

12mm @ 4" C/C LOT NO.


10mm@8"C/C

12'-0"
L/3
SUBJECT
LS1 STAIR SECTION
LB LB
L/3

10mm @ 8" C/C 1/4"=1'-0"


SCALE SHEET NO.
for DIS; BAR S-305
L/3 DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)

Ground Floor
12mm @ 4" C/C
FOR MAIN BAR

GB1

PE/RSE (CONSTRUCTION)

STAIR SECTION
STAIR DIMENSION, RISE, RUN AND LEVEL SHOULD BE CONFIRMED WITH ARCHI OR CLIENT.

LC

OWNER
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

D C B A
6'-0" 12'-0" 12'-0"
PURLIN =C Channel - 3" x 1.5" x 1.2mm Thk;@ 2'-6" C/C

22°
Inclined Member = Hollow 100 x 50 x 1.4mm

PURLIN = C Channel- 3" x 1.5" x 1.2mm Thk;@ 2'-6" C/C Vertical Member = Hollow 100 x 50 x 1.4mm
TOP CHORD = Hollow 100 x 50 x 1.4mm

ROOF FLOOR LEVEL (+39'-0")

12"x2"x6mm PLATE 4' 4' 4' Detail-1


Detail-2 BOTTOM CHORD -
CORRIDOR TOP LEVEL (+36'-10") Fillet Weld
Hollow 100 x 50 x 1.4mm 3'-0"

3'-0" OWNER

C3(9"X9") C1(12"X12") C1(12"X12") PROJECT THREE STOREYED R.C.C BUILDING


TRUSS (T1) (40'-0" x 30'-0")

SCALE : 1/4"-1'-0" BLOCK NO.


NOTE** LOT NO.

TOP OF THE COLUMN C3 ALONG GRID-D ARE DROP OFF 2'-2" OR OTHER SHOULD BE CONFIRMED WITH
SUBJECT
ARCHITECTURAL DRAWING. TRUSS SECTION AND DETAIL
ROOF BEAM ALONG (GRID D) AND SECTION X-X (BETWEEN GRID C & D ) ARE DROP OFF 2'-2" OR OTHER SHOULD BE
CONFIRMED WITH ARCHITECTURAL DRAWING.

SCALE 1/4"=1'-0" SHEET NO.


TOP CHORD = Hollow 100 x 50 S-306
DATE SEPTEMBER,2022
Vertical Member - Hollow 100 x 50 PURLIN = C Channel - 3" x 1.5" x 1.2mm PE/RSE (STRUCTURE)
@2'-6" C/C

Steel Prop
Inclined Member - Hollow 100 x 50
Bottom Chord - Hollow 100 x 50

4- 21"ØBolts
Plate size & Thickness = 8"x 6"x10mm
1 Embedded Length for bolt = 6"
16"
PE/RSE (CONSTRUCTION)

Detail -2
Detail -1 (Elevation View)
Scale : 12"-1'-0" Scale : 12"-1'-0"

LC
8"
1"

1 1
12" 12"
6"

4- 21"Ø Anchor Bolt


(Embedded Length - 6")
1
1"

16"

OWNER
Detail -2
(Plan View)
Scale : 3 4"-1'-0"
MATERIAL STRENGTH - f'c = 2500 p.s.i, fy = 60000 p.s.i, fys = 40000 p.s.i

1 A 2 B

RAFTER = HOLLOW - 4" x 2" x 1.4mm

12"x2"x6mm Plate

FILLET WELD
PURLIN = C Channel- 3" x 1.5" x 1.2mm Thk;@ 2'-6" C/C

OWNER

ROOF FLOOR LEVEL (+39'-0") PC1 PROJECT THREE STOREYED R.C.C BUILDING
(40'-0" x 30'-0")

BLOCK NO.
LOT NO.

C1(12"X12") SUBJECT
ROOF SECTION
ROOF SECTION
SCALE : 1/4"-1'-0"
SCALE 1/4"=1'-0" SHEET NO.
S-307
DATE SEPTEMBER,2022
PE/RSE (STRUCTURE)

PE/RSE (CONSTRUCTION)

LC

OWNER