Turnover Punchlist Guidelines

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

PROJECT: DATE:

SUBJECT: TURNOVER MEETING -1

ITEM # ITEM DESCRIPTION POINTERS


1 EXTERIORE/FAÇADE
CHECK ALIGNMENT AND FUNCTIONALITY. CHECK LOCATION OF LED DRIVE OF SIGNAGE- IT SHOULD BE
SIGNAGE/LIGHTING ACCESSIBLE. IF HIDDEN ABOVE THE CEILING, IT SHOULD HAVE A HANDHOLE UNDERNEATH FOR
SERVICEABILITY. IF LED DRIVE IS EXPOSED, WEATHER PROOF LED DRIVE SHOULD BE USED.

CHECK ALIGNMENT. CHECK STABILITY-RECO IF FINS ARE NEEDED. CHECK GLASS DOOR CLEARANCE. SHOULD BE
GLASS PANEL/GLASS DOOR MINIMAL TO PREVENT ENTRY OF PEST. CHECK GLASS DOOR FUNCTIONALY. DOOR SHOULD SWING
SMOOTHLY.

PAINTING CHECK FOR EVENESS OF PAINT FINISH


ROLL UP DOOR CHECK FOR FUNCTIONALITY & ACCESS (HANDHOLE)
EXIT SIGN SHOULD BE PROVIDED ON ALL EXIT DOORS
2 DINING AREA
CHECK FOR FUNCTIONALITY. CHECK FOR SERVICEABILITY-IF IT IS A CEILING CASSETTE TYPE (FOR STORES WITH
CEILING BOARD) IT SHOULD HAVE A MANHOLE BESIDE THE INDOOR UNIT. IF NOT POSSIBLE PROVIDE
CATWALK ACCESS FROM THE NEAREST MANHOLE. (MANHOLE SHOULD BE TESTED FOR STURDINESS). CHECK
AIRCON ACCESS OF OUTDOOR UNIT-DISTANCE FROM INDOOR TO OUTDOOR UNIT SHOULD BE WITHIN ALLOWABLE
STANDARD OF MANUFACTURER. DRAIN LINES SHOULD NOT BE TAPPED TO ANY WASTE AND SOIL PIPE; INCASE
OF 1 DRAIN LINE FOR ALL UNITS, DRAIN PIPE SIZE SHOULD BE 2". SHOULD HAVE PROPER TAGGING,
CONSISTENT WITH OUTDOOR AND PANEL BOARD TAGGING
AIR CURTAIN CHECK FOR STABILITY. RECO IF ADDITIONAL SUPPORT IS NEEDED
CHECKTILE GROUT, TILE ALIGNMENT AND LEVELNESS AND CHECK FOR HOLLOW TILES. USE 1/2" PVC PIPE TO
FLOOR FINISH
KNOCK TILES TO CHECK FOR HOLLOW TILES
FOR SMOOTH PAINT FINISH CHECK FOR PAINT EVENESS. FOR WALL BRICKS AND RECLAIMED WOOD FINISH
WALL FINISH
FILL HOLES AND GAPS WITH FILLERS TO PREVENT INSECT INFESTATION
CHECK FOR LEVELNESS AND PAINT EVENESS. CHECK FOR GAPS AND HOLES THAT MAY SERVE AS AN ACCESS
CEILING FINISH
FOR PEST
CHECK FOR STABILITY OF CHAIR, TABLES AND SHELVES. DO THE WIGGLE TEST. HIGH SHELVES SHOULD BE
FURNITURES
ANCHORED TO WALL, FLOORING OR CEILING
FLOOR OUTLETS CHECK FOR STABILITY AND FUNCTIONALITY.
CHECK FOR FUNCTIONALITY. CHECK IF THERE ARE LIGHTS ARE LYING TO LOW THAT MAY HINDER
LIGHTING CUSTOMERS. CHECK FOR EXPOSED WIRING. FOR VISUAL LIGHTING, LED DRIVE SHOULD BE ACCESSIBLE FOR
SERVICEABILITY
FOR OPEN CEILING . UTILITIES SHOULD BE PROPERLY PAINTED. UTILITIES PIPES AND DUCTS SHOULD BE
OVERHEAD FACILITY
TAGGED FOR EASY IDENTIFICATION
INSECT KILLER SHOULD BE STATEGICALLY DISTRIBUTED THROUGHOUT THE AREA
FIRE EXIT SIGNAGES SHOULD BE LIGHTED, VISIBLE AND PLACED ON ALL EXIT DOORS.
EMERGENCY LIGHTS SHOULD PROVIDE AMPLE LIGHT ON THE ROUTE FROM ANYWHERE THE STORE TO THE EXIT

FOR CLOSED CEILING, SPRINKLER HEAD SHOULD BE FULLY EXPOSED. CHECK FOR MISSING ESCUTCHEON.
SPRINKLER
SENSITIVE GLASS BULB TRIGGER SHOULD HAVE NO PAINT

CHECK FOR LOCATION. SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE STORE. CHECK IF PLASTIC COVER
SMOKE DETECTOR
IS ALREADY DETACHED

FIRE EXTINGUISHER AT LEAST PROVIDE ONE DRY CHEMICAL (RED) BEFORE BFP INSPECTION. SHOULD BE WALL MOUNTED
3 TOILET
CHECKTILE GROUT, TILE ALIGNMENT AND LEVELNESS AND CHECK FOR HOLLOW TILES. USE 1/2" PVC PIPE TO
FLOOR FINISH
KNOCK TILES TO CHECK FOR HOLLOW ONCE
FOR SMOOTH PAINT FINISH CHECK FOR PAINT EVENESS. FOR WALL BRICKS AND RECLAIMED WOOD FINISH
WALL FINISH
FILL HOLES AND GAPS WITH FILLERS TO PREVENT INSECT INFESTATION
CHECK FOR LEVELNESS AND PAINT EVENESS. CHECK FOR GAPS AND HOLES THAT MAY SERVE AS AN ACCESS
CEILING FINISH
FOR PEST
CHECK SEALANT, LEVELNESS AND STABILITY OF INSTALLATION. SHOULD HAVE NO CEMENT MARKS OR ANY
MIRROR
CRACKS.
GRAB BARS CHECK LEVELNESS AND STABILITY OF INSTALLATION
CHECK FUNCTIONALITY. CHECK SEALANT, LEVELESS AND STABILITY OF INSTALLATION. SHOULD HAVE ANGLE
LAVATORY & FAUCET
VALVE & SHOULD BE ACCESSIBLE.
CHECK FUNCTIONALITY. CHECK SEALANT, LEVELESS AND STABILITY OF INSTALLATION. SHOULD HAVE ANGLE
URINAL
VALVE & SHOULD BE ACCESSIBLE.
CHECK FUNCTIONALITY. CHECK SEALANT, LEVELESS AND STABILITY OF INSTALLATION. SHOULD HAVE ANGLE
WATER CLOSET
VALVE & SHOULD BE ACCESSIBLE.
SOAP DISPENSER CHECK FUNCTIONALITY. CHECK LEVELESS AND STABILITY OF INSTALLATION.
TISSUE DISPENSER CHECK FUNCTIONALITY. CHECK LEVELESS AND STABILITY OF INSTALLATION.
HAND DRYER CHECK FUNCTIONALITY. CHECK LEVELESS AND STABILITY OF INSTALLATION.
CHECK FUNCTIONALITY. CHECK LEVELESS AND STABILITY OF INSTALLATION. SHOULD HAVE GFCI OUTLET
AIR SCENT
PROVISION
OUTLET ALL OUTLETS SHOULD BE GFCI
EXHAUST FAN CHECK FUNCTIONALITY. CHECK LEVELESS AND STABILITY OF INSTALLATION.
CLEAN OUT SHOULD HAVE NO OBSTRUCTION FOR SERVICEABILITY
LIGHTING CHECK FUNCTIONALITY
CHECK ALIGNMENT, STABILITY AND DOOR CLEARANCE. CLEARANCE SHOULD BE MINIMAL TO PREVENT ENTRY
DOOR
OF PEST. DOOR SHOULD SWING SMOOTHLY.
CHECK FOR LOCATION. SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE STORE. CHECK IF PLASTIC COVER
SMOKE DETECTOR
IS ALREADY DETACHED
FOR CLOSED CEILING, SPRINKLER HEAD SHOULD BE FULLY EXPOSED. CHECK FOR MISSING ESCUTCHEON.
SPRINKLER
SENSITIVE GLASS BULB TRIGGER SHOULD HAVE NO PAINT
FIRE EXTINGUISHER AT LEAST PROVIDE ONE DRY CHEMICAL (RED) BEFORE BFP INSPECTION. SHOULD BE WALL MOUNTED
4 BAR
CHECKTILE GROUT, TILE ALIGNMENT AND LEVELNESS AND CHECK FOR HOLLOW TILES. USE 1/2" PVC PIPE TO
FLOOR FINISH
KNOCK TILES TO CHECK FOR HOLLOW ONCE
FOR SMOOTH PAINT FINISH CHECK FOR PAINT EVENESS. FOR WALL BRICKS AND RECLAIMED WOOD FINISH
WALL FINISH
FILL HOLES AND GAPS WITH FILLERS TO PREVENT INSECT INFESTATION
CHECK FOR LEVELNESS AND PAINT EVENESS. CHECK FOR GAPS AND HOLES THAT MAY SERVE AS ACCESS OF
CEILING FINISH
PEST
BAR COUNTER FINISH CHECK FOR FUNCTIONALITY, STABILITY VISIBLE CRACKS AND AESTHETIC CONDITION
CARPENTRY CHECK FOR CABINET AND CABINET DOOR STABILITY AND ALIGNMENT
CHECK FOR FUNCTIONALITY. CHECK PROVISION FOR WATER, ELECTRIC AND DRAIN. SHOULD BE PROPERLY
EQUIPMENTS
GROUNDED.
SHOULD BE ALL GFCI. PROVIDE SEPARATE BREAKER FOR ESPRESSO MACHINE & MERRYCHEF OVEN. PROVIDE
EQUIPMENT OUTLETS
AVR FOR ESPRESSO MACHINE & REF UNITS ESPECIALLY PASTRY CHILLER
CHECK FOR FUNCTIONALITY. CONDUCT SIMPLE FLOW TEST BY DRAINING A BUCKET OF WATER
FLOOR DRAIN
CONTINUOUSLY. CHECK FOR OPEN DRAIN
CHECK FOR FUNCTIONALY AND SERVICEABILITY. REPLACING OF WATER FILTER SHOULD BE POSSIBLE WITHOUT
WATER FILTRATION DISASSEMBLING THE WATER FILTRATION PIPE SYSTEM. SHOULD HAVE BYPASS AND WITH PROPER TAGGING.
SHOULD HAVE GFCI OUTLET PROVISION
WATER METER SHOULD BE CALIBRATED AND CAN BE EASILY ACCESSED FOR READABILITY; WITH PRESSURE
WATERLINE GAUGE. GATE VALVE FUNCTIONALITY AND ACCESSIBILITY. SEPARATE GATE VALVE FOR BAR, KITCHEN AND
TOILET. ALL FIXTURES SHOULD HAVE ANGLE VALVE
KITCHEN SINK CHECK FUNCTIONALITY. CHECK SEALANT, LEVELESS AND STABILITY OF FAUCET INSTALLATION
SERVICEABILITY OF GREASE TRAP. COVER CAN BE EASILY REMOVED FOR CLEANING. SHOULD HAVE A
GREASE TRAP
CLEANOUT
CLEAN OUT SHOULD HAVE NO OBSTRUCTION FOR SERVICEABILITY
CHECK FOR FUNCTIONALITY. CHECK IF THERE ARE LIGHTS ARE LYING TO LOW THAT MAY HINDER
LIGHTING CUSTOMERS. CHECK FOR EXPOSED WIRING. FOR VISUAL LIGHTING, LED DRIVE SHOULD BE ACCESSIBLE FOR
SERVICEABILITY
CHECK FUNCTIONALITY, AND STABILITY OF INSTALLATION. OUTLETS NEAR WATER SOURCE (SINK, ETC.)
OUTLET
SHOULD BE GFCI.
INSECT KILLER CHECK FOR FUNCTIONALITY. SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE AREA
CABINET CHECK FOR FUNCTIONALITY & STABILITY OF INSTALLATION. CHECK HINGES.
CHECK FOR LOCATION. SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE STORE. CHECK IF PLASTIC COVER
SMOKE DETECTOR
IS ALREADY DETACHED
FOR CLOSED CEILING, SPRINKLER HEAD SHOULD BE FULLY EXPOSED. CHECK FOR MISSING ESCUTCHEON.
SPRINKLER
SENSITIVE GLASS BULB TRIGGER SHOULD HAVE NO PAINT
EMERGENCY LIGHTS SHOULD PROVIDE AMPLE LIGHT ON THE ROUTE FROM ANYWHERE THE STORE TO THE EXIT
FIRE EXTINGUISHER AT LEAST PROVIDE ONE HCFC (GREEN) BEFORE BFP INSPECTION. SHOULD BE WALL MOUNTED
5 KITCHEN
CHECKTILE GROUT, TILE ALIGNMENT AND LEVELNESS AND CHECK FOR HOLLOW TILES. USE 1/2" PVC PIPE TO
FLOOR FINISH
KNOCK TILES TO CHECK FOR HOLLOW ONCE
FOR SMOOTH PAINT FINISH CHECK FOR PAINT EVENESS. FOR WALL BRICKS AND RECLAIMED WOOD FINISH
WALL FINISH
FILL HOLES AND GAPS WITH FILLERS TO PREVENT INSECT INFESTATION
CHECK FOR LEVELNESS AND PAINT EVENESS. CHECK FOR GAPS AND HOLES THAT MAY SERVE AS ACCESS
CEILING FINISH
FORPEST (SPECIALLY ABOVE SLOP SINK AREA)
CHECK FOR FUNCTIONALITY. CHECK PROVISION FOR WATER, ELECTRIC AND DRAIN. SHOULD BE PROPERLY
EQUIPMENTS
GROUNDED.
SHOULD BE ALL GFCI. PROVIDE AVR FOR REFRIGERATION- DUE TO VOLTAGE FLUCTUATION. PROVIDE
EQUIPMENT OUTLETS
SEPARATE BREAKER FOR INDUCTION STOVE.
CHECK FOR FUNCTIONALITY. CHECK IF THERE ARE LIGHTS ARE LYING TO LOW THAT MAY HINDER
LIGHTING CUSTOMERS. CHECK FOR EXPOSED WIRING. FOR VISUAL LIGHTING, LED DRIVE SHOULD BE ACCESSIBLE FOR
SERVICEABILITY
CHECK FOR FUNCTIONALITY. CONDUCT SIMPLE FLOW TEST BY DRAINING A BUCKET OF WATER
FLOOR DRAIN
CONTINUOUSLY. EACH DRAIN MUST HAVE A COVER. CHECK FOR OPEN DRAIN
CLEAN OUT SHOULD HAVE NO OBSTRUCTION FOR SERVICEABILITY
CHECK ALIGNMENT, STABILITY AND DOOR CLEARANCE. CLEARANCE SHOULD BE MINIMAL TO PREVENT ENTRY
DOOR
OF PEST. DOOR SHOULD SWING SMOOTHLY.
CHECK FOR FUNCTIONALY AND SERVICEABILITY. REPLACING OF WATER FILTER SHOULD BE POSSIBLE WITHOUT
WATER FILTRATION DISASSEMBLING THE WATER FILTRATION PIPE SYSTEM. SHOULD HAVE BYPASS AND WITH PROPER TAGGING.
SHOULD HAVE GFCI OUTLET PROVISION
KITCHEN SINK CHECK FUNCTIONALITY. CHECK SEALANT, LEVELESS AND STABILITY OF FAUCET INSTALLATION
SERVICEABILITY OF GREASE TRAP. COVER CAN BE EASILY REMOVED FOR CLEANING. SHOULD HAVE A
GREASE TRAP
CLEANOUT
CONDUCT SIMPLE FLOW TEST ON FLOOR DRAIN. DRAIN 1 BUCKET OF WATER CONTIUOUSLY. CONDUCT
SLOP SINK SIMPLE FLOOD TEST ON SLOP SINK. CLOG THE DRAIN WITH A CLOTH AND FILL WITH WATER (TO TEST THE
WATER TIGHTNESS OF SLOP SINK)
WATER METER SHOULD BE CALIBRATED AND CAN BE EASILY ACCESSED FOR READABILITY; WITH PRESSURE
GAUGE GATE VALVE FUNCTIONALITY AND ACCESSIBILITY. SEPARATE GATE VALVE FOR BAR, KITCHEN AND
WATERLINE TOILET. ALL FIXTURES SHOULD HAVE ANGLE VALVE. CAN CONDUCT BASIC LEAK TEST BY CLOSING ALL ANGLE
VALVE FOR EQUIPMENTS WATER SUPPLY AND NOTE THE READING. READING SHOULD BE THE SAME THE DAY
AFTER BEFORE OPERATIONS
WATER HEATER CHECK FOR SERVICEABILITY AND ACCESSIBILITY SHOULD HAVE SEPARATE BREAKER.
INSECT KILLER CHECK FOR FUNCTIONALITY. SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE AREA
CABINET CHECK FOR FUNCTIONALITY & STABILITY OF INSTALLATION. CHECK HINGES.
CHECK FOR FUNCTIONALITY AND SERVICEABILITY. SHOULD HAVE SEPARATE MAGNETIC CONTACTOR. CHECK IF
THERE IS HANDHOLE ON EXHAUST DUCT. PROVIDE CATWALK IF NEEDED. SHOULD PROVIDE HANDHOLE EVERY
VENTILATION
5 METERS BEFORE BLOWER. HANDHOLE SIZE 12"X12". BAFFLE FILTERS, LIGHTS, AND OIL CATCHER SHOULD BE
COMPLETE.
EMERGENCY LIGHTS SHOULD PROVIDE AMPLE LIGHT ON THE ROUTE FROM ANYWHERE THE STORE TO THE EXIT
FOR CLOSED CEILING, SPRINKLER HEAD SHOULD BE FULLY EXPOSED. CHECK FOR MISSING ESCUTCHEON.
SPRINKLER
SENSITIVE GLASS BULB TRIGGER SHOULD HAVE NO PAINT
CHECK FOR LOCATION. SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE STORE. CHECK IF PLASTIC COVER
HEAT DETECTOR
IS ALREADY DETACHED
FIRE SUPPRESSION CHECK FOR FUNCTIONALITY
FIRE EXTINGUISHER AT LEAST PROVIDE ONE CLASS K (SILVER) BEFORE BFP INSPECTION. SHOULD BE WALL MOUNTED
6 OFFICE
COMPUTER DESKTOP SET CHECK FOR FUNCTIONALITY
MONITOR FOR CCTV CHECK FOR FUNCTIONALITY. CHECK FOR CCTV BLINDSPOTS
CHECK FOR LOCATION. SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE STORE. CHECK IF PLASTIC COVER
SMOKE DETECTOR
IS ALREADY DETACHED
FIRE EXTINGUISHER AT LEAST PROVIDE ONE HCFC (GREEN) BEFORE BFP INSPECTION. SHOUL BE WALL MOUNTED
CHECKTILE GROUT, TILE ALIGNMENT AND LEVELNESS AND CHECK FOR HOLLOW TILES. USE 1/2" PVC PIPE TO
FLOOR FINISH
KNOCK TILES TO CHECK FOR HOLLOW TILES
FOR SMOOTH PAINT FINISH CHECK FOR PAINT EVENESS. FOR WALL BRICKS AND RECLAIMED WOOD FINISH
WALL FINISH
FILL HOLES AND GAPS WITH FILLERS TO PREVENT INSECT INFESTATION
CHECK FOR LEVELNESS AND PAINT EVENESS. CHECK FOR GAPS AND HOLES THAT MAY SERVE AS AN ACCESS
CEILING FINISH
FOR PEST
6 EE ROOM
SHOULD BE PROPERLY TAGGED. SHOULD BE COMPREHENSIBLE BY A NON TECHNICAL PERSON. WITHOUT
MDP
OBSTRUCTION AND CAN BE EASILY OPENED
SHOULD BE PROPERLY TAGGED. SHOULD BE COMPREHENSIBLE BY A NON TECHNICAL PERSON. WITHOUT
PANEL BOARD
OBSTRUCTION AND CAN BE EASILY OPENED
FIRE EXTINGUISHER AT LEAST PROVIDE ONE HCFC (GREEN) BEFORE BFP INSPECTION. SHOULD BE WALL MOUNTED
CHECKTILE GROUT, TILE ALIGNMENT AND LEVELNESS AND CHECK FOR HOLLOW TILES. USE 1/2" PVC PIPE TO
FLOOR FINISH
KNOCK TILES TO CHECK FOR HOLLOW TILES
FOR SMOOTH PAINT FINISH CHECK FOR PAINT EVENESS. FOR WALL BRICKS AND RECLAIMED WOOD FINISH
WALL FINISH
FILL HOLES AND GAPS WITH FILLERS TO PREVENT INSECT INFESTATION
CHECK FOR LEVELNESS AND PAINT EVENESS. CHECK FOR GAPS AND HOLES THAT MAY SERVE AS AN ACCESS
CEILING FINISH
FOR PEST
7 STORAGE ROOM
STORAGE RACKS CHECK FOR STABILITY OF RACKS
FIRE EXTINGUISHER AT LEAST PROVIDE ONE DRY CHEMICAL (RED) BEFORE BFP INSPECTION. SHOULD BE WALL MOUNTED
CHECKTILE GROUT, TILE ALIGNMENT AND LEVELNESS AND CHECK FOR HOLLOW TILES. USE 1/2" PVC PIPE TO
FLOOR FINISH
KNOCK TILES TO CHECK FOR HOLLOW TILES
FOR SMOOTH PAINT FINISH CHECK FOR PAINT EVENESS. FOR WALL BRICKS AND RECLAIMED WOOD FINISH
WALL FINISH
FILL HOLES AND GAPS WITH FILLERS TO PREVENT INSECT INFESTATION
CHECK FOR LEVELNESS AND PAINT EVENESS. CHECK FOR GAPS AND HOLES THAT MAY SERVE AS AN ACCESS
CEILING FINISH
FOR PEST

PREPARED BY:

NOTED BY:

CONFORME:

You might also like