SERIES S high-speed AC/DC Hybrid deep well

pump

CONTENTS

1. Description.....................................................................................................3

2. Pump structure............................................................................................. 7

3. Assembly and Commissioning...................................................................8

4. Pump Models.............................................................................................. 27

5. Pump Start and stop..................................................................................28

6. Troubles shooting guide........................................................................... 28

7. Completeness and guarantee conditions.............................................. 29

2
1. Description

1.1.SERIES S high speed AC/DC Hybrid pump introduction SERIES S high


speed AC/DC Hybrid pump is the newest vertical pump independently developed
by TAIFU, which is configured with multiple stainless steel (centrifugal or mixed
flow) impellers and pump bowl, propeller shaft, coupling, permanent
magnetism synchronous motor and other specially customized components. The
motor is located at bottom and drives the impellers to rotate by the coupling, then
generates flow and head.

The products are widely used as pumping and drainage equipment in many fields,
such as power plants, steel plants, mining, chemical, fire-fighting, water plants,
agricultural irrigation, etc.

Also widely applicable to long-distance water delivery and irrigation, high-efficiency


aeration in aquaculture, deep well water extraction, urban and rural tap water
pressurization, mine water supply and drainage, and food and chemical industries
to transport non-corrosive chemical liquids.

1.2.Specification:

Max.Flow Q:3~100m3/h

Max.Head H:800m(max)

Power P:1.5~11kW

Rotation Speed N:4800-5200 r/min

Operating voltage:320VAC~450VAC(Nominal voltage 380V AC)

480VDC~520VDC(Nominal voltage 500VDC)

Model Instruction eg:4GS6/11-4W

4:Diameter of pump

GS: High speed deep well pump

6: Rated flow (m3/h)

/11:Impeller stages
3
4:Motor power (KW)

W: External controller 。(N - built-in controller)

1.3.Fluid requirements

Liquid temperature < +40℃.

The solid impurities (by weight) < 0.01%.

The pH value 6.5~8.5.

The hydrogen sulfide content is not more than 1.5mg/l, and doesn’t contain any oil.
(When used in deep wells, the pump body should be kept vertical and two-way
bending is not allowed.)

1.4.Safety

Before installation, please read this manual carefully, pay attention to the safety
warning signs and instructions in the manual. The factory does not bear any
responsibility or compensation for any personal injury, water pump damage and
other property losses caused by failing to observe the safty warnings.

Those who is professional or trained could use and install the pump.

When carrying out any mechanical or electrical installation and maintenance of this
product, the lifting and maintenance equipment must be safe and reliable.

Before or after installing and using this product, the equipment foundation and
working environment must be safe and reliable.

Before performing any mechanical or electrical installation and maintenance of this


product, the power supply of the motor must be cut off. Pump must be stopped
during maintenance.

During maintenance, if the power supply is not be cut off, the water pump may start
suddenly and cause serious injury, electric shock, burns, or fatal accident.

4
1.5.Selection of pump model

Be attention to that correct selection can prolong the service life of pumps, motors,
and wells.

1.5.1 The pump diameter means that the pump can be placed in a deep well 1inch
larger than the pump diameter. When the well depth exceeds 30m or the well
pipe is cast iron or cement pipe, the actual well diameter should be 2inch
larger than the pump diameter.

1.5.2 The flow rate of the pump cannot be larger than the normal water flow of the
well. If the flow rate of the pump ≥ the normal water flow of the well, it may
cause collapse in the well.

1.5.3 Head calculation:H=(H1+H2+△h)×1.1

In formula:

H-head(m)

H1-The distance from the water level in the well to the outlet of the well(m)

H2-The vertical height from the center of the wellhead outlet to the ground where
the flow reaches(m)

△h-The resistance loss in the lifting pipe and the resistance loss after passing
pump outlet(m)

5
(Table1-1)

(Pipeline losses of head are shown as the table1-1

Flow rate (m³/h)


Pipe
diameter 1.8 3.6 7.2 14.4 21.6 28.8 36 54 72
(mm)

Head loss per hundred meters


25 7.7 31 125
(m)
38 0.7 2.9 11.5 46
50 0.8 3.3 13 29
65 0.8 3.2 7.3 13 20.
75 0.4 1.5 3.5 6.2 9.6 21.5
100 0.3 0.8 1.4 2.2 4.8 8.5

The numbers in the table refer to the new cast iron pipe as the standard. If it is the
old pipe, the resistance will increase, the plastic pipe is 0.7 times of the steel pipe,
the rubber pipe is the same as the steel pipe, and the steel pipe is 0.7 times of the
new cast iron pipe.

6
1.6.Cable selection recommendation

Table 1-2 (L is the total length of cable)

≤2.2kW 3kW 4kW 5.5kW 7.5kW 11kW

Motor model 380V 380V 380V 380V 380V 380V

L<20m /500DC
1.5mm² /500DC
1.5mm² /500DC
2.0mm² /500DC
2.0mm² /500DC
2.5mm² /500DC
3.0mm²

20m<L<50m 1.5mm² 2.0mm² 2.5mm² 2.5mm² 3.0mm² 3.5mm²

50m<L<100m 2.0mm² 2.5mm² 3.0mm² 3.0mm² 3.5mm² 4.0mm²

100m<L<200m 2.5mm² 3.0mm² 3.5mm² 4.0mm² 4.0mm² 6.0mm²

1.7.Estimated value of cable loss

Table 1-3 (Loss value at recommended cable specifications. Cable loss is ignored if
the cable length is less than 20m(380V/500VDC). L is the total length of cable.)

Motor ≤2.2kW 3kW 4kW 5.5kW 7.5kW 11kW


model

L=50m 0.1kw 0.1w 0.1kw 0.2kw 0.3kw 0.4kw

L=100m 0.1kw 0.2kw 0.2kw 0.5kw 0.5kw 0.6kw

L=200m 0.2kw 0.2kw 0.3kw 0.8kw 0.8kw 0.8kw

2. Pump structure

2.1 Pump structure

This product is composed of three parts: motor, controller (Built-in models integrate
the motor with the controller) and the pump body.

2.1.1 Motor

The motor is composed of motor body, stator, rotor, lower bearing seat, oil chamber,
mechanical seal and etc. Using the high-speed and high-pressure mechanical seal.

7
The stator and rotor cores are laminated with high-performance and low-loss silicon
steel sheets. The enameled winding wire is class-H military corona-resistant round
enameled round copper wire. The rotating shaft is made of corrosion-resistant,
high-strength, and wear-resistant materials.

2.1.2 Controller

The external controller part is composed of control board, drive board, fan,
heat-dissipating aluminum block, shell, and etc., with intelligent control functions,
which is high efficiency and energy saving. The built-in controller is a chip structure
that is integrally poured with epoxy.

2.1.3 Pump body

This part is composed of centrifugal or mixed flow impellers, guide vane, volute,
pump shaft, coupling, etc. Special wear-resistant and high-temperature resistant
rubber bearings, shaft sleeve. Stainless steel pump bodies or plastic impellers are
optional, etc.

3.Assembly and Commissioning ( Suitable for external controller)

3.1Preparation before Assembly

3.1.1 Open the outer packing box, take out the packing list, check whether the items
in the list are complete, and proceed to the next step after confirmation.

3.1.2 Preparation of tools and equipment: In addition to the tools configured with
this product, the following tools and equipment need to be prepared.

A. Refer to 1.6 to select two suitable 3-core cables with ground wire (one for inverter
output and one for input);

B.A suitable pipe wrench for this pump;

C.A set of open-end wrench;

D.Wire plier, scissor, cross screwdriver.

3.1.3 Check and clean up the parts of the pump set. Use oil to clean all mating
surfaces (threads, spigots, end faces, etc.) of the parts to be installed. Rubber
bearings must keep away from any oil to avoid deformation. Check whether the
mating surfaces of all parts have bumps, scratches, oil stains, etc. If so, they should
be carefully trimmed and oiled to prevent rust.

8
Do not disassemble or reassemble the working parts that have been assembled in
the factory. But check whether the transmission part of the working part rotates
evenly and flexibly.

3.2 Assembly sequence(Except the water pump that has been integrally
installed)

3.2.1 Open the packing box, connect the coupling of the pump body and the spline
shaft of the motor, and fasten it with the nuts and spring washers from the spare
parts package.

3.2.2 Use the heat shrinkable tube in the spare parts package to connect the
prepared cable with the motor cable, put three heat shrinkable tube of suitable
length on the three wires, strip the wire ends, and cover the copper terminals on
both ends of the stripped wire heads. Clamp the copper terminal with a terminal
clamp and put it on the heat shrinkable tube, and blow it with a heat gun until the
glue melts.

3.2.3 Remove the 4 screws of the controller wiring point, and connect the U\V\W of
the motor to the U\V\W terminals of the controller respectively. Connect the power
wire to the R\S\T terminals of the inverter, or connect the DC power supply to the “+”
“-” terminals of the inverter. After the connection completed, use screws to tighten,
then cover the shell, and screw on the bolts.

3.3 Precautions during installation

The cable connection must be firm and reliable.

The bolts must be tightened with spring washer, and pay attention to tightening, the
torque must be sufficient.

After the assembly is completed, all the remaining spare parts and tools are still
needed, and should be kept properly.

3.4 Preparation before commissioning

3.4.1 Operation panel introduction

As a human-machine interface, operation panel can modify the function parameters


of the inverter, monitor the working status and control the operation of the inverter
(start and stop). Its appearance and functional area are shown in the figure below.
9
Schematic diagram of the operation panel

A.Indicator lights description

Items Function Remark

Operation When the inverter is running, the indicator


light is on, and the light is off when the
inverter stops.

Standby If inverter works normally, but due to The difference between standby
timing, pressure, water level, etc., the and stop: Stop means that the
inverter is in a shutdown state, and the inverter stops working, no longer
standby indicator light flashes. When the runs automatically, and is always
conditions are met, the inverter will start in a stopped state.
automatically. After the inverter is running, Standby sleep state means
the standby indicator light will go out. affecting by the external pressure,
water level, or timing conditions,
10
the inverter is in the stop output
state, and other conditions are
met, the inverter will recover
automatically.

Lock When the keyboard is locked, the light is Long press the "Up” and “Down"
on, and if the keyboard is not locked, the button at the same time to unlock.
light is off. When is in the locked state,
press any key, the light will flash to remind
the user that the key has been locked.

Timing When the timing is set and the time is Automatic operation: The inverter
valid, the indicator light will stay on. will be automatically started
according to conditions such as
solar voltage, pressure or water
level. If the timing is valid, only
after the timing is reached, will it
be decided whether to start the
inverter according to other
conditions.

Fault Long light indicates inverter fsult If there is a fault, press the
"Stop/Run" button to clear the
fault.

Solar When the solar light is on, it enters the


solar MMPT state. When the light is off, it
is in AC power supply mode.

Constant When this light is on, it means that the If the pressure is higher than the
inverter enters the constant pressure upper limit pressure, the inverter
pressure mode, and the inverter will determine the will stop.When the pressure in the
output frequency of the inverter through dormant state is lower than the
PID calculation according to the pressure lower limit pressure, the inverter
feedback. will start.

Water level When the light is on, it enters the water The upper limit water level signal
level mode and works automatically and the lower limit water level
according to the water tank float signal need to be connected
externally.

11
Button Function
Remark

In the monitoring interface, if it is in Pressure display


constant pressure mode. Press the description:
pressure key to directly display the S□XX.0 Current pressure
pressure and set pressure. value set.
In the monitoring interface, if you press and F□XX.0 Current pressure
hold the key for 3 seconds, you can directly value feedback .
switch the mode, constant pressure ->
water level mode -> automatic operation When the mode is
mode. The indicator lights corresponding to switched, there is no need
these two modes will light up. If the lights to set parameters, and the
are not on, it is in automatic operation system will automatically
mode. load the default
parameters of the
OK/pressure If enter the menu mode (including the first corresponding mode.
level, second level, and third level), use it
as the "OK" key.

In the monitoring interface, short press can When the solar light is on,
switch different monitoring contents, such it enters the solar power
as operating frequency, operating current, mode. When the light is off,
current feedback pressure, etc., which can it is in AC power supply
be set through P7.03 and P7.04 (see mode.
parameter description).
In the monitoring interface, long press this
key to switch between different power
supply modes (AC power -> solar).
In the menu mode, this key serves as a
shift function.

Both in the running state and the standby


state, you can press this key to stop the
inverter and put it in the stop state. The
"Run" indicator light goes out.
In the stop state, press this key, the inverter
RUN/STOP will automatically enter the standby state,
the standby light will flash, according to the
current external input conditions to decide
whether to start the frequency converter.
When the fault indicator light is on, this key
can be used for fault reset.

12
parameter setting

Menu

C.Key Description

In the monitoring interface, if it is in constant


pressure mode, press this key can enter the
pressure setting interface, and press it again can
increase pressure.
If in the menu mode, this key is used to increase
the value.

In the monitoring interface, if it is in constant


pressure mode, press this key can enter the
pressure setting interface, and press it again can
decrease pressure.
If in the menu mode, this key is used to decrease
the value.

13
D.Wiring
C.1 Main circuit terminall
C.2 Main circuit terminal description

Items Function

grounding terminal

<-> Negative end of DC voltage

<+> Positive end of DC voltage

PB Brake Resistor

R,S,T AC Power in

U,V,W Motor connecting

C.3: Main circuit wiring diagram

<-> <+> PB R S T U V W

AC380V power input Motor

14
C.4:Control circuit terminals description

RS+ RS- GND FWD REV X1 X2 GND FIV FIC GND +24V

RA RB RC

GND Grounding

FWD,REV FWD: foreward

REV:reversal

X1,X2 Multi-function input terminal

FIV Analog input terminal, input voltage range: 0-10VDC

FIC Analog input terminal, input voltage range: 0-10VDC or 4-20mA

+24V Pressure sensor 24V power

RA,RB,RC Relay Output

Name Function

RS+,RS- Standard RS485 Communication connector

C.5: Control circuit terminals description

15
C.5.1 : Basic wiring diagram

16
C.6: Water level mode connection

X1 X2 Command Code

0 0 /

1 0 high water level

0 1 low water level

C.7:Constant voltage mode wiring

pressure sensor

FIV/FIC
pressure
GND
sensor
+24V

Items Parameter values parameter

description

PA.02 0-1(defaults 1) 0:FIV 1:FIC

17
C.8: Menu operation instructions:

The three-level menus are:

a. Function code group number (first-level menu)

b. Function code label (second-level menu)

c. Function code setting value (third-level menu)

Instructions:

When operating in the third-level menu, press the menu key or the OK key to return
to the second-level menu. The difference is: press the OK key to save the setting
parameters into the control panel, and then return to the secondary menu, and
automatically transfer to the next function code; press the menu key to directly
return to the secondary menu without storing the parameters, and keep it Stay at
the current function code.

Specific operation process is shown in the figure below:

18
Eg: Example of changing function code P0.12 from 50.00Hz to 60.00Hz

19
In the third-level menu state, if the parameter has no flashing bit, it means that the
function code cannot be modified. The possible reasons are:

1. The function code is an unmodifiable parameter. Such as actual test parameters,


operating record parameters, etc.;

2. The function code cannot be modified in the running state, and can be modified
only after shutdown;

3.5Common parameters

Item Parameter Parameter description


valus

Function Parameter

P0.01 0 open-loop vector

P0.02 0 0: Keyboard control 1: Terminal control 2:


Communication control 3: Automatic start

P0.03 9 Frequency source (This function will be control by


software automatically )

P0.08 300.00 Operating frequency

P0.10 300.00 Maximum frequency

P0.12 300.00 Upper limiting frequency

P0.14 20.00 Lower limit frequency

P0.17 20.00 Acceleration time

P0.18 20.00 Deceleration time

P4.00 1 Forward running

P4.02 6 High water level

P4.03 7 Low water level

P5.03 34 Dry running Alarm output

P5.04 36 Locked-rotor output

20
P8.34 30% Dry running threshold detection

P8.35 1.00s Dry running time detection

P8.36 160% Locked-rotor threshold detection

P8.37 1.00s Locked-rotor time detection

PID Parameter

PA.02 1 0:FIV 1:FIC

PA.03 0 Direction

PA.05 20.0 Proportional gain

PA.06 2.00s Integral Time

PA.07 0.000s Derivative Time

PA.08 0 PID No Inversion

PA.15 20.0 Proportional gain

PA.16 2.00s Integral Time

PA.17 0.000s Integral Time

PA.18 2 Switch condition

PA.19 10.0% Switch condition

PA.20 50.0% Switch condition

PA.23 1.00% Maximum Peak Forward

PA.24 1.00% Maximum Peak Reverse

21
PA.26 15.0% Pressure sensor missing alarm

Time parameter

PE.00 2018 Year setting

PE.01 03.10 Month and date setting

PE.02 10.50 Hour and minute setting

PE.03 0 Input time setting

PE.04 Keep

PE.05 Keep

PE.06 0730.0 First scheduled start time -hour/minute 7:30

PE.07 2050.0 First scheduled stop time -hour/minute 7:30

PE.08 0 First automatic switch time setting


0 Invalid
1 valid

PE.09 0730.0 Second scheduled start time -hour/minute 7:30

PE.10 2050.0 Second scheduled stop time -hour/minute 7:30

PE.11 0 Second automatic switch time setting


0 Invalid
1 valid

PE.12 0730.0 Third scheduled start time -hour/minute 7:30

PE.13 2050.0 Third scheduled stop time -hour/minute 7:30

PE.14 0 Third automatic switch time setting


0 Invalid
1 valid

PE.15 0730.0 Fourth scheduled start time -hour/minute 7:30

PE.16 2050.0 Fourth scheduled stop time -hour/minute 7:30

PE.17 0 Fourth automatic switch time setting


0 Invalid
1 valid

22
PE.18 0730.0 Fifth scheduled start time -hour/minute 7:30

PE.19 2050.0 Fifth scheduled start time -hour/minute 7:3

PE.20 0 Fifth automatic switch time setting


0 Invalid
1 valid

PE.21 0730.0 Sixth scheduled start time -hour/minute 7:3

PE.22 2050.0 Sixth scheduled start time -hour/minute 7:3

PE.23 0 Sixth automatic switch time setting


0 Invalid
1 valid

PE.27 Automatic start delay

PE.28 Automatic start delay switch

Pump parameter

C9.00 0 DC mode selection


0: AC power supply
1: DC power supply

C9.01 500v Minimum voltage in DC mode

C9.02 0.5HZ Frequency change value of DC mode

C9.03 1 Keep

C9.04 430V Minimum voltage in AC mode

C9.05 0.5HZ Frequency change value

23
C9.06 0.2HZ maximum speed of frequency increase

C9.07 1.0HZ minimum speed of frequency increase

C9.08 21.5kgf. cm2 Full range pressure of pressure sensor

C9.09 5.0kgf. cm2 PID Setting pressure value during control


Constant voltage mode

C9.10 5.2 kgf. cm2 Setting upper pressure limit

C9.11 4.0 kgf. cm2 Setting lower pressure limit

C9.12 30.00Hz Hibernation frequency

C9.13 5.00s Hibernation frequency holding time

C9.14 11 kgf. cm2 High pressure alarm threshold

C9.15 2 kgf. cm2 Low pressure alarm threshold

C9.16 5.0s Alarm time

C9.20 0 Working mode,


0: automatic,
1: constant pressure,
2: water level

C9.22 0 Keyboard lock sign, 1: lock

C9.23 5 Blocked-rotor restart times

C9.24 0 Antifreeze switch (only effective in pressure


mode)
0: invalid
1: Antifreeze time in seconds
2: Antifreeze time in minutes

C9.25 Antifreeze running frequency (only valid in


pressure mode)

C9.26 0s Antifreeze running time (only valid in pressure


mode)

C9.27 Antifreeze interval time (only valid in pressure


mode)

C9.28 1 Is PID valid in DC mode

24
0: invalid 1: valid

Monitor parameter

D0.00 50.00 Operating frequency

D0.02 531.0 Bus voltage

D0.03 320 Output voltage

D0.04 12.00 Output current

D0.05 5.50 Output power

D0.07 0x0000 Terminal status display

D0.10 5.5kg Current pressure display

D0.12 2017 Current time- Year 2017

D0.13 11.22 Current time - Month/Day Nov. 22th

D0.14 13.50 Current time - Hour/minute 13:50

D0.25 10000 Total startup time (s)

D0.26 10000 Total boot time(h)

D0.32 V1.00 Software version

25
3.6 Fault Alarm

Operating Fault Operating display Fault


display

UC Inverterunit protection rAy Contactor fault

OC1 Accelerated Overcurrent IE Current detection fault

OC2 Moderating Overcurrent TE Motor Tuning fault

OC3 Constant overcurrent PG coded disc fault

OU1 Accelerated Overvoltage EEP EEPROM reading and


writing fault

OU2 Moderating overvoltage OUOC Inverter hardware fault

OU3 Constant overvoltage GND Grounded short circuit


fault

POFF Power fault control END1 Cumulative running


time arrival

LU Under-voltage fault END2 Cumulative power pn


time arrival

OL2 inverter overload LOAD Off load fault

OL1 Motor overload PIDE PID feedback loss fault


during operation
(pressure sensor
disconnection)

26
LI Input phase lack CBC Waveband limit fault

LO Output phase lack ESP Excessive speed


deviation fault

OH Overheating Module OSP Motor overspeed fault

EF External device fault ini Initial position error

CE Communication fault E01 short circuit feedback

E02 Missing feedback E03 Dry running alarm

E04 Locked Rotor E05 Leakage alarm

E06 High pressure alarm E07 Low pressure alarm

4.GS high speed AC/DC Hybrid pump model

4GS Model
4GS3/5-1.5N 4GS6/4 4GS12/2-1.5
4GS3/7-2.2N 4GS6/6 4GS12/3-2.2 4GS20/2-2.2
4GS3/10-3N 4GS6/8 4GS12/4-3N 4GS20/2-3N 4GS30/1-3N
4GS3/14-4N 4GS6/1 4GS12/5-4N 4GS20/3-4N 4GS30/2-4N 4GS50/1-4N
4GS3/18-5.5 4GS6/1 4GS12/6-5.5 4GS20/3-5.5 4GS30/2-5.5 4GS50/1-5.5N
4GS3/10-3W 4GS6/8 4GS12/4-3W 4GS20/2-3W 4GS30/1-3W
4GS3/14-4W 4GS6/1 4GS12/5-4W 4GS20/3-4W 4GS30/2-4W 4GS50/1-4W
4GS3/18-5.5 4GS6/1 4GS12/6-5.5 4GS20/3-5.5 4GS30/2-5.5 4GS50/1-5.5W
4GS3/24-7.5 4GS6/1 4GS12/8-7.5 4GS20/4-7.5 4GS30/3-7.5 4GS50/2-7.5W
4GS6/2 4GS12/10-11 4GS20/6-11 4GS30/3-11 4GS50/2-11W

27
5.Start and stop

5.1 Confirm the pump model and cable size first, confirm whether the power supply is
three-phase 380V or DC 500V, and do not connect the wrong power supply.

5.2 After starting, observe whether the current and voltage meet the range, whether
there is abnormal operation and vibration, if it is abnormal, stop pump in time to
processing the fault, then start and test whether it is running well.

5.3 When pump suddenly stops or is triggered automatic shutdown protection, it can
be restarted by unplugging and then plugging in the power supply, but in most cases
the pump will automatically troubleshoot the fault and resume operation.

5.4 Use a new pump to clean the well or pump muddy water is absolutely forbidden.
Check whether the solid content in the water meets the conditions of use in time after
pumping water, if it exceeds, the pump should be stopped.

6.Troubles shooting guide

Troubles Cause Solution

Excessive 1. Bearing weared 1. Replace the bearing

noise and
2. 2. Loose connecting bolts 2. Tighten the bolts
vibration
(separated type factory)

Pump does 1. The cable is too small or 1. Change the cable

not start the wire diameter is too small


2. Check the circuit and change it

2. No power supply
3. Open the pump body and clear the

28
3. Water pump impeller stuck blockage

No water or 1. The water inlet filter is 1. Clear debris

blocked
Insufficient 2. Adjust the depth of the pump

water 2. The water level is too low


3. Check the power supply voltage, power
and the pump is out of the
cord connector and switch on
water

4. Clear debris or change the impeller


3. The motor does not rotate

4. The impeller stuck or worn

Body heat 1. Power lead wire is too thin 1. Change the cable that meets the

requirement
Shutdown 2. Mechanical seal fault

2. Dry the motor and change the


Protection 3. The impeller or rotor is
mechanical seal
start stuck

3. Repair or change
Switch action

7. Completeness and guarantee conditions

This product is generally supplied as a set when it leaves the factory. However, the
cable length and optional accessories are all supplied in accordance with the order
contract. The types of equipment, tools, and accessories are listed in the packing list

29
that comes with the pump.

Our company can choose controllers, cables, etc. according to user requirements.

When the user installs and uses pump according to the provisions of the manual,
within 18 months from the date of shipment from the company, or if the product is
used for no more than 3,500 hours, if this product is damaged due to poor
manufacturing quality and cannot work normally, our company will be responsible
repair or replacement for users free of charge. Normal wear and tear of vulnerable
parts are not included.

Special Note:

1. After dry running protection, wait for 20 minutes before running again, even if it is
powered on again.

2. When the pump is not used for a long time, it must be started at least once a
month and run for more than 0.5 hours each time.

30