Our company is committed to produce such autoclave sterilizer Machines that meet or
exceed industry standards required for effective sterilization. Our autoclaves can be
successfully utilized in many industry sectors including laboratory, healthcare, clinics
and hospitals, pharmaceutical research, tissue culture and agriculture, etc. In
addition to supply pre-engineered standard models, we also manufacture autoclaves with
customer provided specifications with a choice of optional accessories that may be used
to add flexibility in operation.
Vertical Autoclave
Know More
Know More
Know More
1/5
Plasma Sterilizer
Know More
Know More
Rotary Sterilizer
Know More
Know More
Know More
2/5
Know More
Know More
Our Sterilization machines are highly demanded in many industry sectors including
laboratory, healthcare, clinics and hospitals, pharmaceutical research, tissue culture and
agriculture, etc . We also manufacture customized autoclave machines with a choice of
optional accessories that overall increases the effectiveness of the equipment. We
manufacture different kinds of autoclave Machines like Vertical autoclave (top loading),
front loading small, Double door autoclave, Horizontal autoclave, Rotary Sterilizer, Dental,
Plasma Sterilizer to name a few.
3/5
• CE & ISO, IQ / OQ / DQ / PQ Certified
• Requires minimum maintenance
• PAN India Supply
• Premium quality products with manufacturer’s warranty
• 35+ Years Industry experience
• Affordable Pricing
• Strong logistic support in Delhi NCR & India
• Pre-sale and post-sale support services in all India & Overseas
• Satisfied clients base ranging from DRDO, UNIECF to ISRO
There are two types of steam sterilizers, gravity displacement and pre-vacuum
sterilizer. Some autoclave used both methods to sterilize the equipment. The items or
materials which need to sterilize placed inside an autoclave machine and the lid is sealed.
After this, most of air is removed from vessel via two ways. The Gravity displacement unit
pumps steam into the vessel for removing air and for creating a vacuum. A pre-vacuum
design removes the air via a vacuum pump. Once air removal process takes place,
pumping of steam at a high temperature takes place into the chamber. This eventually
leads to increase in temperature. Once, the temperature reaches to the pre-defined
levels, the steam keeps entering into the vessel and the desired temperature is
maintained.
1.Purge Phases: As steam flows, air starts displacing. The pressure and
temperature increase slightly to ensure a continuous flow purge.
2.Exposure Phase: Also known as the sterilization phase, during this phase, the
control system of the autoclave machine is programmed so that the exhaust valve
closed when the pressure and the interior temperature reach the pre-defined point.
This program helps in maintaining the ideal temperature within the closed chamber
till a pre-defined time.
3.Exhaust Phase: In the exhaust phase, the release of pressure takes place from
the closed chamber via an exhaust valve. Once pressure is released, the interior of
the chamber restores the ambient temperature
4/5
What is Ideal Temperature Rage & Time for Autoclave Sterilization?
The autoclave sterilization process takes place at 121°C (250°F) but sometimes,
materials need to sterilize at higher temperatures, say up to 134°C. The sterilization
process of medical equipment takes place when they are placed inside the autoclave for
3 to 4 minutes and for 15-20 minutes. The temperature and time limit may be increased
based on the type of material
1.Vessel:It is the main body of the autoclave and encompasses an outer jacket and
an inner chamber. In hospitals and laboratories, autoclaves have “jacketed
chambers”. These chambers are filled with steam for completing the sterilization
cycle quickly. The inner chambers feature 316 L stainless steel or nickel-clad
whereas outer jackets support 304 L, 316 L or even carbon steel. The size of
vessels used in hospitals and laboratory purposes may vary from 100 to 3,000 L.
2.Control System: :All autoclaves feature a control system either modern or simple
one. The simple control system supports a “push button” system along with a
microprocessor whereas the modern control system equips with a programmable
logic controller along with a touch screen.
3. Thermostatic Trap: A thermostatic trap is a device that helps water and air to
escape from the internal chamber. It is also known as a steam trap and is
considered an important component of a well-designed autoclave
4. Safety Valve: All autoclaves feature scores of safety features and the safety
valve is one amongst many. It is a fail-safe device present in all autoclaves so that
autoclave performs efficiently even under elevated pressure
5. Waste- Water Cooling Mechanism: Some autoclaves have an in-built
mechanism of waste-water cooling that cools air and steam before they enter into
the drain piping.
5/5