Introduction:
This lab demonstrate the testing of a Microstrip Patch Antenna Using Signal Generator ad Signal
Anlyzer. Test Setup includes a Keysight’s N9301A RF Signal Generator, CXA Signal Analyzer,
a Horn Antenna as a Transmitter and a Microstrip Patch Antenna.
Discussion:
Test Setup
N9310A RF Signal Generator
Frequency Range 9 kHz to 3.0 GHz
Frequency Resolution 0.1 Hz
VSWR (typical) < 1.6
RF power +36 dBm
Horn Antenna
Frequency Bandwidth: 1 GHz - 6GHz
Patch Antenna
Resonating Frequency: 2.45GHz
Signal Analyzer N9000B
Frequency range: 100 kHz to 3.0 GHz
Output Power Range −50 to 0 dBm
Output Power Resolution 0.1 dB
Output VSWR (9 kHz to 6 GHz) < 1.5:1 nominal
Conclusion:
In this lab, the operation of Keysight’s RF Signal Generator and Signal Analyzer has been
demonstrated by taking Microstrip Patch Antenna Measurements.
Homework
Peak Power: 20.37dbm
Bandwidth: 2.448GHz-2.452GHz