Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

J4V Series ISO9001:2015 CE

J4V Series
Solenoid Valve Solenoid Valve

Valve Features Valve


Improvement of Flow Performance Indicator
J4V J4V
J4V100 1. The Anti-friction seal is added at both ends of the valve spool to make the valve spool more stable during the switching J4V100
J4V200 J4V200
process and increase the valve life time.
J4V300 J4V300
2. Seals original imported from Japan; Optimize valve body inner flow path; Maximum increase the air flow area.
J4V400 J4V400
3. Valve Piloted Seat is from Taiwan, the surface design with 5 pcs stripe; Increased the strength of Mannual ride spindle; The
5V 5V
appearance is more distinctive (Applied appearance patent).
Manifold Manifold
4. The valve body surface treatment adopts a new environmental protection process.

Working Flow Rate/Lmim


JSY JSY
5JV 5. Fully automated assembling & test line with good product consistency. 5JV
MCS MCS
JVT307 JVT307
JEL JEL
Original J4V
MVSD MVSD
VF Internal Structure New J4V VF
BM BM
Competitor A
NAMUR valve NAMUR
551 551
JEL10 JEL10
3VJZF 6 7 8 9 10 11 12 3VJZF
Diaphragm Diaphragm
JELVD JELVD
型号 110 130C 210 230C 310 330C
3V1 3V1
Coil Original J4V 650 513 920 680 1681 1220 Coil
2P New J4V 610 512 1050 870 1656 1472 2P
2V 2V
5 13 Competitor A valve 570 481 1097 595 1665 1522
2W 2W
2W(Big) 2W(Big)
2L 2L
14
VX VX
4
PU PU
PU225 Improvement of Life-time PU225
2Q 2Q
JEL5404 JEL5404
3
JEL6213 JEL6213
BU BU
2
Pulse Pulse
JEL.JZF JEL.JZF
1
4H 4H
18 17 16 15
TSV TSV
MPV MPV

Respon Time (Ms.)


4HV 4HV
HV, K HV, K
4R 4R
4F210 4F210
FV Par ts FV
MSV MSV
JM Number Name Number Name Number Name JM
ASC, RE ASC, RE
QE, QEA 1 Cross slot pan screw 7 Valve spool 13 Coil QE, QEA
ST Cycle Time ST
2 Back cover 8 Piston 14 Coil nut
HSV HSV
3 Spring 9 Y ring 15 Fix plate

4 Anomalous seal 10 Spring 16 O ring


Turn-on Response Time Turn-off Response Time
5 Valve body 11 Mannual ride spindle 17 Plunger

6 Flat ring 12 Terminal 18 Pilot seat The chart shows that the response time of the solenoid valve is within 25 milliseconds.
The response time of the solenoid valve is minor difference after 40 million lifetime tests.

1-|P01 1-|P02
J4V400 Series ISO9001:2015 CE
J4V400 Series
Solenoid Valve, Air Piloted Valve Solenoid Valve, Air Piloted Valve

Overall Dimension
Valve Valve
J4V J4V
J4V100 J4V100
J4V200 J4V410-15 J4V410-15 J4V200
J4V300 J4V300
J4V400 J3V410-15 4A410-15 J4V400
5V 5V
Manifold Manifold
JSY JSY
5JV 5JV
MCS MCS
JVT307 JVT307
JEL JEL
MVSD MVSD
VF
J4V410-15 J4V420-15 J4V430C-15 VF
BM BM
NAMUR NAMUR
551 551
JEL10 JEL10
3VJZF Ordering Code J4V420-15 J4V420-15 3VJZF
Diaphragm Diaphragm
JELVD
J4V - 4 - 10 - 15 - B - AC220V - W - F JELVD
3V1 3V1
Coil Coil
2P Specification Series Code Coil and Type Port Size Connection and Initial status Standard Voltage Wiring Joint 2P
2V J4V: 5/2 (3) way solenoid valve 4: 400 Series 10: Single coil 15: 1/2″ Blank: Threaded DC12V DC24V Blank: Without light terminal 1F-20F 2V
2W 4A: 5/2 (3) way air pilot valve 20: Double coil B: Sub-plated mounted AC24V 50Hz/60Hz W: Lead wire 2W
2W(Big) J3V: 3/2 way solenoid valve 30C: Mid-position closed (for 5/2,5/3 way only) AC110V 50Hz/60Hz 2W(Big)
2L 3A: 3/2 way air pilot valve 30E: Mid-position exhausted NC: 3/2 way normal close AC220V 50Hz/60Hz 2L
VX 30P: Mid-position pressed NO: 3/2 way normal open VX
PU PU
PU225 PU225
2Q 2Q
JEL5404 JEL5404
JEL6213
Specification JEL6213
BU BU
4V410-15 4V420-15 4V430C-15 4V430E-15 4V430P-15
Pulse Pulse
Model
JEL.JZF 4A410-15 4A420-15 4A430C-15 4A430E-15 4A430P-15 JEL.JZF
4H 4H
Valve Type 5/2 Way 5/3 Way J4V430-15 J4V430-15
TSV TSV
MPV
Effective Cross Section Area 50 mm2 (CV=2.79) 30 mm2 (CV=1.68) MPV
4HV Model 3V410-15 3V420-15 3A410-15 3A420-15 4HV
HV, K HV, K
Valve Type 3/2 Way
4R 4R
Effective Cross Section Area 50mm2 (CV=2.79)
4F210 4F210
FV
Port Size Inlet, Outlet, Exhaust Port = G1/2″ FV
MSV Working Medium 40 Micron Filtered Air MSV
JM Operation Internal piloted JM
ASC, RE Working-pressure 0.15~0.8 MPa ASC, RE
QE, QEA QE, QEA
Max. Test Pressure 1.2 MPa
ST ST
Ambient Temperature -20~70℃
HSV HSV
Operating Voltage Tolerance ±10%
Power Consumption AC: 3.5VA DC: 3.0W
Connector Protection F Class, IP 65
Wiring / Connector Cable / Lead Wire or DIN Connector
Switching Frequency 5 Cycles / Sec.
Response Time 0.05 Sec.

1-|P23 1-|P24
J4V400 Series ISO9001:2015 CE
J4V400 Series
Solenoid Valve, Air Piloted Valve Solenoid Valve, Air Piloted Valve

Overall Dimension Overall Dimension


Valve Valve
J4V J4V
J4V100 J4V410-15B J4V420-15B J4V100
J3V410-15 J3V410-15
J4V200 J4V200
J4V300 J4V300
J4V400 J4V400
5V 5V
Manifold Manifold
JSY JSY
5JV 5JV
MCS MCS
JVT307 JVT307
JEL JEL
MVSD MVSD
VF VF
BM BM
NAMUR NAMUR
551 551
JEL10 JEL10
3VJZF J3V420-15 J3V420-15 3VJZF
Diaphragm Diaphragm
JELVD JELVD
3V1 3V1
Coil J4V430-15B 4A410-15 Coil
2P 2P
2V 2V
2W 2W
2W(Big) 2W(Big)
2L 2L
VX VX
PU PU
PU225 PU225
2Q 2Q
JEL5404 JEL5404
JEL6213 JEL6213
BU BU
Pulse Pulse
JEL.JZF JEL.JZF
4H 4H
TSV 3A410-15 3A420-15 TSV
MPV MPV
4HV 4HV
HV, K HV, K
4R 4R
4F210 4F210
FV FV
4A420-15 4A430-15
MSV MSV
JM JM
ASC, RE ASC, RE
QE, QEA QE, QEA
ST ST
HSV HSV

1-|P25 1-|P26

You might also like