Operating Instructions EN

Ultrasonic sensors following EMC Directive 2014/30/EU


2370-00000190 / 2370-00000186

Product description Intended use Electrical connection Technical data


The ultrasonic sensors Non-contact distance measurement Order number 2370-00000190 2370-00000186
1
described: of lubrication oils and greases in the 2 Blind zone 0 - 65 mm 0 - 120 mm
○ measure the distance to the me- frame of the technical data. U 4
dium without contacting it and 5 Scanning range limit 600 mm 1300 mm
according to their detection area.
Safety instructions 3 Opening angle of the sound beam see detection zones
Read these operating instruc-
○ have a blind zone from which dis- 1 Ultrasonic frequency approx. 400 kHz approx. 200 kHz
tions before the installation and Resolution 0, 18 mm
tance measuring is not possible. 3x
commissioning. 2 5 4 Colour
○ Indicate whether an object is Repeatability ±0.15 %
Installation and electrical connection 3
inside or outside of the pre-set Detection zone in centimetres
by authorized qualified personnel 20 10 0 10 20 cm 40 20 0 20 40 cm
limits (see table Display of the 1 + UB brown The light grey areas indicate the zone 0 0
only.
switching states) 3 - UB blue in which a big reflector – like, e.g. a
○ have an internal temperature Installation and commissioning lubricant surface – is still detected 10 A
20
4 D2 black
compensation. Due to the •  Clean the installation surface. – provided it is optimally positioned 40
self-heating of the ultrasonic When doing so make sure that no 2 D1 white to the sensor. Outside the light grey 20
sensors the temperature com- dirt enters the reservoir. 5 D3/Com grey area an evaluation is not possible any B
60
pensation reaches its optimum •  Mount the ultrasonic sensor more. 30
operating point after an operating with the sensor surface (white 35 80
time of about 30 minutes.
Cleaning 40
area) centrically above the bore
Clean the sensor surface (white
○ The related switching outputs are (Ø 20 mm) into the reservoir lid. 100
area), if it is contaminated.
set depending on the preset switch •  Connect the connection cable to 50
120
points. the M12 plug. Maintenance
60
•  Switch the power supply on. The ultrasonic sensors do not require
Regulatory notes 140
any maintenance. cm cm
Electrical equipment according to
EMC 2014/30/EU Accuracy ±1 %
no safety components Operating voltage UB 9 - 30 V DC protected against reverse polarity
acc. to Residual ripple ±10 %
machinery directive No-load current consumption ≤ 60 mA
2006/42/EC Housing material PBT, polyester, ultrasonic transducer: PUR, epoxy resin with glass contents
Dimensions Type of connection 5-pole M12 circular socket connector
7,6 5,2 M = 1,5 Nm ± 0,2 Nm
Type of protection following EN 60529 IP 65/ 67 (depending on the cable socket used)
8,5

Display elements LED green / LED red | Switching output not set/ set
26,7

Range of operating temperatures -40 °C to + 70 °C


13,3 13,3
62,2

Weight 120 g
47
5,2

11

Response delay 272 ms 340 ms


31,1 31,1
Readiness delay < 300 ms
Compliance with standards EN 60947-5-2
T1 D1 D2 T2 Setting elements 2 pushbuttons
Enclosure type 1 3x pnp; UB-2V; Imax = 3x 200 mA; selectable between NO contact/ NC contact,
7,6

For use in industrial machinery Switching output


O ring NBR 44x2 M12x1 short-circuit resistant
NFPA 79 applications only
High-level indication 065 mm 120 mm
Factory
Pre-low-level indication 410 mm 730 mm
setting
Manufacturer: SKF Lubrication Systems Germany GmbH, Heinrich-Hertz-Str. 2-8, DE-69190 Walldorf Low level indication 420 mm 780 mm
© Copyright SKF
Document no.: 951-181-031-EN / State of the information: 2021/07/27 / Version 02 1/ 4
○ During standard operation a red LED signals that the
Reset to factory setting ○ In the Teach-in procedure »Set switch point – Method corresponding switching output has switched. The
Activate / deactivate Teach-in
A« the sensor learns the actual distance to the object switching status of D3 is indicated by the two flashing
to be the switch point. In case of the object moving LEDs.
towards the sensor, e.g. when measuring the filling ○ The sensor can be reset to factory setting (see sensor
level, the taught-in distances is the level where the setting with Teach-in).
sensor is to switch.

○ To sensor objects entering the sound field later- The high-level indication of the ultrasonic
ally, the Teach-in procedure »Set switch point +8 sensors described in these instructions has
% – Method B« should be chosen. There will be set been programmed unchangeably by the
a switch point exceeding the actual distance to the manufacturer (switch point D3 / 65 mm re-
Switch the power supply off Switch the power supply off
object by 8 %. By doing so a stable switch point will be spectively 120 mm). The low-level indication,
ensured even in case of minor height fluctuations. and as the case may be, the pre-low-level
or pre-high-level indications may be freely
Set switch point - Method A programmed by the programmer on switch
points D1 and D2 via the described method.
Switch on power supply while pushbut- Switch on power supply while pushbut-
ton T1 is pressed ton T1 is pressed

Display of the switching states


Switch
Indication by LED
points
Keep pushbutton T1 pressed for Keep pushbutton T1 pressed for about
about 3 seconds until both LEDs flash 13 seconds until both LEDs flash D1 D2 D3 D1 D2
simultaneously alternately
High-level indication A A A green green D
LED D2 flashes
Between high- and
LED D1 ON: teach in activate pre-low-level A A B green green C
OFF: teach in deactivate indication
-----------------------------------------------
Pre-low-level signal B A B orange green C
Set switch point +8 % - Method B
Low level indication B B B orange orange C
A = switched C = permanent
B = not switched D = flashing
To activate / deactivate
keep pushbutton T1 pressed
for about 1 second

T1 D1 D2 T2

Wait 10 seconds

Standard operation

Manufacturer: SKF Lubrication Systems Germany GmbH, Heinrich-Hertz-Str. 2-8, DE-69190 Walldorf 2/ 4
© Copyright SKF
Document no.: 951-181-031-EN / State of the information: 2021/07/27 / Version 02
Sensor setting with Teach-in: Set switch point D1

1 1
1 2
1
85 %

Set switch point D1 Set switch point D1 D1 D1 D1


- Method A + 8 % - Method B Set window characteristics Set the two-way reflector barrier Set the NC contact/ NO contact

Position object at 1 Position object at 1 Position object at 1 Position reflector at 1

Keep pushbutton T1 pressed for Keep pushbutton T1 pressed for Keep pushbutton T1 pressed for Keep pushbutton T1 pressed for Keep pushbutton T1 pressed for about
about 3 seconds until both LEDs flash about 3 seconds until both LEDs flash about 3 seconds until both LEDs flash about 3 seconds until both LEDs flash 13 seconds until both LEDs flash
simultaneously simultaneously simultaneously simultaneously alternately

Both LEDs flash alternately LED D2


flashes

LED D1 ON: Normally


Position object at 2 open contact
OFF: Normally
closed contact
Both LEDs flash alternately
To change the initial function
keep pushbutton T1 pressed
for about 1 second
Keep pushbutton T1 pressed for about
Press the T1 pushbutton for about 1 Press the T1 pushbutton for about 1 Press the T1 pushbutton for about 10
second. 3 seconds until both LEDs flash alter-
second seconds
nately again

Wait 10 seconds

Standard operation

Manufacturer: SKF Lubrication Systems Germany GmbH, Heinrich-Hertz-Str. 2-8, DE-69190 Walldorf 3/ 4
© Copyright SKF
Document no.: 951-181-031-EN / State of the information: 2021/07/27 / Version 02
Sensor setting with Teach-in: Set switch point D2

1 1
1 2
1
85 %

Set switch point D2 Set switch point D2 D2 D2 D2


- Method A + 8 % - Method B Set window characteristics Set the two-way reflector barrier Set the NC contact/ NO contact

Position object at 1 Position object at 1 Position object at 1 Position reflector at 1

Keep pushbutton T2 pressed for Keep pushbutton T2 pressed for Keep pushbutton T2 pressed for Keep pushbutton T2 pressed for Keep pushbutton T2 pressed for about
about 3 seconds until both LEDs flash about 3 seconds until both LEDs flash about 3 seconds until both LEDs flash about 3 seconds until both LEDs flash 13 seconds until both LEDs flash
simultaneously simultaneously simultaneously simultaneously alternately

Both LEDs flash alternately LED D1


flashes

LED D2 ON: Normally


Position object at 2 open contact
OFF: Normally
closed contact
Both LEDs flash alternately
To change the initial function
keep pushbutton T2 pressed
for about 1 second
Keep pushbutton T2 pressed for about
Press the T2 pushbutton for about 1 Press the T2 pushbutton for about 1 Press the T2 pushbutton for about 10
3 seconds until both LEDs flash alter-
second second seconds
nately again

Wait 10 seconds

Standard operation

Manufacturer: SKF Lubrication Systems Germany GmbH, Heinrich-Hertz-Str. 2-8, DE-69190 Walldorf 4/ 4
© Copyright SKF
Document no.: 951-181-031-EN / State of the information: 2021/07/27 / Version 02