W0811081 (220V)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

I

NSTRUCTI
ON MANUAL
SALAD PREP TABLE
PIZZA PREP TABLE
UNDERCOUNTER
WORKTOP
CHEF BASE

FREEZER:
MGF8405 MGF8406 MGF8407
MGF8412 MGF8413 MGF8414

REFRIGERATOR:
MGF8401 MGF8402 MGF8403 MGF8404
MGF8408 MGF8409 MGF8410 MGF8411
MGF8450 MGF8451 MGF8452 MGF8453
MGF8454 MSF8301 MSF8302 MSF8303
MSF8304 MSF8305 MSF8306 MSF8307
MSF8308 MPF8201 MPF8202 MPF8203

Pl
easer
eadt
heuser
’smanualbef
oreyouuset
hispr
oduct
.
I
fyour
equestunnecessar
yser
vices,youmaywast
emoney.
Thus,f
ixsi
mpl
etr
oubl
esbyyour
sel
fwhi
chyouhavef
ound.
I
nst
all
ati
on,useandmai
ntenancei
nst
ruct
ions
I
NDEX

1I
ntr
oduct
ion....
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
2
2Manuf
acturer'sret
ainedrightsandresponsibi
li
ty.
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
2
3Tr
ansport
ationandst orage..
...
..
..
..
..
..
..
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
3
4Commissi
oni ng..
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
3
4.
1Posit
ioning.
..
..
..
..
..
...
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
3
4.
2Ini
ti
alcleani
ng..
..
..
...
...
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
4
4.
3Connect i
ontoelectr
icalsuppl
y..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
4
4.
4Connect i
ontodrains..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
5
5Techni
calcharacteristi
cs..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
...
..
..
..
...
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
6
5.1Noiseandvi bration..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
...
..
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
6
5.2Possibl
eappl ications.
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
...
..
..
..
..
...
..
..
..
..
...
..
..
..
..
..
..
..
..
..
6
6Usage.
...
..
..
..
..
..
...
....
...
...
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
...
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
6
6.1Acti
vati
on...
..
....
...
...
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
...
..
..
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
6
6.
2St orageoff ood-stuff
s..
..
...
..
...
...
...
..
..
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
.6
6.
3Def r
osti
ng..
...
...
..
...
..
...
..
..
...
..
...
...
...
..
..
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
.7
6.3.1Defrosttimer..
...
..
...
..
..
...
...
...
..
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
...
7
7Maintenance....
..
...
...
..
..
...
..
..
...
..
...
...
...
..
..
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
...
7
7.
1Per i
odiccl
eani ng..
..
...
..
..
...
..
...
...
...
..
..
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
...
7
7.
2Cl eaningofcondenser ..
...
..
...
...
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
.7
7.
3Per i
odofinactivit
yofcabi net...
..
..
..
..
...
..
..
..
...
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
.8
8Troubleshoot i
ngandr emedi es..
...
...
..
..
..
...
..
..
..
..
...
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
.8
8.
1I fthecabinetdoesnotoper ate..
..
..
..
...
..
..
..
..
...
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
.8
8.
2I ftherequir
edt emper atureisnotachi eved...
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
.8
8.
3I fthecabinetleakswat er...
...
...
..
..
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
...
9
8.
4I fthecabinetisunaccept ablynoi sy..
..
..
..
..
...
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
...
9
8.
5I mprobabler i
sks...
..
...
..
..
...
..
...
...
...
..
..
..
..
...
..
..
..
...
..
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
.9
9Subst i
tut
ionofspar es..
...
..
..
...
..
...
...
...
..
..
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
.10
10Dismant li
ng.
...
...
..
...
..
...
..
..
..
...
...
...
...
..
..
..
..
...
..
..
..
..
...
..
..
..
...
..
..
..
..
..
..
..
..
..
..
..
..
..
.10

Operati
ngInstr
ucti
on.
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
10
Techni
calParameter
s..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
15
Of
fi
ci
alAppr
ovalAndRul
es.
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
17
Cor
rectdi
sposaloft
hispr
oduct
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
17

1
1I
NTRODUCTI
ON

Thisequipmenthasbeenpr oducedbei nt
ernall
yorexternall
yinits
aesthet
icsandcomponabi l
it
y.Inr
esponset othespecifi
cexigenciesof
ourcli
entel
e;f
urthermoreithasbeenmechani cal
lyandaest heti
call
y
checkedineveryaspectbeforedespatch.Forthecorrectuti
li
sati
onof
theequipment;caref
ull
yreadtheinst
ructi
ons,observeallthe
recommendat i
onscontai
nedtherei
n,consignt
hismanualwhi
chconst
it
utes
anintegralpar
toftheessenceoftheequipmenttot
heenduserwhois
requestedtoret
ainitf
orfut
ureconsul
tat
ion.Byobser
vingt
hese
recommendat
ions,youwi
l
lguar
ant
eet
heext
endedt
roubl
e-f
reeoper
ati
on
oftheequi
pment.

2MANUFACTURER'S RETAI
NED RI
GHTS AND
RESPONSI
BILI
TY

I
tisf
orbi
ddentorepr
oduce,part
ial
l
yort
otal
ly,t
hesei
nst
ruct
ionswi
thout
t
heexpressaut
hori
sati
onofthemanuf
actur
ers.

Themanufactur
ersdenyallresponsi
bil
i
tyt
ot hi
rdpar
ti
esinconsequenceof
:
-Nonobservanceofthewarningsandinstr
ucti
oncontai
nedint
het est
;
-Nonobservanceoftheparamet er
sofuti
l
isati
onoft
heequipment;
-Unreasonabl
eorwr ongfulut
il
i
sati
onbyun- tr
ainedpersonnel
;
-usenonconformingtolocalstat
utes;
-Unauthori
zedmodifi
cati
onsand/orr epai
rsundert
akenbynont r
ainedor
authori
zedpersonnel.
-Uti
li
sati
onofnonor i
ginalsparesoraccessori
es;
-Excepti
onaloccur
rences;
-I
mpr eci
seinst
ruct
ionscontainedforwhateverreasoni
nthecur
rentmanual
;

2
Themanuf act
urer
sreser
vether
ightt
oint
roduceanymodi
fi
cat
i
ondeemed
necessar
ywi t
houtwarni
ng.

4COMMI
SSI
ONI
NG

Careful
l
yr eadthelabelontheequipment,donotcoverf
oranyr
eason
whatsoever.andreplacethem immedi
atel
yifdamaged.Donotr
emove
pr
otecti
onorpanel l
ingthatrequi
ret
heusageoftools.

4.
1POSI
TIONI
NG

Ensur ethatinrespectoft hedi mensions,thespacer eservedf orthe


equipmentper mitsit
scor rectut i
li
sati
onandeaseofmai ntenance.After
carefull
yunpackingt hedi splaycase,removet hewhi t
ePVCpr otecti
ve
fi
l
m andal loft
he manuf acturer'
smat eri
alwhichsafeguar dsthei t
em in
tr
ansit.Placethecabi netonaf latsurf
aceandl eveli
tbyscr ewingand
adjusti
ngt heleveli
ngl egstoensur ei
tseffi
ci
entoperat i
on.Thecabi net
mustbel i
ftedonlyfr
om t heext eri
orofthebaset oavoi dthepossi bi
li
tyof
damage.Donotmovet hecabi netbyapplicat
ionofpr essuretot hesurf
ace.

3
i
fthedevi
cehasbeenposi
ti
onedhor
izont
all
y
(i
ntegralcondensi ngunit)
.waitt
wohour s
beforeactivati
ngit.Packi
ngandpr ot
ecti
ve
f
il
m shoul dbedi sposedoffasindi
cat
edby
t
hel ocalauthorit
ies.Theequipmentmust
notbei nst
alledwi t
hinexpl
osi
veambl ence,
Intheopenai rorexposedt or ai
nt hecorrect
sit
ingi s;di
stantf
rom directsources(r adiat
ors,
dir
ectl ight
ing,et
c..
.)andpr otect
edf rom dir
ect
sunlightanddr aughts.Aircir
culati
onmustbef r
eely
mai ntainedaroundthecondensi ngunit,beitintegr
alorr
emot
e.
Inobser
vanceoft
hesespeci
fi
ccondi
ti
onswi
l
ldet
ri
ment
all
yaf
fectt
he
cabi
net.

4.
2INI
TIALCLEANI
NG

Befor
euseallpar
tsofthecabi
netshoul
dbe
cl
eaned,Fort
hewallsandallt
heint
ernalpar
ts
useanant i
bact
erialdet
ergent.Fort heplast
ic
partsuseamoi st
enedcloth.Drywi thasof t
cl
eancl oth.useli
ttl
eornowat er.
Donotusehar shorabrasivesol ventsor
detergents
Duringcleaningdonotappr oachbar e-
handedthosepart
swhichcoul
d
cut(evapor at
or,condenser,etc.)andalwaysusepr ot
ect
ivegl
oves.

4.
3El
ect
ricalconnect
ion

Checkt
hatt
hesuppl
yconf
ormst
other
equi
rement
sli
stedont
hef
act
ory
l
abelandt
hati
tispr
ovi
dedwi
t
haf
all
-saf
epr
otect
ionoraut
omat
icci
rcui
t

4
br
eakerwi
thanef
fi
ci
entear
thconnect
ion. Gr
oundi
ngTer
minal

Shoul
dther
enotbeanel
ect
ri
calsaf
ety
f
eat
urehavet
hisi
ntr
oducedbyaqual
i
fi
ed AC220V
Out
letOnl
y
per
son.bymeansofaomni
pol
arswi
tch
asi
ndi
cat
edi
nthesaf
etyr
egul
ati
onswi
t
h
ameansofaomni
pol
arswi
tchasi
ndi
cat
ed
i
nthesaf
etyr
egul
ati
onswi
thami
nimum
cl
ear
anceoft
hecont
act
sof3mm.
wher
ethecabi
nethast
obei
nst
all
edat
somedi
stancef
rom t
heel
ect
ri
calsour
ce.
ensur
ethatt
heconf
ormst
othel
ocal
r
egul
ati
ons.Cabi
netsuppl
l
edwi
t
h
i
ntegr
alcondensi
nguni
tsar
e
pr
ovi
dedwi
thanappr
opr
iat
epl
ugf
it
ted
wi
thaneut
ralandear
th;t
hesuppl
y
cabl
e mustbewel
lst
ret
ched(
avoi
d
coi
l
li
ngandsuper
imposi
ti
on)
.itmust
notbeexposedt
othepossi
bil
i
tyofdamagebyt
hir
dpar
ti
es.i
tshoul
dnot
bei
ncont
actwi
thl
i
qui
ds,wat
erorheatsour
ces.i
ntheeventofdamagei
t
mustber
epl
acedbyqual
i
fi
edper
sonnel
.Al
waysavoi
dtheuseofr
educer
s
oradapt
ers.

4.
4CONNECTI
ON TO DRAI
NS

Thedi
sper
salofdef
rostwat
eri
saut
omat
i
cinal
lmodel
swi
thi
ntegr
al
condensi
nguni
t.

5
5TECHNI
CALCHARACTERI
STI
CS

5.
1NOI
SE AND VI
BRATI
ON

Thesoundl
eveloft
heequi
pmentf
it
tedwi
thi
ntegr
alher
met
iccondensi
ng
uni
tdoesnotexceed70dB,
iti
sther
efor
enotnecessar
ytopr
ovi
desound
i
nsul
ati
on.Undernor
malcondi
ti
onst
heequi
pmentdoesnotgener
ate
vi
brat
i
onswhi
chaf
fectsur
roundi
ngs.

5.
2POSSI
BLE USAGES

Donotut
i
li
set
heequi
pmentt
ost
oremedi
calsuppl
i
es.
t
heopt
imum oper
ati
onalambi
entt
emper
atur
esar
ebet
ween
+10℃ /+40℃.
Thepossi
bleappl
i
cat
i
onar
eshowbel
ow:
sal
ad,
ref
ri
ger
ati
on,
pr
epar
ati
on,andsal
eofsal
ads,f
rui
ts.Veget
abl
esandcol
ddi
shes.

6USAGE

6.
1ACTI
ON

Powerconnect
i
onandadj
ustt
het
her
most
at.

6.
2STORAGE OFFOOD-
STUFFS

I
nor dert
oobtai
nthebestfunct
ioni
ngoft
hecasei
tisnecessar
yto
observet
hefoll
owi
nginst
ructi
on:

6
-Placethemer chandiseintotheunitonlyaft
erithasreachedthe
desi
redoperati
ngt emper at
uregivenont hedigi
taldi
spl
ay.
-Donotpl aceuncover edhotfoodsorliquidsi
nsidetheunit
-Packageorpr otectfoodswhenpossi ble
-Donotl i
mitthecirculat
i
onofai ri
nsidethecallwit
hsuperfl
uous
obstacl
es.
-Avoidfrequentorpr
olongedopeni
ngsoft
hedoor/dr
awers
-Waitaf ewmoment sbeforer
eopeni
ngthedoor/
drawerj
ustaf
teri
t
hasbeencl osed.
Whil
ststocki
ngonlyopenandf i
l
ladraweratati
met oel
imi
natet
herisk
ofover
-bal
anci
ngoraskt
othesuppl
i
ert
hef
ixabl
efeet
s.

6.
3DEFROSTI
NG

6.
3.1DEFROST TI
MER

Thedef
rostt
imeraut
omat i
cal
l
y4t i
mesi
n24hour
s,i
t
sti
merwi
l
lreset
t
otheti
meoft hei
nit
ialf
ir
stst
art
-up.

7MAI
NTENANCE

7.
1PERI
ODI
C CLEANI
NG

Forhygienicreasonsandi
mprovedper
for
mancecl
eanatleastoncea
weekthei nter
nalbasi
n.Makesureswi
t
chofft
hepowersupplybefor
e
cl
eaning..

7.
2CLEANI
NG OFCONDENSER

Fori
mpr
ovedper
for
mancecl
eant
hecondenseratl
eastonceamont
h.
7
Bef
orebegi
nni
ngturnofft
heequipment,anddisconnectt
heplug.
Cl
oseandprot
ecttheunit
.
-Unscr
ew,rot
ateandremoveprotect
i
vegr i
ll
-Removethedustdeposi
tedonthefrontsurf
aceofthecondenser
usi
ngabrushandavacuum cleanerandr est
oreprevi
ouscondit
ions.

7.
3PERI
OD OFI
NACTI
VITY OFCABI
NET

Dur
ingper iodsofinacti
vity,r
emovet hepr
oductsf
rom t
hecabi
netand
t
henf ol
lowt hesedirect
ions:
-Removet heplugoutf rom theout
letand
carefull
ycleantheuni tasperperi
odiccleani
ng
-Covert hecabinetwhitacl otht
hatall
owsair
ci
rculati
oni ntheinter
ior.

8TROUBLE SHOOTI
NG AND REMEDI
ES

Oft
en,t hemalfuncti
onofaunitisduetosimpl
ecauseswhi
chcaneasi
l
y
beeliminat
edwi thoutcont
act
ingatechnici
an.
Thereforeexecutethefoll
owi
ngcontrol
s

8.
1Ift
hecabi
netdoesnotoper
ate,
makesur
ethat
:
-Theplughasbeencorr
ectl
yinser
tedi
ntot
hesocket
.
-Thesuppl
ycordisnotdamaged.

8.
2Ift
her
equi
redt
emper
atur
eisnotachi
eved,makesur
ethat
;
-Thecommandswi
t
chi
stur
nedon.
-Thet
her
most
atr
angei
scor
rect
l
yregul
ated.

8
-Thecabinetisneit
herinthedefr
osti
ngphasenorinthe
post
-defr
osti
ngpase.
-Theevaporatorisnotcoveredwit
hfrost.
-Thecondenseri snotblockedwi
thdust.
-Thecabinetisnotlocat
ednearheatsourcesori
tscondensi
nguni
t
hasuninter
ruptedairfl
ow.
-Thestoredfoodsorotherobject
sdonotinhi
bitpropercl
osingof
t
heunit
.
-The cabineti
snotworkinginanomal
ouscondi t
ions(overl
oaded,l
oadedwi t
hhotfood,orloadedinawaythatpreventsproperai
r
ci
rcul
ati
on) .

8.
3Ift
hecabi
netl
eakswat
er,maket
hat
:
-Thecoll
ecti
ngcontai
nerorthedeviceforcondensi
ngwat
er
el
imi
nationarenotdamaged.
-Thedischar
geoutlet
sarenotblockedorobstruct
ed.
-Thecabinethasbeenproperl
yleveled.

8.
4Ift
hecabi
neti
sunaccept
abl
ynoi
sy,makesur
ethat
:
-Thefr
amedoesnothaveloosescrewsorbolt
s.
-Thecabi
nethasbeenl
aidinastableposi
ti
onandcor
rect
lyl
evel
ed.

I
f,af
terallthesecont r
ols,themalf
uncti
oningcont
inues,iti
sadvisabl
e
t
ocontactt echnicalassi
stance.Bepreparedtosupplythefol
l
owi ng
i
nfor
mation:
-Themodelt radenameandt heser
ialnumber(bothcanbef ound
onthet echnicaldataplate).

8.
5IMPROBABLE RI
SKS
I
ncaseoff i
reunpl
ugt
hecabi
net
,ifpossi
ble,anduseapowderf
ir
e
ext
ingui
sher.
9
9SUBSTI
TUTI
ON OFSPARES

Befor
ecommenci nganyser viceormai
ntenancework,i
sol
atethecabi
net
fr
om theelectr
icalsuppl
y.
Alwaysfi
torigi
nalspareswhi chmaybeobt ai
nedfr
om anauthori
zed
concessi
onaireorstocki
st.

10DI
SMANTLI
NG

Thescr appingoft hecabinetrequirest obeunder takenbyspeciali


zed
company,l i
censedbyt helocalaut horit
ies,andobser vi
ngl
ocalstatut
es.
Pol
yur ethanef oami ngmateri
al,notf i
re-resi
stant
,whendealwiththe
material,shouldbeaccor dingwithl ocallawandst atue.
-Thecabi netconsistsof:
-Structureinst eelplat
e,
-Electri
calcomponent sandcabl es,
-Electri
calcompr essor
.
-Plasticmat eri
als,
-Ref r
igerantfl
ui dwhichmustnotbedi schargedintotheat
mospher e.

Oper
ati
ngI
nst
ruct
ion

1.Newupr i
ghtai r
-cooli
ngr efr
igerat
ors houl dbe
openedandv entil
ateitbeforeiti
si nus e.After
t
hat ,us erss houldus ewar m waterc l
eani tsinsi
de.
2.Afterc onnec ti
ngt hepowers upply,presst he
“POWER”s wit
chont hecont r
oll
erk eyboar d(GreenI ndi cat
orLi ghtON) ,
t
hef ri
dgewi l
lcomet owor k.Themi crocomput erc ontroller
,install
edin
t
hec ont r
ollerkeyboar d,couldautomat i
c all
yadjustt het emper ature
ranges .Thi sint
elli
gentdigitalcont
r ol
l
erwor ksas:i fthet emper ature
i
nc reas esandr eachess etpointplusdifferenti
althec ompr essori s
startedandt hent ur
nedof fwhent het emper aturer eac hest hes etpoint
valueagai n.

10
3.Mi
croc
omput
erContr
oll
erOper
ati
onI
nst
ruc
tion:
4.Mi
croc
omput
erpanelsket
chmap,
meani
ngsofrunni
ngindi
cat
orli
ght
andLEDshowing.
5. Todispl
aytar
getsetpoi
nt,i
n
pr
ogr
ammi
ngmodei
tsel
ect
sapar
amet
er (
Mod.XR06CX)

 orconf
ir
m anoper
ati
on.
     Tos tar
tamanualdef
rost

     I nprogr
ammi ngmodei
tbr
owsest
hepar
amet
ercodesor
i
ncr
easesthedispl
ayedval
ue.
Inprogr
ammi ngmodei
tbr
owsest
hepar
amet
erc
odesor
decr
easesthedispl
ay edvalue.
Tolockorunloc kt
hek eyboard
Toenterinprogrammi ngmode
Toretur
nt oroom temperatur
e
di
spl
ay.
6.Howtoseethepoint.
Pus
handi
mmedi
atel
yrel
easet
heSETkey,t
hesetpoi
ntwi
l
lbeshowed;
Pushandi
mmediat
elyr
eleaset
heSETkeyorwai
tabout5st
oret
urn
tonor
malvi
sual
i
sat
ion.
7.Howt ochangethesetpoint.
PushtheSETk eyformor ethan2secondst
ochangetheSetpointvalue;
Thevalueofthesetpointwil
lbedi
spl
ayedandthe“°
C”or“°F”LEDs tarts
bl
inki
ng;
TochangetheSetval
uepus hthe or ar
rows
.
Tomemor i
sethenews etpoi
ntval
uepusht
heSETk eyagai
norwai
t10s
.
8.Howtostartamanualdefr
ost.
PushtheDEF k
eyf
ormor
ethan2secondsandamanualdef
rost
wi
ll
s t
art.

11
9.Howt
ochangeapar
amet
erval
ue
Tochanget
hepar
amet
er’
sval
ueoper
ateasf
oll
ows:
Ent
ert
hePr
ogr
ammi
ngmodebypr
essi
ngt
he keysf
or3s
(
“°C”or“
°F”LEDst
art
sbl
i
nki
ng)
.
Sel
ectt
her
equi
redpar
amet
er.Pr
esst
he“
SET”keyt
odi
spl
ayi
tsval
ue
Us
e or t
ochangei
tsval
ue.
Pr
ess“
SET”t
ost
oret
henewval
ueandmovet
othef
oll
owi
ngpar
amet
er.
Toexi
t:Pr
ess orwai
t15swi
thoutpr
essi
ngak
ey.
NOTE:t
hesetval
uei
sst
oredevenwhent
hepr
ocedur
eisexi
tedby
wai
ti
ngt
het
i
me-
outt
oexpi
re.
10.Tol
ockt
hekey
boar
d.
Keeppr
essedf
ormor
ethan3st
he keys.
The“
OF”messagewi
l
lbedi
spl
ayedandt
hekeyboar
dwi
l
lbel
ocked.
I
fakeyi
spr
essedmor
ethan3st
he“
OF”messagewi
l
lbedi
spl
ayed.
11.Tounl
ockt
hek
eyboar
d.
Keeppr
essedt
oget
herf
ormor
ethan3st
he keyst
il
lthe“
on”
messagewi
l
lbedi
spl
ayed.
12.Al
armsi
gnal
l
ing.

12
Tabl
eoff
unct
ionsact
ivat
edbyt
hebut
tons Tab.
2

13
14
Techni
calPar
amet
ers

☆UNDERCOUNTE & WORK TOP

Rating frequency
Power source (V)

Dimension (mm)
Input power (w)

Net Weight (kg)


Temperature

Capacity (L)
Model code

Refrigerant
range (℃
)
MGF8401 220 50Hz 200 +1~+8 R134a 184 698 ×762×929 85

MGF8402 220 50Hz 290 +1~+8 R134a 340 1225×762×929 105

MGF8403 220 50Hz 290 +1~+8 R134a 506 1530×762×929 130

MGF8404 220 50Hz 290 +1~+8 R134a 538 1846×762×929 160

MGF8405 220 50Hz 260 -22~-17 R134a 184 698 ×762×929 85

MGF8406 220 50Hz 500 -22~-17 R404a 340 1225×762×929 105

MGF8407 220 50Hz 500 -22~-17 R404a 506 1530×762×929 130

MGF8408 220 50Hz 200 +1~+8 R134a 184 698 ×762×995 85

MGF8409 220 50Hz 290 +1~+8 R134a 340 1225×762×995 105

MGF8410 220 50Hz 290 +1~+8 R134a 506 1530×762×995 130

MGF8411 220 50Hz 290 +1~+8 R134a 538 1846×762×995 160

MGF8412 220 50Hz 260 -22~-17 R134a 184 698 ×762×995 85

MGF8413 220 50Hz 500 -22~-17 R404a 340 1225×762×995 105

MGF8414 220 50Hz 500 -22~-17 R404a 506 1530×762×995 130

NOTES:
I
fthet
echni
caldat
ahasanychanges,wewi
l
lnotnot
if
yyouanyl
onger
.

15
Techni
calPar
amet
ers

☆SALAD PREP TABLE & PIZZA PREP TABLE&CHEF BASE

Rating frequency
Power source (V)

Dimension (mm)
Input power (w)

Net Weight (kg)


Temperature

Capacity (L)
Model code

Refrigerant
range (℃)
MGF8450 220 50Hz 260 +1~+8 R134a 215 1230x815x520 100

MGF8451 220 50Hz 260 +1~+8 R134a 235 1318x815x520 104

MGF8452 220 50Hz 260 +1~+8 R134a 235 1536x815x520 106

MGF8453 220 50Hz 350 +1~+8 R134a 340 1840x815x520 136

MGF8454 220 50Hz 350 +1~+8 R134a 340 1930x815x520 140

MSF8301 220 50Hz 350 +1~+8 R134a 184 698x762x1109 90

MSF8302 220 50Hz 370 +1~+8 R134a 340 1225×762x1109 110

MSF8303 220 50Hz 370 +1~+8 R134a 516 1530×762×1109 150

MSF8304 220 50Hz 430 +1~+8 R134a 538 1846×762x1109 170

MSF8305 220 50Hz 270 +1~+8 R134a 184 1230×863x1183 90

MSF8306 220 50Hz 370 +1~+8 R134a 340 1318x863x1183 110

MSF8307 220 50Hz 370 +1~+8 R134a 516 1536×863x1183 150

MSF8308 220 50Hz 430 +1~+8 R134a 538 1930×863x1183 170

MPF8201 220 50Hz 280 +1~+8 R134a 396 1117x840x1035 140

MPF8202 220 50Hz 410 +1~+8 R134a 566 1701×840x1035 249

MPF8203 220 50Hz 500 +1~+8 R134a 736 2362×840x1035 350

NOTES:
I
fthet
echni
caldat
ahasanychanges,wewi
l
lnotnot
if
yyouanyl
onger
.

16
Of
fici
alAppr
ovalAndRul
es
Ourpr
oduct
sful
lfi
l
lthepr
esentE.
U.r
ules,i
ncl
udi
ngt
heCEmar
koft
he
Eur
opeanof
fi
ci
alappr
oval
Lat
estvers
ionoff
oll
owi
ngdir
ect
ivesands
tandar
ds
2006/
42/EC 2014/
30/
EU
2012/
19/
EU 2011/
65/
EU
EN60335-
1 EN60335-
2-89
EN62233 EN55014-
1
EN61000-
3-2 EN61000-
3-3
EN55014-
2

CORRECT DI
SPOSALOFTHI
S PRODUCT

Thi
smar
kingi
ndi
cat
est
hatt
hispr
oductshoul
dnot
bedi
sposedwi
thot
herhousehol
dwast
es
t
hroughoutt
heEU.Topr eventpossi
bleharmtothe
envi
ronmentorhumanhealthfr
om uncontr
oll
ed
wastedi
sposal
,recycl
eitr
esponsibl
ytopromote
t
hesust
ainabl
ereuseofmat
eri
alr
esour
ces.To
ret
urnyouruseddevice,pleaseuset heretur
nand
coll
ecti
onsyst
emsorcont acttheretai
lerwherethe
productwaspurchased.Theycant akethisproduct
f
orenvi
ronment
alsaf
erecycl
i
ng.

17
W0811081
version number 20200109

You might also like