Professional Documents
Culture Documents
CCJ Issue 54 PDF
CCJ Issue 54 PDF
CCJ Issue 54 PDF
www.ccj-online.com
When RENTECH custom engineers a boiler to your exact specs, you get peak
operation and lower emissions. Great custom engineering starts with expert
engineers—and our people are the most resourceful and experienced in the
business. For durability, energy efficiency and clean operation, count on RENTECH’s
custom-engineered solutions. We master every detail to deliver elemental power
for clients worldwide.
WWW.RENTECHBOILERS.COM
2018 meetings: Gas and steam turbines, HRSGs, generators
January 15-16, EPRI TGUG Workshop, Orlando, Fla, June 18-21, Siemens Customer Conference for F, G & H
Disney’s Coronado Springs Resort. Contact: Bill Moore, Technology, Orlando, Fla, Hilton Orlando Buena Vista
bgmoore@epri.com. Palace. Meeting is co-located with the T3K Annual
February 25-March 1, 501F Users Group, Annual Meeting, Conference. Contact: Kelly Lewis, kelly.lewis@siemens.
Orlando, Fla, Hyatt Regency Grand Cypress. Chairman: com.
Russ Snyder, russ.snyder@cleco.com. Conference July 29-August 2, Ovation Users’ Group, 31st Annual
information at http://501f.users-groups.com. Contact: Conference, Pittsburgh, Westin Convention Center
Tammy Faust, tammy@somp.co. Hotel. Register for membership (end users of Ovation and
March 5-7, HRSG Forum with Bob Anderson, Second WDPF systems only) at www.ovationusers.com and follow
Annual Meeting, Houston, Tex, Hyatt Regency Houston. website for details. Contact: Kathleen Garvey, kathleen.
Chairman: Bob Anderson. Details/registration at www. garvey@emerson.com.
HRSGForum.com. Contact: Alan Morris, amorris@ August 27-30, Combined Cycle Users Group (CCUG),
morrismarketinginc.com. 2018 Conference and Discussion Forum, Louisville,
March 18-21, Western Turbine Users Inc, 28th Anniversary Ky, Louisville Marriott Downtown. Meeting is co-located
Meeting, Palm Springs, Calif, Renaissance Hotel/Palm with the Steam Turbine Users Group and Generator
Springs Convention Center. Chairman: Chuck Casey, Users Group. Chairman: Phyllis Gassert, phyllis.gassert@
ccasey@wtui.com. Details/registration at www.wtui.com. talenenergy.com. Details at www.ccusers.org. Contact:
Contact: Charlene Raaker, craaker@wtui.com. Sheila Vashi, sheila.vashi@sv-events.net.
March 20-22, Second International Conference on Film August 27-30, Steam Turbine Users Group (STUG), 2018
Forming Amines and Products, Prague, Czech Republic, Conference and Vendor Fair, Louisville, Ky, Louisville
Hotel NH Prague City. Chairman: Barry Dooley, bdooley@ Marriott Downtown. Meeting is co-located with the
structint.com. Contact: Ladislav Bursik, ladi.bursik@bht- Combined Cycle Users Group and Generator Users
gmbh.com. Group. Vice Chairman: Bert Norfleet, bert.norfleet@dom.
com. Details at www.stusers.org. Contact: Sheila Vashi,
April 8-12, CTOTF 43rd Spring Conference & Trade Show,
sheila.vashi@sv-events.net.
Greenville, SC, Hyatt Regency Greenville. Chairman: Jack
Borsch, john.borsch@ihipower.com. Details/registration at August 27-30, Generator Users Group (GUG), 2018
www.ctotf.org. Contact: Ivy Suter, ivysuter@gmail.com. Conference and Vendor Fair, Louisville, Ky, Louisville
May 7-11, 7F Users Group, 2018 Conference & Vendor Fair, Marriott Downtown. Meeting is co-located with the
Atlanta, Ga, Atlanta Marriott Marquis. Details/registration Combined Cycle Users Group and Steam Turbine Users
at www.powerusers.org. Contact: Sheila Vashi, sheila. Group. Chairman: Kent Smith, kentn.smith@duke-energy.
vashi@sv-events.net. com. Details at www.genusers.org. Contact: Sheila Vashi,
sheila.vashi@sv-events.net.
May 15-17, European HRSG Forum, Fifth Annual
Meeting, Bilbao, Spain, Meliá Hotel. Chairman: Ladislav September 10-13, V Users Group, 2018 Annual
Bursik, ladi.bursik@bht-gmbh.com. Details at http:// Conference, Denver, Colo, Hilton Denver Inverness.
europeanhrsgforum.de. Contact: Kelly Lewis, kelly.lewis@siemens.com.
June TBA, 501D5-D5A Users, 21st Annual Meeting, September 16-20, CTOTF Fall Conference & Trade Show,
decision on venue pending. Chairman: Gabe Fleck, Chandler (Phoenix), Ariz, Sheraton Grand at Wild Horse
gfleck@aeci.org. Registration and other details at Pass. Chairman: Jack Borsch, john.borsch@ihipower.com.
www.501d5-d5ausers.org when available. Details/registration at www.ctotf.org. Contact: Ivy Suter,
ivysuter@gmail.com.
June 11-14, Frame 6 Users Group, Annual Conference
& Vendor Fair, Ponte Vedra Beach, Fla, Marriott October TBA, ACC Users Group, Tenth Annual
Sawgrass Golf Resort & Spa, Co-chairmen: Jeff Gillis, Conference. Details at www.acc-usersgroup.org.
william.j.gillis@exxonmobil.com, and Sam Moots, Chairman: Dr Andrew Howell, andy.howell@xcelenergy.
smoots@coloradoenergy.com. Details/registration at www. com. Registration/sponsorships: Sheila Vashi, sheila.
Frame6UsersGroup.org. Contact: Greg Boland, greg. vashi@sv-events.net.
boland@ceidmc.com. October 7-11, 7EA Users Group, Annual Conference and
June 18-21, T3K Annual Conference, Orlando, Fla, Hilton Exhibition, Garden Grove, Calif, Hyatt Regency. Details/
Orlando Buena Vista Palace. Meeting is co-located registration at http://ge7ea.users-groups.com.
with the Siemens Customer Conference for F, G & H December 4-6, 501G Users Group, Mid-Year Meeting,
Technology. Chairman: Bob Lake, bob.lake@fpl.com. Orlando, Fla, Hyatt Regency Orlando International Airport.
Contact: Elizabeth Moore, elizabeth.moore@siemens.com. Chairman: Steve Bates, steven.bates@dynegy.com.
Actuator acting up
2. Cabinet layout was an important consideration in replacement of GT OEM
control system at this peaking facility; some panels were relocated to make the Steam-turbine bypass systems and
I/O flow more logically valves for combined cycles have been
giving users fits for years. In one Ova-
tion user’s case, it was the actuators on
the HP and IP bypass valves. It would
do little good to show the list provided
of what was wrong with the original
actuator design, because essentially
nothing was right with it. However, in
fairness, it should be noted that this
combined cycle, which came online in
2003, was originally designed for base-
load service, but later began to cycle.
According to the facility reps, “the
3. Steam turbine bypass-valve actuator (left) was replaced with one far sim- valve would go nuts” on a steam-tur-
pler to maintain, not prone to cracking at the weld between plug and stem, bine trip, and for good reason: It has to
easier to tune, and more stable during startups (right) go from closed to 80% open (11.2 in. of
valve stem travel), then throttle as if
ing power supplies and other critical facility, the other a simple-cycle peaker nothing happened, all in two seconds!
items for Ovation systems is expected facility) were acquired from merchant Doing both well is difficult for a valve
to be released “within six months.” owner/operators. Lacking experienced this size, they conceded. They also
Speaking of knotty problems, the personnel in this area, the new owners conceded that the actuator worked
modern simulator has come to the aid essentially put their full trust in Emer- fine the first few years, suggesting
of the age-old mundane problem of son as system supplier and engineer— that cycling may have been the root
inconsistent operator performance at that is, not hiring a separate electrical cause of their issues.
one plant. Personnel there, suffering contractor. All electrical demolition was The original valve was fine, they
from the aging workforce challenge, also left to Emerson. said, but the actuator was poorly
committed to a formal operator train- One of the objectives of the replace- designed. For one thing, it was “full of
ing program anchored by the Ovation ment at the combined-cycle facility O-rings, and other parts and pieces”
embedded simulator, replacing a simu- was to automate the manual power and three derivative boosters (used
lator onsite for eight years but not used. augmentation and water injection NOx with a positioner to increase stroking
Plant representatives reported the control subsystem, dubbed SPRINT™ speed). Also, the rapid stem movement
program led to a 44% reduction in by the turbine vendor. In fact, this repeatedly broke the weld between the
startup and shutdown times. The five was the core of project justification. At plug and stem.
6 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
Five Smart Reasons
why you should specify
Camseal® Ball Valves.
1. Unique, zero-leakage design
2. Top-quality manufacturing
3. Long, reliable life cycle
4. Ease of maintenance and repair
5. Enormous savings in labor,
materials and downtime
Who’s Behind
the folks who made them?
As a contractor to the major HRSG OEMs, Chanute
Your HRSG
Manufacturing has the most experience fabricating
HRSG pressure parts of any company in the U.S.
There is a very good chance some of your HRSG
Pressure Parts?
parts originated at Chanute.
We’re familiar with all OEM designs. And if we
didn’t originally fabricate your HRSG, or if drawings
are not available, we can reverse-engineer your
pressure parts when needed.
Contact us to discuss our recent HRSG
aftermarket installations.
So, bring your replacement pressure part fabrication
back home to the company with over 35 years of
pressure part experience...Chanute.
The plant decided to go with pneu- As described in a document avail- steam hosts and six packaged boilers.
matic actuation because it would avoid able from ICS-CERT online, “it is Now they have to comply as a NERC
oil leaks and fire hazards and the parts a desktop software tool that guides CIPS 6 medium impact facility. “In
would be more readily available than asset owners and operators through a the early days of compliance, we were
for a hydraulic actuator. Emerson step-by-step process to evaluate their patching one workstation every two to
designed a bolt-on actuator (Fig 3), industrial control system and informa- three days.” Plus, they are planning to
leaving the original valve in place, tion technology network security prac- add an 800-MW 2 × 1 combined cycle
with far fewer parts and all the boost- tices.” Available for free, users answer at the site.
ers of the same component. The new questions and the software generates Plant practices reported to the
booster is three to four times the size a report comparing your practices to group included these:
of the original one. recognized government and industry n Create action plans based on vul-
According to these plant reps, the standards and recommendations. nerability assessment results.
valve and actuator “haven’t been In addition to federal standards n Patch monthly to keep current.
touched since” and the weld cracking and recommendations, states are n Physical and electronic access con-
issue has been resolved. Tuning is imposing their own, according to a trol is key.
much easier and more consistent, and consultant on the panel. New Jersey, n Use E-ISAC for threat intelligence.
the control loop is more stable during for example, has mandated cyber- The electricity information sharing
startups. security standards. He noted that and analysis center (E-ISAC) is oper-
costs for complying with mandatory ated by NERC but functionally iso-
Sabers for cyber requirements could be challenging lated from its enforcement arm. It’s a
for power producers in low-price mar- central repository for physical threats,
Protecting against cyber-intrusions kets. That includes most everyone in vulnerabilities, and incidents. Accord-
and keeping the “bad guys” out con- today’s world. ing to information available from the
sumes more and more of the digital An expert from one of the largest program online, the following benefits
control system community’s energy— combined cycles in the country, built are described:
and piles on costs. In addition, like in the early 1990s, explained how his n Identify adversary campaign tac-
environmental restrictions, there are plant went from “25 years of connect- tics, techniques, and procedures and
multiple layers of compliance, stan- ing everything to disconnecting from share specific mitigation actions.
dards, and jurisdictions. the sins of the past.” His plant had n Reverse-engineer malware to bet-
During a cybersecurity panel, a rep- one supervisory control system for the ter understand events and develop
resentative from the US government’s entire plant, because it was designed to predictive capabilities.
Industrial Control System Cyberse- deliver all of its 1640 MW of capacity n Share tactical information to reduce
curity Emergency Response Team to one buyer as a baseload facility. The cyber risk for all participants.
(ICS-CERT, part of DHS) referred the plant comprises 12 gas turbine/HRSG n Cross-benchmark and evaluate with
audience to the C-SET, a cybersecurity trains and three steam turbine/genera- other critical infrastructure sectors.
evaluation tool. tors and, to complicate matters, two ccj
Benefits Varnish on
journal
bearing,
• Increase turbine reliability gas turbine
and availability
I
f your doubt lingers about the for readers to think about it is a shift
direction the electricity industry The changing nature from big iron to the customer’s onsite
is headed, hopefully for your sake
you’re close to retirement. That of electric supply energy infrastructure.
Meet emission
standards with
two catalysts
in one
www.topsoe.com
MDMS
DRMS
Optimization
tool Field-services domain
Audits
to date in a given billing period, their possible.” Different messages resonate upgrades and services in return for
kilowatt-hour usage to date, and other with different customer classes. But demand-response event participa-
information. A Demand Response keeping them retained and engaged tion. This provides more value for
Management System (DRMS), built to requires frequent communication, customers than standard cash rebates
NV Energy’s specifications and run on such as messages sent the way they for DR event incentives.
its IT infrastructure, serves as a cen- want to receive them—email, text, What NV Energy’s transforma-
tral hub to orchestrate the operation voice mail, etc. tion represents for the industry at
and integration of customer, program, large should not be under-estimated.
device, and grid location information. The future is now Designing, constructing, operating,
The information from all this cus- and maintaining a 260-MW generating
tomer data also helps NV Energy bet- None of these challenges appear to unit, and delivering the electricity to
ter monitor and manage the distribu- daunt NV Energy. In fact, it is push- thousands of customers, is quite dif-
tion circuits where these customers ing DR and DER further. Coming ferent from avoiding the need for 260
are located. programs will leverage lessons learned MW by actively controlling assets at
from: the customer premises kilowatt-hour
Monumental learning n A partnership with homebuilder by kilowatt-hour. ccj
Pulte in which 185 LEEDs certified
curve (platinum) homes were built, each
Obviously, there are numerous chal- with 2-kW solar PV on the roof,
lenges to overcome, both in trans- demand responsive thermostats,
forming a “big iron” culture to handle smart meters, and automated intel-
individual customer services, and in ligent agents. An ongoing pilot is
hardware and software development testing the integration and control
(Fig 3). “At one point, we had 18 differ- of 8-kWh Li-ion batteries at 10 cus-
ent types of technologies in the field— tomer sites.
two way switches, one-way thermo- n A statewide pilot that tested new
stats, firmware, and software,” Brown dynamic rate, such as critical peak
observed, “and we had to streamline pricing (CPP) and enhanced time of
the equipment and learn how to inte- use (TOU) pricing to further moti-
grate the software and maintain it.” vate demand response.”
The authoritative
The customer communication chal- A variety of programs are also
information resource
lenge is also serious. NV Energy had available for small, medium, and large
for owner/operators of
to educate its ratepayers on how to use commercial and industrial customers.
gas-turbine-based peaking, cogen,
the smart thermostats. According to One of the more innovative opportu-
and combined-cycle plants.
Kelly Schackmuth, manager of DSM nities for commercial customers are
Subscribe via the Internet, access:
Customer Engagement, “the goal is to agreements in which NV Energy spon-
make it as seamless to the customer as sors investments in energy-efficiency www.ccj-online.com/subscribe
R
eminded Dr R Barry Dooley In boiler water the outer In high-purity water with a pH of 9.0
at the Cycle Chemistry and layer is “washed” away Equal fluxes to 9.5, diffusion is solid-state
FAC Workshop, sponsored by Boiler water
B
Structural Integrity Associ-
ates Inc (SI), June 27 - 28, 2017, in Cin- O2-
cinnati. Cycle chemistry drives many Protective
Fe3O4
of the damage mechanisms that affect Fe2+
availability, reliability, and safety of
conventional fossil and combined-cycle/ A
HRSG plants, the respected chemist/ Tube wall
metallurgist said forcefully. The ongo- Inner layer is compact and
ing battle against operational and Porosity of inner layer is between 8% and 15% adherent, and is stress-free
financial losses was the motivation for 1. Growth of protective magnetite in 680F boiler water is illustrated in tube section
the focused seminar.
“I am not here to make all of you 100 2. Solubility of magnetite is influ-
experts in cycle chemistry,” said Dooley NH3,
enced by temperature, pH, and
who guided the two-day session. “I am ppm pH
0.1 8.75 ammonia concentration. Data here are
here to share experience and insights, 80 based on the work of Sturla in 1973
0.2 8.90
Iron concentration, ppb Fe
The intricacies 0
3. FAC is the leading cause of pres-
sure-part failures in combined-cycle
0 122 212 302 392 482 572 662
Electric power generating facilities are Temperature, F plants
some of the most complex engineering
achievements of our time. It’s impor- ations in fossil and combined cycle/ the Technical Guidance Documents
tant to realize that cycle chemistry is HRSG plants.” (TGDs) available at no cost from the
equally complex, sophisticated, and at With that, he listed the 10 most International Association for the Prop-
times unforgiving. common scenarios: erties of Water and Steam (IAPWS)
Every operating minute of every 1. Presence of corrosion products. through the organization’s website at
day adds to the wealth of global cycle- 2. Drum carryover. www.iapws.org.
chemistry experience being analyzed 3. Fossil waterwall/HRSG evaporator “Very few powerplants throughout
by Dooley and the SI team. deposition. the world,” explained Dooley, “meet
4. Improper chemical cleaning. even the minimum requirements.” Lack
Bad habits (poor 5. Contaminant ingress. of proper instrumentation tied with
6. Air in-leakage. corrosion products as the leading (and
common practices) 7. Lack of online alarmed instrumen- preventable) damage-causing condition.
Participants examined what Dooley tation. Summing up the discussion, Dooley
and his colleagues label repeat cycle- 8. Failure to challenge plant status emphasized: “We should be able to do
chemistry situations (RCCS)—circum- quo. something about this, and we can!”
stances that trigger damage. “A focus 9. Inadequate shutdown protection.
on RCCS is perhaps the industry’s 10. Lack of action plans (or simply, Oxides and growth
most powerful tool,” he emphasized. lack of action).
Dooley added: “Chemistry-influ- Each was discussed in detail. It was important to review oxides and
enced failure and damage can always Consider No. 7, for example, proper their growth (Fig 1) by discussing
be related back to these repeat situ- instrumentation is clearly outlined in feedwater, boiler/evaporator water,
16 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
FORUM
Re O Su
gi pe m m
Th
s t ns e
is
ra
tio
WITH BOB ANDERSON
n
March 5-7
r!
Hyatt Regency Houston “We offer carefully chosen
presentations on topics
designed to help owners/
operators and maintenance
professionals be more
successful.”
– Bob Anderson
40
of magnetite dissolution, were referenced.
iron oxide solubility, and 30
corrosion-product transport
Think about chemical cleaning
Good tubes don’t fail
followed. 20 Start of corrosion products within
Copper alloys and their porous scales “Chemistry can be optimized
impact on the HP turbine 10 to reduce damage inflicted by
were included, along with Optimum HRSG chemistry and FAC,” continued Dooley, as well
meeting the Rule of 2 and 5
a review of supercritical 0 as that caused by the following
units. 1000 1200 1400 1600 1800 2000 2200 2400 damage mechanisms:
Pressure, psig n Under-deposit corrosion
FAC—a complex 5. Deposition map for HP evapora- (UDC).
n Hydrogen damage (remains prolific
adversary tors was developed by IAPWS and
today).
appears in the organization’s 2016
Significant time was spent on flow- Technical Guidance Document, n Corrosion fatigue.
accelerated corrosion (FAC), a complex “HRSG HP Evaporator Sampling for n Thermal fatigue.
yet comprehensible phenomenon in Internal Deposit Identification and n Pitting.
today’s power systems. FAC is the Determining the Need to Chemical As Dooley clearly stated, in all
leading cause of failures in combined- Clean,” downloadable at no cost from cases you must identify the damage
cycle plants. www.iapws.org and understand the root cause. “You
These discussions centered on: never have a good tube fail,” he said.
n Single- and two-phase FAC. The key is to understand the damage
n Mechanisms and parameters (very ter up to about 535F to 572F under mechanisms.
important; solutions are different). low-oxygen (reducing) conditions. Hydrogen damage, based on con-
n Alleviation through cycle chemistry n With laminar flow, this is protec- taminants, continues to be a major
and materials. tive and its growth is balanced by powerplant concern. Damage examples
Dooley offered specific examples of its dissolution. were traced throughout the steam
both single- and two-phase FAC in fos- n Below 302F the layer can be very system, followed by chemical clean-
sil and combined cycle/HRSG plants. thin, and is controlled by local cycle ing criteria. Another important point:
The principal point: FAC continues chemistries. Cycle chemistry influences 70% of all
to occur in more than 70% of fossil n With turbulent conditions (because HRSG tube failures.
plants, and represents nearly half of of local geometries), the dissolved Various rules of thumb also were
all tube failures in both horizontal- and ferrous ions are removed more rap- discussed, including the Rule of 2 and
vertical-gas-path HRSGs. idly. 5, and an IAPWS-generated graphic on
Fundamental conditions for FAC n This faster removal equates to a deposition in HP evaporators (Fig 5).
18 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
The Rule of 2 and 5 applies to optimum
total iron levels in the condensate/feed-
water (<2 ppm) and in the evaporator/
steam drum (<5 ppm).
A few conclusions about under-
deposit corrosion: Power Plant Maintenance Tools
1. Visual examination of a tube is gen-
erally not sufficient to distinguish
among hydrogen damage, caustic
gouging, and acid phosphate cor-
rosion.
2. Metallography and deposit analysis
are necessary to determine the cor-
rect mechanism.
3. Once the mechanism is identified,
Tube Expansion Tube Beveling
a root cause analysis is needed to
eliminate future damage.
4. Identifying RCCS is key to avoiding
UDC mechanisms.
Discovery
Stressing again the need to clearly
identify and define the damage mech-
anisms, Dooley emphasized the need
Fin Removal Panel Cutting
to link visual inspection with plant
chemistry. “Include the chemists,” he Fast, Accurate, Easy Operation
said. A proper, complete inspection Available for Sale or Rental
program should also involve someone
at the VP Operations level to give it www.escotool.com
proper weight. “Develop a corporate 800-343-6926 | 508-429-4441
mandate,” he recommended. A Unit of ESCO Technologies, Inc.
And identify the vulnerable sys- World Leader in Boiler Maintenance Tools
tems:
n Look at all susceptible systems that
contain the following:
● Carbon steel.
● Flowing water or wet steam.
n Consider system design and operat-
ing features.
● P&IDs, heat-balance diagrams.
● HRSG circuit design and thermal
performance.
n Review water chemistry.
● Current and past practices and
guidance.
● Parameter analysis compared to
IAPWS
● Instrumentation compared to
IAPWS
n Document the review.
“Look closely at all the interfacial
areas of fluid and materials,” he said.
Empowering the Next Generation of
Bringing it home
Power Plant Operators
Near the end of Day Two, partici-
pants were asked some specific tech- OSUIT students engage in a two-year degree plan that includes a paid
nical questions. The questions were internship & significant progress towards an initial Plant Operator
designed for thought, for ideas, for qualification.
discussion, and for analysis. All were
verbatim inquiries from operating
plant personnel asked of Dooley and Visit osuit.edu/powerplant for the top ten reasons
his colleagues. to pursue your degree at OSUIT.
Participants walked through the
thought path for each, adding focus
and meaning to the two days of dis-
cussions.
This was real-world stuff to carry Oklahoma’s Only University of APPLIED Technology
home to real-life jobs. ccj
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 19
COMBINED CYCLE USERS GROUP
Visit siemens.com/power-generation-services
COMBINED CYCLE USERS GROUP
2. Transformers fail regularly, an insurer told users attend- 3. A death was attributed to an explosion suffered during
ing the CCUG Conference the unloading of hydrogen
while combined cycles are forced into 2013 as an example. The document
greater cycling and dispatch, escalat- describes an explosion that occurred
ing maintenance costs. during the unloading of hydrogen for
With economic home and building generator cooling at a large powerplant
storage on the cusp of commercial in the Southeast and the 17 serious
expansion, competitive kilowatt-hours safety violations the owner/opera-
from rooftop solar PV, and so-called tor was cited for (Fig 3). While the
smart home and building design and resulting proposed fines totaled over
devices (for example, smart thermo- $100,000, the scope of the violations
stats), Makansi posited the emerging screams negligence.
world of the “YouTility,” where behind- To underscore the need for broad
the-meter electric producing and con- programs like systems knowledge and
suming infrastructure challenges the management of change, he recounted
“size of wire” required from the grid to the failure of DC power supplies (Fig
every building, and perhaps disinter- 4. Batteries demand your attention. 4) at a plant which affected the AC side
mediates the utility itself. A thermal runaway can occur when a of the electrical system and caused a
Makansi urges utilities to consider battery is being charged and the heat loss of lubrication on coast down, which
such infrastructure as simply an generated exceeds the rate at which went on to impact the entire turbine.
extension of the grid itself, especially it can be dissipated through the bat- “Check your batteries!” he urged. This
because of the two-way interface, and tery case to the environment kind of failure apparently occurs at
apply the traditional rate-of-return least once a year, with an average
infrastructure business model which equipment loss of $20-million.
has worked well over the last century. He labeled such failures routine
events with severe consequences, as
Risk management
contrasted to routine events, including
transformer failures and, as another
example, clashing damage in Frame 7
A representative from a major power- compressors (and also in some Frame
plant insurance firm delivered some 5 and 6 units) attributed in part to
foreboding words and statistics at the vane lock-up in carbon-steel vane car-
CCUG’s 2017 Annual Conference. In riers (Fig 5).
particular, he stated that 40% of trans- 5. Clashing damage to the trailing Some of his other points and sug-
former faults occur regardless of any edges of R1 rotor blades can range gestions include these:
prevention or inspection techniques. from rub marks shown at left to torn n OEMs are known to have installed
Transformers, he said, fail regularly and displaced metal (right) parts which were condemned.
(Fig 2). He added that 70% of all losses n Greater oversight is required of
are equipment breakdown. valuable guidance on fire protection third-party independent component
He further noted that process and prevention and on maintaining suppliers.
safety culture in the US “lags behind the integrity of lubrication systems. n Identify single points of failure and
Europe and Australia,” and urged the Note that Power Users is the umbrella address them.
audience to download his company’s organization for managing and coordi-
A death results
complete without debating how digital ested in working with us,” he told
technology is changing the O&M game. attendees at the CCUG Conference.
when safety
Putting the control-room informa- After implementing the obvious
tion and indicators on remote digital steps of tightening up maintenance,
devices was mentioned. In connection
with that, one GE leader referred to
tuning up the system, and upgrading
the NH3 curve, the key to the program procedures are
a plant in California running at 10%
capacity factor that has gone down to
was to focus on the many points in the
startup sequence when you wait—such
ignored
a single operator at night. as warmup, breaker synch, SCR com-
Cybersecurity was addressed by ing up to temperature, combustion Although a presentation on the post-
a representative of the regional office entering the “zone,” and water injec- mortem analysis of an incident result-
of the FBI. He observed that physical tion coming on. ing in a worker death is somber, it’s
access is still the key to many security The specific steps proved to be also a learning event and reminder
problems. Several pearls of wisdom: (Fig 6): that safety must always be reinforced,
n Wall off anything that cannot be n Reduce the SCR/NH 3 injection even if, as in this case, you’ve per-
patched from the Internet. interlock temperature. formed a task a hundred times before.
n Don’t trust Microsoft patches. n Lower the SCR temperature NH3 Users were reminded of this at the
n If you have Kaspersky anti-virus block interlock. CCUG Conference.
software, get rid of it. Kaspersky n Lower the NH3 injection heater In the case described (at a hydro
software has gotten caught up in the temperature interlock. facility), the task was to clean a de-
nation’s current love of all things n Alter the NH 3 motive heating energized 13.8-kV bus. A veteran
Russian. scheme. worker, who had performed this task
Another FBI agent discussed the n Add a megawatt-based feedforward 26 times before, was left alone as his
ideology of Islamic terrorism, though capability to the normal NOx-ppm team member left to retrieve an item
it was unclear whether anything was feedback loop and fuel feedforward they had forgotten for the job. He
directly applicable to US powerplants. process control loops. returned to find the veteran co-worker
Both agents suggested that plants As one example of the reasoning, “energized” and lying on the ground.
consider a visit from the FBI/Dept of the system had been programmed Inexplicably, what happened was
Homeland Security (DHS), through the to wait for the SCR catalyst to reach that the two of them had noticed a flat
Arizona Cyber Threat Response Alli- 550F, before starting NH3 injection. washer on the floor. While the vet-
ance, to walk down the site and provide Discussion with the supplier sug- eran was alone, he wanted to “fix the
an evaluation and recommendations. gested 450F was acceptable. However, problem” and put the washer where
ammonia salts vaporize at 310F, so it needed to be. In doing so, accord-
Before After
“Where others had failed before, Precision Iceblast succeeded” – El Dorado Energy
“I recommend your services to anyone needing this type of work”– Millennium Power
“Contractors that we have used in the past to ice-blast our HRSG have not met our
satisfaction to say the least. Your crew cleaned the tubes better than the other contrac-
tors have done before” – Calpine
“I commend them on their ability, attitude, and professional manner in which they
conduct their business”– Contact Energy
“Your crew was very professional and knowledgeable about the cleaning process and
the reason for cleaning HRSG tubes”– Power South
their experiences
these components often. to the tax burden. Another non-utility
During the second discussion combined cycle shares parts with other
session later in the program, new spar- owner/operators in the area, primar-
Two of the more insightful open-discus- ing and inventory programs sucked up ily a competing utility. A third user
sion sessions at the CCUG Conference a good portion of the oxygen. One util- cautioned that equipment sourced
had plant representatives, somewhat ity representative spoke about a formal overseas requires that you “document
extemporaneously, tell the conference critical-parts risk matrix—including the hell out of stuff.” Just because you
leaders (all veteran plant managers) cost, location, turnaround times, poten- specced out an in-kind replacement
what they needed help with and what tial suppliers, etc—conducted across doesn’t mean you’re going to get it.
problems they might solve, or at least their combined-cycle fleet. This led The discussion on spares necked
address, during the meeting. to increased inventory, especially for down to thermocouples. One plant rep-
The following are some of the topics/ long-lead time critical spares at single- resentative said that often one fails, then
concerns on the minds of users report- point-of-failure locations. you put the installed spare in service,
ed out in the first discussion session: However, increasing spares adds and forget about it. Now the practice has
n We’re seeing components fail for
the first time; thermowells are an
example. What are some of the
other “one-offs” others are seeing,
things not expected?
n The way we operate is changing.
We’re now offline during the peak of
the day. We have six-hour minimum
runs, instead of 12. We had a con-
trol valve split in half. Generally,
we’re experiencing more cycling and
increased maintenance.
n Daily cycling is leading to cracking
of steam piping (Fig 7), not leaks,
but weld failures, valve seats crack- 9. Cathodic protection system test station, post-mounted and easily seen, is
ing, etc. Strainer baskets are not installed near where the natural-gas line enters. System is of the non-powered
catching foreign material going to (sacrificial) type
26 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
MAXIMUM RELIABILITY
Water cooling technology to maximize capacity payment opportunities
by providing reliable back up liquid fuel system operation
Water Cooled 3-Way Purge Valves Water Cooled Liquid Fuel Check Valves
JASC water cooled 3-way purge valve is a bolt-in Water cooled fuel controls utilized to negate the impact
replacement for your standard 3-way purge valve. of coke formation and maintain ANSI class 6 sealing in the
This design coupled with heat sink clamps keep fuel checked direction.
lines cool during extended periods of gas operation
and will significantly improve both valve and fuel
system reliability.
ALL NEW
WWW.JASC-CONTROLS.COM
Tel: +1 602.438.4400 Fax: +1 602.438.4420
sales@jasc-controls.com
Mark your calendar
Combined Cycle Users Group
Eighth Annual Conference
and Discussion Forum
August 27-30, 2018
Louisville Marriott Downtown, Louisville, Ky
Steering Committee
Chair: Phyllis Gassert, Talen Energy
Vice chair: Brian Fretwell, Calpine Corp
Past Chair: Dr Robert Mayfield, Tenaska Inc
John Baker, Clearwater Cogeneration Plant, Riverside Public Utilities
Jimmy Daghlian, NV Energy
Robert Marsh, Puget Sound Energy
Steve Royall, PG&E
Individual
agement, operation, and/or maintenance of generating
facilities powered by gas and/or steam turbines.
MD&A experts offer a unique, patented repair process that eliminates 7FH2 spring migration and restores
your generator to full operation.
During normal field operation, the springs under the full length amortisseur can migrate axially within the
slot, which can lead to blockage of the radial ventilation passages.
This blockage results in reduced hydrogen gas cooling flow, which can lead to thermal instabilities with the
rotor. The resulting excessive rotor vibration may eventually produce a forced outage.
Our innovative solutions keep your generator working smoothly.
Harold Parker
Director of Engineering, HPC Tech-
nical Services
Hal Parker got his start in power
generation like so many others in the
business: As a GE field engineer and
startup engineer.
Premiere He migrated from
road assignments
Turbine to the company’s
Field Engineer-
Generator ing Development
Mechanic analysis and balancing. He joined
Southern Company in mid-1976 and
Center in Sche-
nectady where he
Training spent the next 34 years with the
utility as a steam-turbine specialist.
authored many
of GE’s advanced
Program Among Baker’s many accomplishments training programs.
was his work in the development of Since leaving GE in 1983, Parker
in the Southern’s strategy for steam-turbine has focused on providing training ser-
Southeast! reliability. He was an active member
of the Vibration Institute (national
vices to power generators, although he
has taken field assignments in plant
organization and Georgia chapter) for startups, outage technical direction,
100% placement rate years and represented his company on
many EPRI projects.
and controls-related troubleshooting.
Parker owned and operated Sche-
Baker launched the consulting firm nectady Learning Systems from 1983
Enrolling now for that bears his name in mid-2010 after
retiring from Southern and he remains
to 1989 and served as turbine/genera-
tor manager for General Physics from
January 2016 active in the industry solving steamer
problems for customers. Colleagues
1989 to 1992 before forming HPC
Technical Services.
Fort Myers
in powerplant oper- commercial aspects. Parsons’ knowl-
ations—includ- edge and respect for rotating equip-
ing all aspects of ment is said to be on par with the best
(239) 334-4544
and Kyrene Generating Stations. STUG’s 2018 Individu-
Hughes is a dedicated leader, al Achievement Award,
always ready to share his knowledge please complete the nom-
and experience on safe, reliable O&M ination form (access by
www.FortMyersTech.edu of generating assets. He has been
involved with SRP’s plant appren-
ticeship training program since its
scanning the QR code with your smart-
phone or tablet) and forward it to the
steering committee for consideration.
32 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
Total Support – Total Reliability
Engineering expertise and years of experience in the field
make us a valuable part of your day to day operations.
Multistage pumps are manufactured by a number of companies for high pressure
medium flow applications and are critical to combined cycle plant operations.
These machines are critical to operations but have presented great challenges related
to overall reliability. They are often incorrectly installed and the plants may not have
the specialist resources available to diagnose problems that stem from multiple areas.
Engineering, manufacturing, installation and operation are all critical to proper performance.
Hydro’s study of this type of equipment and the issues encountered, has resulted in the
development of engineering solutions and processes to ensure successful repair and installation
of multistage pumps. Our engineers and technical staff have extensive experience with a broad
range of pump equipment. This diverse engineering expertise, and use of the latest manufacturing
and design technologies are why so many combined cycle plants rely on Hydro. We invite you to rely
on us too.
800.223.7867 l hydroinc.com
ATLANTA l BEAUMONT l CHICAGO l DEER PARK l DENVER l HOUSTON l LOS ANGELES l PHILADELPHIA
AUSTRALIA l CANADA l ENGLAND l FRANCE l INDIA l KOREA l UNITED ARAB EMIRATES l VIETNAM
PERFORMANCE IMPROVEMENT
Human performance
events become opportunities
at NV Energy
A
s an integral part of its
operational-excellence core
principle, NV Energy rec-
ognizes that human errors
or gaps in its processes can directly,
sometimes significantly, impact
safety as well as operational per-
formance, reliability, and assets.
Reducing and eliminating these
errors and shortcomings is the
essence of its ongoing Human Perfor-
mance Improvement (HPI) initiative.
The goal is to transform operational
groups into learning organizations
where discovery, investigation, and
problem-solving become collaborative
at every level. Widespread involvement 1. NV Energy reminds employees and contractors of the base perspective on events
and a culture of trust are necessary to
truly expose the organizational weak-
nesses that lead to human errors. This 2. Reporting. indirectly causes a significant event
requires firm leadership alignment 3. Root-cause analysis. triggers the tracking process within the
from top to bottom so that when mis- 4. Communications. HPI system,” says Steve Page, project
takes happen they are used as learning 5. Proactive error-prevention tools. director for NV Energy’s generation
opportunities. When something unexpected (think organization. The tracking system calls
Perspective. The first distinc- unwanted) happens, the immediate for clear identification of the immedi-
tion is to separate human activity task is to trace its origin—thoroughly ate direct cause or causes. To help,
from equipment operation and stress. and objectively. examples within a web-based system
Equipment malfunction or failure are listed for both behaviors and sub-
reportedly accounts for only 20% of a Event tracking and standard and at-risk conditions.
plant’s reliability loss, human involve- Significant events fall into one of
ment (human error) the remainder reporting the three following categories:
(Fig 1). “Any human action which directly or 1. Safety. Any OSHA recordable inci-
But the latter goes far beyond errors dent.
by individuals. The human-factor cat- 2. Environmental. Notice of violation
egory includes collective weaknesses, NATO/ICAO phonetic or spill reportable to an outside
norms and traditions, management alphabet agency.
styles and systems, almost anything 3. Production. A unit forced outage or
non-equipment. In fact, most of the A Alpha N November capacity de-rate greater than 20%.
human element (seven times out of B Bravo O Oscar The examples are further defined
10) can be classified as organizational C Charlie P Papa as either behaviors or conditions. Acts/
weaknesses—including such strong D Delta Q Quebec practices/behaviors include such things
influences as ownership or manage- E Echo R Romeo as failure to warn, operating without
ment changes. authority, deviation from standard
In that context, a concentration F Foxtrot S Sierra procedure/practice, etc. Substandard/
on HPI makes a lot of company-wide G Golf T Tango at-risk conditions include inadequate
sense, and should not be taken person- H Hotel U Uniform warning system, defective protective
ally. It only makes the team better. I India V Victor devices (or none), substandard tools
Many organizations have launched J Juliet W Whiskey or equipment, etc.
initiatives to address these factors and Each incident is reviewed by local
occurrences. NV Energy’s HPI program K Kilo X X-ray leaders along with corporate leader-
is robust and underpinned by five fun- L Lima Y Yankee ship and support personnel. The events
damental platforms. They are: M Mike Z Zulu are mined for learnings to be shared
1. Event tracking. throughout the company.
34 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
ONE SOURCE FOR ALL YOUR POWER
PLANT CLEANING REQUIREMENTS
Tube Bundles
Injection Grid
Steam Turbine
Gas Turbine
Two-minute drill
LOOK FOR ERROR TRAPS
3. The two-minute drill is a conscious pause to gain situational awareness about task demands, individual capabilities,
the work environment, and natural biases which may divert from accomplishing a task successfully
36 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
PERFORMANCE IMPROVEMENT
acknowledge steps that might not be with components with similar names. the task or environment is not playing
applicable. Signatures, initials, dates, The NATO/ICAO (International Civil out as intended, it is imperative to stop
and times also could be required. Place Aviation Organization) phonetic alpha- and re-stabilize the situation. “Never
keeping is required for all written pro- bet is the most common (table). An proceed in the face of uncertainty,”
cedures, and during all unit startups important point: This is used during says Page. ccj
and shutdowns. verbal, not written, communication.
Three-part communication is a Written letters are visually distinct.
technique that ensures messages are The two-minute drill simply
understood correctly before any action means taking the time to evaluate a
is taken. This is used every time a job site for safety and error concerns.
directive is given. First, the sender Typical questions to consider are
identifies the receiver by name and permission requirements, hazards in
provides the initial message. Then, the the area (above, below, and ambient),
receiver acknowledges receipt by either and protective equipment require-
paraphrasing or repeating back the ments—among others. NV Energy
directive verbatim. Paraphrasing helps emphasizes use of the two-minute
both parties verify full understanding. drill on first entry at a location, as
Third, the sender acknowledges that well as after an interruption of any
the response was correct. Actions can type or length.
then take place. Procedure and work-package writ-
Keep in mind that the third part ers often do not have direct access to
(sender acknowledgement) is often the witness all site conditions, and are not
weakest link in this chain. generally present on the day the work
Some basic rules are important, is implemented. Thus, the two-minute
such as avoiding the use of slang or drill gains critical importance. Work
regional words, and giving multiple conditions can vary from those in the
instructions. At NV Energy, this tech- procedures, and even from the daily
nique is required when: pre-job briefing.
n Communicating operational infor- And if a person is experiencing a
mation or directing operational gut feel about something, this is the
tasks. time to raise it. “Never think that a
n Communicators are in high-noise job is easy, simple, or routine,” states
areas. Page. This is the time to look for what
n Processes or procedures are critical. NV Energy identifies as common error
n There is a risk of miscommunica- traps—such as distractions, inaccurate The authoritative
tion. assumptions, time pressure, unfa- information resource for
n There is use of radios, telephones,
or other communications devices.
miliarity, interruptions, or personal
stress (Fig 3).
owner/operators of
The phonetic alphabet is a com- Stop is perhaps the most critical gas-turbine-based
mon tool to ensure communications tool, allowing pause in task perfor- peaking, cogen, and
are clear, concise, and accurate. This
eliminates confusion when dealing
mance to verify that all key details
of the task have been addressed and
combined-cycle plants.
with letters that sound alike (b,t,p,v,d), understood. The pause in action can be Subscribe via the Internet, access:
when an acronym could be confused initiated by anyone. The cornerstone www.ccj-online.com/subscribe/
with another acronym, or when dealing rule is to fail conservatively, meaning if
38 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
7EA USERS GROUP
TILs critical to
Doug Reves, outage coordinator, sor shims and corrective actions
Arkansas Electric Co-op Corp available to mitigate the risks of
7EA inspection Randall Rieder, mechanical engi-
neer, ATCO Power
migrating shims.
n 1744, “S17, EGV1, and EGV2
success Mike Vonallmen, maintenance
supervisor, Clarksdale Public
Stator-Ring Rail and CDC Hook
Fit Wear Inspection,” provides
The editors corralled Mike Hoogsteden, Utilities guidance on the repair of dovetail
director of field services for Advanced Lane Watson, account engineer, wear and suggests hardware and
Turbine Support LLC, which inspects FM Global software enhancements available to
scores of 7FAs annually, to learn how mitigate the potential risk caused
users can make their outages more annually), “What We Are Seeing in the by operating conditions that pro-
productive and minimize the possibil- 7EA Fleet During Our Inspections.” mote such wear.
ity of missing something that could A good place to start, he said, is to There are many more TILs that
contribute to a forced outage. He and review the OEM’s Technical Informa- demand your attention, to be sure.
his colleagues have opened every 7EA tion Letters (TILs) pertaining to the They include the following:
User Group meeting for the last several 7EA, take notes, and bring your ques- n 1090-2R1, “Compressor R17 Blade
years with their presentation (updated tions to the next user-group meeting. Movement.”
40 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
Young & Franklin’s Return on Investment calculator can help you find your savings,
contact a specialist today for more information.
Think about leaks. Varnish. Servo maintenance. Lube oil system cleaning. Filter replacement.
Annual device calibrations. Motor & pump maintenance. Unscheduled shutdowns. And more leaks.
Young & Franklin Inc (YF)’s suite of EMA actuators are designed to be durable, reliable, and virtually maintenance-free for up
to 96,000 hours, giving typical users a quick return on their investment. With an installed base of products running on more
than 15,000 turbines, YF has built a reputation based on technical expertise and product excellence.
@
+1.315.457.3110
TURBınE ınSULATıOn AT ıTS FınEST
Bremco, Inc.
Expert Service Since 1976
Claremont, New Hampshire | tel 603-863-9071
sales@bremco.com | www.bremco.com
10. Rotor-blade radial tip crack like that at left can be removed in-situ (first and second stages) in one shift as shown
in the center photo. Allowing the crack to propagate can lead to a tip liberation like that at right, with consequent down-
stream damage
44 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
Cust-O-Fab Specialty Services offers
a convenient single source contact
for construction and fabrication. We
provide cost-effective retrofit solutions
for your power generation project.
Safety, Quality,
Schedule & Value. Look to Cust-O-Fab for the experience, expertise and
dedication to provide a safe, well planned and efficient
project… every time.
» Exhaust Plenum » Inlet Ductwork
Upgrades & Silencers
» Exhaust » Speciality
Ductwork & Welding
Silencers Services
» Inlet Filterhouse » Boiler
& Cooling Upgrades
Systems and Repair
918.245.6685 • www.custofab.com
cracked rotor blades and about half as inspection. Shims protruding from the halves of the case to retain the new
many tip liberations. case by less than one-quarter of an vane segments. The inserts are held
inch should be monitored regularly. in place with setscrews. The user
TIL 1562 When the shim protrudes into the flow describing the procedure cautioned
stream one-quarter of an inch or more against considering it a permanent
TIL 1562, issued January 2007, is it should be removed or ground off. fix because a root cause analysis had
likely the most familiar of the adviso- not been completed.
ries in this group of five because it is TIL 1744 Mike Hoogsteden can be reached at
more than a decade old and shim lib-
eration has been discussed frequently TIL 1744, issued September 2010, mhoogsteden@advancedturbinesup-
in user-group meetings and in CCJ. said 7EAs operating at part load when port.com.
Fig 11 provides a quick review. The ambient temperature is less than 40F
left-hand drawing is of a typical shim,
center photo shows a shim protrud-
are at risk for major damage caused
by the lifting of 17th-stage vane seg-
User presentations
ing from the compressor, right-hand ments. As the segments lift up they Presentations by owner/operators are
picture is of a shim blended flush to damage the hook fits and turn into highly regarded at user-group meet-
the case. the rotating blades. ings. The first-hand experience detail-
Hoogsteden recommends that users A non-OEM repair procedure ing how a particular job was conducted,
develop a shim map for their compres- described at a user group meeting what worked/what didn’t, lessons
sors to identify locations where shims attended by the editors involved learned, etc, can be invaluable to some-
might have been installed, then audit milling of the damaged slot to accom- one considering a similar project. Plus,
those locations for shims remaining. modate 18-in. inserts. They were there’s the opportunity to ask questions
The map should be updated after every installed in the upper and lower and get straight-forward answers.
Retention hooks
11. Shims are supplied with retention hooks as shown at the left. When hooks
are lost to wear and tear, shims migrate out of their slots (center), and must be
removed or ground off (right photo) to prevent liberation and downstream damage
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 45
Advanced surface coatings for turbomachinery
More high-performance coatings, more experience, more innovation, more options and more support
Seven user presentations from is applicable to all hydrogen-cooled, hours. Longest demonstrated run
the 2016 7EA Users Group confer- medium-size generators manufactured on IN-738 buckets with eight cool-
ence, profiled below, are accessible between July 1988 and September ing holes was 100,000 fired hours.
to registered users on the organiza- 2002. Its purpose is to remind users n Third stage. U-500, cutter teeth.
tion’s website. The titles reflect the to inspect the tightness of the stator Typically repair at HGP or major
diversity of material shared at a end-winding support hardware for and replace at about 135,000 fired
typical 7EA meeting—including HV loose, missing, and non-locking fas- hours. Longest demonstrated run
electrical, generators, gas turbines, teners. Photos show damage done by was about 140,000 fired hours.
valves, etc. liberated fasteners and how fasteners Nozzles:
n Bus replacement. can be fixed in place with epoxy to n First stage. FSX-414 with full
n TIL 1398 inspection of stator-end mitigate the issue. MCrAlY and TBC coating. Repair
winding axial support system hard- A table included in TIL 1398-2 at HGP and replace when no lon-
ware. identifies machines susceptible to loose ger cost-effective to repair. Longest
n Hot-gas-path component life. fasteners (such as the GE 324 steam demonstrated run expected at next
n 7EA maintenance strategies. turbine/generator, 9A4, and 7A6), gives outage would be 140,000 fired
n Gas valve upgrade. part numbers of interest, etc. hours. At the time of the presen-
n 7EA compressor issues. HGP component life reflects the tation a set of nozzles with about
n Wrapper leak mitigation. experience of three 7EAs, each having 130,000 fired hours was at a shop
The bus-replacement presenta- a nominal 20 years of cogeneration ser- for repair.
tion describes in photographic detail vice. The baseload units had operated n Second stage. GTD-222 with MCr
the retrofit of 15-kV/4000-amp cir- roughly 165,000 fired hours and had AlY coating. Repair at HGP; replace
cular non-segregated (non-seg) bus. fewer than 200 starts, respectively. when no longer cost-effective to
More than seven-dozen images of the Inspection schedule was combustion repair. Longest demonstrated run
components and their assembly and every other year, HGP every four expected at next outage would be
installation, foundations, plus detail years, and major every eight years. about 162,000 fired hours.
drawings, walk you through the proj- Buckets: n Third stage. GTD-222. Repair at
ect quickly. A companion presenta- n First stage. DS GTD-111, 12 cooling major; may replace at 200,000
tion, made by Bruce Hack of Crown holes, GT 33 coating and TBC. Typi- fired hours or when no longer cost-
Electric Engineering & Manufacturing cally repair at HGP and replace at effective to repair. Original sets of
LLC, covering circular non-seg bus, about 100,000 fired hours. Longest nozzles still in machines with about
switchgear and circuit breakers, also demonstrated run was 105,000 fired 165,000 fired hours of service and
is posted on the 7EA Users’ website. hours. two repair cycles.
(Backgrounder: “High-voltage elec- n Second stage. IN-738 and GTD-741, Shroud blocks:
trical emerges as a top interest area 10 cooling holes, scallop shroud, cut- n First stage. HR-120 with cloth seals.
among GT users,” CCJ 3Q/2016, p 70.) ter teeth. Typically repair at HGP or n Second and third stages. Honey-
TIL 1398-2, issued in March 2003, major and replace at 100,000 fired comb.
46 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
MORE POWER TO YOU
With over a century of filtration expertise and the first to
manufacture air intake and pulse system components for
gas turbines, Donaldson® is well-equipped to put more
power in your hands.
donaldson.com
866.569.7256 CONTACT US
GTSgroup@donaldson.com WHEN YOU NEED FILTERS,
PARTS OR SERVICE
© 2017 Donaldson Company, Inc.
7EA maintenance strategies. an indication is found, the engineering it offer a method for determining
This presentation, rated “must review” department recommends confirma- the magnitude of indications.
by the editors, offers valuable insights tion with FPI (fluorescent penetrant n The speaker’s company has quali-
based on the extensive experience of inspection). fied EC as its preferred method of
both the user and his company. The For more on TIL 1884 and what S1 inspection.
power producer has 51 7EA peaking others think about the use of dye pen- n The power producer also evaluated
units (no baseload) installed at six sta- etrant to achieve its goals, see the sec- its 7EA fleet based on S1 inspection
tions; 39% of the engines have Type tion above focusing on 7EA compressor results compared to operational
403cb stainless steel S1 airfoils, the inspection. profile and parameters, finding
remainder GTD 450. The strategies Continuing, the speaker said his no correlation to predict S1 crack
discussed had to do with S1 failure company embraces 100% borescope initiation and when an S1 failure
mitigation, post-outage performance inspection of the R1/S1 area for clash- would occur.
loss, and rotor end-of-life. ing and of recording clashing damage, Post-outage performance loss. A
Regarding S1, the speaker first if found, with photos and measure- relatively common complaint of owner/
reviewed inspection options, then ments. Mapping of clashed stators operators presenting on their recent
discussed the company’s original also is done. major inspection experience is the
failure-mitigation program and why Here’s how the speaker summarized deterioration of performance following
some tweaking was required. He the company’s S1 failure mitigation restart. The editors have heard this at
then explained the updated plan and observations and efforts: several user-group meetings with no
reviewed ongoing development of yet n Corrosion of carbon-steel ring seg- particular OEM or third-party vendor
another mitigation plan (referred to ments reduces vane damping and singled out.
as the “alternative” plan) based on increases stator stresses if a rotat- The 7EA speaker discussed per-
the efforts of EPRI and its members. ing stall is experienced during formance loss after a combustion
TIL 1884. The speaker addressed startup and/or shutdown. inspection (rare) and HGP. The typical
TIL 1884 first, noting that the OEM n At the time of the presentation, S1 finding: Pre-outage NOx margin was
recommends dye penetrant for NDE. failures associated with GTD 450 different that post-outage. Engines
The user’s engineering department were airfoil tip liberations; with were tuned to lower firing tempera-
does not agree, believing greater acces- Type 403cb stainless steel, root tures to assure environmental com-
sibility is needed for a proper dye-pen- liberations. The latter failures can pliance. The result was a 3- to 5-MW
etrant inspection, excessive application occur with no clashing. decrease in output. The user’s compa-
of dye-penetrant chemicals is required, n TIL 1884 recommends dye-pen- ny, the OEM, and various third parties
and results are inconsistent. It recom- etrant inspections only for units believe fuel/air variation explains the
mended eddy current (EC), finding it is experiencing clashing. It does not performance issues.
easier to implement, results have less address units with 403cb airfoils The owner has been flow-testing
variability, and helps identify crack which may have crack indications liners and comparing results against
indications at a higher success rate. If without signs of clashing nor does post-outage performance to determine
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 47
allowable flow tolerances—this to for replacing one or more discs—if other unit required 5200 psi to break
maintain firing temperature at the necessary. loose the ring segments.
highest possible level and prevent loss n Candidate contractor’s rotor inspec- Other discussion points: Replace-
of top-end megawatts. Another objec- tion capabilities and experience. ment of a failed R17 blade (TIL 1346),
tive is improved repair processes to n Candidate contractor’s EOL analyti- shim pinning according to TIL 1562-
achieve repeatable results with ven- cal and engineering capabilities. R1, and turbine shell-to-exhaust frame
dors and reclaim lost output. The gas-valve upgrade presen- slippage (TIL 1819-R2).
Rotor end of life (EOL). The speaker tation provides some project photos,
explained the following four options for data, calibration settings, operating Registered users can access the
rotor failure mitigation: parameters and other information of presentations summarized above on
1. Replace the existing rotor with a value to users considering migration the organization’s website at http://
new or refurbished one. This is the from hydraulic actuation to electric. ge7ea.users-groups.com.
highest-cost/lowest-risk option but This information, combined with the
one seriously worth considering if
you have majors for multiple units
experience from a recent Frame 5
fuel-valve upgrade (CCJ 2Q/2017, p
Wrapper leak
in the same year.
2. Refurbish to regain half a lifecycle.
95), should help any owner/operator
considering a similar project.
mitigation
This is a less expensive but higher- 7EA compressor issues. A It’s the rare 7EA Users Group meet-
risk alternative than the first option. hands-on engineering manager dis- ing that does not have some discussion
3. Replace key rotor components to cussed issues experienced during exe- on attempts to mitigate leakage from
achieve life extension—less expen- cution of TIL 1884 recommendations. combustion-wrapper joints. “Attempts”
sive than the first two options with If clashing is in evidence, removal of is italicized because success has been
less risk than the second. S1 vanes may be necessary. Options elusive. Jason Hampton, who chaired
4. Inspect but do not repair may be the for removing them: Pull the rotor or the steering committee until exiting
option of choice depending on the leave the rotor in place and try to the user side of the industry early in
strategy for unit retirement. This is push the lower-half ring segments 2017, presented on the documented,
the lowest-cost/highest-risk option out of the case. The presentation deeply rooted frustrations experienced
of the four presented. illustrates how the OEM’s stator by owner/operators since before the
The presenter closed by listing removal tool handles the task with millennium, to eliminate leakage at
critical items to consider before for- the rotor in place. casing joints—the four-way joints in
mulating an EOL evaluation plan and The speaker said the special tool- particular.
selecting a vendor: ing was successful on both machines Hampton generally attributed leak-
n Availability of rotor discs (OEM or serviced, but the task was challeng- age to an OEM design issue, which, in
third-party manufactured) if one or ing. On one unit, the hydraulic power his opinion is related to insufficient
more do not pass inspection. unit developed 3100 psig to free up clamping force in suspect areas. A
n Capability of the EOL contractor segments with heat and quench. The contributing factor is casing distortion
48 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
7EA USERS GROUP
suffered during operating regimes n Peening over mating areas
not envisioned by designers. reduced the amount of air leaking
He invested a considerable by the joint but did not eliminate
amount of personal time to peruse leakage.
the 7EA User Group’s discussion- Silver Seal II applied Hampton then reviewed the
forum archives hosted on its web- various leak-mitigation methods
site at http://ge7ea.users-groups. attempted by the OEM, contrac-
com and to survey owner/opera- tors, and users with marginal suc-
tors about their experiences. Here cess. Here are the editors’ notes
are a few of the comments, shared Can 3 from that portion of the presenta-
in several discussion threads on tion:
the forum from 2004 through Sealants, standard bolting
2012; most have been edited to practice. Research suggested that
reduce word count: a sealant and proper bolting should
n Split-line gaps on 7EAs are provide temporary leakage relief
common and to my knowledge (Fig 12). However, expect fluid
GE does not offer an effective temperature and pressure to erode
means for eliminating wrapper 12. Use of a sealant and good bolting prac- or blow out the sealant over time.
leakage. Sealants have been tices is the simplest way to mitigate wrapper Obtain appropriate torque values
tried with limited success. leaks . . . temporarily from GE spec 248A4158, “Bolt &
Wrapper horizontal
joint seal-welded
BEFORE AFTER
13. Welding of wrapper joints is an alternative leak-mitigation method. Here 14. Some users say welding strips
the inner split-line gap is in evidence (left) with Can 3 removed. After welding of plate to the outside horizontal joint
(right) the weld area must be machined even with the flange face is the most effective way to eliminate
wrapper leaks
Stud Torqueing.”
Among the sealing products sug-
gested: Silver Seal II, a non-hardening
fibrous paste that flows into rough or
irregular surfaces and expands under
heat, curing to a leathery-like consis-
tency. Manufacturer IGS Industries,
Meadow Lands, Pa, claims it will not
crack from thermal cycling or vibration.
Two additional high-pressure/high-tem-
perature sealing compounds suggested
by users include Esco Products Inc’s
(Houston) Copaltite and ICS Industries’
15. Peening is an alternative to welding for mitigating wrapper leaks Turbo-R and Turbo-50.
Weld wrapper horizontal joints
n We are experiencing split-line leaks We still have leaks. together. This is a relatively straight-
on all six of our Frame 7s (five pur- n Leaks on the turbine/wrapper forward process with split-line cans 3
chased in 1989, one in 2001). horizontal joint were mitigated by and 8 removed (Fig 13).
n We ensured that the OEM torque welding straps on the outer cas- Weld strips of plate steel on the
sequence/procedure is being done cor- ing. Further investigation revealed outside of horizontal joints. This,
rectly. Result: Leaks slowed at first. internal leaks by the combustion too, is relatively straightforward as
Grooved the upper casing on one unit cans. Fig 14 shows.
and installed a keyway in the groove; n The original key-way mod was per- Peen horizontal joints after proper
this helped for about eight months. formed on one unit in 2006 but we tensioning and removing combustion
Tried several different sealers, but still have a leak on one side at the hardware.
they were effective only for a short horizontal joint. The bottom line: The goal of peening is to spread
period. Money was not well spent. metal over the joint area where leak-
n On our recent major inspection, we n We tried peening, re-torqueing, weld- age is occurring (Fig 15). Ways sug-
followed jacking instructions to the ing, and the seal-key mod with little gested for doing this:
letter. Plus GE executed the work success. The unit where the original 1. Use an air hammer with a punch
and the field TA (technical advisor) seal key mod was installed leaked attachment.
was one of the best in the business. worse after the repair than before. 2. Strike the casing along the length
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 49
ISO 9001
Certified Quality
Management
Systems
412.798.8990
18. The user jury is still out regard- www.TesTex-NDT.com
ing the effectiveness of the OEM’s
“new” seal key mod (refer to Fig 5). It
is said to be pricey
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 51
7EA BEST PRACTICES
Eagle Point
sance indications. The control system
was configured to monitor spark-plug
cable current during the ignition
sequence and to generate an alarm
when the current drops below the des-
ignated 4% alarm level for more than
three seconds. This alarm remains
uncleared until the operator performs
a master reset on the respective GT’s
Mark V.
When a 7EA is shutdown, the plugs
are positioned with their tips penetrat-
ing into the combustion can liner ID.
In the initial phase of a startup, the
control system performs a purge by
cranking the GT without injecting fuel.
This admits fresh air into the down-
stream spaces (GT exhaust and HRSG)
Portable CO2 cylinder skid
in order to remove any combustible
mixtures that may have accumulated.
eliminates ergonomic hazards
After the purge is complete and Challenge. Reduce the potential for
the unit is at firing speed, the control personal injury in the handling of CO2 Eagle Point Power
system energizes the ignition circuits cylinders stored at each of the plant’s
for 60 seconds while fuel is admitted hydrogen-cooled generators for routine
Generation Facility
to initiate combustion. When proper and emergency purging. Owned by Rockland Capital Assets
ignition is achieved, the control sys- When individual cylinders are emp- Operated by NAES Corp
tem gradually accelerates the unit to tied, new ones must be moved from a
operating speed. storage area located far from the point 250 MW, gas-fired 2 × 2 combined
During acceleration, pressure of use. Each 175-lb cylinder has to be cycle located in Westville, NJ
builds in the combustion cans and lifted and maneuvered into position Plant manager: Frank Meade
the spark plugs auto-retract by over- inside the storage cabinet provided
coming insertion spring pressure. for each generator (Fig 1). Between to the generator for purging (Fig 2).
They remain retracted while the unit eight and 12 cylinders are used during The crate remains outside the cylin-
is operating. During the subsequent a routine purge. der compartment during purging. Two
unit shutdown and coastdown, the This creates several hazards—in cylinders are retained in the cabinet
pressure in the combustion can reduces particular, ergonomic issues associ- for emergency use. After a purge is
to a point where spring pressure is able ated with awkward body positioning completed, the empty cylinders are
to reinsert the spark plug, preparing and pinch points. Plus, with relatively moved back to the storage area by
it for the next unit start. few operators on shift, the existing forklift.
Staff configured the system to procedure can take excessive time in
passively monitor spark-plug per- an emergency situation. Results. The cylinder handling system
formance during every start, so no is performing as intended, mitigating
operator action is required. When Solution. The operations department’s injury risk to plant personnel.
it identifies a potential spark-plug Don Stasio developed a solution by
malfunction and generates an alarm, rethinking the existing cylinder han- Project participants:
the operator notifies appropriate dling system. He and co-workers Don Stasio, plant operator
personnel so the spark plug can be designed a six-cylinder crate which Jeff Hawksworth, maintenance plan-
removed and replaced at the next can be moved by forklift. A 10-ft hose ner
unit shutdown opportunity. is used to connect cylinders in the crate Frank Meade, plant manager
Results. During the three years the 1. Two CO2 cylinders are retained in the storage
systems have been in service, they cabinet at the generator for emergency use (left)
have proven extremely effective in
identifying ignition-circuit issues, 2. Hose connects six-pack of CO2 cylinders to
generating around 10 alarms collec- the purge system (below)
tively. In every case, when the cor-
responding spark plug was removed
and tested, personnel confirmed that
a malfunction had occurred resulting
in a degraded spark or no spark at
all. Without this system alerting staff
to developing issues, Ferndale could
presumably have incurred several
failed starts along with the associated
impacts.
Compelling program
makes this annual
meeting a top priority
I
t’s time to decide which confer- ning from 9:30 a.m. to 4:00 p.m.— If you have never attended a 501F
ences you will attend in the first allowed each attendee to participate Users Group meeting, make the 2018
quarter of 2018, if you haven’t in up to seven presentations. Note conference your first. The following
already done so. that Vendorama presentations are report, based on information aggre-
The first major user group meeting vetted by the steering committee gated from the 2017 meeting, offers a
of the year is the 501F Users Group to ensure a technology focus and to glimpse at the knowledge you will gain
conference and vendor fair at the Hyatt eliminate blatant sales messages. by participating. Material like this,
Regency Grand Cypress, in Orlando, n Vendor fair, following the Vendora- possibly vital to your plant’s future
February 25 to March 1. CCJ editors ma program on the first day of the success, is not available in one place
rate this is a “must-attend” event for meeting, which last year provided anywhere else (QR Reg).
owner/operators of 501F engines. users the opportunity to peruse the Important note for shy O&M per-
The all-volunteer organization’s offerings of 89 vendors. The 2018 sonnel: The 501F Users Group is a
steering committee (sidebar) has post- exhibition will be similar. collaborative organization and first
ed the agenda on the group’s website timers (about half of the 125 to 150
(scan QR code Agnd on p 56 with your attendees typically expected at an
smartphone or tablet). This year’s pro- annual meeting) are accorded the same
gram has many of the same compelling respect as veterans.
elements as the information-rich 2017
conference, which ran four and a half
days and included the following: User
n User presentations on issues iden-
tified in the fleet and solutions
2018 Conference presentations
implemented, as well as on experi- and Vendor Fair Three user presentations were selected
ence with upgrades to improve unit Hyatt Regency Grand Cypress by the editors for inclusion in this
performance. Orlando, Fla report. All have elements of value to
n User-only roundtables promoting February 25 – March 1 most 501F owner/operators; plus, they
open discussions and short pre- Steering committe illustrate the value of participating in
sentations by owner/operators on Officers and board members: the organization’s meetings.
safety, combustion section, hot-gas
Russ Snyder, Cleco Power LLC
section, inlet and exhaust, compres-
President and Chairman Turbine blade-ring burn-
sor, rotor, generator, and auxilia-
ries. The roundtables typically run Paul Tegen, Cogentrix Energy Power
through
an hour each. Management LLC Vital stats: 2 × 1 combined cycle pow-
n Special closed sessions, ranging Vice Chairman ered by 501FD2 gas turbines com-
from two to four hours each, by missioned in 2001 with an average of
Carey Frost, Duke Energy
major products/services providers. nearly 60,000 equivalent operating
Secretary
Mitsubishi, PSM (Ansaldo Energia hours per engine and nearly 3200
SpA), Siemens, and GE are on the Board members: equivalent starts.
2018 agenda. John Burke, NAES Corp/LSP-Cot- Incident profile: One engine tripped
n Vendorama program. Last year, 38 tage Grove LP on blade-path spread; a high-tempera-
companies made 41 technical pre- Blaine Gartner, Xcel Energy Inc ture alarm was received for disc-cavity
sentations ranging from 30 to 50 David Lucas, PacifiCorp (DC) 2 prior to the trip.
minutes each to bring users up to Arlen Morris, NextEra Energy Inc/ Initial findings:
date on products/services of inter- FPL n Event lasted three minutes.
est to the 501F community. The Jeff Parker, SRP n Combustion seemed stable.
ink was not quite dry on the 2018 Ramon Gonzalez Recio, Falcon n Inlet-bearing vibration increased
lineup when CCJ went to press in Group/Comego slightly during the event.
mid-December. IT officer: n Blade-path thermocouples (TCs) 1
The 2017 program matrix—seven Dave Gundry, Xcel Energy Inc and 16 increased to 1185F and then
time slots in each of six rooms, run- dropped to less than 1000F, causing
54 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
TURBınE ınSULATıOn AT ıTS FınEST
INNOVATIVE
Industry veterans may recall that MHI
PROTECTION
and Westinghouse Electric Corp had
shared a technology agreement and
partnered in the development of the
original 501F gas turbine. That part-
nership was terminated shortly after
Siemens’ acquisition of Westinghouse THAT OUTPERFORMS BY COVERFLEX
in November 1997.
Nose to the grindstone, Walsh
followed the business plan that was
developed and built world-class manu-
facturing facilities. He hired top-notch
leadership and staff, and quickly dem-
onstrated the ability to stand toe-to-
toe against companies that had been
serving the US market for more than
a century.
At first, Mitsubishi focused on new-
unit sales and parts and services for
its equipment. In addition to the new
M501F and M501G gas turbines that
were sold, the company offered after-
market solutions to owner/operators
of Siemens Westinghouse W501F
engines, having intimate knowledge of
WE DESIGN, FABRICATE & INSTALL CUSTOM
those machines—in particular, models
up to the FD3.
REMOVABLE INSULATION SYSTEMS FOR TURBINES
Early in 2014, Mitsubishi and
Hitachi agreed to a joint-venture of
WITH TOP PERFORMING FABRICS & MATERIALS.
their power-generation business units,
and Mitsubishi Hitachi Power Systems REMOVABLE SYSTEMS INCLUDE:
(MHPS) was created (QR MH1). Along
with this JV came Mechanical Dynamics • SINGLE & DOUBLE LAYER • EXHAUST WALL SEAL
& Analysis, a three-decades-old company
specializing in “other-OEM” services, • HEAT TRACING • CONVENTIONAL WITH REMOVABLE • ACOUSTICAL
parts, and repairs of gas and steam tur- • INSTRUMENT THERMAL PROTECTION
bines and generators (QR MH2).
MD&A, launched by a former GE
employee, had built a reputation as Visit us online for a full list of innovative technology,
a trusted OEM-alternative services design, fabrication, and installation services.
provider with a skilled workforce and
world-class facilities—such as its high-
speed balance center in St. Louis.
The JV essentially provided MHPS
full access to the generation aftermar-
ket business in the Western Hemi-
sphere overnight. Today the com-
pany typically services Mitsubishi
and Siemens equipment in its shops
while MD&A focuses on “other-OEM” www.coverflex.net 6828 La Paseo St. Houston, TX 77087 713-378-0966
equipment. Both rely on each other’s
facilities as necessary to meet customer
commitments. successor. Like Walsh, Browning outage schedules were another positive
After 15 years at the helm, Walsh embraces a robust presence at user- mentioned.
retired in March 2016. Major initia- group meetings. In fact, the four-hour Two more takeaways: (1) MHPS is
tives completed during his tenure MHPS program at the 2017 meeting receptive to developing solutions with
included construction of the high- of the 501F Users Group, Browning’s users and has the flexibility to support
tech Savannah Machinery Works first, may have been the company’s these initiatives. (2) It has digital solu-
manufacturing center, the merger of best ever—at least in the editors’ eyes. tions ready for implementation that
Mitsubishi’s and Hitachi’s thermal- Mark Bissonnette, VP service benefit both reliability and customer’s
power-generation systems businesses sales and marketing, opened the ses- bottom line.
with the new name of Mitsubishi Hita- sion with the welcome message that Travis Pigon, a gas-turbine design
chi Power Systems, and expansion of MHPS had improved the competitive- engineer began by offering visual evi-
the organization to more than 2000 ness of its offerings and was respond- dence to validate a 32k service inter-
employees. ing to RFQs faster than in the past. He val for hot parts. He showed photos of
Paul F Browning, an experi- stressed the importance of quality in M501F turbine blades and vanes with
enced senior executive with roots in company activities, illustrating its suc- up to 40k equivalent fired hours (EFH)
the power-generation and oil-and-gas cess with a 97% first-pass yield on its and more than 1000 equivalent starts
industries, was appointed Walsh’s turbine blades and vanes. Compressed (ES) with no visible platform cracking
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 61
501F USERS GROUP
or erosion; coatings were intact, too. newest fleet issues. ment. This would benefit users because
The parts were fit for service with He addressed corrosion first, saying after initiation, crack propagation is
light repairs or none at all. Registered some units may go 12 or more years slow. It is followed by rapidly progress-
users can access this and the other before their first HGP. Corrosion ing high-cycle fatigue and failure. Thus
MHPS presentations at http://501f. occurs primarily because of condensa- early crack detection would allow for
users-groups.com (QR Presen). tion in a cold rotor cycling in and out outage planning and parts acquisition
The benefits of upgrading a of service while subjected to ambient- before a vibration event.
W501FD2 engine with MHPS F3 temperature and humidity changes. A few technical solutions mentioned
parts was the subject of a case history The condition is exacerbated when by Cloyd were rotor replacement
presented by Pigon. He said F3 parts wear from blade rock reduces the con- (exchanging with a new or refurbished
enabled a threefold increase in EFH tact area between the blade and disk rotor), in-kind torque-tube replace-
between inspections, from 8k to more fir-tree serrations. This concentrates ment, and an upgrade option. The last
than 25k (approximately 115 ES); gas- stress at the top-most serrations; includes a replacement torque tube
turbine output increased by approxi- defects in the serrations below can with additional thickness where cracks
mately 4% and heat rate improved by amplify stress in the already highly have occurred and with a bolted air
greater than 1.5%. Once again, photos stressed locations. separator (elimination of the spring-
of parts proved his findings. This was a vintage Cloyd engineer- loaded goose-neck design).
Five more units covered by the LTSA ing lesson of value to users (QR MH3). Cloyd is a fountain of information.
also were upgraded with F3 parts. Consider reviewing his presentation in There were several other parts to his
In all cases, the speaker said, tuning detail (QR Presen). presentation of considerable value
was accomplished without unexpected The first of the four case histories to users—including a CRI planning
issues. Output improvement across the Cloyd reviewed, and the only one pro- checklist, a list of recommended pre-
five engines ranged from approximately filed here (another reason to access CRI inspections, photos of historical
3% to 7%, heat rate by 1.5% to 5.5%. Cloyd’s presentation), involved a hot- rotor findings, turning-gear wear and
Expect improvement to vary among gas-path inspection on a W501FD2 corrosion-prevention options, etc. This
engines because of the level of compres- machine that had operated for 12 years presentation is too good not to have
sor cleanliness, wear and tear on parts, in peaking service. It took four shifts a copy of.
condition of seals, etc. just to remove R1 blades. Corrosion Jim Kelleher, director of turbine
For MHPS users, Pigon covered the was severe, rendering magnetic-particle and generator repairs, presented on
highlights of an M501F3 upgrade to examination ineffective. Replicas quan- the company’s new turbine and gen-
F4 during a standard major inspection tified pitting in critical stress areas. erator repair group, with facilities in
outage to improve engine performance Dental molds were taken of the Savannah, St. Louis, and Houston.
and durability. He said the F4 upgrade turbine-disc root serrations. Blue- He quickly reviewed the company’s
is applicable to the W501F fleet as light scans were performed on the onsite and shop capabilities and then
well. Inspection after the first interval molds. Areas of corrosion buildup were focused on generator inspection, test-
revealed intact coating, no base-metal identified in high-stress regions and ing, and aftermarket solutions. The
degradation, and the capability to meet could not be removed safely. Bear in new organization combines the talents
32k intervals. mind that such buildup can conceal of both MHPS and MD&A to repair and
The speaker closed with a positive more severe pitting, adding to the provide parts for generators supplied
view of MHPS’ exhaust cylinder solu- risk factor. Plus, buildup impedes by MELCO (Mitsubishi), Hitachi, GE,
tion for the W501F based on improved blade installation, thereby increas- Alstom, Westinghouse (read Aeropac),
material, floating diffuser system, ing outage duration, cost, and risk of Toshiba, and Brush.
cooled robust aft static seal, and passive assembly damage. Compressor discs He spoke to the “technical differen-
strut cooling system. Improvements to also revealed corrosion pitting. tiators” in both generator inspection
the original W501F exhaust manifold: The customer’s decision was to and repair services that Kelleher said
improved material, reduced upstream remove the rotor because of the put the greater MHPS organization
flange thickness, partitioned teardrop, unknowns and potential safety and ahead of the competition. An example
vertically bolted two-piece manifold, financial risks. MHPS supplied an was the company’s new High Heat
elimination of circumferential ribs. exchange rotor to reduce downtime Transmission (HHT) insulation sys-
The MHPS offering is a drop-in and return the unit to service quickly tem on stator bars, which provides
replacement with no aux piping or (QR MH4). enhanced heat-transfer properties that
foundation changes necessary. Design Torque tube cracking was next lower stator-bar operating tempera-
is based on the company’s M501F3- on Cloyd’s agenda. Recall that the tures by 7% to 10%. Kelleher recalled
and G-frame designs, which have no torque tube on W501F engines joins the “Rule of 10”: Life of electrical
history of fatigue cracking in more the compressor and turbine sections insulation is reduced by half for each
than 10-million hours of operation. A of the rotor. Two machines in the fleet rise of 10 deg C in insulation average
feature stressed: Ability to remove the had reported forced outages caused temperature.
exhaust bearing through the teardrop by vibration events traced to through The technical solutions presented
rather than removing the tail cone or cracks in their torque tubes, which were aimed at helping users better
the upper half of the exhaust cylinder. were concealed by the air separator. plan for outages and extend service
Scott Cloyd, GM gas turbine The through crack was found on one intervals.
service engineering, focused on the unit, after only 10k operating hours Matt McGough, product line man-
company’s experience gained during (but 90k turning-gear hours), and it ager, took attendees on a tour of the
more than 200 comprehensive rotor continued for about 45 deg around the company’s Orlando Repair Center
inspections (CRI)—including about a circumference of the torque tube. High (where it performs gas-turbine com-
dozen at its Houston and Savannah vibration forced the unit out of service. ponent repairs), covering capabilities,
facilities. One of his primary objectives At this time, visual inspection for manufacturing and repair processes,
was to raise user awareness regarding torque-tube cracking is not possible specialized tooling, design improve-
corrosion and torque tube cracking, while the rotor is assembled. However, ments, etc. You can see the high-
cautioning that these could be the Cloyd said a method is under develop- light reel at your desk by accessing
62 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
SAVE THE DATE
2018 Users
Conference
& Vendor Fair
June 11th - 14th, 2018 Come spend a half day
with award-winner
John Peterson
Marriott Sawgrass Golf Resort & Spa and his views on best
practices/lessons learned
Ponte Vedra Beach, FL
in Frame 6 design,
operation, and maintenance
frame-6-users-group.org on Monday, June 11
+1 (678) 388-1255 1:00 - 5:00 pm!
!"#$
501F USERS GROUP
McGough’s presentation in the con- Hyatt Regency Grand Cypress will be an advanced DLN or ULN combus-
ference archives at http://501f.users- more productive if you can make time tion system, improvements in blades,
groups.com. to review this material beforehand vanes, exhaust system, and rotor can
He said the following are key “dif- and write down questions to ask both maximize your return by extracting
ferentiators” that favor MHPS in the the OEM’s engineering team and user another 31 MW from the base FD2
contractor selection process: colleagues with first-hand experience. engine while reducing heat rate by
n Extensive operating history and val- For the record, there are 275 501F- more than 600 Btu/kWh. Significant
idated repair techniques—including FD3 machines in the worldwide fleet improvements also can be realized for
heat treatments, tooling, inspection, (nearly two-thirds of those FD2s) FD3 machines—as much as 16 MW
and coatings. and well over a hundred 5000F(4)- more output with a heat-rate benefit
n OEM design authority onsite to 5000F(5ee) engines. Some of the of nearly 240 Btu/kWh.
respond to fleet issues with devel- upgrades covered by Natu also are Technology advancements
oped proven repair criteria. applicable to the Mitsubishi 501F fleet, offered by the FD6 rotor as a replace-
n One-stop overhaul shop offering which is about one-fifth the size of the ment for FD2 and FD3 rotors were
OEM quality at competitive pricing. Siemens fleet globally. said to include materials changes to
Paul Richmond, strategic parts Key takeaways from the presenta- improve yield, creep, and fracture
manager. “Parts Strategy to Reduce tion include the following: properties. New compressor tie bolts
Lifecycle Costs” is a presentation you Interval extension products for and nuts and elimination of the air
should access if adding MHPS to your hot-gas-path (HGP) components in separator contribute to higher reli-
bidder’s list for aftermarket services. engines with advanced ULN (ultra low ability and performance.
Richmond reviewed the company’s NOx), advanced DLN (dry low NOx), Exhaust system. It seems no 501F
process for bid evaluation and pro- and DLN 1.1 combustion systems are discussion is complete without cover-
posal creation, offered current trends available and expected to run 33k age of improvements to correct short-
in repair classification and fallout, and equivalent baseload hours (EBH) or comings in the design of the original
presented MHPS’ strategy for reducing 1200 equivalent starts (ES) between Westinghouse exhaust cylinder and
lifecycle maintenance cost. overhauls—for example, from instal- exhaust manifold. Three participants,
lation to the first HGP inspection and including Siemens, spent meaningful
Siemens from it to the first major. Combustion podium time to extoll the virtues of
inspections have been eliminated. their designs, especially service dura-
Frame Owner Shantanu Natu did Slides dedicated to each combustion bility (QR Sie2).
the heavy lifting for Siemens with a system describe features of major com- Natu presented two options to
crisp, informative presentation on the ponents—baskets, pilot nozzle, support attendees—a single-piece exhaust
SGT6-5000F (a/k/a 501F) product line housing, transitions, transition seals, (SPEX) for models FD3 and above,
hitting the following core interest areas and R1 vanes—that enable the interval and an advanced two-piece exhaust
of attendees: extension and performance improve- for FD2 and earlier models. The for-
n Interval extension. ment. To illustrate: For the advanced mer was cited for its thermal perfor-
n Performance upgrades. ULN system, baskets have two rows mance improvements; the latter is a
n Rotor upgrades. of resonators, offer resonator-ring drop-in replacement to maintain the
n Exhaust options. durability, and feature an improved existing turbine cylinder and manifold
n Turndown technologies. spring-clip coating. interface.
Natu’s presentation filled about half If you take the time to retrieve Turndown to low load while still
of the two-hour Siemens session. He and review Natu’s slides you’ll also maintaining less than 10 ppm CO
was followed by Andy Media who spoke see how many engines are operating emissions is an important consider-
on repair technology developments, with the various improvements. For ation for owner/operators today. The
Adi Srinivasan on digital products, example, there were 54 machines in first Siemens product—low-load turn
Jeff Williams on field-service develop- the F, G, and H fleets operating with down (LLTD), Version 1—has been
ments, and Galen George on controls the advanced ULN combustion sys- validated to 50% rated output the
and digitalization (QR Sie1). tem when he presented in February; group was told. About 30 units are so
Readers are encouraged to access another 19 were in the queue at that equipped. Version 2, installed on eight
the presentations, Natu’s in particu- time. Personnel from some of these units at the time of the meeting, has
lar, on the user group’s website at plants will be at the 2018 meeting, giv- advanced logic to accommodate turn-
http://501f.users-groups.com. There ing you the opportunity to get details down to 30% to 35% load. Natu put
is a tremendous amount of material on installation and performance direct up a slide to illustrate piping arrange-
of value to owner/operators in the from colleagues. ments for both versions, the system for
well-organized slides. Natu’s focus on The advanced ULN combustion V2 obviously more complex.
the upgrade options available for each system can restrict NOx emissions An engineering and financial analy-
model in the fleet—especially the F to less than 9 ppm at the exhaust sis of both versions as they pertain to
(introduced in 1993), FC+ (1996), FD1 manifold without water injection and your plant and its operating profile
(2000), FD2 (2001), and FD3 (2005)— do that 90 deg F above the standard is recommended. While both offer a
can make these machines more com- FD2 firing temperature to improve part-load heat-rate benefit, being able
petitive in the increasingly challenged performance. The DLN 1.1 is capable to operate down to about one-third
fuel-fired segment of the industry. of restricting NOx emissions to 25 ppm rated output, rather than one-half, may
Natu also covered the F4, F5, and while operating at a firing tempera- extend the life of hardware by allowing
F5ee engines and their experiences ture 20 deg F above that of a standard the plant to continue in operation at low
with the technology advancements 501FD2; the advanced DLN also holds load rather than debit the fatigue bank
introduced between 2009 and 2017 NOx to 25 ppm, but while firing 70 deg account by shutting down and cycling.
and now offered to the earlier models F higher than the FD2. Also, V2 requires an inlet heating
where applicable. Your participation Natu went on to discuss many system which would benefit the engine
in the 2018 meeting of the 501F Users thermal-performance upgrade options by reducing the potential for ice forma-
Group meeting Feb 25 to Mar 1 at the for F-class frames. For example, with tion and possible downstream damage.
64 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
501F USERS GROUP
+ Chemistry Investigations
+ Cycle Chemistry Training
TM
not having to run tests for nine months fatigue), focusing on oxidation. Recall Guidelines for inlet filter selec-
after the upgrade was completed saved that the degree of oxidation depends tion, CLARCOR Industrial Air Inc
about a quarter of a million dollars. on temperature and time, the former (QR Ven5).
controlled by the cooling scheme, An important takeaway from the
Next generation turbine insula- explained with a series of excellent presentation’s first dozen slides was that
tion, ARNOLD Group USA LLC (QR drawings. poor air filtration accounts for approxi-
Ven3). Laredo Womack, operations man- mately 60% to 80% of overall GT losses.
ARNOLD Group’s single-layer insu- ager for the company’s Component Div, That statement alone was incentive to
lation system was said to be state-of- said the weakest links in the cooling listen to Dan Burch, who reinforced his
the-art technology capable of solving chain described were the leading-edge presence by way of example: An F-class
all known insulation-related problems air dam and the inner pressure pan/ gas turbine operating 8000 hours annu-
associated with the operation and bathtub. ally and selling power at $50/MWh pays
maintenance gas and steam turbines. Failures generally are caused by a a penalty of about a quarter of a million
During operation, it enables users loss of cooling air to the showerhead dollars for every 1 in. H2O increase in
to decrease compartment temperatures on the leading edge and/or to the pin pressure drop across the inlet air system.
significantly—by more than 50% in fin cooling on the trailing edge. Photos The obvious message: Dirty filters can
some cases—while decreasing fuel illustrated typical damage. cost you big time.
consumption and increasing power pro- After passing mention of conven- Following an overview of filter rat-
duction. During maintenance activities tional repair processes (solution, blend, ings and typical industry tests, he sug-
it reduces outage time and related cost jacking, welding, stress relief, machin- gested several other tests you should
because there are fewer blankets to ing), Womack dug into advanced ask prospective vendors to conduct on
remove, repair, and replace. Plus, less repairs—coupon replacement, core- their products to enable an informed
local insulation labor and less scaffold- plug guide replacement, and brazing buying decision, including these:
ing are required for outages. (wide gap, narrow gap, and preform, n Dust and salt removal efficiency.
ARNOLD’s Pierre Ansmann said or slump, if you prefer). Unfamiliar n Humidity, mist, and fog testing.
the company guarantees reuse of its with slump brazing? It is a method n Burst tests, both wet and dry.
insulation system for 15 outages with- for repairing highly contoured areas n Dust holding capability.
out a decrease in efficiency. on airfoils that have become too thin. n Rough handling testing.
It’s benefit: Extend vane life at optimal n Hydrophobic performance with
Advanced repair processes for time and cost. loading.
501F vanes, Sulzer Turbo Services Drawings detailed how vanes are n Temperature-extreme suitability.
Houston Inc (QR Ven4). sectioned for coupon repairs, photos n Gasket testing.
First half of the presentation was illustrated the repair process—coupon n Overall performance (beta site trials
dedicated to the primary failure modes fitting, bracing, throat check, plating, and mobile test rigs).
of 501F vanes (oxidation, thermal welding, NDT, and re-establishment Burch then conducted a side-by-side
distortion, and thermomechanical of cooling holes. comparison of HEPA filters made of
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 67
SAVE THE DATE
microfiber glass media and ones made liters of water removed from the oil), Benefits of maximum access for
with a layer of d-PTFE membrane. He 2-micron particle contamination was borescope inspections, Advanced
concluded the former as better able to reduced from 28,860 to 17,041, and Turbine Support LLC (QR Ven10).
handle the moisture than the latter. sodium and potassium levels were This is a must-view presentation
reduced below recommended levels. because the story is told in pictures
Online transformer oil condition- illustrating the level of detail possible
ing, C C Jensen Inc (QR Ven6). Oil sampling: Particle counting, for accurate damage assessment when
Transformer oil conditioning was Hy-Pro Filtration (QR Ven9). adequate access is provided for bore-
only part of Axel Wegner’s presenta- Selecting a sample port for trending scope inspections. A few of the many
tion, which also covered in overview particle count was the focus of this components shown include the follow-
fashion the conditioning of steam- and presentation, which is recommended ing: inlet-strut cracking, compressor
gas-turbine lube oil, (QR Ven7) control viewing (by the editors) for anyone impact damage, locking-key wear, aft
fluids, cooling-tower fan gear oil, (QR responsible for oil sampling, because movement of compressor blades, dia-
Ven8) and diesel fuel in storage. of its practical approach and level of phragm wear buttons, hook-fit wear
The last was a new entry in the detail. measurement, missing tie wire in the
conditioning playbook for powerplant The main point is that you can combustion section, cracks in rocket
oils. Most users are familiar with treat- acquire an oil sample to check fluid swirler supports, turbine-blade plat-
ments for lube and control oils, but the health and chemistry (acid number, form cracks, etc.
conditioning of diesel oil at a dual-fuel viscosity, additive package condition, Separate sections of the presenta-
plant was unknown to many. At the dissolved metals, water, oxidation) tion covered the following:
plant Wegner described, one equipped from virtually any location in the sys- n Exhaust-strut inspections—visual
with a nominal 1-million-gal storage tem. However, locations for trending damage assessment, dimension-
tank, the gas-supply failure plan called particle count are limited. The two rec- al checks, liquid-penetrant and
for running gas turbines for three to ommended were at the lube-oil pump phased-array inspections of welds—
five days three times annually. outlet upstream first filter assembly made possible by access gained
The oil was not up to the quality and from the reservoir cooling a pol- through the exhaust duct.
required for GT use and the plant ishing loop upstream filter assembly. n Compressor spindle bolt in-situ
had no choice but to remove water, Location of the sample port is inspection using advanced phased
microbial contamination, and particu- important, too, with the middle 50% array. Sectoral image and waveform
lates from the fuel before burning it. of the pipe the optimum. Several slides scans illustrate the power of the
Using a filtration system similar to describing placement are a “how to” technique.
that used by C C Jensen for turbine for those who have not performed
oil was a viable solution. In only one this task previously. A couple of case Lifecycle cost considerations for
pass through the filter, water content studies with charts of sample data GT inlet filtration systems, Camfil
was reduced from 702 to 71 ppm (1500 were provided. Power Systems (QR Ven11).
68 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
TURBınE ınSULATıOn AT ıTS FınEST
The lifecycle cost analysis provided n Improve startup consistency and stator design, laydown space, crane
for a high-efficiency, medium-velocity ensure on-time breaker closure. availability, etc.
air filtration system incorporating n Reduce plant chemical consump- Then comes the nitty-gritty, slide
weather hood, turning vanes, pre-filter tion. after slide. A couple of examples to
(F6, F7), and final filter (F9, E10) n Improve shutdown procedures to encourage viewing of the presentation:
illustrates how you might perform an bottle-up the unit for fast, efficient n Sure, you have lots of space, but it’s
in-house analysis to aid management restart. outdoors. Where do you store your
decisions. n Reduce metal fatigue. field? Significant planning/logistics
Inputs to the equations provided n Improve overall plant reliability. are required to provide sufficient
include gas-turbine capacity, revenue environmental/ambient protection,
from power produced, cost of fuel, Aeropak I and II stator rewind FME, etc.
cost of downtime, frequency and cost preparedness, AGTServices Inc (QR n Most combined cycles require
of compressor washes, and filtration Ven14). “working at height.” This can pres-
costs—including disposal fees. When you think your generator ent logistical challenges for field
The case study profiled considered rewind project is well-planned, that’s removal. Are there axial impedi-
lifetime costs (replacement filters, when to access Jamie Clark’s presenta- ments to crane access to the field?
etc) and identified key cost drivers. tion and go through his 40-plus slides Many units have buss work running
The summary chart of results in this to identify what you’ve forgotten. This axially out of the collector end, add-
instance showed a financial benefit for presentation is a checklist which may ing to disassembly work, etc.
using a pre-filter and E10 final filter be worth its weight in gold to anyone n The field removal “platform” may
over an H14. lacking rewind experience. Even if become your “dance floor” for the
you sat in on Clark’s presentation you rewind. But some additional costs
501F turbine update, Emerson Auto- likely couldn’t take notes fast enough (such as equipment rental charges)
mation Solutions (QR Ven12). take down all the best practices and may offset the perceived benefits
Tom Zuvlis spent his time at the lessons learned. and saving from less scaffolding,
front of the room discussing strate- The first slide confirms why you’re etc.
gies to optimize the performance considering a stator rewind: the
of 501F-powered combined cycles effects of age, increase output, design Outage preparation and conduct,
equipped with Ovation control sys- deficiency, or winding damage, etc. TOPS LLC (QR Ven15).
tems. He focused on a suite of advanced Several photos serve as a wake-up Toby Wooster began his presenta-
applications (QR Ven13) that individu- call, illustrating insulation break- tion positing that the natural flow of
ally, or in various combinations, can down experienced by others. Next an outage can be disrupted, enhanced,
achieve the following: slide: A list of general outage consid- degraded, empowered, or destroyed
n Reduce fuel use on cold starts and erations—including plant configura- by a number of factors. History and
on warm and hot transitions. tion, other shaft-line work planned, systematic study, he said, can identify
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 69
501F USERS GROUP
elements that can change an outage in the nature of man stays the same; moments to think about what you’re
both duration and quality. therefore, by identifying and targeting going to do before you do it. Sounds
Safety is intertwined in the culture positive change in outage culture you simple, but by weighing the con-
an outage takes on and can be con- can implement practices that save time sequences of every action you can
trolled when proper steps are taken. and money, and prevent accidents. eliminate accidents.
The flow of safety, as in quality, can Owner/operators typically want the n Attitude—honor up, honor down,
be affected by constructive and proac- same thing, he noted: A safe outage honor all around. Every person
tive practices. To control outage flow that restores the unit to like-new con- involved in an outage is a stake-
by cultural improvements, you must dition while saving as much money and holder in the outage outcome. By
first identify the key elements of cul- time as possible. Some simple actions honoring others, outage culture will
tural change. taken can accomplish these goals. A change for the better and healthy
Wooster identified some positive couple of positive cultural changes the input will occur while positive feel-
ways to improve outage flow that are speaker suggested are these: ings drive the outage to an early
both simple and direct. He said that n Safety pause. Take a couple of completion. ccj
70 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
“connection repair”
LM2500
bine) technical support. from him. Thanks to Paul, I had the
1997—Duke Energy North America, opportunity to join the gas-turbine
director of engineering, responsible industry and work with him. He cre-
for strategic turbine expertise in
both current and developing tech-
ated a legacy that will live on through
all of his mentees. Owner/operators
nologies. Wherever and whenever his name
2000—Dominion Resources Inc, man- comes up it always results in a positive Come up to speed on the
ager of O&M, provide technical comment; no matter whom you talk to.
support and strategic management Even I catch myself thinking, “What latest O&M and design
for a fleet of about 75 gas turbines, would have Paul done?” practices for LM engines in
spanning legacy to advanced tech- He presented himself and his team simple-cycle, cogen, and
nologies. with such class, humility, and respect combined-cycle service to:
2016—GT & ST Consulting Corp, shop he made everyone around him feel val-
build surveillance on complete com- ued and respected. I will never forget IMPROVE reliability,
ponent and unit assembly tasks for how he would refer to all colleagues as
Dominion’s first J machine. his friends, and how when he described availability, heat rate
your role on our team he made you feel REDUCE emissions
Remembrances from. . . like a million dollars.
It is sentiments like this that make MAXIMIZE revenue by
Bob Kirn. Amidst the early 7F people remember Paul for who he was.
Users Group meetings that were Although he will be deeply missed,
providing grid ancillary
more of a fruitless slugfest between the impact he made on those around services
the OEM and a handful of owners him will continue to resonate through Join more than 500 LM user
suffering from bucket munching tur- the years. colleagues from around the globe at
bines, there emerged an individual
the 28th annual meeting of the
who, while already known as a steady Sam Graham. Of all the good things
Western Turbine Users and get:
hand and cool head, would become I can say about Paul White, the one
one of the stalwarts of the gas-turbine that stands out the most is his wonder- ◆ Comprehensive engine-specific
industry. ful character. Paul was a true gentle- technical training focusing on
Paul White, with his steadfast, oft- man in every sense of the word, which current equipment issues.
repeated belief that problem resolution was obvious to everyone around him; Deliverables include a fully illustrated
could be best accomplished through he was a genuine pleasure to be with. Training Manual developed by WTUI
cooperative efforts punctuated by full Paul worked constantly to mentor and repair-depot personnel, and a
disclosure and free discussion, was younger engineers and to make a posi- review of current OEM service
quickly recognized by the user com- tive impact on the 7F Users Group. bulletins and letters. Technical
munity as one who could be trusted to He was a great contributor to the user guidance is provided by Air New
not only “find the solution” but to—and community and a long-serving member Zealand Gas Turbines, GE, IHI, MTU
of such greater importance—“share of our steering committee. Maintenance, and TransCanada
the solution.” You could always rely on Paul to Turbines.
His successful method of coopera- provide a composed and thoughtful ◆ User-only open discussion to
tive effort was so widely recognized voice to any situation. His wisdom share experiences and obtain answers
that even GE invited him to speak to and self-control were vital during the to your questions.
their services group in the company’s hard conversations required with the
◆ An exhibition that brings together
efforts to foster a more cooperative OEM when these machines were in
nearly 200 providers of products and
approach to customer service. Paul had their infancy. Paul could be counted on
services for LM aero engine operating
made a lifetime of sharing his talent when times were rough, always with plants. Learn about new offerings, get
and he agreed to participate, and with a warm heart and a smile. product updates, evaluate in-service
the same level of honestly and enthu- This industry, and this world, could experience.
siasm that he approached everything. certainly use more people like Paul. He
No doubt the subsequent and on-going will be greatly missed. ◆ Benchmark your units against
success of the 7F Users Group is a the fleet with ORAP™ data from
legacy to the open-forum structure he John Gundy. We remember Paul Strategic Power Systems Inc.
promoted and to the personal qualities White as a loving and devoted family
that he so strongly displayed.
For more than two decades, Paul
man, mentor, and friend. Not only was
he caring and compassionate, Paul was
Western Turbine
and I exchanged information, sought humble, adventurous, and enjoyed life, Users, Inc.
and offered advice for never-ending sharing his faith with those around World’s largest user
calamities and frequently crossed him—which was something special.
organization serving LM
paths on the user-group circuit. His His contributions to the industry and
commitment to finding solutions and willingness to teach others from his gas-turbine owner/operators
providing the best information possible life’s lessons were priceless.
to anyone who asked never wavered; I was blessed to be hired by Paul, 2018 Conference & Expo
nor did my personal pleasure in see- and he mentored me before I took Renaissance Hotel/Palm Springs
ing him at meetings and being able to on the role of engineering manager Convention Center
swap stories, bounce new ideas, or just for Dominion Energy’s Combustion Palm Springs, Calif
share a genuine handshake. Turbine Operations. Paul will be March 18-21, 2018
missed at Dominion Energy and by Register online at www.wtui.com
Christa Warren. Paul was the best the many friends he made throughout 513-604-8018
manager and mentor I ever had, and his career.
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 73
7B MAJOR INSPECTON
M
arty Magby was at the 7EA provide a checklist others overhauling was about 1850F. The unit was capable
Users Group’s annual con- 7B-EA engines may find helpful. of 55 MW on a favorable summer day.
ference in St. Augustine But before digging into the details, Interestingly, about three years
the week of October 23, as he urged his colleagues to begin their ago the owner had decided to retire
the editors expected; he’s been a mean- projects with a business case to justify this machine, and two sister units, in
ingful contributor to discussion ses- the proposed work scope. Of course the first couple of years of the coming
sions at this forum for years. However, most users in plant management know decade while continuing to operate a
he came to the 2017 meeting wearing this, he said, but they sometimes jump- conventional steam plant for the next
Allied Power Group (APG) gear after start outage planning—their comfort two decades. “This was the plan when
attending the last 11 years in shirts zone—based on previous experience. I went on vacation,” Magby said, “but
with an owner/operator’s logo. Nothing In his view, this may not produce the by the time I returned, the old plan
should surprise anyone in the electric desired outcome. had been scrapped and I was told to
power industry these days given the Magby’s recommendation: Take a do what was necessary to keep the 7Bs
ongoing structural changes. clean sheet of paper and write down running for 20 more years; the steam
Magby’s forte is large rotating how the asset scheduled for an over- unit would be retired instead.”
machinery. His gas-turbine inspection haul makes money for the owner and Clearly, the gas turbines were better
and overhaul experience is a good fit how it is dispatched. Sounds elemen- suited than a steam unit to accommo-
for APG given its “bundled solutions” tary, but the exercise can be revealing. date the start/stop operation required
initiative and expansion plans. The Next, check the unit’s permits to to fill in around rapidly increasing
recently appointed director of the com- be sure it is offered to the market in renewables generation in the area. The
pany’s field services group, Magby is the most favorable way for the owner. 7Bs could go from cold iron to rated
responsible for planning and manag- That’s obvious, most might say. But load in 10 minutes. They also required
ing work for both union and non-union given today’s rapidly changing market less O&M manpower. Management
customers and for growing the firm’s dynamics, it might not be so. “Opportu- had determined upgrades performed
service offerings. nities” can change virtually overnight. during the major would enable a site
The opportunity to speak with Case in point: The dual-fuel 7B staff reduction from 19 to three with no
Magby for about an hour in a quiet spot Magby was lining up for a major personnel onsite for some hours.
was rewarding: He shared his experi- inspection was in its fifth decade of A review of the “grandfathered” air
ences on a Frame 7B major inspection service and approaching 2500 starts permit revealed the true value of the
completed shortly before joining Allied. and 15,000 hours of operation. Firing old iron. The gas turbines only have an
The project scope and notes below temperature for this “standard” engine annual limit on NOx emissions. Thus
they can be offered into the market at
any at virtually any output—even as
LM6000-powered combined
cycle with OTSG proves
fast, flexible, resilient
By Dave Tateosian, PE, Clean Power Consulting Partners
I
n a power world that typically views equipped with a 10-minute-start aero cycle has the following characteristics:
bigger as better, aero engines often gas turbine (GT), a once-through steam n Fast, offering the 10-min starting
are not considered when it comes to generator (OTSG), a single-pressure capability typically associated with
planning new generation. However, steam turbine (ST), and conventional a peaking unit. Full combined-cycle
given the growing demand for flexible balance-of-plant equipment (sidebar). output and efficiency generally can
fuel-based generation to fill in around This equipment configuration was be achieved from a cold start in less
intermittent renewables, they may fit selected to meet the owner’s need for than two and a half hours (absent
in your future plans. a reliable, efficient, and dispatchable any water-chemistry restrictions).
The goal of this article is to assist you thermal resource capable of starting n Flexible, offering the simplicity of
in decision-making by examining the quickly and providing the operational a peaking unit, the efficiency and
beneficial operating characteristics of a flexibility to address the variability of emissions performance of a com-
recently completed 1 × 1 combined cycle renewable resources. The combined bined cycle, a wide operating range,
and the ability to respond quickly
80 to requested load changes.
800
SCR inlet temp n Resilient, offering full gas-turbine
70
Temperature, F; tempering air on/off
70
SCR inlet temp restrict output to 71 MW; the unit’s
700
60 full-load heat rate of 7800 Btu/kWh
Gas turbine, 600 would be reduced with a lower stack
50 Plant output, net MW gross MW temperature. Duct firing was not
Output, MW
during combined-cycle operation or n The variation of exhaust-gas mass operation or not being added during
the exhaust gas was being cooled by flow through the SCR, depending combined-cycle operation.
use of tempering air during simple- on whether tempering air was Were this a greenfield project, con-
cycle operation. being added during simple-cycle sideration might have been given to a
two-pressure design with benefits of
80 slightly greater output and reduced
800
SCR heat rate. However, capital cost would
70 inlet temp
700 Temperature, F; tempering air on/off have increased given the need for low-
60 pressure (LP) feedwater and steam
600 circuits and associated equipment.
50 Given that the benefit of increased
Plant output, net MW
Steam turbine at electrical output and efficiency occurs
Output, MW
500
40 full load at 63 min primarily at high loads, an evaluation
400 of the expected operating profile would
30 be warranted to assess the cost ben-
OTSG trip at 14 min Gas turbine, gross MW 300 efit of adding an LP system in a unit
20 of this size.
Steam turbine, gross MW
200
10
100
OTSG versus HRSG
Tempering air running
0
0 The table compares operational capa-
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 bilities of a combined cycle equipped
Time, minutes with an OTSG to one with a con-
3. OTSG trip and restart ventional drum-type heat-recovery
steam generator. Note: In this table,
80 “combined cycle” denotes operation
800
Plant output, when gas-turbine exhaust heat is
70
Temperature, F; tempering air on/off
Operational
40 Steam turbine
at full load 400
Gas turbine, gross MW
experience
30 at 7:45
Steam-turbine 300
20 trip at 6:55 To illustrate the unit’s “fast, flexible,
200 and resilient” capabilities, plant-per-
10 Steam turbine, formance trends are provided for the
gross MW 100 following evolutions:
0 Tempering air running
n Cold start (Fig 1).
0 n Warm start (Fig 2).
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 n OTSG trip and restart (Fig 3).
Time, hours n Cold start with steam-turbine trip
4. Cold start with steam-turbine trip and load changes (Fig 4).
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 77
Comparing the operational characteristics of OTSG- and
HRSG-equipped combined cycles
OTSG-equipped combined cycle HRSG-equipped combined cycle
Gas turbine OTSG Steam turbine Gas turbine HRSG Steam turbine
Operates in simple Shutdown On turning gear or Operates in combined Produces steam On turning gear
Gas-turbine
cycle and can reach shutdown cycle. Load may be lim- which is then
startup
cycle over the full shutdown simple cycle (unless in simple cycle down
operation
cycle to warm the shutdown cycle; warmup time which is then HRSG, steam lines, and
Boiler
OTSG so it can varies based on HRSG bypassed to the condenser are warmed
receive feedwater design limits condenser
Operates in com- Produces steam On turning gear Operates in combined Produces steam On turning gear while the
bined cycle with which is then while the steam cycle which is then steam lines are warmed
startup
Steam-turbine Boiler
feedwater flow grad- bypassed to the lines are warmed bypassed to the
ually increased condenser condenser
Operates in com- Produces steam Brought to syn- Operates in combined Produces steam Brought to synchronous
bined cycle which is then chronous speed cycle which is then speed and then loaded;
bypassed to theand then loaded; bypassed to the steam bypass to the
startup
feedwater flow to steam produc- produces steam HRSG shutting down in steam which is
OTSG reduced grad- tion continues and then is shut concert bypassed to the
ually, or all at once, until the OTSG down or trips. After condenser
depending on opera- boils dry the ST trips, steam
tional needs. Opera- is bypassed to the
tion is unaffected by condenser
OTSG shutdown
Operates in com- Following feed- Continues to oper- Operates in combined Continues Typically is shut down
bined- or simple- water isolation, ate while the OTSG cycle, with the gas tur- to produce prior to the boiler
Gas-turbine
cycle mode steam produc- produces steam bine and HRSG shutting steam which is
shutdown
steam-cycle upset steam, which is condenser steam bypassed to the steam, which is denser
ST trip
tion continues and then is shut production con- steam turbine may be
as the OTSG down or trips. After tinues to protect tripped to protect water
boils dry the ST trips, steam water levels in levels in steam drums.
is bypassed to the steam drums After the ST trips, steam
condenser is bypassed to the con-
denser
31 YEARS OF
COLLABORATION
the same time to support GT opera- plant control system adjusts gas-tur- quently, the steam turbine. The ST
tion; hence, plant net output is lower bine output so unit net load matches was back to full load within 50 minutes
than GT output because of the auxil- the target. of the OTSG trip. During this time, the
iary load. GT continued to operate unaffected
Once there is sufficient exhaust Warm start by the steam-plant upset, delivering
heat to vaporize the 19% aqueous approximately 85% of the total plant
ammonia, the reagent is injected A warm start proceeds more quickly capacity.
into the OTG to react with the SCR than a cold start because water chem-
catalyst and reduce stack emissions istry typically is closer to being in-spec. Cold start with ST trip,
to permitted levels. A tempering-air The primary constraint is the time to
fan starts to prevent overheating of warm the OTSG (and the significant load changes
the SCR catalyst. catalyst mass within). Steam-turbine The combined cycle entered commer-
The circulating-water and condens- metal temperature is another con- cial operation in late 2016. A typical
er-vacuum pumps, and the auxiliary sideration. Typically, full load can be day’s operation in response to system
boiler, are placed in service to pull achieved within about 70 minutes—or dispatch is illustrated by the timeline
vacuum, sparge the condenser, and about half the time needed to reach below. On this day, the unit also expe-
begin reducing dissolved-oxygen lev- full load on a cold start. rienced an ST trip, and its recovery.
els in the condensate. Additionally, 0632 hours. Cold start, dispatch to
the condensate pumps are used to OTSG trip, restart 19 MW.
recirculate condensate through the 0655. Load increased to 44 MW (sim-
polisher to meet water-chemistry As part of unit testing, the OTSG was ple cycle); steam plant readied for
requirements. tripped manually with the unit at full startup.
Once the recirculating conden- load. Steam-turbine load decayed over 0827. The ST was paralleled and its
sate chemistry is acceptable, and the the next 10 minutes and the generator load increased. Gas-turbine load
OTSG has warmed up to the minimum breaker opened. Steam was bypassed decreased to maintain a steady
required startup temperature, the to the condenser to reduce steam pres- combined-cycle output of 44 MW.
feedwater flow control valve is opened. sure to the point where the steam 1208. Unit load increased to 55 MW.
Feedwater flow gradually ramps up drains could be opened and the OTSG 1325. Steamer tripped, GT went to
and steam production begins. prepared for restart. full load and the unit operated at
When the steam lines are warmed Absent heat removal through the 52 MW.
up and the steam-turbine inlet steam steam system, SCR inlet temperature 1401. ST was paralleled.
conditions are met, the turbine is increased and the tempering-air fan 1408. Unit load returned to 55 MW.
started, paralleled, and loaded. Typi- started automatically to control cata- 1541. Unit load reduced to 53 MW.
cally, it is operated VWO (valves wide lyst temperature. 1727 to 2130. Several load changes
open). The ST follows the GT and the The OTSG was restarted; subse- between 20 and 66 MW to accommo-
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 79
EFFICIENT, FAST-START GENERATION
date system dispatch requirements. faster starting. While the 10-min
2213. GT shutdown initiated. start is critical in offering some ser-
2218. GT offline. vices—such as peaking and non-spin
2219. OTSG trips. reserve—the flexible and resilient
2220. ST offline. attributes of this type of unit remain
when using a gas turbine with a lon-
Wrap-up ger start time.
The bottom line: Combining the
Experience with this unit confirms its capabilities of a 10-min-start GT with
relative ease of operation. Startups an OTSG results in a unit that can
and shutdowns are straightforward, start quickly, operate in the simple- or
akin to a simple-cycle unit. The abil- combined-cycle mode, and accommo-
ity to make rapid and frequent load date steam-plant upsets by allowing
changes without having to manage the GT to produce power while the
drum water levels eases the burden steam turbine is restored to operation.
on the operator. This is an optimal mix of capabilities
Further, the ability to effectively to address today’s dynamic electricity
separate the steam plant from the demands. ccj
gas turbine provides both operational
flexibility and the capability to keep a About the author
significant part of the plant’s generat-
ing capacity in service where other Dave Tateosian, PE, principal, Clean
combined cycles might have lost all Power Consulting Partners, was the
their generating capacity because of owner’s project manager, as well The authoritative
a steam-plant trip cascading into a as construction and commissioning information resource for
unit trip. manager during the latter stages owner/operators of
Although the plant performance of the project. He acknowledges the
metrics presented above are for a assistance of the Pasadena Water &
gas-turbine-based
specific site and equipment arrange- Power plant staff—in particular, Rob- peaking, cogen, and
ment, the overall conclusions hold ert Picou—in the preparation of this combined-cycle plants.
true—in general. Today many aero article. GE, ARB, POWER Engineers,
and some frame gas turbines offer and Stantec are recognized for their Subscribe via the Internet, access:
10-min-start capability—some even contributions to the project’s success. www.ccj-online.com/subscribe
205
Turbine load, MW
20
195
185
BEFORE AFTER
175
10
165
155
145 0
Jan Jun Jan Jun
1. Gas-turbine combustor upgrade resulted in a desired gain in megawatt output (left), but also reduced significantly
the NOx levels entering the SCR (right)
100 10.0
Relative catalyst activity, %
150
100
20
9 ppm inlet NOx 25 ppm inlet NOx
2 ppm ammonia slip 5 ppm ammonia slip
30
30 ppm inlet NOx
5 ppm ammonia slip
40 25 ppm inlet NOx
10 ppm ammonia slip
4. Expected design life of the catalyst is around 9 ppm inlet NOx
13 years with the upgrade; however, actual mea- 50 5 ppm ammonia slip
surements showed no change to the SCR inlet Operable, conventional design Common design request
NOx levels, which should extend catalyst life to
Operable, high risk/cost design Commercial operating plant
about 17.5 years
Inoperable for single bed design
increase in engine NOx from 9 to 10.4
ppm and higher exhaust flows impair 5. Advanced G and H machines result in NOx levels to the SCR as much as five
catalyst life, but because the actual times that of earlier models; single-bed designs don’t provide the catalyst volumes
operating data showed no change in necessary to achieve similar stack outlet NOx levels at reasonable slip levels
gas-turbine NOx levels, the minimum
catalyst-activity requirement did not typical at 30-50% load, because of the made of stainless-steel tubing within
increase as much as anticipated. corresponding changes in mass flow, the HRSG housing which allows you
For advanced G and H machines, temperature, and mixing.” to periodically take 2-D distribution-
the news isn’t so good. Toback stated, Environex specialists believe owner/ grid measurements for NOx and NH3
“We’re being asked to achieve the same operators of G- and H-class machines and more accurately tune the AIG
2 ppm NOx and ammonia-slip levels will have problems because vendors distribution valves.
(typical of the toughest permits) even are supplying SCRs with inadequate Such capability nominally adds
though these machines have five times catalyst volumes. It’s also important about $50,000 to the budget, a sum
the turbine-exit NOx levels.” Plus, they to consider adding a permanent grid that looks paltry compared to the
likely will be required to cycle and
operate at less than design output for Load level % of rated load 100 75 50 25 15
significant operating hours over their
lifetimes. Ambient temperature F 73 73 73 73 73
Fig 5 indicates that for these per- Power output MW 168 125 83 41 24
formance specifications, you’ll either Exhaust flow million lb/hr 3.6 3.2 2.6 2.6 2.6
have to accept high operating and com-
pliance risk at the ragged edge of the Exhaust temperature F 1100 1000 1000 776 684
capabilities of traditional single-bed Turbine exit NOx ppm@15% O2 25 25 45 45 45
SCRs or resort to a more complicated
Turbine exit CO ppm@15% O2 10 10 400 3500 3000
and more expensive SCR design.
When you operate advanced-tech- Stack NOx (90% conversion) ppm@15% O2 2.5 2.5 4.5 4.5 4.5
nology machines at low loads, you tap Stack CO (90% conversion) ppm@15% O2 1 1 40 350 300
out the capabilities of the design (Fig
6). “The ammonia injection grid can’t 6. Low-load operation, such as between 30% and 50% MCR, impairs SCR
handle both the NOx levels at the maxi- and CO catalyst operation (data presented are for a 501F); this impact likely will
mum design output and what would be be more pronounced for the advanced G and H machines
82 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
penalties of non-compliance. The
high NOx conversion requirements
for these systems coupled with low
ammonia-slip limits decrease the tol-
erance for non-ideal ammonia-to-NOx
distribution. You should expect this to
increase the required frequency for
ammonia-grid tuning.
Duct burners, of course, are anoth-
er source of NOx and CO which must
be accounted for through real oper-
ating data. SCR inlet NOx can more
than double at design GT output and
full duct firing and the SCR operating
temperature can climb by 50 to 100 deg
F. Inlet CO, meanwhile can decrease.
During interim periods as duct burn-
ers come up to full capacity, or remain
at part load, NOx and CO emissions
can be quite variable. These impacts
can be quite striking if your unit was
designed for baseload operation.
Generally, Toback concludes,
increases in exhaust flow to the SCR
impairs catalyst life, while decreases in
SCR inlet NOx and CO emissions and
increasing SCR operating tempera-
ture extend it. If your machines are
no longer operating the way the SCR
was designed, it’s time to consider a
program to acquire the operating data
needed for optimizing the SCR process
for new conditions. ccj
The authoritative
information resource for
owner/operators of
gas-turbine-based
peaking, cogen, and
combined-cycle plants.
Subscribe via the Internet, access:
www.ccj-online.com/subscribe
N
atural-gas fuel composition
has considerable influence
These four issues, which Turbine
Logic routinely observes when per-
Effects of fuel composition
on gas-turbine emissions forming root cause analyses, pose on operability
and operability. This might risks to gas turbines and are closely The operability concerns described
not have been a concern to you previ- tied to operating conditions and fuel below apply mostly to dry-low-NOx/
ously, but the possible impacts on your composition. dry-low-emissions/ultra-low-emissions
engines of increasing reliance on non- Before discussing the impacts of fuel (DLN/DLE/ULN) systems. They are
traditional pipeline gas—in particular, variability on gas turbines, it is impor- much more prone to these issues than
shale gas, but also LNG, and byproduct tant to understand the composition of diffusion systems—most notably com-
fuels from industrial processes—sug- natural gas, which in North America bustion dynamics, which are a product
gests you might want to read on. typically contains 85% or more of of combustor design and the effort to
Even if you have “good gas,” be methane. The next most common con- keep NOx emissions as low as possible.
aware that the negative impacts of stituent is ethane at about 7% or less, Diffusion systems do experience some
gas-constituent variability can be mag- followed by propane at about 1.5% or dynamics issues near blowout, but they
nified by the high firing temperatures less. Other components include other can be avoided by operating with a
of today’s most advanced gas turbines. higher hydrocarbons, nitrogen, carbon sufficient blowout margin.
Reason is that these machines must dioxide, and hydrogen. From an oper- Blowout. One of the biggest factors
“work harder” to achieve low-NOx ability point of view, it is convenient impacting flame blowout—also known
emissions and thus have fewer “knobs” to divide the fuel constituents into as blowoff or lean blowout (LBO)—is
to mitigate fuel-composition impacts. three buckets: higher hydrocarbons, the flame speed of the different fuel
The Wobbe and Modified Wobbe hydrogen, and diluents. mixtures. Flame speed is the speed
indices are two standard properties As previously mentioned, the Wobbe at which the flame moves through the
used in practice to determine the Index and Modified Wobbe Index both reactants during combustion. Hydro-
effects of fuel variability. But they describe the effect of fuel composition gen addition has particularly signifi-
only indicate the changes in heating on fuel heating value, with the Modi- cant impacts on increasing blowout
value and usually cannot describe fied Wobbe Index also accounting for margin because of its much higher
how changing fuel composition will fuel temperature. In addition to Wobbe flame speed than methane.
affect emissions and some potentially Index recommendations, OEMs typi- Propane and ethane also have
damaging operability issues. cally include a fuel specification for higher flame speeds, but the effect is
Aside from NOx and CO emissions, their gas turbines on levels of higher much less significant than hydrogen.
there are four operability issues of hydrocarbons and hydrogen. By oper- By contrast, diluents (particularly
importance to plant personnel. They are: ating within these recommendations, CO2) reduce blowout margins as they
n Blowout, or when the flame physi- operators generally can avoid some act to reduce the fuel’s flame speed.
cally exits the combustor; also of the operational issues mentioned Takeaway 1: Increases in diluents
referred to as blowoff. earlier. However, the combustion- pose the greatest blowout risk.
n Flashback, or when the flame moves dynamics issue is particularly sensitive Flashback. As previously men-
upstream into premixing sections and difficult and is an issue that must tioned, the presence of hydrogen
not designed to withstand high be actively monitored and managed and higher hydrocarbons can move
temperatures. by operators. a flame upstream into premixing
n Combustion dynamics, or the dam- There is a relationship between passages. Swirlers, fuel lances, and
aging pressure oscillations associ- some of these operability issues and premixing passages are not designed
ated with oscillations in the combus- Wobbe Index—for example, higher to withstand the high temperatures
tion heat release. ethane and propane contents in fuel that would occur with a flame in the
n Autoignition, or the spontaneous leads to a higher fuel heating value, premixing section and can quickly
ignition of a reactive mixture of fuel which also increases autoignition risks. sustain damage.
and air in the premixing section Nonetheless, two fuels with the same In some events, this hardware
of the combustion chamber. The Wobbe can have substantially differ- may liberate and travel downstream
effects of autoignition and flashback ent blowout, flashback, combustion- through the power turbine, causing
are the same, but the underlying dynamics, and autoignition tendencies. catastrophic damage. Loosely speak-
reasons and fuel sensitivities are Thus, Wobbe Index alone cannot be ing, flashback can be thought of as the
completely different. used to ensure safe, reliable operation. “opposite” of blowout; for this reason,
84 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
the H2 level limits in DLN system fuel larly difficult to predict. For example, Combustion dynamics pose a direct
specs are set by flashback margin. while increasing H2 levels always will threat to combustion liners, transi-
Takeaway 2: Increases in hydrogen decrease flashback margin, combus- tion pieces, and cross-fire tubes. If the
content pose greatest flashback risk. tion-dynamics amplitude can either combustion-dynamics amplitudes are
Combustion dynamics. Fuel increase or decrease, depending upon severe, liberation of these parts may
composition directly affects combus- other operating conditions. occur, with hardware travelling down-
tion dynamics. However, in contrast to Takeaway 3: Changes in fuel com- stream through the power turbine.
other operability concerns, the effect position may decrease combustion Combustion instabilities can also lead
is non-monotonic with operational dynamics, increase combustion dynam- to blowout and flashback.
parameters which make it particu- ics, or have no effect at all. Because of the sensitivity of combus-
2000 13
12 Propane, %
30
1000 11
Autoignition time, millisec
900 25
800 10
NOx emissions, ppm
700 Propane, % 20
600 0 9
500 15
5 8
400 10 10
15 7
300 20 5
6
200 0
5
Source: NOx correlation taken from “Impact
of Ethane, Propane, and Diluent Content in Natural
Source: “Ignition Delay Characteristics of Methane Fuels,” 4 Gas on the Performance of a Commercial Microturbine
by L J Spadaccini and M B Colket III Generator, by R L Hack and V G McDonell”
100 3
0 5 10 15 20 0 5 10 15 20 25 30
Ethane, % Ethane, %
2. How NOx emissions are impacted by the amount
1. Autoignition time varies with the amount of methane, of ethane and propane in natural-gas fuel. Tests of four
ethane, and propane in natural gas. Operating conditions different fuel blends were conducted using a Capstone
that underpin the data presented here are pressure, 30 atm; C-60 MTG gas turbine operating at a pressure of about
gas temperature, 800K; equivalence ratio, 0.5 4 atm and a turbine exhaust temperature of 1175F
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 85
SAVE THE DATE
tion dynamics to the details of the flame (especially when coupled with the high- Takeaway 5: The lower a gas tur-
configuration inside the combustor, er compressor discharge temperatures bine’s NOx emissions, the greater the
dynamics are sensitive to all changes of aeroderivatives) pose the greatest impact of fuel composition on those
in fuel composition—that is, changes autoignition risk. emissions.
in higher-hydrocarbon, hydrogen, or Nitrogen oxides. There are two Carbon monoxide. The effects
diluent content. Note: In this case, the main NOx formation pathways: of fuel composition on CO production
risk is changes rather than increase. n NOx produced in the flame, which are largely controlled by whether it
The Turbine Logic combustion dynam- generally is a few ppm and heavily moves the system closer to, or farther
ics monitoring group has observed influenced by fuel composition. from, lean blowout. If the unit is near
increased challenges with dynamics, n NOx produced post-flame, which LBO, CO emissions typically already
and the need for more frequent tuning really only depends on flame tem- are high, but can still be raised sig-
because of gas composition issues. perature. nificantly by the presence of higher
Autoignition. Hydrogen and high- Thus fuel composition influences on hydrocarbons and hydrogen in the fuel.
er hydrocarbons also significantly NOx emissions are somewhat depen- Away from LBO, CO emissions may
decrease autoignition temperature and dent on the nominal NOx emissions of still rise with the addition of higher
times, leading to increased autoigni- the gas turbine. Assuming the firing hydrocarbons and hydrogen, but the
tion risks. While symptomatically temperature stays fixed as fuel compo- effect is quite small.
similar to flashback, the physics of sition varies, for units with relatively Takeaway 6: Similar to blowout,
autoignition is different. In this case, high NOx emissions (nominally 15 increased diluent content poses the
if the autoignition time of the fuel ppm and higher), NOx production is greatest CO risk.
mixture falls below its residence time dictated mostly by the firing tempera-
in the premixing tubes, the fuel mix- ture and is largely insensitive to fuel Recommendations
ture may spontaneously ignite in the composition.
premixing zone. On the other hand, units that have A fuel treatment system will mitigate
Similar to flashback, autoignition fairly low NOx emissions (less than 5 the fuel-variability effects on each
can damage premixing passages, swirl- ppm) will see a significant effect from of the operability issues discussed
ers, and fuel lances. As with any of changes in fuel composition. Data sug- above. These systems are equipped
these other operability issues, libera- gest that NOx concentrations may even for removing solid particulates and
tion of any of these parts poses a threat double with changes in fuel composi- higher hydrocarbons. The latter is
to the power turbine. Fig 1 shows the tion for such low-NOx systems. Fig 2 accomplished by condensation and
how quickly autoignition times decrease shows how much NOx production can liquid removal.
with increasing amounts of ethane and increase, in the low-NOx case, with Most OEMs also recommend some
propane in natural-gas fuel. increasing amounts of ethane and degree of fuel superheating before use
Takeaway 4: Higher hydrocarbons propane in natural gas. in a gas turbine to ensure that no fuel
86 COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017
TURBınE ınSULATıOn AT ıTS FınEST
condenses before reaching the fuel In the authors’ experience, every If you continue to have combustion-
nozzles. Condensed fuel can cause engine monitored by Turbine Logic dynamics issues while keeping NOx
significant autoignition issues. Even has had multiple dynamics excursions concentrations within regulatory lim-
with a good fuel treatment system, exceeding thresholds as the ambient its, consider installing an auto-tuning
small concentrations of liquid hydro- temperature and load varied. The need system. It monitors dynamics and
carbons from the fuel gas remain a for shorter tuning intervals only can emissions and has control logic to mini-
risk when liquids are entrained from be confirmed by CDMS. mize emissions while keeping combus-
the liquid knockouts. This may occur Several options are available to tion dynamics within acceptable limits
with higher hydrocarbons, because control loud combustion instabili- to prevent hardware damage.
the knockouts fill more quickly and ties, and all are used by manual- or Auto-tuning systems typically
require more frequent draining than auto-tuning systems. These include have the ability to regulate several
experience might dictate. varying the fuel temperature within operational parameters— including
Along with Wobbe Index recommen- the OEM spec, altering the fuel stag- firing temperature, fuel splits, and
dations, OEMs issue fuel specifications ing, increasing the non-premix pilot even fuel-split schedules. When either
for their units. They are designed to fuel, varying the amount of inlet air dynamics or an emissions excursion
accommodate blowout and flashback chilling, and varying the amount of occurs, auto-tuning systems step in
margins, and those phenomena should steam/water injection. De-rating is and nudge these parameters to return
not occur when operating within the the last resort. the gas turbine to safe and compli-
specs. However, even when operat- To complicate things, because of ant operation. While seasonal tunes
ing within the recommended specs, the non-monotonic nature of combus- remain a good idea, and sometimes
combustion dynamics and emissions tion dynamics, a change in fuel com- a necessity, the auto-tuning system
may be impacted by changes in fuel position can alter the unit’s response will handle the day-to-day changes
composition. to each of these operational changes. that gas composition variability may
The greatest operational risk that Since combustion dynamics don’t have introduce. ccj
cannot be managed by staying with a one-to-one relationship for different
OEM fuel guidelines is combustion operating conditions, installation of a
dynamics. Turbine Logic’s experts CDMS can provide great insight into
strongly recommend users have a com- how your units respond to different
bustion dynamics monitoring system operational changes. CDM systems
(CDMS) to warn of impending issues, provide nearly instantaneous feed-
and also have protocols in place for back and will facilitate the building
ensuring sensors are healthy; plus, of a knowledge base around how your
appropriate notifications if levels units behave regarding combustion
exceed alarms. dynamics.
COMBINED CYCLE JOURNAL, Number 54, Third Quarter 2017 87
HEAT-RECOVERY STEAM GENERATORS
Welds joining
shell-to-shell
and
head-to-shell
Nozzle condition
LM2500
LM5000
LM6000
LMS100
GG4/FT4
Aeroderivative Gas Turbine Support, Inc.
phone: (561) 994-0000
fax: (561) 994-3600
email: sales@agtsi.com
1141 S. Rogers Circle, Suite 11 Boca Raton, FL 33487
Visit our newly redesigned website www.agtsi.com
Increase Efficiency
Increase Power
Invest To Save!
Specializing in GT
Inlet Air Filtration.
HRSG Forum with Bob Anderson has named CCJ the organization’s official publication because it focuses
exclusively on the information needs of headquarters and deck-plates personnel responsible for the design,
specification, operation, and maintenance of cogeneration and combined-cycle plants powered by gas turbines.
BEST PRACTICES. User advocates HRSG Forum and CCJ announce the 2018 HRSG Best Practices Awards
program for plant owners and operators. Submit your entries online at www.ccj-online.com/hrsg-best-practices
before Dec 29, 2017. Judging will be by the steering committee of the HRSG Forum. Successful candidates will be
recognized at the Second Annual Meeting in Houston, March 5 - 7, 2018.
George H. Bodman
President/Technical Advisor
PO. Box 5758 Kingwood, TX 77325-5758 Visit Conval.com and click
Office: 1-800-286-6069 E-mail: blrclgdr@aol.com on the NEWS SPOTLIGHT
to watch our new video!
Office: (281) 359-4006 Fax: (281) 359-4225
Products and services from over 100 companies support new unit
construction, retrofit and maintenance activities at existing facilities, and plant
operations. Solutions span gas and steam turbines, HRSGs, pumps, valves,
piping, cooling towers, condensers, etc
ABOUT QR CODES
A wealth of data in the palm of your hand. Visit your App Store and download one
of our suggested QR readers for your smartphone or tablet to access enhanced
digital content and information.
Recommended, free, and easy-to-use apps:
■ AT&T Code Scanner
■ QR Reader for iPhone
■ QR Reader for Android
Monitoring,
Texas Bearing Services valve solutions for severe
Manufactures and repairs service applications. Com-
on-demand at NO
offering an array of ancillary
Turbine Technology Services services which include test-
(TTS)
COST Wide range of expert engi-
ing/repair of circuit boards,
parts, DCS troubleshooting, Dos support,
Access the complete course on neering and consulting ser- HMI upgrades/backup and field-based
vices, conversion, modifica- mechanical and controls training.
generator monitoring, inspection, tion and upgrade services,
and maintenance, conducted by GT installation and reapplica- Young & Franklin
Clyde Maughan, president, tion services, and design and implemen- Premier fuel control supplier
Maughan Generator Consultants tation of complete turbine management for combustion turbines for
LLC, at www.ccj-online.com/on- systems. both long-term hydraulic
solutions and, more recently,
screen. The program is divided Universal AET innovative all-electric
into the following manageable Designs, procures, and manu- controls solutions. Product scope sup-
one-hour segments: factures OEM and retrofit inlet ports natural gas, liquid, syngas, and
and exhaust systems includ- alternative fuels as well as providing
Impact of design on reliability ing filter houses, inlet duct/ air controls to provide proper fuel to air
Problems relating to operation silencers, enclosure doors, mixtures.
diffusers, plenums, expansion joints, tran-
Failure modes and root causes sitions, exhaust ducts/stacks, exhaust Zokman Products
baffle silencers, and stack dampers. Distributor of ZOK27 and
Monitoring capability and ZOKmx gas-turbine com-
limitations Universal Plant Services pressor cleaning detergents.
Inspection basic principles Specializes in the mainte- ZOK27 is a single cleaner
nance, repair, and overhaul and inhibitor in one that
Test options and risks of gas and steam turbines, cleans and protects the engine—and also
centrifugal and reciprocat- inhibits corrosion. ZOKmx is a power
Maintenance basic approaches ing compressors, as well cleaner formulated to replace solvents
as all rotating equipment, with qualified providing exceptional cleaning without
www.ccj-online.com/onscreen millwright and field machining special- the health and environmental risks asso-
ists. ciated with solvents.
Corporate Headquarters
155 Franklin Turnpike
Waldwick, NJ 07463
GROOME
(800) 505-6100 INDUSTRIAL
www.groomeindustrial.com SERVICE GROUP
FIND A VENDOR, FIX A PLANT