0-Esquema de Conjunto de Purga de Vapor

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Kit de Drenagem com Purgadores de Balde Investido (Roscado) : Spirax Sarco Brasil

Spirax Sarco Brasil

Page 1 of 3
Tel: (55) 11 4615 9000 Fax: (55) 11 4615 9007 Marketing@br.spiraxsarco.com http://www.SpiraxSarco.com/br/

Related Content
Inverted Bucket Steam Trap Tutorial
Study the subject of inverted bucket steam trapping in greater depth. This link will take you to our International Website

Voc est aqui: Home Aplicaes e Indstrias Exemplos de Solues Tpicas Inverted Bucket Steam Trap Set (Screwed)

Purgadores

Purgadores Mecnicos

Purgadores Mecnicos
Kit de Drenagem com Purgadores de Balde Investido (Roscado)
Os componentes necessrios em uma estao drenagem com purgadores de balde invertido Component Descriptions Tables of Parts

Feature
CAD - Steam Traps
View CAD drawings for our Steam Traps This link will take you to our International Website

Component Descriptions
Part Component
1 2 3 4 5 6 7 Isolation Valve Strainer Spiratec Sensor Chamber Inverted Bucket Steam Trap Sight Glass Check Valve Isolation Valve

Function
to isolate the trap set from the supply steam to protect the trap from detritus to monitor the trap condition to discharge condensate correctly to observe the condensate condition to prevent reverse flow to isolate the trap set from the condensate system

http://www.spiraxsarco.com/br/applications/examples/steam-trapping/mechanical-steam-traps/inverted-b... 20-10-2010

Kit de Drenagem com Purgadores de Balde Investido (Roscado) : Spirax Sarco Brasil
Table of Parts
Part
1, 5

Page 2 of 3

Component
Isolating Valve Globe Type Piston Type Ball Type

Bronze
HV3

Cast iron

SG iron

Steel
A3S RP31 M10

Stainless steel

Product details
HV3 Stop Valves or Bellows Sealed Stop Valves Piston Valves

M10 Fig 36 ST163 SIB30, SIB45, UIB30

Ball Valves Strainers & Filters Steam Trap Performance Monitoring Inverted Bucket Steam Traps or Swivel Connectors & Traps

2 2 2

Strainer Spiratec Sensor Chamber Inverted Bucket Steam Trap

Fig 3

Fig 33

Fig 37SG

Fig 34 ST143

HM , 200 Series, SF Series Single Window, Double Window, Sight Check LCV1

HM34 , SCA Series

Sight Glass

Sight Glasses

Check Valve

LCV2

Check Valves

http://www.spiraxsarco.com/br/applications/examples/steam-trapping/mechanical-steam-traps/inverted-b... 20-10-2010

Kit de Drenagem com Purgadores de Balde Investido (Roscado) :shown to indicate position. * Items 3 and 5 are not normally installed together - both are Spirax Sarco Brasil
Separate Check Valve not required. Separate Strainers not required.

Page 3 of 3

What do I do now?
Spirax Sarco have experienced engineers available to offer advice on these applications: Let us help you size and select these products Arrange a visit to your plant by Spirax Sarco Ask us a question about this application

Fale Conosco

http://www.spiraxsarco.com/br/applications/examples/steam-trapping/mechanical-steam-traps/inverted-b... 20-10-2010

You might also like