Professional Documents
Culture Documents
0-Esquema de Conjunto de Purga de Vapor
0-Esquema de Conjunto de Purga de Vapor
0-Esquema de Conjunto de Purga de Vapor
Page 1 of 3
Tel: (55) 11 4615 9000 Fax: (55) 11 4615 9007 Marketing@br.spiraxsarco.com http://www.SpiraxSarco.com/br/
Related Content
Inverted Bucket Steam Trap Tutorial
Study the subject of inverted bucket steam trapping in greater depth. This link will take you to our International Website
Voc est aqui: Home Aplicaes e Indstrias Exemplos de Solues Tpicas Inverted Bucket Steam Trap Set (Screwed)
Purgadores
Purgadores Mecnicos
Purgadores Mecnicos
Kit de Drenagem com Purgadores de Balde Investido (Roscado)
Os componentes necessrios em uma estao drenagem com purgadores de balde invertido Component Descriptions Tables of Parts
Feature
CAD - Steam Traps
View CAD drawings for our Steam Traps This link will take you to our International Website
Component Descriptions
Part Component
1 2 3 4 5 6 7 Isolation Valve Strainer Spiratec Sensor Chamber Inverted Bucket Steam Trap Sight Glass Check Valve Isolation Valve
Function
to isolate the trap set from the supply steam to protect the trap from detritus to monitor the trap condition to discharge condensate correctly to observe the condensate condition to prevent reverse flow to isolate the trap set from the condensate system
http://www.spiraxsarco.com/br/applications/examples/steam-trapping/mechanical-steam-traps/inverted-b... 20-10-2010
Kit de Drenagem com Purgadores de Balde Investido (Roscado) : Spirax Sarco Brasil
Table of Parts
Part
1, 5
Page 2 of 3
Component
Isolating Valve Globe Type Piston Type Ball Type
Bronze
HV3
Cast iron
SG iron
Steel
A3S RP31 M10
Stainless steel
Product details
HV3 Stop Valves or Bellows Sealed Stop Valves Piston Valves
Ball Valves Strainers & Filters Steam Trap Performance Monitoring Inverted Bucket Steam Traps or Swivel Connectors & Traps
2 2 2
Fig 3
Fig 33
Fig 37SG
Fig 34 ST143
HM , 200 Series, SF Series Single Window, Double Window, Sight Check LCV1
Sight Glass
Sight Glasses
Check Valve
LCV2
Check Valves
http://www.spiraxsarco.com/br/applications/examples/steam-trapping/mechanical-steam-traps/inverted-b... 20-10-2010
Kit de Drenagem com Purgadores de Balde Investido (Roscado) :shown to indicate position. * Items 3 and 5 are not normally installed together - both are Spirax Sarco Brasil
Separate Check Valve not required. Separate Strainers not required.
Page 3 of 3
What do I do now?
Spirax Sarco have experienced engineers available to offer advice on these applications: Let us help you size and select these products Arrange a visit to your plant by Spirax Sarco Ask us a question about this application
Fale Conosco
http://www.spiraxsarco.com/br/applications/examples/steam-trapping/mechanical-steam-traps/inverted-b... 20-10-2010