Professional Documents
Culture Documents
Eberspacher Heater D3LCC Workshop Manual
Eberspacher Heater D3LCC Workshop Manual
J. Eberspacher
GmbH & Co.
Eberspacherstr. 24
D-73730 Esslingen
Telefon (zentral)
(0711) 939-00
Telefax
(0711) 939-0500
www. ebe rspaecher. de
Contents Page
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
~=====
List of Parts
Main fuse 12 V - 25 A 10 Fresh air blower A Exhaust gas
24 V - 15 A 11 Electric motor 8 Fuel
2 Fuse 5 A 12 Combustion air silencer F Fresh air
3 Timer 13 Fuel connection v Combustion air
4 Electronic control unit 14 Flange gasket w Hot air
5 Combustion air blower impeller 15 Combustion chamber
6 Glow plug 16 Outer shell
7 Overheating sensor 17 Exhaust gas pipe
8 Flame sensor 18 Metering pump
9 Heat exchanger 19 Pot-type strainer, installed in metering pump
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Starting process
Control and safety features
After approximately 35 seconds, fuel delivery will take
place. The fuel/air mixture will ignite. The blower and the The flame is monitored by the flame sensor, and the maxi-
fuel delivery will be increased progressively. After flame mum permissible operating temperature by the overheating
detection and stabilization of combustion, the glow plug will sensor. Both these features influence the control unit. which
be switched off. switches the heater off in the event of a malfunction.
Rapid heating up of the heater takes place on the POWER If the voltage (according to Model) drops below approxi-
setting with maximum heat flow until the heat exchanger mately 10.5 or 21 volts, or rises above approximately 15.9
has reached its operating temperature. or 31.8 volts, malfunction shutoff will take place.
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Technical Data
in operation
Weight approx. 6 kg
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Check values
Resistance values
2500.--.----.-..,.....---r----.---.-----.~-.---~ 2500~-~-~-~-~~-~-~-~-~
In ©
E 1750-+--"-+---4--+--~~~'--+------4----1--~ E 1750 +-'--+-:---.;t--..;__,..~---,-;i-'---~'--~---t---'---t-~rl
..c ..c
0 0
-;1soo+c---;--,,+-:--"-l~-7t~.,..;-.;_;_--+":~+-'"-'--l1---+~-1 -; 1500 -+-----~-,r-,-,..,--,-r-:;;.....--;r-~...,---.~---+.....,,..---t-~__,
(.) (.)
c
~ 1250+-~~...,-.j~+;-:-'-'-~,....,..-,,,f-_,_.1--~~...,.,.+......,.,,,._,,..i ~ 1250
£If)
500-+--...__--t--L--~-"'-'------'+-----'-----+--~ 500-+-~-+-'-+-~t----if----..,--t----+--+---t-~__,
-40 -20 0 20 40 -40 0 50 100 150 200 250 300 350 400
Temperature (°C) Temperature (0 C)
• Corroded contacts.
• Check fuses.
• When changing over to Winter mode: is summer diesel fuel still in the line?
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Interrogating the fault memory in the control unit Locking the control unit
with the timer (modular clock)
Overheating
The electronic control unit can store up to 5 malfunctions,
which can then be read out and displayed with the timer
In case of excess temperature at the heat exchanger
(modular clock). The present malfunction is written into
(error 013, shown in display F 15), the control unit is
memory' location F 1. Previous malfunctions are written into
locked.
memory locations F 2 - F 5.
Canceling the control unit interlock,
Interrogating the fault memory
erasing the fault memory.
Press the l!!I key - heater is switched on - then
Depress the@] key and within 2 seconds Condition: The electrical connection from terminal 15
Press the Ii) key - the present malfunction will be displayed, (ignition) to the timer module (12-pin connector,
for example AF 64. terminal jack 10) is in place.
Pressing the II key and the II key will call up the stored Press the flll key - the present malfunction F 15 or F 50 will
malfunctions (max. 5 malfunctions). be displayed - then
Depress the @]key and within 2 seconds
Press the Iii key. The timer (modular clock) has now entered
The fault code, description of malfunction and comments/
the "Interrogate Fault memory" routine.
remedy are described on page 8 to page 10.
Continue operation:
Switch ignition off (Terminal 15).
Press the@] key and the Iii key simultaneously; in addition,
switch the ignition on (Terminal 15) and wait until the follow-
ing appears in the display:
Blinking readout,
Please note!
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Before testing
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
000 no malfunction
009 TRS shut-off TRS disconnection by signal change from ( +) to (-) at the
control unit connection, compartment 10 (D+) or positive signal
to control unit connection, compartment 12 {HA+).
012 Overheating Check connection from control unit to overheating sensor for
continuity. For overheating values, see Graph on page 5.
Check heating air ducts for obstruction; clear obstruction if
necessary.
013 Heat exchanger overtemperature Flame sensor signals temperature at heat exchanger> 340 °C.
Resistance value at flame sensor > 2270 Q
Overheating sensor faulty.
For flame sensor values, see Graph on page 5.
015 Heat exchanger overtemperature Control unit lock out - shutdown due to fault.
Excessive occurrence of overheating Excessive temperature at heat exchanger (fault code 013)
Cause of overheating: heating air ducts obstructed; clear
obstruction if necessary.
Defeat control unit lock-out by clearing fault memory with the
timerv, the diagnostic unit or PC
020 Open circuit or short circuit at glow plug Check glow plug, replace if necessary. Setpoint value:
approx. 0,6 or 2 Q
Check connection from control unit Compartment 6 and 9 to
glow plug for continuity. If OK--> replace control unit.
Check control unit Compartment 9 as far as glow plug.
Check glow plug for short-circuit of filament, replace if
necessary. If OK--> replace control unit.
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Fault
Description of fault Comment I Remedy
Code
025 Diagnostic output short-circuit Check connection of control unit Compartment 4 to diagnostic
connector plug for short-circuit to positive.
033 Burner motor or governor defective; RPM deviation > ± 10 % of setpoint value for > 30 seconds.
RPM deviation For check values, see page 5.
• RPM too low: blower obstructed.
Check blower free-running, if necessary remove foreign matter.
RPM still too low--> replace blower.
Check motor supply lead (1 br/1 sw) and control unit output
for short-circuit--> replace blower or control unit.
• RPM too high: solenoid in blower impeller defective of
absent--> replace blower.
RPM sensor in control unit defective-> replace control unit.
047 Metering pump short-circuit Check connection of control unit Compartment 3 to metering
pump for short-circuit--> check metering pump, replace if
necessary.
048 Metering pump open circuit Check connection of control unit Compartment 3 to metering
pump for open circuit-> check metering pump, replace if
necessary.
Check negative supply of metering pump (1 br) to ground.
051 Flame present when switched on After 15 minutes cold air blowing
Resistance value at flame sensor > 57 °C ( 1220 .Q)
For flame sensor values, see Graph page 5.
052 No start, sat ety time overshoot No flame detected in start phase.
Flame sensor value< 100 °C (1380 Q). Check flame sensor,
replace if necessary. For flame sensor values see Graph page 5.
Check fuel supply, glow plug, exhaust gas and combustion
air ducts.
053 Flame abort on Power setting I Start Heater has fired (flame detected) and signals flame abort in
054 Flame abort on High setting a setting or during Start. Check fuel delivery and fuel supply.
055 Flame abort on Medium setting Check exhaust gas and combustion air ducts.
056 Flame abort on Low setting If combustion OK--> check flame sensor, replace if necessary.
For flame sensor values, see Graph page 5.
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Fault code
Description of fault Comment/Remedy
060 External temperature control sensor Temperature control sensor signals temperature value outside
open circuit control range. Check connecting leads 0.5 gr and 0.5 br/ws.
061 External temperature control sensor Resistance value between 8 and 13 > 2800 Q (open circuit)
short-circuit Resistance value between 8 and 13 < 280 Q (short-circuit)
Temperature sensor values see Graph on page 5.
062 Setpoint value pot. open circuit Potentiometer of operating control signals setpoint value outside
063 Setpoint value pot. short-circuit control range. Check connecting leads.
Resistance value between 7 and 13 > 2800 Q (open circuit)
Resistance value between 7 and 13 < 280 Q (short-circuit)
Standard values: 1740 Q - 2180 Q (±80 Q)
064 Flame sensor open circuit Flame sensor signals temperature value outside measuring
065 Flame sensor short-circuit range. Check connecting leads.
Resistance value> 3200 Q (open circuit)
Resistance value< 200 Q (short-circuit)
Flame sensor values, see Graph page 5.
071 Overheating sensor open circuit Overheating sensor signals temperature value outside
072 Overheating sensor short-circuit measuring range. Check connecting lead.
Resistance value> 3200 Q (open circuit)
Resistance value< 200 Q (short-circuit)
Overheating sensor values, see Graph page 5.
090 Watchdog - Reset (internal malfunction I Reset) Internal malfunction in microprocessor/memory - t replace
control unit.
091 External interference voltage Control unit malfunction due to interference voltages from
(external malfunction I Reset) vehicle electrical system.
Possible causes:
Flat battery, charger -+ eliminate interference voltages.
092 Control unit defect {ROM fault} Internal fault in microprocessor/memory detected - t
093 Control unit defect {RAM fault) replace control unit.
094 Control unit defect {EEPROM fault)
096 Control unit defective Replace control unit or use external temperature sensor.
internal temperature sensor defective
10
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Model
20 1749 01
20 1750 01
25 1906 01 Glow plug
25 1907 01 negative pulsed
25 1912 01
25 1913 01
rt0,5
ge0,5
gr0,5
a)
I I 1 grrt0,5
I I J brws0,5
I I I
I I I
rt4,0 I I I
l l
! I I
I I I
I I I
I I I
I I I
I I I
I I I
I I I
I I L____ ~li0,5_ _ _ _ b1}
I___ Ct- __ ~--=---=---=-----=--ws~ ~:!-_-=_~ :~
Diode
b)
br4,0
11
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Model
20 1762 01
20 176301
Glow plug
25 1967 01
positive pulsed,
25 1968 01
with current regulator
25 1969 01
25 1970 01
rt0,5
ge0,5
I gr0,5
I wsrt0,5
I br0,5
a)
I
I blws0,5
I grrt0,5
I]~~~
I rt 1.0
~ii
~1·._T.
List of parts
tJ br4,0
mode
1965 601 b
12
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Circuit diagram~ Heater, standard model {see page 15 for operating panel)
Model
20 1767 01
20 1768 01
25 1980 01 Glow plug
25 1981 01 positive pulsed
25 1982 01
25 1983 01
ws2,5
@)
rt 0,5
-fDt
• • ' gnrt 1,0
qe 0,5
qr0,5
Ll3J:~,___b_r~1.0-+--~, wsrt 0,5
br0,5 a)
J blws 0,5
/ qrrt0,5
brws0,5
@)[J @]rn
) rt 1,0
@)~--ii
i~d br4,0
13
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Circuit diagram, Heater, TRS model (see page 15 for operating panel)
Model
20 1767 01
20 176801
25 1980 01 Glow plug
251981 01 positive pulsed
25 1982 01
25 1983 01
ws2,5
U}
N'
.D
rt0,5
-rol- ge0,5
l13;t:~,}--gn~~-~~:~'-t--+---+-----.I
gr0,5
wsrt0.5
br0,5 a)
/ b!ws0,5
~~7 / grrt0,5
/ brws 0,5
c)
I - - - - - - - ----; -~ -----,
I I
I Kl.15 IOGD I
I ~7 o I
I ~ / I
I § o:-"/ >[
@
i[]
'
I 6 6 -~+ 1
rt .0· l
I n n r~~ I
! k~."=~ @) l'.' !
I ~-~--~--~--~--:::__-~_!
List of parts 1976 602 a
14
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
rt 0.5
3.2.5 Timer. rectangular } . .
3.2.6 Timer, miniature } not perm1ss1ble
l
II& 0.5 ) withTRS
3.2.7 Timer, rectangular
~
__!lr_!_~-
aJ tr 0.5 3.2.8 Timer, rectangular
b[irs 0.5 TRS po!entiometer
f(f't 0.5
trn 0.5 3.1.11 Operating control. round
3.1.15 Operating control, miniature, less sensor
~--------+-<Jcj:j~
oe o.5
r-,--y---. rt
i ~ ~]JA7c=="'1
r-------"1 wsrt + battery isolating switch Stop
Disable anti-theft alarm system
l
~ • br Supply negative terminal 31
8)
l!ll't 0.5
tr 0.5
cli~!=! ~ :
blws Diagnostic
--------------+<!~!:!
~ ~I brws Reference signal sensor
~0.5
~----------+<1c1.-1
Ins 0.5 I b) Terminal 15
t~~l~ ~-------~ c) lllumina!ion Terminal 58
d) Connection. diagnostic unit for fault code
output
e) Connection. outside temperature sensor
!} Cable jumper (0.5 br) - omitted with TRS
g) Connection. external heating key (;11
h) Connection. radio module
i) Connection. acknowledgement from
control unit (TRS only)
connection, outside temperature sensor
(not 011 TRS)
rt 0.5 For timer connection, cul lead here
oe o.s
l
~
ll!l't 0.5
a> tr 0.5
bin o.s
~0.5 Cable colours
Ina 0.5
SW black
WS white
rt red
ge yellow
gn green
vi violet
br brown
gr grey
bl blue
lilac
rt 0.5
l
0.5
1T &.5
ftl't 0.5
a) Ir 0.5
bha o.5
~0.5
bMa 0.5
SI 81 84
I
S2 82 86
::::
!th---- --
•yl S3
-----R~Ii]
85
53
I
85 83
lr0.5
bl18 o.s
rt o.s
1------t:L~
I
~_!.5_ _ _ _ _ _ _ _ _
IB oi1ulrnisirnleio
1895 701 c
15
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Rep·
air Instruct·ions
16
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Repair steps
Slacken socket head cap screw and detach cap. Extract plug strainer from the plug socket with pliers.
Blow off plug vent with compressed air (diesel version only).
Caution!
The glow plug connector is live - therefore pull the 14-pin When installing the plug strainer, note position of lug or
plug connector off the control unit. parting line, see Drawing 1 or Drawing 2.
Carefully insert plug strainer to its fullest extent.
Slacken glow plug connector and unscrew glow plug.
For diesel version:
Important! When replacing the glow plug, always use a Passage for plug vent (2 mm dia.) must be unobstructed.
fresh seal washer.
Order No. of seal washer 25 1830 01 01 01
1 Glow plug
3 2 Plug strainer
3 Glow plug
connector
Figure 1
Position of installation of lu strainer with etrol version Position of installation of plug strainer with diesel version
Drawing 1 Drawing 2
17
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
3 Removing I installing electronic control unit 4 Detaching cap, detaching discharge hood,
detaching jacket half
Extract both plug connector housing from the control unit.
Release control unit and withdraw from its guide. Slacken socket-head cap screw and detach cap_
Then, pull off both plug connector housings on the rear of Detach discharge hood with screwdriver.
the control unit Remove body-bound rivets and detach jacket halves_
1 2
- - -
~.~;.~r?~!~~~,~~~~~?.;;=~ 3
Figure 2 Figure 3
Drawing 4
Drawing 3
Drawing 5
18
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Figure 4
Overheating sensor
2 Flame sensor
Release Duo-Clip locking devices with screwdriver and Pull plug connector housing off the control unit. Expose
detach insulating shells. over!1eating sensor cable.
Unscrew two oval head screws and detach overheating
Use fresh locking devices when installing. sensor.
Drawing 6 Drawing 7
19
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
7 Detaching I attaching flame sensor 8 Detaching combustion air blower from the heat
exchanger
Detach top insulating shell.
Preceding operations:
Detach plug connector housing from control unit, expose Detach cap.
flame sensor cable. Detach cable harness.
Detach retaining spring from flame sensor. Detach discharge hood.
Detach jacket halves.
Pull off the plug connector housing of the flame sensor cable
section and the plug connector housing of the overheating
sensor cable section on the control unit.
Unscrew four oval head screws from the blower. Detach
combustion air blower from the heat exchanger.
Renew gasket.
1 2
Figure 5
Drawing 8
20
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
1 Cover
2 Gasket
3 Seal ring
Figure 6
Drawing 9
21
www.butlertechnik.com
Visit www.butlertechnik.com for more technical information & downloads
Pull the fuel line off the heater and insert in a graduated Switch heater on.
measuring glass (20 cm3 size). Fuel delivery commences approximately 25 seconds after
Switch the heater on. switching on. Hold the graduated measuring glass at glow
After 25 seconds, the metering pump will commence to plug height during measurement. After 90 seconds of fuel
deliver the fuel. delivery, it will shut off automatically.
When fuel emerges uniformly and free bubbles, the fuel line Switch heater off, otherwise restart will take place.
is full and vented. Read off quantity of fuel delivered in the graduated
Switch tile heater off and empty the measuring glass. measuring glass.
Drawing 10
Evaluation
Heater Model B3LC compact B3LP compact D3LC compact D3LP compact
22