Professional Documents
Culture Documents
Autonics PR PRW DC 2wire Series Manual
Autonics PR PRW DC 2wire Series Manual
Autonics PR PRW DC 2wire Series Manual
Cable※3
Failure to follow this instruction may result in fire.
Connections
PRT
3. Do not connect, repair, or inspect the unit while connected to a power source. 0.08mm, Number of cores: 40,
(AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1.25mm)
Failure to follow this instruction may result in fire. Insulator diameter: Ø1mm)
PRWT Ø4, 2-wire, 300mm, M12 connector Ø5, 2-wire, 300mm, M12 connector - Connector connection for standard Connector connection for
4. Check 'Connections' before wiring. DC 2-wire standard
Failure to follow this instruction may result in fire. Case/Nut : Nikel plated Brass, Washer : Nikel plated Iron, Sensing surface : PBT, type model IEC standards model
Materials Brown
Standard cable(Black) : Polyvinyl chloride(PVC), Oil resistant cable(Gray) : Oil resistant Polyvinyl chloride(PVC)
Caution Brown 2 1 2 1 Load +V
Approval Load +V Brown
1. Use the unit within the rated specifications.
PRT: Approx. 84g(Approx. 72g) PRT:Approx. 122g(Approx. 110g) PRT:Approx. 207g(Approx. 170g) PSNT: 3 4 +V 3 4
Failure to follow this instruction may result in fire or product damage. PRT: Approx. 64g(Approx. 52g) Blue
Weight※4 PRWT: Approx. 54g(Approx. 42g) PRWT:Approx. 70g(Approx. 58g) PRWT:Approx. 134g(Approx. 122g) Approx. 92g 0V
2. Use dry cloth to clean the unit, and do not use water or organic solvent. PRWT: Approx. 44g(Approx. 32g) Blue Blue
PRCMT:Approx. 38g(Approx. 26g) PRCMT:Approx. 60g(Approx. 48g) PRCMT:Approx. 154g(Approx.142g) (Approx. 71g)
Load 0V (a)N.O.(Normally Open) Type
Failure to follow this instruction may result in fire. 0V
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, ※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard Brown
impact, or salinity may be present. Brown 2 1 Load +V
sensing target, 1/2 of the sensing distance for the distance. +V 2 1
Failure to follow this instruction may result in fire or explosion. ※2: Before using non-polarity type, check the condition of connected device because residual voltage is 5V. Brown 3 4
4. Do not supply power without load. 3 4 Load +V Blue
※3: Do not pull the Ø3.5mm cable with a tensile strength of 25N, the Ø4mm cable with a tensile strength of 30N or over and the Ø5mm 0V
Failure to follow this instruction may result in fire or product damage. cable with a tensile strength of 50N or over. Blue (b)N.C.(Normally Closed) Type
Load 0V Blue
0V ※②,③ of N.O. type and ③,④ of N.C. type
Ordering Information It may result in fire due to the broken wire. When extending wire, use AWG22 cable or over within 200m.
※4: The weight with packaging and the weight in parentheses is only unit weight. ※①,② are not used terminals. are not used terminals.
※Environment resistance is rated at no freezing or condenstion. ※Load can be wired to any direction. ※No need to consider polarity for non-polarity type of power supply.
P R CMT 12 2 D O U IV No mark Standard cable
Cable type I Standard cable(IEC standards model)
V Oil resistant cable Dimensions Installation and Tightening Torque [Table 1]
(Unit: mm)
IV Oil resistant cable(IEC standards model)
When tightening the nut, use the provided washer as [Figure 1].
Cable type Cable connector type Connector type Cable type Strength Front Rear
Sensing side No mark Standard type Type When installing the product, the tightening torque of the nut varies
PRT(M8, M12, M18, M30) PRWT(M8, M12, M18, M30) PRCMT(M12, M18, M30) PSNT17 Model Size Torque Torque
according to the distance from the fore-end.
U Upper sensing type B B J PRT08 Flush 7mm
B 30.8 2-Ø3.2 The front part of the product is from the fore-end to the dimension on 3.92N·m 8.82N·m
C J C the below table, and the rear part is from the tip of the nut to the end Series Non-flush 5mm
Control output O Normally Open(N.O.) C
of the product. [Figure 2] PRT12 Flush 13mm
C Normally Closed(N.O.) Flush 18 11 6.37N·m 11.76N·m
In case the nut is placed in the front part of the product, apply Series Non-flush 7mm
F F M12×1 tightening torque for front part.
Power supply X 12-24VDC(Non-polarity type) A A M12×1
A PRT18 Flush -
D D D LED [Table 1] the allowable tightening torque table is for inserting the 14.7N·m
Series Non-flush -
D 12-24VDC washer as [Figure 3].
B B J B
Sensing distance PRT30 Flush 26mm
C Ø4 49N·m 78.4N·m
Number Standard sensing distance(Unit: mm) E C J E C Series Non-flush 12mm
Non- 18
Dimension Number Diameter of head(Unit: mm) flush [Figure 1] [Figure 2] [Figure 3]
Nut tip
Number One side length(Unit: mm) F E A
F
M12×1 M12×1 Fore-end
A A 35.6 2,000
D D D
T DC 2-wire, cable type
Connection
WT DC 2-wire, cable connector type Nut
&
G
G
H
Washer Washer Mounting
Front Rear bracket
Shape R Cylindrical type
SN Square new design type Type A B C D E F G H J
Item
P Inductive proximity sensor
PRT M8×1 30 30 4 - 3.5 13 15 2,000 Cautions during Use
M8
PRWT M8×1 30 30 4 - 4 13 15 300 1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
PRT M12×1 46 31.5 4 - 4 17 21 2,000 2. 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
Control Output Diagram & Load Operation M12 PRWT M12×1 46 31.5 4 - 4 17 21 300
3. Use the product, after 0.8 sec of supplying power.
4. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
Normally Open Normally Closed PRCMT M12×1 55.8 31.5 4 - - 17 21 - Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.).
Load +V
Brown Sensing Presence Presence Flush PRT M18×1 47.5 29.5 4 - 5 24 29 2,000 In case installing the product near the equipment which generates strong surge (motor, welding machine, etc.), use diode or varistor
Main circuit
target Nothing Nothing M18 PRWT M18×1 47.5 29.5 4 - 5 24 29 300 to remove surge.
PRCMT M18×1 54.3 29.5 4 - - 24 29 - 5. Do not connect capacity load to the output terminal directly.
Operation Operation
Load 6. This unit may be used in the following environments.
Return Return PRT M30×1.5 58 38 5 - 5 35 42 2,000
① Indoors (in the environment condition rated in 'Specifications') ② Altitude max. 2,000m
Blue Operation indicator ON ON M30 PRWT M30×1.5 58 38 5 - 5 35 42 300
0V ③ Pollution degree 2 ④ Installation category II
(Red RED) OFF OFF PRCMT M30×1.5 63.8 38 5 - - 35 42 -
PRT M8×1 30 26 4 4 3.5 13 15 2,000
M8
Setting Distance PRWT M8×1 30 26 4 4 4 13 15 300 Major Products
PRT M12×1 46 24.5 4 7 4 17 21 2,000
Target Target ● Detecting distance can be changed by the shape, size or material of the target. Photoelectric Sensors Temperature Controllers Graphic/Logic Panels
M12 PRWT M12×1 46 24.5 4 7 4 17 21 300 Fiber Optic Sensors Temperature/Humidity Transducers Field Network Devices
Therefore please check the detecting distance like (a), then pass the target within range
PRCMT M12×1 55.8 24.5 4 7 - 17 21 - Door Sensors SSRs/Power Controllers Laser Marking System(Fiber, CO₂, Nd:YAG)
Moving Moving of setting distance(Sa). Door Side Sensors Counters Laser Welding/Cutting System
direction direction Sa Sn Non-flush PRT M18×1 47 19 4 10 5 24 29 2,000 Area Sensors Timers
● Setting distance(Sa) http://www.autonics.com
M18 PRWT M18×1 47 19 4 10 5 24 29 300 Proximity Sensors Panel Meters
= Sensing distance(Sn)× 70% HEADQUARTERS:
PRCMT M18×1 53.8 19 4 10 - 24 29 - Pressure Sensors Tachometers/Pulse(Rate) Meters 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
Sn: Sensing distance
E.g.)PRCMT12-2DC Rotary Encoders Display Units South Korea, 48002
{ Sa: Setting distance Setting distance(Sa) = 2mm × 0.7 = 1.4mm PRT M30×1.5 58 28 5 10 5 35 42 2,000 Connectors/Sockets Sensor Controllers TEL: 82-51-519-3232
(70% of Sn) M30 PRWT M30×1.5 58 28 5 10 5 35 42 300 Switching Mode Power Supplies E-mail: sales@autonics.com
(a) (b) Control Switches/Lamps/Buzzers
PRCMT M30×1.5 63.8 28 5 10 - 35 42 - DRW171496AA
※The above specifications are subject to change and some models may be discontinued without notice. I/O Terminal Blocks & Cables
※Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage). Stepper Motors/Drivers/Motion Controllers