Additional Restraint On Shafts

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

04 05 04

250x400 Tie Beams/


Steel Separator Beams
with end plate
250x400 RC
Tie Beams
Floor Level

1.35 m
Core Wall Additional Horizontal Core
Wall Rebar anchored to Separator Beams
the wall ends
(Level 14 and above)
Floor Level

CORE WALL ELEVATION


Separator Beams

250x400 250x400 RC
ldt Tie Beams Tie Beams
ldt 1.35 m

Additional Horizontal Core 6T25 top bar (straight


3T25 top + Wall Rebar (Total 12T16 anchorage to the slab)
3T25 bottom rebar over 1350mm wall height, 200x15 plate
T10-85 Links
6T16 on each face)
3T16 bottom bar
3T16 Core Wall (hook anchorage)
200x25 plate

Core Wall TYPICAL SEPARATOR BEAMS TYPICAL 250x400 RC


Beam, slab and other wall reinforcements are not shown for clarity Horizontal Rebar BUILT-UP SECTION TIE BEAMS

TYPICAL ADDITIONAL HORIZONTAL REBAR INSIDE CORE WALL


(FOR LEVEL 14 AND ABOVE)
Unless Noted Otherwise:
1. All Rebar Grade shall be FY=500 MPa. TYPICAL TIE BEAMS AND SEPARATOR
2. All Steel Grade shall be S355 or Equivalent.
3. All Bolts shall be HTB A490M or Equivalent BEAMS POSITION AT SHAFT LOCATION
4. All Connection to be Full-Strength Full-Penetration Butt Weld (FPBW).
5. All Steelwork to be corrosion-protected and fire-protected as per specifications and relevant standards to specialist's detail. WITH ADDITIONAL HORIZONTAL CORE
Vermiculite FIre Spray for specified duration of Fire-Rating to be compatible with Corrosion Resistant Paint Protection System with WALL REBAR
minimum dry-film-thickness of Epoxy Zinc Rich Primer (75 micron) + Epoxy base coat (125 micron) + Epoxy finishing coat (50 micron)